• 제목/요약/키워드: flow monitoring

검색결과 1,245건 처리시간 0.029초

Numerical and laboratory investigations of electrical resistance tomography for environmental monitoring

  • Heinson Tania Dhu Graham
    • 지구물리와물리탐사
    • /
    • 제7권1호
    • /
    • pp.33-40
    • /
    • 2004
  • Numerical and laboratory studies have been conducted to test the ability of Electrical Resistance Tomography-a technique used to map the electrical resistivity of the subsurface-to delineate contaminant plumes. Two-dimensional numerical models were created to investigate survey design and resolution. Optimal survey design consisted of both downhole and surface electrode sites. Resolution models revealed that while the bulk fluid flow could be outlined, small-scale fingering effects could not be delineated. Laboratory experiments were conducted in a narrow glass tank to validate theoretical models. A visual comparison of fluid flow with ERT images also showed that, while the bulk fluid flow could be seen in most instances, fine-scale effects were indeterminate.

Variations of Limnological Functions in a Man-made Reservoir Ecosystem during High-flow Year vs. Low-flow Year

  • Lee, Sang-Jae;An, Kwang-Guk
    • 생태와환경
    • /
    • 제42권4호
    • /
    • pp.487-494
    • /
    • 2009
  • We compared spatial and temporal variations of water chemistry between high-flow year ($HF_y$) and low-flow year ($LF_y$) in an artificial lentic ecosystem of Daechung Reservoir. The differences in the rainfall distributions explained the variation of the annual inflow and determined flow characteristics and water residence time and modified chemical and biological conditions, based on TP, suspended solids, and chlorophylla, resulting in changes of ecological functions. The intense rainfall and inflow from the watershed resulted in partial disruption of thermal structure in the metalimnion depth, ionic dilution, high TP, and high suspended solids. This condition produced a reduced chlorophyll-a in the headwaters due to low light availability and rapid flushing. In contrast, reduced inflow and low rainfall by drought resulted in strong thermal difference between the epilimnion and hypolimnion, low inorganic solids, high total dissolved solids, and low phosphorus in the ambient water. The riverine conditions dominated the hydrology in the monsoon of $HF_y$ and lacustrine conditions dominated in the $HF_y$. Overall data suggest that effective managements of the flow from the watershed may have an important role in the eutrophication processes.

실시간 교통흐름의 모니터링 및 제어를 위한 교차로 시뮬레이션 시스템 설계 (Design of Intersection Simulation System for Monitoring and Controlling Real-Time Traffic Flow)

  • 정창원;신창선;주수종
    • 인터넷정보학회논문지
    • /
    • 제6권6호
    • /
    • pp.85-97
    • /
    • 2005
  • 본 논문은 도로상에 설치된 각종 교통정보 기기로부터 수집된 정보를 이용하여 교통정보 데이터베이스를 구축하고 이를 이용하여 교차로를 기점으로 도로의 구간별 실시간 교통흐름을 동적으로 관리할 수 있는 교차로 시뮬레이션 시스템을 제안한다. 본 시스템은 계층적인 3 부분으로 구성된다. 하위계층은 실제 도로 상에서 교통정보가 수집되는 물리계층이다. 중간계층은 하위계층의 교통정보를 이용하여 교차로들의 그룹, 실시간 교통흐름 정보의 수집, 원격 모니터링 및 제어를 지원하는 교통흐름 제어 프레임워크가 존재한다. 본 계층은 분산객체그룹 프레임워크를 확장하여 설계됐다. 상위계층에는 교차로들의 그룹화로 교통흐름을 제어하는 교차로 시뮬레이터 응용들이 존재한다. 교차로 응용은 TMO(Time-triggered Message-triggered Object) 스킴 기반의 구현객체들로 이루어진다. 교차로 시뮬레이션 시스템에서는 도로상의 각 교차로를 하나의 응용 그룹으로 고려하며, 교차로들 간에 상호통신으로 수집된 실시간 도로소통 상태정보를 이용하여 주어진 도로상황에 따라 동적인 교통흐름 제어기법들의 적용이 가능하도록 하였다. 본 시스템 구축을 위해 TMO 스킴과 TMOSM(TMO Support Middleware) 지원교통흐름 제어 프레임워크 기반에서 시스템 구조와 구성요소의 상호작용을 정의했으며, 교통흐름 모니터링 및 제어를 위한 응용 시뮬레이터와 사용자 인터페이스를 설계했다.

  • PDF

수질오염총량관리 단위유역 유량측정자료를 이용한 유황곡선 작성 (Development of a Flow Duration Curve with Unit Watershed Flow Data for the Management of Total Maximum Daily Loads)

  • 박준대;오승영;최윤호
    • 한국물환경학회지
    • /
    • 제28권2호
    • /
    • pp.224-231
    • /
    • 2012
  • It is necessary to develop flow duration curve (FDC) on each unit watershed in order to analyze flow conditions in the stream for the management of Total Maximum Daily Loads (TMDLs). This study investigated a simple method to develop FDC for the general use of the curve. A simple equation for daily flow estimation was derived from the regression analysis between the 8-day interval flow data of a unit watershed and the daily flow monitoring data of an adjacent upstream region. FDC can be prepared with the calculation of daily flow by the equation for each unit watershed. An annual and a full-period FDC were drawn for each unit watershed in Guem river basin. Standard flow such as low and ordinary flow can be obtained from the annual FDC. Major percentile of flow such as 10, 25, 50, 75 or 90% can be obtained from the full-period FDC. It is considered that this simple method of developing FDC can be utilized more widely for the calculation of standard flow and the assessment of water quality in the process of TMDLs.

Esophageal pH and Combined Impedance-pH Monitoring in Children

  • Shin, Myung Seok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제17권1호
    • /
    • pp.13-22
    • /
    • 2014
  • Esophageal pH monitoring is considered the gold standard for the diagnosis of gastroesophageal reflux disease because of the normal ranges across the pediatric age range. However, this method can only detect acid reflux. Multichannel intraluminal impedance-pH (MII-pH) monitoring has recently been used for the detection of bolus reflux in infants and children. This method allows for the detection of liquid, gas or mixed reflux in addition to acid, weakly acidic or weakly alkaline reflux. MII-pH monitoring can record the direction of flow and the height of reflux, which are useful parameters to identify an association between symptoms and reflux. However, the technique is limited by its high cost and the lack of normative data of MII-pH in the pediatric population. Despite certain limitations, MII-pH monitoring will become more common and gradually replace pH monitoring in the future, because pH monitoring is part of MII-pH.

용광로 연소대 관리시스템 개발 (Development of combustion zone monitoring system for a blast furnace)

  • 최태화
    • 제어로봇시스템학회논문지
    • /
    • 제3권3호
    • /
    • pp.318-322
    • /
    • 1997
  • A prototype of combustion zone monitoring system as been developed and installed into tuyeres of the blast furnace. The system consists of CCD(charge coupled device) cameras, sonic flow meters, an image processor and a personal computer. The personal computer collects raceway luminance data and operational data from the image processor that is connected to the color CCD camera from the blast furnace process computer, respectively. In addition, the sonic flow meters supply coal injection rate data to the personal computer. Then, the personal computer evaluates the combustion conditions with the raceway inspection algorithm. This integrated monitoring system allows us to detect abnormal raceway conditions and the clogging status of coal injection pipe. The image processing techniques of the system enable us to effectively monitor unburnt coal sticking to tuyere tip and injection lance wear conditions. Such a developed system ensures rapid and precise raceway inspection. The image processing capability of the system has helped operator to early detect both the unburnt coal sticking problem and the errosion problem of injection lance. Furthermore, the system could control the abnormal raceway condition based the the analysis results obtained from combustion monitoring.

  • PDF

지하수위와 수온 변동에 나타난 부지 규모 지하수 흐름장의 복잡성 (Complexity of Groundwater Flow System in a Site Reflected in the Fluctuations of Groundwater Level and Temperature)

  • 박종훈;이동엽;우남칠
    • 자원환경지질
    • /
    • 제55권6호
    • /
    • pp.563-570
    • /
    • 2022
  • 이 조사는 지상에 존재하는 지하수의 잠재오염원(저장탱크)으로부터 오염물질 누출 시, 이를 조기 진단하기 위한 지하수 오염관측망의 설계 인자로서 부지 규모 지하수환경의 시공간적 변동성을 파악하고자 시행되었다. 부지 내 위치한 저장탱크 주변에 22~25 m 심도로 3개의 관측공을 설치하고, 이들로부터 약 22개월 동안 2분 간격으로 지하수위와 수온 변화를 관측하였으며, 이 자료는 주변 기상관측소의 강수 및 기온 자료와 비교 분석되었다. 조사기간 동안 지하수위의 연 변화와 강수 현상에 대한 반응, 지하수온의 변동과 기온에 대한 지연시간 등은 비교적 작은 규모의 부지에서도 지하수 흐름과 유동 경로의 복잡성을 지시한다. 따라서 오염누출 감시를 위한 지하수 관측망은 상세한 부지특성화 조사 결과에 근거하여 부지 지하수환경의 복잡성을 충분히 고려하여 설계되어야 한다.

비강우시 도시 합류식 하수도의 오염부하 산정을 위한 최적관측시간 산정연구 (Optimum Flow and Pollution Load Monitoring Time of Combined Sewers of Urban Watersheds during Dry Weather)

  • 최용훈;원철희;박운지;서지연;신민환;이찬기;최중대
    • 한국농공학회논문집
    • /
    • 제51권3호
    • /
    • pp.9-14
    • /
    • 2009
  • Flow and pollution load were monitored at 2 combined sewer outlets (C-1 and C-2) of urban watersheds during dry weather from September, 2004 to April, 2006 for 20 months. The objectives were to investigate the diurnal variation of flow and pollutant load and to find the proper sampling time that could measure representative flow and pollutant load. Pollution load closed to the average daily load at C-1 could be measured at 00:00 hour and by the mean of 15:00 and 18:00 hour measures, and 15:00 and 21:00 hour measures, respectively. In addition at C-2, it was 21:00 hour and the mean of 15:00 and 18:00 hour measures. This study concluded that arbitrary sampling of flow and water quality could cause large errors in the estimation of urban pollution load and recommended that urban combined sewers should be monitored when flow and water quality showed daily average and concentration.

Cerebral Blood Flow Monitoring by Diffuse Speckle Contrast Analysis during MCAO Surgery in the Rat

  • Yeo, Chaebeom;Kim, Heejaung;Song, Cheol
    • Current Optics and Photonics
    • /
    • 제1권5호
    • /
    • pp.433-439
    • /
    • 2017
  • The rodent model has been used frequently to understand stroke pathophysiology, due to its low cost and the large spectrum of genetic strains available. Here, we present a diffuse speckle contrast analysis system (DSCA) with a $1{\times}2$ optical switch that was used to non-invasively assess cerebral blood flow (CBF) changes in the rat during intraluminal suturing for middle cerebral artery occlusion (MCAO) surgery. The blood flow index (BFI) in the left hemisphere was lower than that in the right hemisphere because the left middle cerebral artery was occluded. Furthermore, the performance of the DSCA system was compared with that of commercial laser Doppler flowmetry. The changes in the BFI measured by the two systems were correlated strongly. The DSCA system was less sensitive to motion artifacts and able to measure relatively deep tissue flow in the rat's brain. In conclusion, the DSCA system secured CBF monitoring during surgery in a rodent model without craniotomy.

빗물 자동모니터링장치와 SWMM 모델을 이용한 강우시 도시지역 오염부하량 예측에 관한 연구 (Application of Automatic Stormwater Monitoring System and SWMM Model for Estimation of Urban Pollutant Loading During Storm Events)

  • 서동일;방철호
    • 대한환경공학회지
    • /
    • 제34권6호
    • /
    • pp.373-381
    • /
    • 2012
  • 대전의 도시 소하천, 관평천 유역을 연구대상지역으로 강우시의 유량 및 수질 변화 특성을 파악하기 위한 원격 제어실시간 자동 모니터링 시스템을 설치하여 자료를 확보하고 이 시스템을 이용하여 확보된 강우시 연속측정 자료를 이용하여 도시유역 모델인 SWMM (Storm Water Management Model) 모델을 보정하는 데 사용하였다. 실시간 자동 모니터링 시스템은 강우량계, 초음파 수위계, 자동수질측정장치, 자동취수장치, 데이터 로거 및 전송장치 등으로 구성되었으며 원격으로 제어할 수 있도록 설계되었다. 강우시 유량은 초음파 수위계와 사각 위어 공식을 이용하여 지속적으로 측정이 가능하도록 설계되었으며 정확도는 수동측정을 병행하여 확인하였다. 수질센서로 측정할 수 없는 항목은 자동채수기에 의해 일정시간 간격으로 시료를 채취한 후 실험실로 이송하여 분석하여 자료를 확보하였다. 위에서 실측된 유량 및 수질 연속 자료를 이용하여 연구대상지역에 대해 SWMM 모델을 구축하였다. SWMM 모델의 보정과 검증 결과 유량은 매우 양호한 수준으로 예측하고 있으나 BOD, COD, SS, TN, TP 등의 예측은 강우 특성에 따라 차이가 있는 것으로 나타났다. 본 연구는 SWMM에 나타난 바와 같은 특정 유역에 고정된 형태의 오염물질 축적과 유출현상을 나타내는 경험식이 강우 및 선행강우 특성을 반영하여 수정될 필요가 있다는 것을 시사하고 있다. 본 연구에서 제안된 빗물 자동모니터링 및 모델링 시스템은 향후 강우에 따른 하천 수질관리를 위한 유역단위의 빗물 수량 수질 관리시설의 설계 및 운영에 중요한 자료로 활용될 수 있을 것으로 기대된다.