• 제목/요약/키워드: flow monitoring

검색결과 1,241건 처리시간 0.028초

수술중 경두개 초음파 집중감시 (Intraoperative Transcranial Doppler Monitoring)

  • 서대원
    • Annals of Clinical Neurophysiology
    • /
    • 제1권1호
    • /
    • pp.70-75
    • /
    • 1999
  • Trancranial Doppler(TCD) monitoring is a new application of ultrasonography which allows the nonivasive detection of blood flow velocity in the horizontal (M1) segment of the middle cerebral artery (MCA) and detects microembolic phenomena in the cerebral circulation. Recent studies emphasized the potential of using this technique in vascular surgery (carotid endarterectomy, cardiopulmonary bypass), interventional and intensive care setting. Although the disparity between CBF and blood flow velocity and number of microemboli could be used to prevent cerebral ischemic and embolism based on clinical studies. A reduction of more than 60% of MCA can reflex hemodynamic ischemic state and acoustic feedback of high intensity transient signals(HITS) from the TCD monitoring unit has a direct influence on surgical technique. TCD monitoring can immediately provide information about thromboembolism and hemodynamic changes, which may be a useful tool in the study and prevention of stroke.

  • PDF

초음파를 이용한 기체 유동장내 분진 모니터링 (Particle Monitoring Using Ultrasound in the Gas Flow)

  • 장경영;김주철;김홍준;황원호
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.78-85
    • /
    • 2004
  • The particle amount monitoring technique using ultrasound is proposed to determine the proper maintenance time of the filter in the supply process of pure gas in the unit of oxygen plant. There are advantages that it is adaptable in high temperature and high pressure, and it is not disturbed by being exposed in the gas flow, and it can be implemented very economically. The applicability of the ultrasonic technique is pre-studied through the theoretical analysis for the dependency of attenuation of ultrasonic wave on the particles in the gas flow. For the purpose, absorption, scattering and dispersion models are considered, and the attenuation by absorption and the change rate of the propagation speed are calculated fur the specific range of particle size and the ultrasonic wave frequency. It was expected by simulation that the absorptive attenuation by particles was the most sensitive to the change of particle amount. The experimental result showed high correspondence with the theoretical expectation so that this ultrasound attenuation measurement was proved to be highly effective for monitoring the amount of floating particles in the gas flow.

Minimum detectable activity of plastic scintillator for in-situ beta measurement system in ground water

  • Choi, Woo Nyun;Lee, UkJae;Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1169-1175
    • /
    • 2019
  • The minimum detectable activity (MDA) value was derived according to the flow rate of the sample and degree of amplification of the device by sending the sample directly from the collection site to the detection part through a pump. This method can lead to reduction in time and cost compared to the existing measurement method that uses a pre-treatment process. In this study, experiments were conducted on $^3H$ and $^{90}Sr$, which are the major pure beta-emitting radionuclides, by setting the sample flow rate and the amplification gain as factors. The MDA values were derived according to the flow rates, considering that the flow rate can affect the MDA values. There were no change in the MDA under different flow rates of 0, 600, 800, and 1000 mL/min. Therefore, it was confirmed that the flow rate may not be considered when collecting samples for monitoring in actual field. As the degree of amplification of the amplifier increased, the time required to reach the target MDA decreased. When the amplification was quadrupled, the detection efficiency increased by approximately 23.4 times, and the time to reach the MDA decreased to approximately 1/550 times. This method offers the advantage of real-time on-site monitoring.

수위-유속 분산 그래프를 통한 하수흐름 특성 분석 (Sanitary sewer flow characteristics through a depth-velocity scatter graph analysis)

  • 손주영;오재일
    • 상하수도학회지
    • /
    • 제28권6호
    • /
    • pp.647-655
    • /
    • 2014
  • To perform long-term sewer monitoring, It is important to understand the nature of the wastewater flow that occurs at the point on early stage of the monitor and to prevent in advance a problem which may caused. We can infer the flow properties and external factors by analyzing the scatter graph obtained from the measured data flow rate monitoring data since an field external factor affecting the sewage flow is reflected in the flow rate monitoring data. In this study, Selecting the three points having various external factors, and we Inferred the sewer flow characteristics from depth-velocity scatter graph and determined the analysis equation for the dry-weather flow rate data. At the'point 1' expected non-pressure flow, we were able to see the drawdown effect caused by the free fall in the manhole section. At the'point 2', existed weir and sediments, there was backwater effect caused by them, and each of size calculated from the scatter graph analysis were 400 mm and 130 mm. At the'Point 3', there is specific flow pattern that is coming from flood wave propagation generated by the pump station at upstream. In common, adequate equations to explain the dry weather flow data are flume equation and modified manning equation(SS method), and the equations had compatibility for explaining the data because all of $R^2$ values are over 0.95.

실시간 유비쿼터스 하천정보 모니터링 시스템의 개발 (Development of Realtime Ubiquitous River Monitoring System)

  • 장복진;이종국;여운광
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1305-1312
    • /
    • 2006
  • 본 연구는 하천유황 모니터링을 위하여 유비쿼터스 기반의 무선통신기술 인프라를 이용하여 개발한 하천정보 수집용 계측시스템에 관한 것이다. 이 시스템은 사용자에 의하여 자유이동하면서 하천의 수심, 수질 및 유속(유량)을 실시간으로 관측 및 모니터링 할 수 있도록 하였다. 개발된 하천부이 시스템은 하천의 수위, 수질(수온, pH, 탁도, 전도도 등) 자료를 획득함과 동시에 획득 장소의 위치정보를 획득할 수 있도록 GPS 모듈을 추가하였다. 또한 이 하천부이는 무선RF 조정이 가능하여 원하는 위치에서의 정보를 손쉽게 획득할 수 있도록 하였다. 획득된 자료는 자료 중계기(Gateway system)의 Zigbee 무선통신을 이용하여 전송하게 하였으며, GIS 모니터링 툴을 이용하여 자료를 확인하고, 확인된 자료는 CDMA 원거리 무선통신을 이용하여 서버컴퓨터로 전송할 수 있게 하였다. 서버컴퓨터에 전송된 하천의 정보는 DB 자동구축과 함께 웹기반의 실시간 모니터링이 가능하도록 하였다. 연구개발 결과는 독립적인 하천정보 모니터링 시스템으로 활용 가능할 뿐만 아니라 하천교량 세굴과 그 밖의 호수 및 해양 환경 모니터링 시스템 등으로 국내외에 많은 분야에 활용될 수 있을 것으로 판단된다.

  • PDF

TIG클래딩 공정에 대한 품질 모니터링기법의 개발 (Development of Welding Quality Monitoring Method for TIG Cladding)

  • 조상명;박정현;손민수
    • Journal of Welding and Joining
    • /
    • 제31권6호
    • /
    • pp.90-95
    • /
    • 2013
  • Pipe inside clad welding is mainly used to the flow pipe of sub-sea or chemical plant. For the inside clad welding to the medium pipe with the diameter of about 12", TIG welding is frequently applied with filler metal. In this case, the clad welding has the very broad weld area over $10m^2$. And, the non-destructive test (NDT) such as ultrasonic test (UT) or radiographic testing (RT) should be conducted on the broad weld area, and it costs very high due to the time-consuming work. Therefore, the present study investigated the variation of arc voltage to develop the in-line quality monitoring system for the pipe inside TIG cladding. The 4 experimental parameters (current, arc length, wire feed position, and shield gas flow rate) varied to observe the change of arc voltage and to establish the model for the monitoring. The arc voltage was decreased when the wire was fed to the backward eccentric position(over 2mm), and the shield gas flow rate was insufficient under 10L/min. In the case of the backward eccentric position over 2mm, the bead appearance was not good and the dilution ratio was increased due to deep penetration. When the shield gas flow rate was lower than 10L/min, the bead surface was oxidized.

댐 제체 및 침투수 흐름의 지열학적 고찰 (A Study on Geothermal Characteristics of Dam Body and Seepage Flow)

  • 박동순;정우성;김형수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.75-85
    • /
    • 2006
  • In recent geotechnical engineering, geothermal approach has been on the horizon to deal with geoenvironmental issues, freezing and thawing problems, and seepage phenomenon in dams and embankments. In this study, geothermal characteristic through inner body of dams and its influence on the seepage flow were experimented by lab test and field instrumentation. Also, one of up-to-date temperature monitoring technique, called as multi-channel thermal line sensing, was evaluated its availability. As a result of lab test, it is found that the seepage flow has influence on the geothermal characteristic and a potential of finding phreatic line and seepage fluctuation could be possible by continuous temperature monitoring using thermal line sensing skills. These kine of geothermal information could be available to the modelling of water geo-structure interaction. Out of short-term field tests, clear water table and temperature distribution of a dam were easily found through temperature monitoring in holes located near a reservoir and holes within a depth of constant temperature layer. However, it is also found that the geothermal flow and finding seepage line could not be easily understandable through multi-channel temperature monitoring because of the existence of constant temperature field, thermal conductivity of soils and rocks, and unsaturated characteristics of geo-material. In this case, long-term geothermal monitoring is recommended to find sudden fluctuation of seepage line and amount of leakage.

  • PDF

자탈형 콤바인의 실시간 벼 수확량 예측 시스템 개발 (Development of Rice Yield Prediction System of Head-Feed Type Combine Harvester)

  • 이상희;신소영;최덕규;김원경;문석표;천창욱;박석호;강연구;장성혁
    • 드라이브 ㆍ 컨트롤
    • /
    • 제21권2호
    • /
    • pp.36-43
    • /
    • 2024
  • The yield is basic and necessary information in precision agriculture that reduces input resources and enhances productivity. Yield information is important because it can be used to set up farming plans and evaluate farming results. Yield monitoring systems are commercialized in the United States and Japan but not in Korea. Therefore, such a system must be developed. This study was conducted to develop a yield monitoring system that improved performance by correcting a previously developed flow sensor using a grain tank-weighing system. An impact-plated type flow sensor was installed in a grain tank where grains are placed, and grain tank-weighing sensors were installed under the grain tank to estimate the weight of the grain inside the tank. The grain flow rate and grain weight prediction models showed high correlations, with coefficient of determinations (R2) of 0.9979 and 0.9991, respectively. A main controller of the yield monitoring system that calculated the real-time yield using a sensor output value was also developed and installed in a combine harvester. Field tests of the combine harvester yield monitoring system were conducted in a rice paddy field. The developed yield monitoring system showed high accuracy with an error of 0.13%. Therefore, the newly developed yield monitoring system can be used to predict grain weight with high accuracy.

소프트웨어 정의 네트워크 환경에서 hop-count와 정확도를 고려한 flow monitoring 방법 (Flow monitoring based on hop-count and accuracy in software defined network)

  • 권현후;도미솔;염상길;추현승
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 추계학술발표대회
    • /
    • pp.413-414
    • /
    • 2015
  • SDN은 네트워크 장비의 control plane과 data plane을 분리하고, 중앙의 컨트롤러를 통해 네트워크를 제어한다. 네트워크 운영에서 monitoring은 필수적인 요소이며, SDN 환경에서의 기존의 monitoring 방법인 OpenTM은 in-band network 환경을 고려하지 않았다. 본 논문은 in-band network 환경에서 hop-count와 정확도를 고려하여 높은 정확도를 유지하면서도 네트워크 부하를 줄일 수 monitoring 방법을 제안한다.

자동 IV 주사 유량 자동 제어 및 네트워크 모니터링 (Automatic Flow Control and Network Monitoring of IV Injection)

  • 김진남;권원태;이강희
    • 한국생산제조학회지
    • /
    • 제21권1호
    • /
    • pp.161-166
    • /
    • 2012
  • Intravenous (IV) injection is widely used to supply Ringer solution directly into a vein in hospital. Generally, a passive injection method has been used, which causes the inconsistent flow rate of fluid and inappropriate control of injection time by a patient. It leads to an unnecessary nurse's overwork and decrement of IV injection's effect. To solve these problems, flow control infusion pumps have been developed. But because of relatively heavy weight and high price, its usage has been limited. In the present study, a new automatic IV injection system is developed. It is installed with a small pressing mechanism driven by a small electric motor to regulate the flow rate by pressing tube. Proportional integral derivative (PID) feedback control algorithm is applied to control the electric motor. The system is smaller in size and uses lower power than the existing commercial product. The newly developed system is also installed with networking capability, which enables monitoring the status of several automatic IV injection system at the same time.