• 제목/요약/키워드: flow capacity test

검색결과 344건 처리시간 0.027초

The Effect of Treadmill Training with Elastic Bands on the Chest Expansion and Pulmonary Functions of Young Adults

  • Lim, Sang-Wan;Seo, Kyo-Chul
    • 국제물리치료학회지
    • /
    • 제2권2호
    • /
    • pp.301-307
    • /
    • 2011
  • The purpose of this study was an determine whether elastic band on treadmill training might effect the chest expansion and pulmonary function of the 20's men. 40 subjects with experimental group(male: 20) and control group(male: 20) was participated in experiment. During four weeks, each group participated thirty minutes for three times per week. Subjects were assessed using pre-value and post-value measurement chest length(chest length for resting, chest expansion) and pulmonary function(forced vital capacity, forced expiratory volume at one second, FEV1/FVC, peak expiratory flow, vital capacity, tidal volume, expiratory reserve volume, inspiratory reserve volume) by the CardioTouch 3000S(BIONET, USA). These findings suggest that experimental group can be used to improve chest expansion, pulmonary function than control group. In comparison of both groups, post-test was more improved in experimental group. In conclusion, experimental group helped improving function of pulmonary volume and respiratory muscle, and thus it indicates that the functions will be more improved through the continued respiratory exercise program.

이산화탄소를 냉매로 사용하는 오토캐스케이드 냉동기의 성능에 관한 해석 및 실험 (Analysis and Experiment on The Performance of an Autocascade Refrigeration System Using Carbon Dioxide As a Refrigerant)

  • 김성구;김민수
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.411-421
    • /
    • 2001
  • The purpose of this study is to investigate the performance of an autocascade refrigeration system by simulation and experiment using refrigerant mixtures of R744/134a and R744/290 as working fluid. Variations of mass flow rate of refrigerant, compressor work refrigeration capacity and COP with respect to mass fraction of R744/134a and R744/290 mixture were presented under different operating conditions. Performance test has been executed by ASRAE standard. Experimental results show as the composition of R744 in the refrigerant mixture increases, heating and coling capacity are enhanced, but COP trends to decrease. Experimental results are compared with those from the simulation.

  • PDF

열교환방식에 따른 지열히트펌프의 난방특성에 관한 연구 (A Study on Heating Characteristics of Ground Source Heat Pump with Variation of Heat Exchange Methods)

  • 차동안;권오경;박차식
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.9-15
    • /
    • 2012
  • The objective of this study is to investigate the influence on the heating performance for a water-to-water 10RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The heating capacity and COP of the heat pump increased with increasing ground heat source temperature. As a result, compared to a refrigerant switching method, the water switching method with counter flow improves the heating capacity and COP by approximately 5% in average, respectively.

PBD공법의 품질 및 계측관리 (Quality and Measure Controls for Plastic Board Drains Method)

  • 박영목
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.133-145
    • /
    • 2001
  • This paper presents quality and measure controls of Plastic Board Drains(PBD) for improvement of soft ground. Laboratory and field tests has been carried out to evaluate the quality of PBD focussing on : discharge capacity of flow area; permeability of filter sleeve; migration of fine particles; deformed shape of PBD; consolidation of clay in the close vicinity of PBD; tensile strength of PBD; long-term consolidation behavior of clay-PBD. Test results show that the quality of PBD is sufficient to perform the improvement of soft silty and clayey ground. But, geotechnical engineer must make efforts minimizings of PBD damage and ground disturbance, continuity of drainage system during construction. Adequate monitoring system should apply at ground focussing on number, location, and accuracy of geotechnical instrumentation, measurement and evaluation of data for ground behaviour.

  • PDF

흙 필터재의 폐색으로 인한 투수성 저하 모델 개발 (Modelling of Permeability Reduction of Soil Filters due to Clogging)

  • 이인모;박영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.271-278
    • /
    • 1999
  • Soil filters are commonly used to protect the soil structures from eroding and piping. When filters are clogged by fine particles which are progressively accumulated, these may lead to buildup of excessive pore pressures also leading to instability in subsurface infrastructure. A filter in the backfill of a retaining wall, a filter adjacent to the lining of a tunnel, or a filter in the bottom of an earth dam can be clogged by transported fine particles. This causes reduction in the permeability, which in turn may lead to intolerable decreases in their drainage capacity. In this thesis, the extent of this reduction is addressed using results from both experimental and theoretical investigations. In the experimental phase, the permeability reduction of a filter is monitored when an influent of constant concentration flows into the filter (uncoupled test), and when the water flow through the soil-filter system to simulate an in-situ condition (coupled test), respectively. The results of coupled and uncoupled test are compared with among others. In the theoretical phase of the investigation, a representative elemental volume of the soil filter was modeled as an ensemble of capillary tubes and the permeability reduction due to physical clogging was simulated using basic principles of flow in cylindrical tubes. In general, it was found that the permeability was reduced by at least one order of magnitude, and that the results from the uncoupled test and theoretical investigations were in good agreement. It is observed that the amount of deposited particles of the coupled test matches fairly well with that of the uncoupled test, which indicates that the prediction of permeability reduction is possible by preforming the uncoupled test instead of the coupled test, and/or by utilizing the theoretical model.

  • PDF

내경 1.77 mm의 다중관식 가스냉각기내 CO2 전열 성능에 대한 실험적 연구 (Experimental Study on Heat Transfer Performance of CO2 in a Multi-Tube Type Gas Cooler of Inner Diameter Tube of 1.77 mm)

  • 손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제19권5호
    • /
    • pp.439-444
    • /
    • 2008
  • The heat capacity and pressure drop of $CO_2$ and coolant in a multi-tube type gas cooler were investigated experimentally. The main components of the refrigerant loop are a receiver, a $CO_2$ compressor, a mass flow meter, an evaporator and a multi-tube type gas cooler as a test section. The mass flowrate of $CO_2$ and coolant were varied from 0.06 to 0.075 [kg/s], respectively and the cooling pressure of gas cooler were from 8 to 10 [MPa]. The heat capacity of $CO_2$ in the test section is increased with the increment in mass flowrate of coolant, the cooling pressure and mass flowrate of $CO_2$. The pressure drop of $CO_2$ is decreased with the decrease in mass flowrate of coolant and $CO_2$, but decreased with increase in cooling pressure of $CO_2$. The heat capacity of $CO_2$ per unit heat transfer area of gas cooler is greatly high. Therefore, in case of the application of $CO_2$ at the multi-tube type gas cooler, it is expected to carry out the high-efficiency, high-performance and compactness of gas cooler.

유입·유출구가 일직선상인 C형 스트레이너 개발을 위한 유동특성 비교 (Comparison of Flow Characteristics for the Development of a C-Type Strainer with Its Inlet and Outlet on a Straight Line)

  • 신병균;권창희
    • 디지털융복합연구
    • /
    • 제14권11호
    • /
    • pp.257-265
    • /
    • 2016
  • 본 연구의 목적은 산업설비나 건축설비의 배관에서 불순물 유입을 막아 유동 시스템을 보호할 수 있는 스트레이너를 개발하기 위함에 있다. 스트레이너는 청수 또는 기름, 가스가 유입되는 배관라인의 밸브, 기기, 펌프 전단에 설치되는 장치로 형태에 따라 Y형, U형, T형이 있다. 본 연구에서는 Y형 스트레이너의 문제점을 파악하고 그 보다 개선된 새로운 모델 "유입․유출구가 일직선상에 있는 C형 스트레이너"를 개발하여 실물 시험을 통해 그 성능을 비교하였다. 시험은 기존 Y형과 C형 스트레이너 50A 실물을 한국표준과학연구원(KRISS) 유동실험실에서 4가지 상황별 실물시험으로 유동특성을 고찰하였다. 실험결과 C형 스트레이너가 Y형 보다 여과망이 없을 때는 74.9%, 여과망에 불순물이 없을 때는 54.5%, 불순물이 15% 쌓였을 때는 54.2%, 불순물이 30% 쌓였을 때는 52.4%가 용량계수(Kv)값이 높았다. 실물제작의 한계로 50A 한 종류만 시험했지만 결과로 볼 때 Y형보다 C형 스트레이너가 유동특성이 우수한 것으로 입증되어 향후 건축, 산업현장에서 유용하게 사용될 것으로 판단되었다.

자세교정훈련이 거북목증후군의 폐기능에 미치는 영향 (Effects of Posture Correction Training on Pulmonary Function with Turtle Neck Syndrome)

  • 장철
    • 대한통합의학회지
    • /
    • 제9권1호
    • /
    • pp.183-192
    • /
    • 2021
  • Purpose : The purpose of this study was to investigate the impact of postural correction training on pulmonary function on 28 college students suspected of turtle neck syndrome, and the following conclusions were obtained. Methods : Turtle neck syndrome suspicion 28 person were randomly divided into a posture training group (n = 14) and group that does not perform posture training (n = 14). Respiratory function was measured by SPIROVIT SP-1 and respiratory gas analyzer. The posture training group performed balloon blowing and stair climbing after 20 minutes of posture training, and the group without posture training carried out balloon blowing training and stair climbing. Five times a week and for two weeks. Results : 1. The comparison of the FVC before and after experiments caused by balloon blowing showed a higher level of effortful pulmonary function in the control group than in the experimental group. 2. Comparison of PEFs before and after the experiment by balloon blowing showed that the experimental group's peak flow rate was higher than that of the control group. 3. Comparison of the FIVC before and after experiments with balloon blowing showed that the comparison of the FIVC showed a higher level of effortless intake pulmonary function in the control group than in the experimental group. 4. The comparison of the maximum ventilation volume(VE) before and after the experimental gas measurement showed that the maximum ventilation rate of the experimental group was higher than that of the control group. 5. The comparison of pre-test and post-test heart rate(HR) by breath gas measurement showed that the heart rate of the control group was higher than that of the experimental group. Conclusion : the results of this study showed that postural correction training, balloon blowing training, and stair climbing could have a positive impact on improving pulmonary function. However, the two-week experiment conducted five times a week showed an increase in pulmonary function, but it was difficult to see the effect due to the short study period. Therefore, it is hoped that later studies will be conducted more systematically on the effects of breathing exercises on improving pulmonary function after post-postural correction training for patients with pulmonary function problems.

Oscillometry-Defined Small Airway Dysfunction in Patients with Chronic Obstructive Pulmonary Disease

  • Amit K. Rath;Dibakar Sahu;Sajal De
    • Tuberculosis and Respiratory Diseases
    • /
    • 제87권2호
    • /
    • pp.165-175
    • /
    • 2024
  • Background: The prevalence of small airway dysfunction (SAD) in patients with chronic obstructive pulmonary disease (COPD) across different ethnicities is poorly understood. This study aimed to estimate the prevalence of SAD in stable COPD patients. Methods: We conducted a cross-sectional study of 196 consecutive stable COPD patients. We measured pre- and post-bronchodilator (BD) lung function and respiratory impedance. The severity of COPD and lung function abnormalities was graded in accordance with the Global Initiative for Chronic Obstructive Lung Disease (GOLD) guidelines. SAD was defined as either difference in whole-breath resistance at 5 and 19 Hz > upper limit of normal or respiratory system reactance at 5 Hz < lower limit of normal. Results: The cohort consisted of 95.9% men, with an average age of 66.3 years. The mean forced expiratory volume 1 second (FEV1) % predicted was 56.4%. The median COPD assessment test (CAT) scores were 14. The prevalence of post-BD SAD across the GOLD grades 1 to 4 was 14.3%, 51.1%, 91%, and 100%, respectively. The post-BD SAD and expiratory flow limitation at tidal breath (EFLT) were present in 62.8% (95% confidence interval [CI], 56.1 to 69.9) and 28.1% (95% CI, 21.9 to 34.2), respectively. COPD patients with SAD had higher CAT scores (15.5 vs. 12.8, p<0.01); poor lung function (FEV1% predicted 46.6% vs. 72.8%, p<0.01); lower diffusion capacity for CO (4.8 mmol/min/kPa vs. 5.6 mmol/min/kPa, p<0.01); hyperinflation (ratio of residual volume to total lung capacity % predicted: 159.7% vs. 129%, p<0.01), and shorter 6-minute walk distance (367.5 m vs. 390 m, p=0.02). Conclusion: SAD is present across all severities of COPD. The prevalence of SAD increases with disease severity. SAD is associated with poor lung function and higher symptom burden. Severe SAD is indicated by the presence of EFLT.

임상 경두개 도플러 검사 (Clinical Transcranial Doppler)

  • 김종순;류재관
    • 대한물리치료과학회지
    • /
    • 제6권4호
    • /
    • pp.153-165
    • /
    • 1999
  • The transcranial Doppler(TCD) is a technique for measuring blood flow velocity of intracranial and extarcranial arteries. This examination based on Doppler effect which was first formulated in 1842 by the Austrian physicist Christian Doppler. In 1982, Rune Aaslid first maked 2MHz pulsed probe and recording intracranial vessels with transcranially. There are six criteria utilized in gaining positive identification of the intracranial vessels. The six criteria are as follows l)acoustical windows 2)depth of sample volume 3)direction of flow 4)spatial relationship of ACA and MCA bifurcation 5)mean velocity and 6)response common carotid artery compression and/or oscillation test. The affected factors for TCD examination are angle of insonation, posture of subject, age, gender, hematocrit, metabolic factors, and cardiac output. Clinical application of TCD are detection of stenosis, occlusion, emboli, thrombsis in intracranial and extracranial arteries and evaluation of cerebral arterovenous malformation, collateral capacity in the circle of Willis, ischemia cerebrovascular disease, stroke patient and vertebrobasilar system.

  • PDF