• Title/Summary/Keyword: flow path

Search Result 998, Processing Time 0.025 seconds

A Flow Control Scheme based on Queue Priority (큐의 우선순위에 근거한 흐름제어방식)

  • Lee, Gwang-Jun;Son, Ji-Yeon;Son, Chang-Won
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.1
    • /
    • pp.237-245
    • /
    • 1997
  • In this paper, a flow control mechanism is proposed which is based on the priority control between communication path of a node. In this scheme, demanding length of a data queue for any pre-defined, then each node in that path is forced to maintains buffer size under the limit by controlling priority level of the path. The communication path which requires higher bandwidth sets its demanding queue length smaller. By providing relationship between the priority of a path and length of its queue, the high bandwidth requesting path has a better chance to get high bandwidth by defining the smaller demanding queue size. And also, by forcing a path which has high flow rate to maintain small queue size in the path of the communication, the scheme keep the transmission delay of the path small. The size of the demanding queue of a path is regularly adjusted to meet the applications requirement, and the load status of the network during the life time of the communication. The priority control based on the demanding queue size is also provided in the intermediate nodes as well as the end nodes. By that the flow control can provide a quicker result than end to-end flow control, it provides better performance advantage especially for the high speed network.

  • PDF

Comparison of Ultrasonic Paths for Flow Rate Measurement (유량측정을 위한 초음파 전파경로 비교)

  • Kim, Ju Wan;Piao, Chunguang;Kim, Jin Oh;Park, Doo-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.7
    • /
    • pp.455-461
    • /
    • 2015
  • The paper deals with the accuracy comparison between two kinds of ultrasonic paths for flow rate measurement. In the Z-path, two transducers are installed on the opposite sides of each other on a pipe, and the ultrasonic waves generated at one transducer propagate to arrive at the other one only by refraction. In the V-path, two transducers are installed on one side of a pipe, and the ultrasonic waves reflected at the inner wall of the pipe are received. Transit times were confirmed to identify the propagation paths by comparing the theoretically calculated results and measured ones. The flow rate measurements with two kinds of ultrasonic paths appeared very similar. It would be possible to select either of the paths by considering the advantages and disadvantages.

Determinants of Effecting Customer Loyalty : Comparison among Korean, Japanese and Chinese Online Game Market (온라인게임 사용자의 충성도에 영향을 미치는 요인에 관한 연구 : 한국, 일본, 중국 온라인게임 시장 비교)

  • Lee, Sang-Chul;Xiang, Jun-Yong;Gu, Ja-Chul;Suh, Yung-Ho
    • Korean Management Science Review
    • /
    • v.23 no.2
    • /
    • pp.41-57
    • /
    • 2006
  • The purposes of this research are to identify causalities among flow and customer loyalty In Chinese online games, and to identify the factors by which flow are influenced. This research tests the model with Chinese on-line game users and compare this result with Korea and Japanese results which were conducted by Lee's research. These implications are thought to be helpful for Korean online game companies to understand the Chinese online game user and to develop the penetration strategies. The results indicated that significant Path coefficients to flow were the convenience of operator, the provision of information, the reality of design. The results indicated that significant path coefficients to customer loyalty were the involvement of virtual community and flow. The involvement of virtual community to flow was not significant but to customer loyalty was significant. The provision of information was negatively influenced on flow. The result of comparison indicated that the path coefficients were different among nations. Korea online game companies need to develop the indigenized online game and to Provide the information to their Chinese partner correctly and quickly.

Analytical Surge Behaviors in Systems of a Single-stage Axial Flow Compressor and Flow-paths

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.1
    • /
    • pp.1-16
    • /
    • 2016
  • Behaviors of surges appearing near the stall stagnation boundaries in various fashions in systems of a single-stage compressor and flow-path systems were studied analytically and were tried to put to order. Deep surges, which enclose the stall point in the pressure-mass flow plane, tend to have either near-resonant surge frequencies or subharmonic ones. The subharmonic surge is a multiple-loop one containing, for example, in a (1/2) subharmonic one, a deep surge loop and a mild surge loop, the latter of which does not enclose the stall point, staying only within the stalled zone. Both loops have nearly equal time periods, respectively, resulting in a (1/2) subharmonic surge frequency as a whole. The subharmonic surges are found to appear in a narrow zone neighboring the stall stagnation boundary. In other words, they tend to appear in the final stage of the stall stagnation process. It should be emphasized further that the stall stagnation initiates fundamentally at the situation where a volume-modified reduced resonant-surge frequency becomes coincident with that for the stagnation boundary conditions, where the reduced frequency is defined by the acoustical resonance frequency in the flow-path system, the delivery flow-path length and the compressor tip speed, modified by the sectional area ratio and the effect of the stalling pressure ratio. The real surge frequency turns from the resonant frequency to either near-resonant one or subharmonic one, and finally to stagnation condition, for the large-amplitude conditions, caused by the non-linear self-excitation mechanism of the surge.

Analysis of Flow Performance According to Actuator Geometry of Receptacle for Hydrogen Charging System with Filter Applied (필터가 장착된 수소충전시스템용 리셉터클의 작동부 형상에 따른 유동 성능 분석)

  • JU HWAN CHOI; GU HO KIM;JAE KWANG KIM;YONG KI KIM;HYUN KYU SUH
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.1
    • /
    • pp.17-25
    • /
    • 2023
  • The purpose of this study was to propose a design that shows optimal performance by changing the geometry of the internal flow path of the receptacle in order to prevent the decrease in flow rate and differential pressure performance due to the application of the receptacle in the hydrogen charging system. To achieve this, 3D computational fluid dynamics simulation was performed for the receptacle, according to the geometry of the flow path inside the receptacle. The pressure results at the inlet and outlet were measured the same as both of N and H2 in the experiment, and the flow rate of H2 was 3.75 times higher than that of N2. In addition, since the flow performance of the receptacle improved under conditions where the flow path was widened, it was confirmed that reducing the diameter of the poppet and the width of the guide are advantageous for improving performance.

Deviation Characteristics of Clamp-on Type Ultrasonic Flowmeter Installed in Downstream of Valves (밸브 하류에 설치된 건식 초음파유량계의 편차특성)

  • Lee, Dong-Keun;Cho, Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.4
    • /
    • pp.12-18
    • /
    • 2012
  • This study was performed to found out the deviations for clamp-on type ultrasonic flowmeter installed in downstream of valves. It was selected three types of two-path flowmeter mainly used for K-water as test. Experiment carried out to confirmed characteristics of deviation depending on the sensor location, straight pipe length and maker for 1-path, 2-path and 4-path combined 2-path flowmeter. It was selected two kinds of valves with 100 % and 50 % opening, butterfly valves and gate valves, for flow disturbance factor. Finally, we suggested number of sensors by maker, straight pipe length and installed location of sensors satisfying the tolerance depending on the experiment results.

Linear Time Algorithm for Network Reliability Problem

  • Lee, Sang-Un
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.5
    • /
    • pp.73-77
    • /
    • 2016
  • This paper deals with the network reliability problem that decides the communication line between main two districts while the k districts were destroyed in military communication network that the n communication lines are connected in m districts. For this problem, there is only in used the mathematical approach as linear programming (LP) software package and has been unknown the polynomial time algorithm. In this paper we suggest the heuristic algorithm with O(n) linear time complexity to solve the optimal solution for this problem. This paper suggests the flow path algorithm (FPA) and level path algorithm (LPA). The FPA is to search the maximum number of distinct paths between two districts. The LPA is to construct the levels and delete the unnecessary nodes and edges. The proposed algorithm can be get the same optimal solution as LP for experimental data.

Installation Effects on the Characteristics of Multi-path Ultrasonic Flowmeter with Valve (밸브후단에서의 다회선 초음파 유량계의 특성변화)

  • Hwang, S. Y.;Seo, K. H.;Kim, B. C.;Kim, K. S.;Tyan, H. S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.65-74
    • /
    • 2000
  • A five path ultrasonic and/or magnetic flowmeter were installed after valve. Five path ultrasonic flowmeter were tested to obtain it's performance in a water flow standard system and magnetic flowmeter. It's varied with straight pipe length(nD), install direction and valve position. All the results are summerized. The multi-path flowmeters(MUF) showed up to $\pm0.5{\%}$ at a 2, 4, 8, 15D spacing : the MUF was significantly better than magnetic flowmeter at disturbed flow conditions.

  • PDF

A Design and Performance Evaluation of Path Search by Simplification of Estimated Values based on Variable Heuristic (가변 휴리스틱 기반 추정치 간소화를 통한 경로탐색 기법의 설계 및 성능 평가)

  • Kim, Jin-Deog
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.11
    • /
    • pp.2002-2007
    • /
    • 2006
  • The path search method in the telematics system should consider traffic flow of the roads as well as the shortest time because the optimal path with minimized travel time could be continuously changed by the traffic flow. The existing path search methods are not able to cope efficiently with the change of the traffic flow. The search method to use traffic information also needs more computation time than the existing shortest path search. In this paper, a method for efficiency improvement of path search is implemented and its performance is evaluated. The method employs the fixed grid for adjustable heuristic to traffic flow. Moreover, in order to simplify the computation of estimation values, it only adds graded decimal values instead of multiplication operation of floating point numbers with due regard to the gradient between a departure and a destination. The results obtained from the experiments show that it achieves the high accuracy and short execution time as well.

A Study on the Transmitted Energy Contribution Analysis of SUV Engine Mount by Vibration Power Flow Measurement (진동 파워흐름 측정을 통한 SUV용 엔진 마운트의 에너지 전달 기여도 분석에 관한 연구)

  • Kim, Su-Gon;Lee, Sang-Kwon;Kim, Sung-Jong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.400-410
    • /
    • 2008
  • Reduction of structure-borne noise in the compartment of a car is an important task in automotive engineering. Many methods which analyze noise transfer path have been generally used for structure-borne noise. These methods are useful in solving particular problem but do not quantify the effectiveness of vibration isolation for each isolator of a vehicle. To quantify the effectiveness of vibration isolation, the vibrational power flow measurement has been used for a simple isolation system or a laboratory based isolation system. This paper identifies the transfer path of booming noise in a SUV. The powertrain used for test has a in-line 4cylinder engine and 5-shift auto-transmission. This powertrain is transversely supported by four isolators. We calculated the energy flow throughout four isolator by the measurement of power flow and the contribution of energy flow at each isolator.