• 제목/요약/키워드: flow loop system

검색결과 333건 처리시간 0.021초

Three-D core multiphysics for simulating passively autonomous power maneuvering in soluble-boron-free SMR with helical steam generator

  • Abdelhameed, Ahmed Amin E.;Chaudri, Khurrum Saleem;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • 제52권12호
    • /
    • pp.2699-2708
    • /
    • 2020
  • Helical-coil steam generator (HCSG) technology is a major design candidate for small modular reactors due to its compactness and capability to produce superheated steam with high generation efficiency. In this paper, we investigate the feasibility of the passively autonomous power maneuvering by coupling the 3-D transient multi-physics of a soluble-boron-free (SBF) core with a time-dependent HCSG model. The predictor corrector quasi-static method was used to reduce the cost of the transient 3-D neutronic solution. In the numerical system simulations, the feedwater flow rate to the secondary of the HCSGs is adjusted to extract the demanded power from the primary loop. This varies the coolant temperature at the inlet of the SBF core, which governs the passively autonomous power maneuvering due to the strongly negative coolant reactivity feedback. Here, we simulate a 100-50-100 load-follow operation with a 5%/minute power ramping speed to investigate the feasibility of the passively autonomous load-follow in a 450 MWth SBF PWR. In addition, the passively autonomous frequency control operation is investigated. The various system models are coupled, and they are solved by an in-house Fortran-95 code. The results of this work demonstrate constant steam temperature in the secondary side and limited variation of the primary coolant temperature. Meanwhile, the variations of the core axial shape index and the core power peaking are sufficiently small.

급성 폐손상 환자에서 Adaptive Support Ventilation 적용 시 호흡지표의 양상 (Evaluation of Respiratory Parameters in Patients with Acute Lung Injury Receiving Adaptive Support Ventilation)

  • 이규성;정우영;정윤정;박주헌;신승수;황성철;박광주
    • Tuberculosis and Respiratory Diseases
    • /
    • 제70권1호
    • /
    • pp.36-42
    • /
    • 2011
  • Background: Adaptive support ventilation (ASV), an automated closed-loop ventilation mode, adapts to the mechanical characteristics of the respiratory system by continuous measurement and adjustment of the respiratory parameters. The adequacy of ASV was evaluated in the patients with acute lung injury (ALI). Methods: A total of 36 patients (19 normal lungs and 17 ALIs) were enrolled. The patients' breathing patterns and respiratory mechanics parameters were recorded under the passive ventilation using the ASV mode. Results: The ALI patients showed lower tidal volumes and higher respiratory rates (RR) compared to patients with normal lungs ($7.1{\pm}0.9$ mL/kg vs. $8.6{\pm}1.3$ mL/kg IBW; $19.7{\pm}4.8$ b/min vs. $14.6{\pm}4.6$ b/min; p<0.05, respectively). The expiratory time constant (RCe) was lower in ALI patients than in those with normal lungs, and the expiratory time/RCe was maintained above 3 in both groups. In all patients, RR was correlated with RCe and peak inspiratory flow ($r_s$=-0.40; $r_s$=0.43; p<0.05, respectively). In ALI patients, significant correlations were found between RR and RCe ($r_s$=-0.76, p<0.01), peak inspiratory flow and RR ($r_s$=-0.53, p<0.05), and RCe and peak inspiratory flow ($r_s$=-0.53, p<0.05). Conclusion: ASV was found to operate adequately according to the respiratory mechanical characteristics in the ALI patients. Discrepancies with the ARDS Network recommendations, such as a somewhat higher tidal volume, have yet to be addressed in further studies.

고속도로 교통데이터(FTMS, TCS)를 이용한 경로전환율 분석: 서해안고속도로 매송~발안 구간을 중심으로 (Analysis of Diversion Rate using Expressway Traffic Data(FTMS, TCS): Focusing on Maesong~Balan IC at Seohaean Expressway)

  • 고한검;최윤혁;오영태;최기주
    • 대한교통학회지
    • /
    • 제30권3호
    • /
    • pp.31-41
    • /
    • 2012
  • VMS, 교통방송(라디오), SNS 등 교통정보제공을 통한 교통량 분산에 대한 관심이 높아짐에 따라 교통정보에 대한 운전자의 반응행태 및 효과에 대한 연구가 지속적으로 이루어지고 있다. 본 연구는 FTMS 및 TCS 데이터가 구축되어 있는 전국 고속도로 본선부를 분석 대상으로, FTMS 데이터와 TCS 데이터를 이용하여 경로전환 교통량과 그에 따른 경로전환율을 추정하는 방법론을 제시하고, 실제 대상구간의 경로전환율을 산출하여 시간 및 공간적 경로 전환율 변동에 대한 특성을 분석하였다. 본 연구에서는 교통정보 제공 이후, 해당 시간대의 평균 유출교통량에 비해 유출교통량이 일시적으로 증가한 경우 이 편차(도로교통상황의 동적인 특성으로 인한 편차 고려)는 교통정보 제공으로 인한 경로전환 교통량이라 정의하고, 본선 교통량과의 비율을 경로전환율로 계산하였다. 시간흐름에 따른 경로전환율 변화를 분석한 결과, 혼잡상황에 대한 교통정보를 먼저 얻게 되는 상류부 IC에서의 초기 경로전환율(유출교통량) 변화는 일시적으로 매우 큰 것으로 나타났다. 이후 공간적 시간적 흐름에 따라 상류부 IC에서의 경로전환율의 변화는 하류부 IC에서의 경로전환에 영향을 미치고, 이는 다시 상류부 IC에서의 변화를 유도하는 등의 경로전환 순환체계(feedback control loop)가 있음을 확인하였다.

VANETs 환경에서 단일 교차로의 교통신호 제어방법에 관한 연구 (A study on traffic signal control at signalized intersections in VANETs)

  • 장형준;박귀태
    • 한국ITS학회 논문지
    • /
    • 제10권6호
    • /
    • pp.108-117
    • /
    • 2011
  • 서울시는 2001년부터 실시간 신호제어시스템(COSMOS)를 운영하고 있으며, 도시부 신호교차로의 신호운영 자료인 포화도 및 대기길이의 산출을 위하여 검지기를 설치해 차량으로부터 기초자료를 습득하고 있다. 현재 가장 보편적으로 사용하는 것은 유도성 루프검지기로 도로의 노면에 매설하는 방식이라 유지 보수가 용이하지 않고 비용이 많이 드는 단점이 있다. 또한 대기길이의 산정시 검지기를 통과하는 차량의 속도만으로 계산해야하기 때문에 속도측정 오차 발생시에 대기길이의 값에 영향을 미치게 된다. 제안하는 알고리즘은 카메라, 센서 및 이미지처리 장치와 같은 추가적인 장치 없이, VANETs(Vehicular Ad-hoc Networks)의 차량 간의 통신을 이용하고 각 방향별 그룹을 설정하여 교차로에서 원활한 교통 흐름을 가능케 하는 실시간 교통신호 제어 시스템을 제안한다. 본 연구에서 제안한 알고리즘은 GLD(Green Light District) Simulator를 기반으로 단일교차로 모델에서 AJWT(Average Junction Waiting Time)와 TQL(Total Queue Length) 에 대해서 확인하였으며 그 결과를 무작위(Random) 제어방식 및 최상우선(Best first) 제어방식과 비교하여 더 나은 결과를 보였다. 향후 VANETs를 활용한 실시간 제어방법이 보편화 될 경우 무선 통신기술을 이용한 교차로의 교통제어기술을 제안한 본 연구는 그 활용가치가 높을 것으로 판단된다.

가압경수로 부분충수 운전중 잔열제거 (RHR)계통 상실시 가압기 통로를 통한 배출유로 특성 분석 (Analysis of the Vent Path Through the Pressurizer Manway Under the Loss of Residual Heat Removal(RHR) System During Mid-Loop Operation in PWR)

  • 하귀석;김원석;장원표;류건중
    • Nuclear Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.859-869
    • /
    • 1995
  • 본 연구는 가압경수로의 부분충수 운전중 잔열제거기능 상실사고 해석시 신뢰성을 확보하기 위해 RELAP5/MOD3.1 코드로 관련 대형 실험을 모의 계산하여, 사고시 예상되는 주요 물리적 현상의 파악과 코드의 예측능력을 평가하는 것이다. 대상 실험으로 선택된 BETHSY Test 6.9a는 이 사고중 증기발생기가 작동하지 않고, 가압기 Manway를 개방한 상태 (Configuration)를 모의한 실험이다. 이 연구 결과는 실제 원전 사고시 예상되는 중요 현상 뿐 아니라, 이에 영향을 미치는 민감한 인자를 파악하여 사고 해석결과의 유효성을 판단하는 데 상당히 기여할 것으로 기대한다. 연구결과 RELAP5/MOD3.1 코드는 대체적으로 계통의 과도기 거동은 타당하게 예측하고 있지만, 모의계산에서 Time-Step이 아주 짧아 막대한 시간이 소요된다는 문제점이 발견되었다. 그 외에도 노심팽창수위 (swollen level)를 과대평가하여 가압기의 수위 및 계통의 압력을 높게 계산하였다. 이로 인해 가압기를 통한 방출량도 과대계산하여 노심노출을 약 400초 빨리 예측하였다. 실험과 코드 예측결과를 종합할 때 가압기 Manway 만의 개방으로는 계통압력이 상승하고, 중력주입냉각수로는 노심수위 회복에 불충분하며, 결국 강제주입에 의해서 노심수위가 회복될 수 있음이 입증되었다.

  • PDF

An Experimental Study on Heat Transfer and Pressure Drop Characteristics of Carbon Dioxide During Gas Cooling Process in a Hellically Coiled Tube

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Yu, Tae-Geun;Kim, Dae-Hui
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.263-271
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during 9as cooling process of $CO_2$ (R744) in a helically coiled copper tube with the inner diameter of 4.55 mm and outer diameter of 6.35 mm were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter a pre-heater and a helically coiled type gas cooler (test section). The refrigerant mass fluxes are varied from 200 to $800kg/m^2s$ and the inlet pressures of gas cooler are 7.5 to 10.0 MPa. The heat transfer coefficients of $CO_2$ in a helically coiled tube are higher than those in a horizontal tube. The Pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those predicted by Ito's correlation developed for single-phase in a helically coiled tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However. at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al correlation. Therefore, various experiments in helically coiled tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in a helically coiled tube.

동파방지열선 화재 흔적분석과 발화원인 연구 (A Study for the Fire Analysis and Igniting Cause of Freezing Protection Heating Cables)

  • 이정일;하각천
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.15-20
    • /
    • 2018
  • There have been a number of major fatal fire accidents in Korea recently. The number of fires in 2017 were 44,178, which is not only increasing number of fires but also increasing in casualties. Particularly, the fire at Jecheon Sports Center, which suffered many casualties, is expected to have a huge impact. The cause of the fire has not been determined yet, but heat waves on the ceiling have also been pointed out. As such, the copper heating waves, which are used as a preventive measure against damage of pipes due to freezing of pipes, etc., always have a fire hazard. To determine the possibility of a flame-resistant heated fire, a positive electric cable product was used to artificially ignite and analyze the results. In case of a short circuit, the external covering of the positive electric cable is damaged, but not short circuit unless the heating material surrounding the wire is damaged. Due to the characteristics of heating cable for preventing copper waves, the chances of insulation becoming more severe due to moisture and temperature changes are higher than normal wires. If the internal heating system is carbonized by insulating deterioration without damage to the outer coating, it is likely to cause trekking, to form a winding loop in the heating materials, and to cause short circuit in the heated materials. For the positive temperature line, if the middle is shorted, the current continues to flow to the short circuit unless the breaker disconnects. Consequently, a heated fire that does not cut off the power immediately may leave multiple marks or cuts.

Box-Wilson 실험계획에 의한 연마용 인산일수소칼슘의 최적 제조조건 추구 및 안정화 (A Study on the Optimum Conditions for Preparation of Calcium hydrogenphosphate Dihydrate by Box-Wilson Experimental Design)

  • 이계주;곽손혁;서성수
    • Journal of Pharmaceutical Investigation
    • /
    • 제26권3호
    • /
    • pp.221-232
    • /
    • 1996
  • An abrasive, calcium hydrogen phosphate dihydrate (DCPD), was synthesized in a Box-wilson experimental design by reactions between phosphoric acid and milk of lime, and calcium chloride and sodium phosphate solutions, and stabilized with TSPP and TMP. The optimum conditions for preparation of DCPD from phosphoric acid with milk of lime were such as; reaction temp.; $51.9^{\circ}C$, conc. of lime; 25.9%, conc. of phosphoric acd; 77.9%, drying temp.; $60.2^{\circ}C$ and final pH; 6.46. The physico-chemical and pharmaceutical properties of DCPD were showed as follows: glycerin absorption value(68 ml/100g), whiteness(99.5%), particle size(10.9 nm), pH(7.8), and set test(pass). XRD and SEM of DCPD indicated a monoclinic system crystallographically. $N_2$ adsorption isotherm curve by BET showed non porous type II form. The micromeritic parameters of DCPD showed that surface area was $3.27{\sim}4.6\;cm^{2}/g$ and pore volume, pore area and pore radius were negligible. The rheogram of the toothpaste containing DCPD showed pseudoplastic flow with yield value of 321, and thixotropic behavior forming hysteresis loop. These results meet the requirements as abrasive standard, and sythesized DCPD is expected as a good dental abrasive such as a high quality grade in practice.

  • PDF

소뇌 운동실조 이상 환자를 위한 운동상상 기반의 뇌-컴퓨터 인터페이스 (Motor Imagery based Brain-Computer Interface for Cerebellar Ataxia)

  • 최영석;신현출
    • 한국지능시스템학회논문지
    • /
    • 제24권6호
    • /
    • pp.609-614
    • /
    • 2014
  • 소뇌 운동실조는 점차 진행되는 신경퇴행질병이며 운동 조절을 위한 기능의 상실을 동반하기에 환자의 삶을 심각하게 저하시킨다. 소뇌 운동실조 환자는 운동제어 과정에서 부적절한 폐회로 소뇌 반응으로 인해 운동 명령이 제한된다. 본 논문에서는 최근 뇌-컴퓨터 인터페이스 기술을 이용하여 소뇌의 이상으로 인한 운동실조 환자들이 외부기기를 제어할 수 있도록 운동상상 기반의 뇌파의 특성을 분석하고 이를 이용한 뇌-컴퓨터 인터페이스 기법을 제안한다. 뇌파 기반의 뇌-컴퓨터 인터페이스의 효용성을 검증하기 위하여 소뇌 운동실조 환자와 정상인 그룹에서 운동상상에 따른 뮤밴드 파워를 조절하는 능력을 비교하였다. 이를 통하여 소뇌 운동실조 환자에의 뇌-컴퓨터 인터페이스의 가능성을 보여준다.

유전체 배리어 방전 플라즈마를 이용한 에틸렌의 분해 (Decomposition of Ethylene by Using Dielectric Barrier Discharge Plasma)

  • 장두일;임태헌;이상백;목영선;박회만
    • 공업화학
    • /
    • 제23권6호
    • /
    • pp.608-613
    • /
    • 2012
  • 유전체 배리어 방전 플라즈마를 모사 농산물 저장시설($1.0m^3$)의 에틸렌 제거에 적용하였다. 에틸렌이 포함된 공기를 플라즈마 반응기에 유입시켜 처리한 후 다시 농산물 저장시설로 재순환하는 방식으로 시험을 수행하였다. 주요 운전변수는 방전전력, 순환기체 유량, 초기 에틸렌 농도 및 처리시간이었다. 에틸렌의 분해속도는 주로 방전전력과 처리시간에 의해 결정되었다. 다른 조건을 일정하게 유지한 상태에서 플라즈마 반응기 후단에 이산화망간 오존분해 촉매를 설치했을 경우 오존분해 촉매가 없을 때 보다 에틸렌 제거속도가 더 빨랐는데, 이 결과는 플라즈마 반응기에서 배출되는 오존이 농산물 저장시설에 유입 축적되어 에틸렌을 추가적으로 분해했기 때문이다. 에틸렌 초기 농도 50 ppm을 기준으로 하면 이를 완전히 분해하기 위한 에너지 요구량은 약 60 kJ이었다.