• Title/Summary/Keyword: flow capacity test

Search Result 345, Processing Time 0.025 seconds

Estimation of Gate Discharge Capacity by Physical Model Test and FLOW-3D (수리모형실험과 FLOW-3D를 이용한 배수갑문 통수능력 검토)

  • Park, Byong-Jun;Lee, Sang-Hwa
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.2
    • /
    • pp.168-175
    • /
    • 2008
  • In this study, we estimated the discharge capacity of Solicheon sluice gate in Gunjang national industrial complex by hydraulic physical scale model test and FLOW-3D. It was showed that the discharge capacity of gate carried by physical model test and numerical analysis was similar.

Flow capacity test of spring load safety relief valves used in LNG (LNG 선박용 spring load 안전방출밸브의 유량 성능시험)

  • Park, Kyung-Am;Lee, Saeng-Hee;Kim, Keng-Kuen;Goh, Jang-Hoon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.95-98
    • /
    • 2006
  • Many LNG ships will be constructed in Korea and the demand of safety valves is increasing. The most important performance of the developed safety relief valves for LNG ship is flow capacity. Flow capacity tests for 8 sizes of developed safety valves were conducted in the high pressure gas flow standard system in KRISS. The initial spring force adjustment was important for setting pressure of the safety valve. The procedure of data reduction and evaluation of the safety valve performance are suggested. This procedure was approved by French Bureau Veritas and Lloyd's Register.

  • PDF

Development of a Rice Circulating Concurrent-flow Dryer(III) - Performance Evaluation of 12-ton Capacity Dryer - (순환식 병류형 곡물건조기 개발(III) - 12톤 용량 건조기 성능평가 -)

  • Han, Jae-Woong
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.358-362
    • /
    • 2009
  • This study was conducted to evaluate the performance of a 12 tons capacity circulating concurrent flow rice dryer. An actual scale dryer with the capacity of 12 tons was developed to obtain a faster drying rate of 0.8~1.2%(w.b.)/h, while maintaining a lower drying energy consumption of 5,000 kJ/kg-water and achieving a drying quality that was comparable to a conventional cross-flow rice dryer. The Test-1 was conducted at $110^{\circ}C\;-\;20\;cmm/m^2$ and the Test-2 was conducted at $120-110-100-90^{\circ}C\;-\;20\;cmm/m^2$ under the same conditions as Test-1. In Test-1, the drying rate, drying energy consumption and crack ratio were 0.98 %(w.b.)/h, 4,573 kJ/kg-water and 3.2%, respectively. In Test-2, the drying rate, drying energy consumption and crack ratio were 0.74 %(w.b.)/h, 4,790 kJ/kg-water and 4.0%, respectively. The results of these tests demonstrated that this concurrent-flow dryer reached the desired drying rate, drying energy consumption and crack ratio.

STUDY ON THE CARIOGENIC FACTORS IN THE MALE KOREAN TWENTIES (20대 남성의 치아우식발생요인에 관한 연구)

  • Paik Dai-Il
    • The Journal of the Korean dental association
    • /
    • v.15 no.2
    • /
    • pp.145-151
    • /
    • 1977
  • The author performed Snyder test, estimation of salivary flow rate, salivary viscosity test, salivary buffering capacity test, M-R test, oral hygiene ability test, estimation of oral glucose clearance time and plaque reformation test in the 107 male Koreans aged form the age of 20 to 29, in order to detect and control the active cariogenic factors contributing to caries development on the individual basis. Thereafter, the data from 8 kinds of caries activity test were analysed and evaluated. The obtained results were as follows: 1. Snyder test was positive in 86.0% of total tested persons, and among those showing positive Snyder test reaction, slight caries activity was appeared in 39.1%, moderate caries activity in 23.9%, and marked caries activity in 37.0%. 2. Salivary flow rate was under the average flow amount in 53.3%. 3. Salivary buffering capacity was low in 22.4%. 5. Buffering capacity of dental plaque was high in 12.5%. 6. Oral hygiene ability was insufficient in all persons tested. 7. Oral glucose clearance time was long in 42.1%. 8. Plaque reformation rate was high in 8.4% of the 107 persons tested.

  • PDF

Theory vs. Experiment of Static Characteristics of Contrarotating Hydrostatic Journal Bearing with Overhung-Type Loads (외팔형 하중지지 이중 반전 정압 베어링의 정특성 이론 및 실험 연구)

  • 이용복;김창호;권오관;최동훈;이강복
    • Tribology and Lubricants
    • /
    • v.12 no.3
    • /
    • pp.92-99
    • /
    • 1996
  • Energy-efficient contrarotating propeller systems have been recently reviewed as one of alternative means in marine car-carrier applications. Contrarotating rotors preclude the usage of conventional plain journal bearings due to the lack of load carrying capacity. A new multi-recess hydrostatic contrarotating journal beating test facility has been designed and installed to test the static load carrying capacity. Measurements of flow rates and orbits have been investigated by testings on a overhung-type contrarotating rotor system which is supported by a hydrostatic journal bearing. Numerical results of static equilibria were compared with test results. Various contrarotating speed combinations, and supply pressure conditions were selected. The numerical predictions of orbit centers and flow rates are generally accurate.

On-site Performance Test and Simulation of a 10 RT Air Source Heat Pump

  • Baik, Young-Jin;Chang, Young-Soo;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.2
    • /
    • pp.61-69
    • /
    • 2004
  • In this study, on-site performance test of an air source heat pump which has a rated capacity of 10 RT is carried out. Since indoor and outdoor air conditions can not be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. To estimate the performance of the heat pump for other conditions, the heat pump is modeled with a small number of characteristic parameters. The values of the parameters are determined from the few measurements measured on-site during steady operation. A simulation program is developed to calculate cooling capacity and power consumption at any other arbitrary operating conditions. The simulation results are in good agreement with the experiment. This study provides a method of an on-site performance diagnosis of an air source heat pump.

STUDY ON THE SALIVARY CARIOGENIC FACTORS IN THE MALE AND FEMALE KOREAN TWENTIES (치아우식발생요인에 관한 연구 -20년대 남녀의 타액성 우식발생요인의 비교 연구-)

  • Lee, Jae-Myung
    • The Journal of the Korean dental association
    • /
    • v.15 no.8
    • /
    • pp.617-621
    • /
    • 1977
  • In order to comparatively observe the salivary cariogenic factors contributing to permanent tooth caries development in each sexes of Korean, the author performed estimation of unstimulated and stimulated salivary flow rates, salivary viscosity test, and salivary buffering capacity test in 50 males and 50 females Koreans aged form the age 20 to 29. Thereafter, the data from the four kinds of caries activity test were analysed and evaluated comparatively. The obtained results were as follows. 1. Unstimulated salivary flow rate for five minutes was 2.2ml in males and 1.7ml in females but the sexual difference was not significant statistically. 2. Stimulated salivary flow rate for five minutes was 7.1ml in males and 4.8ml in females. 3. Salivary viscosity was 1.9 in males and 1.7 in females but the sexual diffrence was not significant statistically. 4. Salivary buffering capacity was 8.5 drops in males and 6.7 drops in females 5. It seems the stimulated salivary flow rate and buffering capacity to be the anti-cariogenic factors in the occurrence of permanent tooth caries in Koreans.

  • PDF

A Study on Transport and Heat Utilization of Ice Slurries (아이스 슬러리의 수송 및 냉열이용에 관한 연구)

  • 길복임;이윤표;정동주;조봉현;최은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1065-1071
    • /
    • 2001
  • To investigate hydraulic and thermal characteristics of ice slurries in a circular tube, ice slurries were tested in a flow loop with a constant heat flux test section, for ranges of flow velocity, ice fraction and heat flux. Heat transfer coefficients and friction factors of ice slurries were calculated by measuring the outer wall temperatures of the test section and the pressure drops over the test section. Heat transfer coefficients of ice slurries were 9% higher than the heat transfer coefficients expected by Petukhov. Friction factors were about 4% lower than the friction factors expected by Petukhov. The effective thermal capacity of ice slurry with 12.8% ice fraction, was found to be about 3 times higher than the thermal capacity of water.

  • PDF

Flow and Engineering Properties of Fiber Reinforced Hwangtoh Mortars

  • Mun, Ju-Hyun;Yang, Keun-Hyeok;Hwang, Hye-Zoo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.3
    • /
    • pp.332-339
    • /
    • 2012
  • In this study, six mortar mixes were tested in order to examine the significance and limitations of hydrophilic fiber in terms of its capacity to enhance the tensile resistance of Hwangtoh mortar. Lyocell, polyamide and polyvinyl alcohol (PVA) fibers were selected for the main test parameters. The tensile capacity of mortars tested was evaluated based on the splitting tensile strength and the modulus of fracture, while their ductility was examined using the toughness indices specified in ASTM. Test results showed that the addition of lyocell and PVA fibers had little influence on the flow of the Hwangtoh mortars. To enhance the tensile capacity and toughness index of Hwangtoh mortar, it is proposed that fiber spacing above 0.0003 is required, regardless of the type of fiber.

Thickness of shear flow path in RC beams at maximum torsional strength

  • Kim, Hyeong-Gook;Lee, Jung-Yoon;Kim, Kil-Hee
    • Computers and Concrete
    • /
    • v.29 no.5
    • /
    • pp.303-321
    • /
    • 2022
  • The current design equations for predicting the torsional capacity of RC members underestimate the torsional strength of under-reinforced members and overestimate the torsional strength of over-reinforced members. This is because the design equations consider only the yield strength of torsional reinforcement and the cross-sectional properties of members in determining the torsional capacity. This paper presents an analytical model to predict the thickness of shear flow path in RC beams subjected to pure torsion. The analytical model assumes that torsional reinforcement resists torsional moment with a sufficient deformation capacity until concrete fails by crushing. The ACI 318 code is modified by applying analytical results from the proposed model such as the average stress of torsional reinforcement and the effective gross area enclosed by the shear flow path. Comparison of the calculated and observed torsional strengths of existing 129 test beams showed good agreement. Two design variables related to the compressive strength of concrete in the proposed model are approximated for design application. The accuracy of the ACI 318 code for the over-reinforced test beams improved somewhat with the use of the approximations for the average stresses of reinforcements and the effective gross area enclosed by the shear flow path.