• Title/Summary/Keyword: flow capacity test

Search Result 344, Processing Time 0.022 seconds

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Control of Inverter Frequency (인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4721-4726
    • /
    • 2010
  • The performance characteristics of water-chilling heat pump using CO2 for the control of inverter frequency was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter flow type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4m length. The experimental results summarize as the following: for constant inlet temperature of evaporator and gas cooler, as mass flow rate, compression ratio and discharge pressure increases with the inverter frequency. And heating capacity and compressor work increases, but coefficient of performance(COP) decreases with the inverter frequency of compressor. As inlet temperature of secondary fluid in the evaporator increases from $15^{\circ}C$ to $25^{\circ}C$, compression ratio and compressor work decreases, but mass flow rate, heating capacity and COP increases with the inverter frequency of compressor. The above tendency is similar with performance variation with respect to the variation of inverter frequency in the conventional vapor compression refrigeration cycle.

The Effect of Acupuncture Therapy of Tian-zong (SI11) on Pulmonary Function Test of Patients with Dyspnea (천종혈(SI11) 자침이 자각적 호흡곤란 환자의 폐기능변화에 미치는 영향)

  • 주창엽;이재성;황우석;정희재;정승기;이형구
    • The Journal of Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.96-103
    • /
    • 2002
  • Objectives : Dyspnea is one of the most common symptoms that we meet, but so far there has been no research about the effects of acupuncture therapy on it. This study was performed in order to evaluate the effect of acupuncture therapy on dyspnea by means of using objective indexes. Methods : The effect of acupuncture therapy was assessed by analyzing the pulmonary function test (PFT) in 10 patients, who had suffered from dyspnea and had pain at the acupuncture point Tian-zong (SI11) when it was compressed by a finger, at our outpatient department. Each patient was treated with acupuncture therapy at both sides of Tian-zong. We compared the results of pre-treatment and post-treatment PFTs, including forced vital capacity (FVC), forced expiratory volume in one second (FEV 1.0), and peak expiratory flow rate (PEFR). Results : FVCs of pre-treatment and post-treatment PFTs were $2.23{\pm}0.34(L)$ and $2.40{\pm}0.36(L)$ respectively (P<0.01). FEV1.0s of pre-treatment and post-treatment PFTs were $1.54{\pm}0.37(L)$ and $1.65{\pm}0.41(L)$ respectively (p<0.05). PEFRs of pre-treatment and post-treatment PFTs were $3.41{\pm}1.26(L)$ and $3.93{\pm}1.42(L)$ respectively (p<0.05). Conclusions From the above data, we conclude that FVC, FEV1.0, and PEFR in dyspneic patients have been improved after acupuncture therapy of Tian-zong, so acupuncture therapy of Tian-zong may relieve the dyspnea symptom.

  • PDF

A Study of Relationship Between Engineering and Germination Characteristics of Stabilized Soils with Various Organic Contents (유기질 함량에 따른 고화토의 역학적 특성과 식생발아 특성과의 관계 분석)

  • Yun, Daeho;Kim, Yuntae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.12
    • /
    • pp.43-51
    • /
    • 2014
  • Organic matter in dredged soil has a lot of engineering problem in ground including a large settlement, crack propagation, low bearing capacity and low friction angle. From an agricultural point of view, however, organic matter contributes greatly soil quality and plant health. This paper investigated the relationship between engineering and germination characteristics of stabilized mixture consisting of different ratios of organic content (0 %, 10 %, 20 %, 30 %) for recycling dredged soil including organic matter. Several series of laboratory tests such as flow test, unconfined compressive test and consolidation test were performed to find out engineering characteristics. pH, percent of germination and growth of plants were also measured to investigate the germination characteristics. The experimental results indicated that, as organic content increased, unconfined compressive stress decreased and compression and swelling indices increased. However, percent of germination and plant growth increases as organic content increases.

Effect on Seal Tooth Clearance on Power Loss and Temperature of Tilting Pad Journal Bearing (씰 투스 간극이 틸팅 패드 저어널 베어링 손실과 온도에 미치는 영향)

  • Bang, Kyungbo;Choi, Yonghoon;Cho, Yongju
    • Tribology and Lubricants
    • /
    • v.34 no.5
    • /
    • pp.183-190
    • /
    • 2018
  • Tilting pad journal bearing is widely used for steam turbines because of its excellent dynamic stability. As the turbine capacity increases, power loss in the bearings becomes a matter of concern. Power loss in tilting pad journal bearings can be reduced by increasing the bearing clearance and reducing the pad arc length. In this study, the tilting pad journal bearing is tested by changing the seal tooth clearance to verify the static characteristics of the bearing. Bearing power loss and bearing metal temperature are evaluated to compare the bearing's performance and reliability for several test cases. The test bearing is a tilting pad journal bearing with 300.62mm inner diameter and 120.00mm active length. The bearing power loss, its metal temperature, and oil film thickness are measured and evaluated based on the rotor's rotational speed, oil flow rate, and bearing load. Test results show that a tilting pad journal bearing with large seal tooth clearance has 40% lower power loss compared with a bearing with a small seal tooth clearance. As the seal tooth clearance is increased, the power loss of the tilting pad journal bearing decreases. However, with respect to the bearing metal temperatures, a detuning point is observed that makes the minimum bearing metal temperature. Moreover, as the seal tooth clearance is increased, the oil film thickness increases due to high viscosity.

A study on the Normal Steady State Operation Characteristics of PV System Based on the Test Device (태양광전원용 시험장치를 이용한 정상상태 운용특성에 관한 연구)

  • Hasan, Md.Mubdiul;Munkbaht, Munkbaht;Kim, Byung-Ki;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.512-516
    • /
    • 2012
  • Recently the Korean government's green energy growth policy has been taken at the national level due to the sufficient supply of renewable energy. Some specific technique should be taken in consideration for the operation of the grid voltage and power quality management. In this case, there may have some chance of operational problems. Typical problems arise when grid-connected solar power produced by Pacific sunshine. The power flow in the reverse direction can create overvoltage on the distribution line and gives value of malfunction on the system. Line voltage and overvoltage adjustment practice can stop these symptoms occurred. Under these circumstances, this paper presents an interconnection test devices for photovoltaic(PV) systems composed of distribution system simulator, PV system simulator and control and monitoring systems using the LabVIEW S/W, and simulates the customer voltage characteristics considering the 3 parameters on the introduction capacity for PV systems, system configuration and Power factor. This paper also proposes a new calculation algorithm for voltage profile to make comparison between calculation values and test device values. The results show that the simulation results for the normal operation characteristics of PV systems which are very practical and effective.

  • PDF

Behavior of Elastic and Plastic Limit Loads of Thinned Elbows Observed During Real-Scale Failure Test Under Combined Load (감육엘보 실증실험에서의 탄성 및 소성 한계하중 거동 고찰)

  • Lee, Sung-Ho;Lee, Jeong-Keun;Park, Chi-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1293-1298
    • /
    • 2010
  • In most power plants, wall thinning in carbon-steel pipes due to flow-accelerated corrosion is one of the major aging phenomena, and it reduces the load-carrying capacity of the piping system. Various types of wall-thinning defects were manufactured in real-scale elbows, and monotonic in-plane bending tests were performed under internal pressure to evaluate the failure behavior of the elbows. In this paper, the behavior of elastic and plastic limit leads of locally thinned elbows in a real-scale failure test is presented. The loads determined on the basis of TES (twice elastic slope) were considered to be the limit loads of locally thinned elbows so that the integrity of the thinned elbows could be maintained, even when a small amount of plastic deformation might have occurred.

The Reduced Model Test for the Determination of Ventilation Velocity to Prevent Backflow in Uni-directional Road Tunnel during a Fire Disaster (일방향 도로터널내 화재 발생시 역류를 막는 환기속도결정에 관한 축소모형실험)

  • 유영일;이희근
    • Tunnel and Underground Space
    • /
    • v.8 no.2
    • /
    • pp.107-117
    • /
    • 1998
  • In the case of a fire disaster in a uni-directional road tunnel, it is important to determine the critical ventilation velocity to prevent the backflow travelling toward the tunnel exit where vehicles are stopped. The critical ventilation velocity is horizontal velocity to prevent hot smoke from moving toward the tunnel exit. According to Froude modelling, the model tunnel whcih was 300mm in diameter and 21 m in length was made of acryl tubes. Inner section of acryl tubes was clothed with polycarbonate. 1/20 scaled model vehicles were installed to simulate the situation that vehicles are stopped in the tunnel exit. Methanol in a pool type burner was burned in the middle of tunnel to simulate a fire hazard. In this study, the basis of determining the critical ventilation velocity is the ventilation flow rate that is able to maintain the allowable CO concentration in the tunnel section. We assumed that the allowable CO concentration was backflow dispersion index. Futhermore, We intended to find out CO distribution and temperature distribution according as we changed ventilation velocity. The results of this study were that no backflow happened when ventilation velocity was 0.52 m/s in the case of 5.75 kW. If we adapt these results of a fire disaster releasing 10MW heat capacity in real tunnel which is 400m in length, no backflow happens when ventilation velocity is 2.31m/s. After we figured out dimensionless heat release rate and dimensionless ventilation velocity of model test and those of real test to verify experimental correctness, we tried to find out correlation between experimental results of model tunnel and those of real tunnel.

  • PDF

Studies on Physicochemical Properties of Erythritol, Substitude Sugar (대체감미료 에리스리톨의 이화학적인 성질에 관한 연구)

  • Byun, Sang-Hee;Lee, Cherl-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.1089-1093
    • /
    • 1997
  • The physicochemical properties of erythritol were examined by measuring water absorption, solubility, water activity, heat stability, and viscosity compared to those of sucrose, xylitol, sorbitol and fructo-oligosaccharide. Erythritol showed the lowest water absorption and the highest water activity reducing capacity. In the solubility test of sweeteners, the saturation concentration of erythritol at $20^{\circ}C$ was 35.8%, which was the lowest solubility. Caramelization test and Maillard reaction test showed that erythritol was stabler than sucrose in heat treatment, while fructo-oligosaccharide showed the strongest reaction. The viscosity of erythritol was similar to that of other sweeteners at the same concentration (10%, 30% w/w). The viscosity of sweeteners increased exponentially with increasing concentration but decreased with increasing temperature following Arrhenius equation. The activation energy for flow of 30% erythritol solution was estimated to be 10.8 kcal/g mol.

  • PDF

Effect of Posture Correction Band on Pulmonary Function in Individuals With Neck Pain and Forward Head Posture

  • Kim, Jae-hyeon;Jeong, Yeon-woo;Kim, Su-jin
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.278-285
    • /
    • 2020
  • Background: Individuals with forward head posture (FHP) have neck pain. To correct the FHP, a posture correction band is commonly used. However, we do not know the posture correction band influenced the pulmonary function in individuals with FHP. Objects: This study aimed to elucidate the effects of the posture correction band on the pulmonary function in young adults with neck pain and FHP and to monitor how the pulmonary function changed over time. Methods: Twenty subjects with chronic neck pain and forward head posture were recruited. Subjects performed pulmonary function test four times: before, immediately, and 2 hours after wearing the postural band, and immediately after undressing the postural band. Vital capacity (VC), forced vital capacity (FVC), peak expiratory flow (PEF), and forced expiratory volume at one second (FEV1) were measured. The modified Borg dyspnea scale was used to measure each subject's responses to the posture correction band. The mixed-effect linear regression was used to the effect of the posture correction band over time. Results: There were no significant differences in VC, FVC, PEF, FEV1 values over time (p > 0.05), although all values slightly decreased after applying posture correction band. However, the score of the modified Borg scale significantly changed after wearing the postural bands (p < 0.05), indicating the subject felt discomfort with posture correction band during breathing. Conclusion: Because the posture correction band did not change the pulmonary function over time, but it induces psychological discomforts during breathing in people with FHP. Therefore, this posture correction band can be used for FHP realignment after discussion with the subjects.

Optimal Network Design Using Sensitivity Analysis for Variable Demand Network Equilibrium (가변수요 통행배정의 민감도 분석을 통한 최적가로망 설계)

  • 권용석;박병정;이성모
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.1
    • /
    • pp.89-99
    • /
    • 2001
  • The conventional studies on equilibrium network design problem(ENDP) with fixed travel demand models assume that the future OD travel demand might not be changed even if the structure and the capacity of the network are improved. But this fixed demand assumption may loose its validity in the long-range network design because OD travel demand actually shifts with the network service level. Thus, it is desirable to involve the variable travel demand which is determined endogenously in the model in the optimal network design. In this paper a hi-level model formulation and solution procedure for ENDP with variable travel demand are presented. Firstly It is considered how to measure the net user benefits to be derived from the improved in link capacities, and the equilibrium network design problem considered here is to maximize the increase of net user benefit which results from a set of lift capacity enhancements within the budget constraints, while the OD travel demands and link travel times are obtained by solving the lower level network equilibrium problem with variable demand. And secondly sensitivity analysis is carried out to find the links to which the network equilibrium flow pattern is the most sensitive. Finally numerical example with simple network is carried out to test the validity of the model.

  • PDF