• Title/Summary/Keyword: flow capacity test

Search Result 342, Processing Time 0.027 seconds

A Study on the Speed Performance of a Medium Patrol Boat using CFD (CFD를 이용한 중형 경비정의 속도성능 평가)

  • Park, Dong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.38 no.6
    • /
    • pp.585-591
    • /
    • 2014
  • The primary objective of the current work is to predict speed performance of the medium patrol boat over $F_N=0.5$ employing experimental materials based on the CFD before model tests. In other words, the predicted brake powers according to ship speeds are assessed satisfying the main engine capacity. The subject ships are selected the two different stern hull forms. The flow computation are conducted considering free surface and dynamic trim using a commercial CFD code(STAR-CCM+). The resistances of the bare-hull are obtained from CFD. Wave patterns, pressures and limiting streamlines on the hull and velocity distribution in the propeller plane for the two hull forms are compared using CFD. The effective powers of the object ships are assessed based on CFD. Resistance increase according to the attached appendages and quasi-propulsive efficiency are employed the experimental datas. Speed performance prediction method concerning high speed vessels like a medium patrol boat is developed employing CFD and experimental data.

A Test of Relative Removal Properties of Various Offensive Odors by Zeolite

  • Adelodun, Adedeji A.;Vellingiri, Kowsalya;Jeon, Byong-Hun;Oh, Jong-Min;Kumar, Sandeep;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.15-28
    • /
    • 2017
  • The adsorptive removal properties of synthetic A4 zeolite were investigated against a total of 16 offensive odors consisting of reduced sulfur compounds (RSCs), nitrogenous compounds (NCs), volatile fatty acids (VFAs), and phenols/indoles (PnI). Removal of these odors was measured using a laboratory-scale impinger-based adsorption setup containing 25 g of the zeolite bed (flow rate of $100mL\;min^{-1}$). The high est and lowest breakthrough (%) values were shown for PnIs and RSCs, respectively, and the maximum and minimum adsorption capacity (${\mu}g\;g^{-1}$) of the zeolite was observed for the RSCs (range of 0.77-3.4) and PnIs (0.06-0.104), respectively. As a result of sorptive removal by zeolite, a reduction in odor strength, measured as odor intensity (OI), was recorded from the minimum of approximately 0.7 OI units (indole [from 2.4 to 1.6]), skatole [2.2 to 1.4], and p-cresol [5.1 to 4.4]) to the maximum of approximately 4 OI units (methanethiol [11.4 to 7.5], n-valeric acid [10.4 to 6.5], i-butyric acid [7.9 to 4.4], and propionic acid [7.2 to 3.7]). Likewise, when removal was examined in terms of odor activity value (OAV), the extent of reduction was significant (i.e., 1000-fold) in the increasing order of amy acetate, i-butyric acid, phenol, propionic acid, and ammonia.

Experimental Investigation of Local Half-cone Scouring Against Dam under the Effect of Localized Vibrations in the Sediment Layers

  • Dodaran, Asgar Ahadpour;Park, Sang Kil;Mardashti, Asadollah;Noshadi, Mehrzad;Afsari, Mohammad
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.107-113
    • /
    • 2013
  • Most natural river reach are approximately balanced with respect to sediment inflow and outflow. Dam construction dramatically alters this balance, creating an impounded river reach characterized by extremely low flow velocities and efficient sediment trapping. The impounded reach will accumulate sediment and lose storage capacity until a balance is again achieved, which would normally occur after the impoundment has become "filled up" with sediment and can no longer provide water storage and other benefits. This paper aims to investigate the sediment removal process in dam reservoir using simultaneously pressure flushing operation and vibrator machine. The main objective of this study is to identify the effect of vibrator in flushing cone dimensions. To achieve the objectives of present study, laboratory test have conducted under different hydraulic conditions such as two bottom outlets with diameter equal to 2" and 3", five discharges 0.23, 0.53, 1.21, 1.53 and 2.1 lit/s and only one water depth above the center of bottom outlets. Using the vibrator machine mounted into the reservoir and close to the bottom outlet, different frequency e.g. 20, 35 and 50 HZ, have been introduced to the deposited sediment at the vicinity of outlet. The results indicate that the volume and width of flushing cone are strongly affected by frequency of vibrations. The results indicate that the volume and width of flushing cone are strongly affected by frequency of vibrations.

Allowable Amount of Bed Inventory in a 300 MW Class Circulating Fluidized Bed Boiler (300 MW 급 유동층보일러에서 적정 층 물질량 산정)

  • Kim, Woo-Yong;Yoo, Ho-seon
    • Plant Journal
    • /
    • v.14 no.2
    • /
    • pp.33-38
    • /
    • 2018
  • The CFB boilers technology is facing a number of challenges. Among them, boiler tube erosion, sintering by bed inventory overheating and high self consumed service power are major ones. This study was conducted to obtain allowable bed inventory with the Yeosu Power Plant, a 300 MW class CFB boiler. For the test, bed pressure was reduced from design pressure of 4.5 KPa to 2.5 KPa by reducing bed inventory, at fixed turbine output, coal consumption rate and air flow. Consequently, reducing the lower bed inventory is effective to decrease bed temperature but excessive reducing might increase bed temperature due to lack of circulating fluidized materials. Also, in case of the Yeosu Plant boiler using subbituminous coal as its primary fuel, its bed temperature change is highly affected by not only the amount of bed inventory, but also the boiler capacity and coal contents.

  • PDF

The Effects of Inspiratory Muscle Training with Chest Expansion on Pulmonary Function, Maximal Inspiratory Pressure, and Gait in Individuals with Stroke (흉곽확장을 병행한 흡기근훈련이 뇌졸중 환자의 폐기능과 최대흡기압력 및 보행지구력에 미치는 영향)

  • Back, Woon-Chang;Kim, Chang-Beom
    • PNF and Movement
    • /
    • v.16 no.3
    • /
    • pp.461-473
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate and compare the effects of inspiratory muscle training with chest expansion exercises on pulmonary function, maximal inspiratory pressure, and gait in individuals with stroke. Methods: The participants in this study included 36 stroke patients. These patients were randomly divided into three groups: an inspiratory muscle training (IMT) with chest expansion (CE) group (n=12), an IMT group (n=12), and a control group (n=12). Participants in the IMT with CE group underwent IMT and CE exercises 5 times per week for 30 minutes over 4 weeks, whereas those in the CE group and the control group received IMT and conventional physical therapy, respectively, for the same duration. The investigator measured the patients' pulmonary function, maximal inspiratory pressure, and gait endurance. Results: After the intervention, the change values for the forced vital capacity (FVC), forced expiratory volume in one second (FEV1), peak expiratory flow (PEF), maximal inspiratory pressure (MIP), and six-minute walk test (6MWT) in the IMT with CE group and the control group were significantly greater than those of the control group (p<0.05). Similarly, after the intervention, the change values of the FVC, FEV1, PEF, MIP, and 6MWT in the IMT with CE group were significantly greater than those in the IMT group (p<0.05). Conclusion: These findings suggest that IMT with CE could be used to increase pulmonary function, maximal inspiratory pressure, and gait endurance in stroke patients.

Effects of Sagittal Spinopelvic Alignment on Motor Symptom and Respiratory Function in Mild to Moderate Parkinson's disease

  • Kang, DongYeon;Cheon, SangMyung;Son, MinJi;Sung, HyeRyun;Lee, HyeYoung
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.2
    • /
    • pp.122-128
    • /
    • 2019
  • Purpose: This study examined the effects of sagittal spinopelvic alignment on the clinical parameters, motor symptoms, and respiratory function in patients with mild to moderate Parkinson's disease (PD). Methods: This study was a prospective assessment of treated patients (n=28, Hoehn and Yahr (H&Y) stage 2-3) in a PD center. Twenty-eight subjects ($68.5{\pm}5.7yrs$) participated in this study. The clinical and demographic parameters, including age, sex, symptoms duration, treatment duration, and H&Y stage, were collected. Kinematic analysis was conducted in the upright standing posture with a motion capture system. A pulmonary function test (PFT) was performed in the sitting position using a spirometer. The motor symptoms were assessed on part III of the movement disorder society sponsored version of the unified Parkinson's disease rating scale (MDS-UPDRS). SPSS 18.0 was used to analyze the collected data. Results: The exceeding 12 degrees group of the lower trunk showed significantly higher on the clinical parameters than the below 12 degrees group. In addition, the exceeding 12 degrees group of the lower trunk showed a significantly lower forced expiratory volume at one second (FEV1) / forced vital capacity (FVC) (%) and 25-75% forced mid-expiratory flow (FEF) (L/s) than in the below group. On the other hand, there was no difference in the upper trunk and the cervical pelvis between the groups. Conclusion: These findings suggest that the sagittal balance in the lower trunk is related to the clinical parameters and respiratory function, but not the motor symptoms in patients with mild to moderate PD.

Effectiveness of Exercise after Lung Cancer Surgery: A Systematic Review in PubMed Database (폐암 수술 후 운동의 효과: PubMed 내 연구에 대한 체계적 문헌고찰)

  • Jerng, Ui Min
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.31 no.1
    • /
    • pp.149-163
    • /
    • 2021
  • Objectives This study is to review the effectiveness of exercise after lung cancer surgery. Methods Relevant randomized controlled trials (RCTs) were searched in PubMed database. The systematic review was conducted through flow diagram. The risk of biases were assessed through the Cochrane guideline. Characteristics and outcomes were extracted from each study. Meta-analyses of forced expiratory volume in one second (FEV1), 6-minute walk test (6MWT), quality of life (QoL), pulmonary complications were conducted. Results 14 RCTs were selected. In meta-analysis, exercise improved FEV1 (mean difference [MD] 0.14; 95% confidence interval [CI] 0.04 to 0.25; p=0.009; I2=55%) and mean change of FEV1 (MD 0.11; 95% CI 0.02 to 0.20; p=0.02; I2=0%). Exercise increased the distance of 6MWT, but there was considerable heterogeneity (MD 45; 95% CI 21.16 to 68.83; p=0.0002, I2=89%). There was no differences in QoL scores by 2 questionnaires (European Organisation for Research and Treatment of Cancer quality of life questionnaire, short form-36). Exercise reduced the duration of hospital stay (MD -3.32; 95% CI -5.27 to -1.36; I2=0%; 2 studies) but not duration of chest tube intubation (MD -1.37; 95% CI -2.81 to 0.06; I2=0%) and incidence of pulmonary complications (pooled risk ratio 0.54; 95% CI 0.23 to 1.30; I2=0%). Conclusions Exercise might reduce the duration of hospital stay after lung surgery. There was not enough evidence to prove improvement of lung function, aerobic capacity, muscle strength, QoL, and decline of pulmonary complications. Low-quality risk of bias, different units or estimation of outcome, different exercise type and duration, heterogeneity among studies make the evidence of effectiveness weak. Future researches are required to redeem these defects.

Experimental design approach for ultra-fast nickel removal by novel bio-nanocomposite material

  • Ince, Olcay K.;Aydogdu, Burcu;Alp, Hevidar;Ince, Muharrem
    • Advances in nano research
    • /
    • v.10 no.1
    • /
    • pp.77-90
    • /
    • 2021
  • In the present study, novel chitosan coated magnetic magnetite (Fe3O4) nanoparticles were successfully biosynthesized from mushroom, Agaricus campestris, extract. The obtained bio-nanocomposite material was used to investigate ultra-fast and highly efficient for removal of Ni2+ ions in a fixed-bed column. Chitosan was treated as polyelectrolyte complex with Fe3O4 nanoparticles and a Fungal Bio-Nanocomposite Material (FBNM) was derived. The FBNM was characterized by using X-Ray Diffractometer (XRD), Scanning Electron Microscopy-Energy Dispersive X-Ray Spectroscopy (SEM-EDS), Fourier Transform Infrared spectra (FTIR) and Thermogravimetric Analysis (TGA) techniques and under varied experimental conditions. The influence of some important operating conditions including pH, flow rate and initial Ni2+ concentration on the uptake of Ni2+ solution was also optimized using a synthetic water sample. A Central Composite Design (CCD) combined with Response Surface Modeling (RSM) was carried out to maximize Ni2+ removal using FBNM for adsorption process. A regression model was derived using CCD to predict the responses and analysis of variance (ANOVA) and lack of fit test was used to check model adequacy. It was observed that the quadratic model, which was controlled and proposed, was originated from experimental design data. The FBNM maximum adsorption capacity was determined as 59.8 mg g-1. Finally, developed method was applied to soft drinks to determine Ni2+ levels. Reusability of FBNM was tested, and the adsorption and desorption capacities were not affected after eight cycles. The paper suggests that the FBNM is a promising recyclable nanoadsorbent for the removal of Ni2+ from various soft drinks.

The Effect of the Resistance Respiratory Muscle Exercise with Transcutaneous Electrical Nerve Stimulation on Respiratory Muscle Tone and Pulmonary Function of Chronic Stroke Patients (경피신경전기자극과 호흡근 저항운동 동시 적용이 만성 뇌졸중 환자의 호흡근 근긴장도와 폐 기능에 미치는 영향)

  • Cho, Yong-Hun;Cho, Kyun-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.1
    • /
    • pp.75-83
    • /
    • 2022
  • PURPOSE: This study was conducted to investigate the effect of the resistance respiratory muscle exercise with transcutaneous electrical nerve stimulation (TENS) on the respiratory muscle tone and pulmonary function of stroke patients. METHODS: Twenty stroke patients were divided into the TENS group (n = 7), placebo TENS group (n = 7), and control group (n = 6), and each intervention was performed on the three groups 5 times a week for 4 weeks. The assessment was carried out by measuring changes in the muscle tone of the latissimus dorsi and abdominal external obliques, and pulmonary function. RESULTS: In this study, the TENS group and the placebo TENS group had significant increases in the paretic side latissimus dorsi muscle tone, forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), and peak expiratory flow (PEF). There was no significant difference in changes in respiratory muscle tone between the three groups. The pulmonary function was significantly different between the three groups, and it was observed from the results of the post-hoc test that FVC showed a significant increase in the TENS group and the placebo TENS group compared to the control group. CONCLUSION: Through this study, it was found that the respiratory muscle resistance exercise was more effective as a method to increase respiratory muscle tone and pulmonary function in stroke patients than combined transcutaneous electrical nerve stimulation.

Comparison of Two pMDIs in Adult Asthmatics: A Randomized Double-Blind Double-Dummy Clinical Trial

  • Nam, Tae-Hyun;Kang, Sung-Yoon;Lee, Sang Min;Kim, Tae-Bum;Lee, Sang Pyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.85 no.1
    • /
    • pp.25-36
    • /
    • 2022
  • Background: Only a few studies directly compared the therapeutic efficacy and safety of two pressurized metered-dose inhalers (pMDIs) in asthma. We analyzed the asthma treatment outcomes, safety, and patient preferences using formoterol/beclomethasone (FORM/BDP), a pMDI with extra-fine particles, compared with formoterol/budesonide (FORM/BUD), another pMDI with non-extra-fine particles. Methods: In this randomized, double-blind, double-dummy parallel group study, 40 adult asthmatics were randomized to FORM/BDP group (n=18; active FORM/BDP and placebo FORM/BUD) or FORM/BUD group (n=22; active FORM/BUD and placebo FORM/BDP). During the two visits (baseline and end of 8-week treatment), subjects were asked to answer questionnaires including asthma control test (ACT), asthma control questionnaires (ACQ), and Quality of Life Questionnaire for Adult Korean Asthmatics (QLQAKA). Lung function, compliance with inhaler, and inhaler-handling skills were also assessed. Results: Ten subjects in the FORM/BDP group and 14 in the FORM/BUD group completed follow-up visits. ACT, ACQ, QLQAKA (a primary outcome), and adverse events did not differ between two groups. We found that the increase in forced expiratory volume in 1 second/forced vital capacity and forced expiratory flow at 25% to 75% of the pulmonary volume in the FORM/BDP group was higher than in the FORM/BUD group. Regarding preference, subjects responded that the flume velocity of FORM/BDP was higher, but more adequate than that of FORM/BUD. They also answered that FORM/BDP reached the trachea and bronchus and irritated them significantly more than FORM/BUD. Conclusion: The use of pMDI with extra-fine particles may relieve small airway obstruction more than the one with non-extra-fine particles despite no significant differences in overall treatment outcomes. Some asthmatics have a misconception about the adequacy of high flume velocity of pMDIs.