• Title/Summary/Keyword: flow control

Search Result 7,466, Processing Time 0.041 seconds

Clinical Results of Surgical Treatment of an Isolated Complete Atrioventricular Septal Defect (완전방실중격결손증의 외과적 요법에 관한 임상적 고찰)

  • 이정상
    • Journal of Chest Surgery
    • /
    • v.24 no.2
    • /
    • pp.123-134
    • /
    • 1991
  • Twenty eight patients had undergone repair of an isolated complete atrioventricular septal defect between April 1986 and September 1990 in Seoul National University Children`s Hospital. The group comprised 13 male and 15 female patients. They ranged in age from 2 months to 8 years[mean 18.6months] and in weight from 3. 4kg to 23kg[mean 9.0$\pm$4.6kg]. They were analysed as Rastelli type A in 17 patients, Rastelli type B in 2 patients, and Rastelli type C in 9 patients. Seven patients had concomitant Down`s syndrome. All patients had large left-to-right shunt[mean pulmonary to systemic flow ratio 3.5 $\pm$2.2 ranging from 0.68 to 10.0] and high pulmonary systolic pressure[mean 74$\pm$18.8mmHg, ranging from 35 to 110]. In 11 patients, one patch technique was used to close the atrial and ventricular septal defect and 16 patients were undergone by two patch technique. We urgently managed only one patient by pulmonary artery banding whose anatomy was Rastelli type C and severe mitral regurgitation was identified. Postoperative complete A - V block was noted in 3 patients, two of whom were dead in operating room due to combined LVOTO and myocardial failure, and one patient with Rastelli type C was undergone by VVI type permanent pacemaker insertion 1wk later after two patch technique, but we had to manage him by modified Konno operation and total correction due to LVOTO and VSD leakage and severe mitral regurgitation 3 years later. Another two reoperation cases due to severe mitral regurgitation after two patch technique were undergone, one of whom we managed by mitral annuloplasty 3 months later but aggravated mitral regurgitation made us to control him by MVR 3 months later. Another one case of VSD leakage and tricuspid regurgitation was managed by total correction but she died of respiratory insufficiency 14 days later. We experienced pulmonary hypertensive crisis in 3 patients, who were dead in two cases comparing with one control case. So operative mortality is 9/27[33.6%], in one patch group of 3/11[29.2%] comparing with two patch group of 6/16[37.5%]. In summary, causes of death were pump weaning failure, myocardial failure and low cardiac output syndrome and pulmonary hypertensive crisis, resp. failure, complete AV block. Mean follow up period is 15.8$\pm$10.7 months[ranging from 3months to 37 months]

  • PDF

Estrogen activity of Silkworm (Bombyx mori) Pupa water extract and its fractions

  • Ryu, Jae-Sung;Jo, Gyeong-Jong;Jin, Jung-Woo;Yang, Hyo-Jung;Park, Yong-Il;Na, Ye-Seul;Nam, Kyung-Su;Keum, Kyung-Soo;Choo, Young-Kug
    • Advances in Traditional Medicine
    • /
    • v.8 no.3
    • /
    • pp.228-235
    • /
    • 2008
  • This study was conducted to evaluate the estrogen activity of silkworm (Bombyx mori) pupa extracts and their fractions. Powdered samples of freeze-dried silkworm pupa were extracted at room temperature (RT), $40^{\circ}C$, $60^{\circ}C$, $80^{\circ}C$, and $100^{\circ}C$ in water (D.W), chloroform, ethyl acetate, and methanol for 6h and then filtered (0.45 um). The extracts were then freeze-dried. The estrogenic activity of these extracts was then investigated by competition binding assays using estrogen receptor ${\alpha}\;(ER{\alpha})$ and $ER{\beta}$, and by evaluating their effects on the proliferation of the human breast cancer cell line, MCF-7. Among the extracts evaluated, water extracts prepared at RT showed the highest binding affinity to $ER{\alpha}$ ($IC_{50}$, 1.76 ug/ml) and $ER{\beta}$ ($IC_{50}$, 0.07 ug/ml). In addition, MCF-7 cells that were treated with 62.5 ug/ml of the RT extract showed the greatest increase in proliferation (2-fold; 1291.79%) when compared to control cells (659.82%). Next, the water extract that was prepared at RT (sample 1) was dissolved in D.W. and further fractionated using a Dowex 50W - 8X ($H^+$) column. The flow-through and wash were then pooled together and freeze-dried (sample 2). The bound materials were then eluted with 20 mM NaCl, after which they were applied to a Dowex 1X2 - 200 ($Cl^-$) column and washed with D.W. to remove the sodium ions. The eluants were then freeze-dried (sample 3). Of these fractions, sample 2 showed the highest binding affinity to ER{\alpha} ($IC_{50}$, 1.44 ug/ml) and $ER{\beta}$ ($IC_{50}$, 1.18 ug/ml). In addition, MCF-7 cells that were treated with sample 2 (15.6 ug/ml) showed the largest increase in growth (1159.39%) when compared to control cells (525.26%). Taken together, these results suggest that the fraction of the RT water extract of silkworm pupa referred to as sample 2 may be useful as a phytoestrogen.

Growth and Flowering Responses of Carnation (Dianthus caryophyllus) as influenced by Hydroponic Systems and Nutrient Solutions (재배방식과 양액의 종류에 따른 카네이션(Dianthus caryophyllus)의 생장과 개화반응)

  • 정순주;이범선;강종구;서범석
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.190-197
    • /
    • 1997
  • This study was conducted to determine the optimum hydroponic system and nutrient solution for promoting the growth and flowering of hydroponically grown carnation. DFT (deep flow technique) and NFT (nutrient film technique) systems were employed and four kinds of nutrient solution, which are Cooper solution, Yamasaki solution, balanced nutrient solution by Japanese Horticultural Experiment Station and PTG solution in the Netherlands were used and compared. pH was lowest in the PTG solution compared to the other nutrient solutions used. Plant height was highest in the DFT system in the plot of PTG solution as of 53.0 cm at 88 days after transplanting, while lowest in NFT system with Cooper solution. Stem diameter was more thickened in NFT system with PTG solution as of 7.2 mm at 88 days after transplanting. Days to flowering was shortened to 122.3 days in NFT system when PTG solution was used. This results suggested a combination of NFT system with PTG solution as optimum hydroponic system and nutrient solution for cut carnation production. Further trials as to the management of nutrient solution by glowing stages should be followed.

  • PDF

A Design and Implementation of Control and Management System for Water Culture Device using Solar Tracking Method (광원 트래킹 기법을 이용한 수경재배기 제어 관리 시스템 설계 및 구현)

  • Park, Sung-Kyun;Jung, Se-Hoon;Oh, Min-Joo;Sim, Chun-Bo;Park, Dong-Gook;You, Kang-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.2
    • /
    • pp.231-242
    • /
    • 2014
  • It is throwing the spotlight on the cultivation crops about high quality crops and productivity improvement per unit area because of rapid climate change caused by global warming. Therefore, we propose a water culture management of circulation nutrient method control system applies to solar tracking method not using traditional method of deep flow technique and artificial light source. We design it in the form of the circulation nutrient method in waterway of a certain amount of nutrient solution and water flowed into the way of circular. In addition, we design a multistage structure in pyramid shape which be possible continuous photosynthesis action to crops of water culture bottom part. Also, solar tracking method is designed five sensor method of center hole sensor method for tracking shadow of solar light not using traditional two hole, four hole sensor method. Finally, through the water culture device applies to solar light tracking method was not introduced in existing study yet, we can reduce growth speed of crops which be possible continuous photosynthesis action to crops. Moreover, We can expect high productivity of per unit area which be possible all crops can be offered growth environment of same type by using form of pyramid shape of multistage structure without top or bottom part.

Simultaneous Analysis of Bangpungtongseong-san and Its Antioxidant Effect (방풍통성산의 동시분석 및 항산화 효능 연구)

  • Seo, Chang-Seob;Kim, Ohn Soon;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.21 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Objectives : We carry out the simultaneous quantification for quality control of four components in Bangpungtongseong-san (BPTSS) sample. In addition, we assessed the antioxidant effects of BPTSS sample. Methods : The used column for separation and analysis of four compounds was Luna C18 column and column oven temperature was maintained at $40^{\circ}C$. The mobile phase for simultaneous determination consisted of two solvent systems, 1.0% acetic acid in water and 1.0% acetic acid in acetonitrile. High performance liquid chromatography-photodiode array (HPLC-PDA) method for analysis was performed at a flow rate of 1.0 mL/min with PDA detection at 254 and 280 nm. The injection volume was 10 ${\mu}L$. The antioxidant activities of BPTSS were evaluated by measuring free radical scavenging activities on 2,2'-Azinobis-3-ethyl-benzothiazoline-6-sulfonic acid (ABTS) and 1-1-diphenyl-2-picrylhydrazyl (DPPH). The inhibitory effects on low-density lipoprotein (LDL) oxidation were evaluated by the formation of thiobarbituric acid relative substances (TBARS) and relative electrophoretic mobility (REM). Results : Calibration curves were acquired with $r^2{\geq}0.9999$. The values of limit of detection (LOD) and quantification (LOQ) were 0.06-0.29 ${\mu}g/mL$ and 0.20-0.98 ${\mu}g/mL$, respectively. The amounts of geniposide, liquiritin, baicalin, and glycyrrhizin in BPTSS were 5.06, 7.33, 27.56, and 7.81 mg/g, respectively. The BPTSS showed the radical scavenging activity in a dose-dependent manner. The concentration required for 50% reduction (RC50) against ABTS and DPPH radicals were 72.51 ${\mu}g/mL$ and 128.49 ${\mu}g/mL$. Furthermore, GMGHT reduced the oxidation properties of LDL induced by CuSO4. Conclusions : The established HPLC-PDA method will be helpful to improve quality control of BPTSS. In addition, BPTSS has potentials as therapeutic agent on anti-atherosclerosis.

Effect of EC and pH of Nutrient Solution on the Growth and Quality of Single-Stemmed Rose in Cutted Rose Production Factory (절화장미 수경재배시 배양액의 농도와 pH가 생육과 품질에 미치는 영향)

  • Lee Hye Jin;Yang Eun-Young;Park Keum-Soon;Lee Yong-Beom;Bae Jong Hyang;Jeon Kyung Soo
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.258-265
    • /
    • 2004
  • The experiment was conducted to investigate the effect of EC and pH of nutrient solution on the growth and quality of the single-stemmed rose grown in a rose factory installed with hydroponic system. The growth and quality of the single-stemmed rose were not significantly different from each other with the EC of the nutrient solutions $1.0\~3.5dS{\cdot}m^{-1}$, which resulted in concluding high concentration of the nutrient solution was not necessary. The optimum range of the EC for single-stemmed rose was $1.5\~2.0dS{\cdot}m^{-1}$ considering plant growth, photosynthetic and transpiration rates. The optimum range of the pH for good plant growth without any visible physiological disorder was $4.0\~6.0$. Therefore, to keep the pH of the nutrient solution for rose low compared to other plants was beneficial for plant growth and uptake of the mineral ions.

Development of Stable Production Technique of Summer Spinach (Spinacia oleracea L.) in Soilless Culture in the Highlands (수경재배에 의한 고랭지 시금치의 여름철 안정생산 기술 개발)

  • Lee, Eung-Ho;Lee, Jong-Nam;Im, Ju-Sung;Ryu, Seung-Yeol;Kwon, Young-Seok;Jang, Suk-Woo
    • Journal of Bio-Environment Control
    • /
    • v.20 no.1
    • /
    • pp.21-26
    • /
    • 2011
  • Differences among cultivars, conditions of nutrient solution, nursing materials, and soilless culture systems were investigated to select suitable cultivar and cultivation methods for stable production of summer spinach in the highlands. The 'Quinto' spinach showed the earliest growth and highest yield. For yield increase of summer spinach, optimal solution pH was 6.0, EC was $2.0dS{\cdot}m^{-1}$, and $NH_4-N$ ratio of nutrient solution was 30 percent Stand rate of spinach in nursing seedlings, at 200-cell-tray filled with mixed nursing soil (peat : perlite = 7 : 3), was higher than those grown in urethane sponge and rock-wool plug. Yield was also 18 to 24 percent higher than those in rock-wool plug and urethane sponge. Plant length and yield of spinach in mixed substrate (peat : perlite = 7 : 3) filled nutrient film technique (MSNFT) system were longer of 18 percent, and higher of 9 percent than those in deep flow technique (DFT) system, respectively. However, changes of root zone temperature, pH and EC showed similar pattern with DFT. Therefore, growing 'Quinto' cultivar at 6.0 of pH, $2.0dS{\cdot}m^{-1}$ of EC, 30 percent of $NH_4-N$ ratio, at 200-cell-tray filled with mixed nursing soil, and MSNFT cultivation system, was the best for production of summer spinach in the highlands.

Application of Low Pressure Fogging System for Commercial Tomato Greenhouse Cooling (상업용 토마토온실 냉방을 위한 저압분무식 포그시스템의 적용)

  • Lee, Hyun-Woo;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • The objective of the present study is to identify the applicability of a low pressure fogging system for cooling commercial tomato greenhouse. In particular, the cooling system in this experiment utilizes low pressure spray nozzles which were developed in Korea recently. The experimental result that the temperature in fog-cooled greenhouse was lower than the non-cooled greenhouse showed the cooling effect by the low pressure fogging system. But because the relative humidity in fog-cooled greenhouse was comparatively low, the satisfactory cooling effect could be acquired by narrowing the space of fog nozzles and extending fogging time to supply more fog spray quantity. The variation of temperature distribution in fog-cooled greenhouse along timelag was insignificant during short time, but that was great during long period of day. This result showed the variation of temperature along timelag was slight by fog cooling but great by other factors like radiation, ventilation, air flow, etc. The advanced operation technology of fog system was required to reduce the variation of temperature along time lag. We plan to suggest the advanced installation and operation technology of low pressure fogging system for cooling commercial tomato greenhouse by further experiments in near future.

Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses (플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가)

  • Lee, Hyun-Woo;Kim, Young-Shik;Sim, Sang-Youn;Lee, Jong-Won;Diop, Souleymane
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.270-278
    • /
    • 2013
  • The objective of the present study is to provide data needed to decide covering method to be able to increase the thermal insulation and light transmittance efficiency of commercial greenhouse. The thermal insulation effect, PPF transmittance and quantity of condensation water were estimated in experimental tomato greenhouses covered with three types of coverings of single layer, air inflated and conventional double layers covering. The overall heat flow of air inflated double layers greenhouse was similar to that of conventional double layers greenhouse, but the temperature between covering material and thermal screen in air inflated double layers greenhouse was lower than that in conventional double layers greenhouse at the same outside temperature condition due to air leakage through the gap of roof vent. The overall heat transfer coefficients acquired by experiment that was performed in single layer and conventional double layers greenhouses were close to those obtained from model experiment. Even though the PPF transmittance of air inflated double layers greenhouse was lower than that of single layer greenhouse, which was greater than that of conventional double layers greenhouse. The quantity of condensation water on covering surface of single layer greenhouse was greater than that of air inflated double layers greenhouse due to lower covering surface temperature.

Changes in Water Quality and Bacterial Compositions in Culture Water of an Ozonated Flounder Farm (오존 처리한 넙치 양식장 사육수의 수질과 미생물 변동)

  • Park, Seongdeok;Kim, You Hee;Park, Jeonghwan;Kim, Pyong-Kih
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • This study assessed the effect of ozone to control pathogenic bacteria in inlet water flowing to flounder farms, establishing operational parameters of ozonation at seawater conditions. Hydraulic retention time in a reaction pipeline after ozonation was fixed at 3 minutes in a flow through system. Concentrations of total residual oxidant (TRO) by ozonation were measured according to different ozonation intensities. The oxidant reduction potential (ORP), which is indirect but enables real-time measurement, was measured in relation to TRO values. TRO values were $0.01{\pm}0.01mg\;L^{-1}$ at an ORP range of 320-410 mV, $0.07{\pm}0.02mg\;L^{-1}$ at 600 mV, and $0.16{\pm}0.03mg\;L^{-1}$ at 700 mV. A heterotrophic marine bacteria colony was reduced by 80.6-97.9%, showing the suppression effect of ozonation on total bacteria in inlet water. At an ORP range of 400-500 mV, colonies of heterotrophic marine bacteria, Vibrio spp., and gram negative bacteria were significantly reduced in outlet water from a culture tank with ongrowing flounder (230 g) at a stocking density of $8kg\;m^{-2}$. Especially, Vibrio spp. and gram negative bacteria were seldom found at 400-500 mV. The daily feeding rate was from over 0.7% to total body weight at 300-500 mV, showing better performance than that in the control. The pathogenic bacteria entering the flounder farm were effectively removed when the ORP range to 400 mV or less.