Reduced-mass Adaptive TMD for Tall Buildings Damping

  • Weber, Felix;Huber, Peter;Spensberger, Simon;Distl, Johann;Braun, Christian
    • 국제초고층학회논문집
    • /
    • 제8권2호
    • /
    • pp.117-123
    • /
    • 2019
  • Tall buildings are prone to wind-induced vibrations due to their slenderness whereby peak structural accelerations may be higher than the recommended maximum value. The common countermeasure is the installation of a tuned mass damper (TMD) near the highest occupied floor. Due to the extremely large modal mass of tall buildings and because of the narrow to broad band type of wind excitation the TMD mass may become inacceptable large - in extreme cases up to 2000 metric tons. It is therefore a need to develop more efficient TMD concepts which provide the same damping to the building but with reduced mass. The adaptive TMD concept described in this paper represents a solution to this problem. Frequency and damping of the adaptive TMD are controlled in real-time by semi-active oil dampers according to the actual structural acceleration. The resulting enhanced TMD efficiency allows reducing its mass by up to 20% compared to the classical passive TMD. The adaptive TMD system is fully fail-safe thanks to a smart valve system of the semi-active oil dampers. In contrast to active TMD solutions the adaptive TMD is unconditionally stable and its power consumption on the order of 1 kW is negligible small as controllable oil dampers are semi-active devices. The adaptive TMD with reduced mass, stable behavior and lowest power consumption is therefore a preferable and cost saving damping tool for tall buildings.

고층건물의 자연 진동실험 및 시스템판별 (Ambient Vibration Testing and System Identification for Tall Buildings)

  • 조순호
    • 한국지진공학회논문집
    • /
    • 제16권3호
    • /
    • pp.23-33
    • /
    • 2012
  • 구조물의 특성치를 결정하기 위하여 18층 규모의 사무용 건물 3동에 대하여 자연진동 조건하에서 동적계측실험을 수행하였다. 대상건물은 기본적으로 보-기둥 골조시스템에 횡하중을 보다 효율적으로 지지하기 위하여 추가적으로 코아가 배치된 혼합 구조형식을 나타낸다. 매층 마다 측정한 일련의 진동기록으로부터 고유진동수, 모드형태 및 감쇠율 등과 같은 모달계수를 추출하기 위하여 최신 주파수- 및 시간영역-기반 응답의존 시스템판별법인 FDD, pLSCF 및 SSI를 적용하였다. 3방법에 의하여 추출한 결과는 대체로 일치하였으나, 초기 FE 해석결과와 비교하여 저차 3개 고유진동수는 대략 1.2~1.7배나 되는 단단한 거동을 나타냈다. 진동응답으로부터 추출된 값, 기준에서 제시하는 약산식 및 FE해석에 의하여 산정된 고유주기를 비교하여 보면, FE결과가 가장 유연한 거동을 예측하였으며, 높이를 변수로 하는 약산식이 추출된 값에 가장 근접한 결과를 나타냈다. 이러한 차이는 현재의 실험 추출치에는 콘크리트 균열 등과 같은 강성저감 요인을 포함하고 있지 않으며, 또한 FE 해석치는 비구조체 및 사용된 재료의 실제성능 등과 관련된 강성증가 요소를 포함하고 있지 않기 때문이다.

경기장 관람석의 효율적인 진동해석 (Efficient Vibration Analysis of Stadium Stands)

  • 김기철;이동근
    • 한국전산구조공학회논문집
    • /
    • 제15권2호
    • /
    • pp.293-303
    • /
    • 2002
  • 고장도 재료의 사용과 시공기술의 발달로 경기장 관람석이 장경간화 유연화 되어 구조물의 고유진동수가 매우 낮아지고 있다. 경기장 관람석구조물은 사람의 율동적인 움직임에 의하여 공진 또는 공진과 유사한 거동이 일어날 수 있으므로 진동에 대한 구조물의 안전성 및 사용성에 대한 검토가 요구된다. 경기장 관람석의 효과적인 설계를 위해서는 경기장 관람석에 가해지는 동적하중에 대한 분석과 경기장 관람석의 거동에 대한 정확한 분석이 있어야 한다. 경기장 관람석에 가해지는 동적하중은 매우 다양하며 수식적으로 표현하기가 쉽지 않기 때문에 계측한 동적하중을 적용하는 것이 바람직하다. 그리고 판요소로 이루어진 경기장관람석의 정확한 진동해석을 위해서는 구조물을 조밀하게 나누어야 하기 때문에 해석시간이 길어지게 된다. 또한 경기장 전체 구조물의 진동해석에 있어서 경기장 전체 구조물을 세분화하여 모델링하는 것은 매우 어려울 뿐만 아니라 절점 수가 매우 많아지므로 절점수가 제한되어 있는 상용프로그램으로는 해석이 불가능할 수도 있다. 본 연구에서는 경기장 관람객의 여러 가지 움직임에 의하여 야기되는 다양한 동적하중을 계측하여 분석하였다. 그리고 판요소로 이루어진 경기장 관람석의 동적특성을 비교적 잘 표현할 수 있으면서도 절점을 줄일 수 있는 효과적인 해석방법을 제안하였다. 제안된 방법의 정확성과 효율성을 살펴보기 위하여 경기장 관람석의 진동해석을 수행하였다.

모형실험을 활용한 저수심 사질토 지반에서 원형강관 설치 석션압 평가 (Evaluation of Suction Installation for the Circular Pipe into Low-water Sandy Ground via Model Test)

  • 신진화;김재현;이주형
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.1-10
    • /
    • 2021
  • 본 연구에서는 해상(수상) 교량기초 시공 시 석션압으로 간편하게 설치될 수 있는 원형관 공법을 개발하고자, 실내 모형실험을 통하여 저수심 모래지반에 원형관 관입 시 설치 석션압을 평가하였다. 포화된 사질토의 반복실험을 위해 3개의 진동발생기를 활용한 진동다짐 토조 시스템을 구축하였고, 지반강도 확인을 위하여 소형 콘관입 장비를 활용하였다. 진동다짐 토조 시스템은 내부의 모래지반에 반복적으로 진동을 가하여 효율적으로 균질한 모래지반을 확보할 수 있었다. 다양한 지름과 두께를 가지는 원형관 모형체를 제작하고, 다양한 수심조건에 대하여 석션관입 실험을 수행하였다. 실험을 통한 석션압 분석결과 원형관의 관입깊이가 커짐에 따라 석션압은 커지고 지름이 클수록 원형관을 관입시키는데 필요한 석션압은 작아지는 것을 확인하였다. 특히, 수위가 낮을수록 석션관입을 위해 원형관 내부에서 끌어 올려야 하는 수두가 커지는 반면, 높아진 수두에 의한 물의 무게는 원형관의 전체 자중을 증가시켜 관입에 필요한 석션압은 작아짐을 알 수 있었다. 따라서, 저수심 조건에서 석션압을 이용하여 원형관을 설치할 경우 수심의 영향을 고려하여 설계 석션압을 결정해야 할 것으로 판단된다.

인접구조물의 진동제어를 위한 선형감쇠시스템의 최적설계 (Optimal Design of Linear Viscous Damping System for Vibration Control of Adjacent Building Structures)

  • 박관순;옥승용;고현무
    • 한국지진공학회논문집
    • /
    • 제10권3호
    • /
    • pp.85-100
    • /
    • 2006
  • 이 논문에서는 서로 다른층 높이를 갖는 인접한 두 빌딩의 내진성능을 효율적으로 향상시킬 수 있는 선형 점성 감쇠기의 최적 설계방법을 제시하고자 한다. 이를 위하여 층간 대각 브레이싱 형태의 에너지 소산장치 연결방법과 인접 구조물간 에너지 소산장치 연결방법을 고려하였으며, 두 가지 연결방법을 적용한 시스템에 대한 감쇠용량별 주파수응답함수 비교를 통하여 구조물간 연결방법의 효율성을 확인하였다. 아울러 구조물간 연결방법에서 주파수응답함수를 최소화하는 최적 감쇠용량이 존재하는 것을 보이고, 최적 설계된 시스템에 대하여 감쇠용량별 구조물의 고유주파수 및 등가감쇠비의 민감도를 분석하였다. 민감도 분석 결과로부터 고층부에 설치되는 에너지 소산장치가 구조물의 등가 감쇠비를 효율적으로 증가시키는 것을 확인하였다. 따라서 민감도에 비례하는 새로운 감쇠기 설계방법을 제시하고, 대각 브레이싱 연결방법과 구조물간 연결로서 균등분포 및 제시하는 민감도 기반 분포에 따른 연결방법을 적용한 시스템들의 내진성능을 비교 분석하였다. 지진응답의 비교결과, 제시하는 방법이 인접 구조물의 효과적인 내진설계방법이 될 수 있음을 입증하였다.

Semi-active storey isolation system employing MRE isolator with parameter identification based on NSGA-II with DCD

  • Gu, Xiaoyu;Yu, Yang;Li, Jianchun;Li, Yancheng;Alamdari, Mehrisadat Makki
    • Earthquakes and Structures
    • /
    • 제11권6호
    • /
    • pp.1101-1121
    • /
    • 2016
  • Base isolation, one of the popular seismic protection approaches proven to be effective in practical applications, has been widely applied worldwide during the past few decades. As the techniques mature, it has been recognised that, the biggest issue faced in base isolation technique is the challenge of great base displacement demand, which leads to the potential of overturning of the structure, instability and permanent damage of the isolators. Meanwhile, drain, ventilation and regular maintenance at the base isolation level are quite difficult and rather time- and fund- consuming, especially in the highly populated areas. To address these challenges, a number of efforts have been dedicated to propose new isolation systems, including segmental building, additional storey isolation (ASI) and mid-storey isolation system, etc. However, such techniques have their own flaws, among which whipping effect is the most obvious one. Moreover, due to their inherent passive nature, all these techniques, including traditional base isolation system, show incapability to cope with the unpredictable and diverse nature of earthquakes. The solution for the aforementioned challenge is to develop an innovative vibration isolation system to realise variable structural stiffness to maximise the adaptability and controllability of the system. Recently, advances on the development of an adaptive magneto-rheological elastomer (MRE) vibration isolator has enlightened the development of adaptive base isolation systems due to its ability to alter stiffness by changing applied electrical current. In this study, an innovative semi-active storey isolation system inserting such novel MRE isolators between each floor is proposed. The stiffness of each level in the proposed isolation system can thus be changed according to characteristics of the MRE isolators. Non-dominated sorting genetic algorithm type II (NSGA-II) with dynamic crowding distance (DCD) is utilised for the optimisation of the parameters at isolation level in the system. Extensive comparative simulation studies have been conducted using 5-storey benchmark model to evaluate the performance of the proposed isolation system under different earthquake excitations. Simulation results compare the seismic responses of bare building, building with passive controlled MRE base isolation system, building with passive-controlled MRE storey isolation system and building with optimised storey isolation system.

면진층을 가지는 1/10 축소된 15층 무량판 아파트건물의 진동대 실험 (Shaking Table Test of a 1/10 Scale Isolated Fifteen-story Flat Plate Apartment Building)

  • 천영수
    • 토지주택연구
    • /
    • 제2권3호
    • /
    • pp.287-297
    • /
    • 2011
  • 본 논문은 적층고무형베어링을 갖는 15층 면진 무량판 아파트건물의 내진거동을 진동대실험을 통하여 검증한 결과를 제시하고 있다. 진동대실험은 중국의 CABR에서 1/10규모의 모형실험체를 대상으로 수행되었다. 실험의 진행은 4개의 지진파를 이용하여 X, Y, X+Y방향으로 다양한 크기의 지진동이 입력되었다. 실험결과, 비 면진건물은 중진레벨에서 진동주기가 현저히 감소하고, 비선형적인 거동을 보였으며, 가속도가 건물의 높이에 따라 현저하게 증가하고, 층간변위도 허용한계를 넘는 거동을 보였다. 반면, 면진건물은 중진레벨에서 거의 일정한 진동주기의 탄성적인 거동을 나타내었으며, 지진하중과 층 가속도가 현저하게 감소하는 응답을 나타내었다. 또한 면진층의 변위는 허용범위 내에서 거동하고, 층간변위는 무시할 수 있을 만큼 작은 강체거동을 나타내었다. 결론적으로 면진은 건물에 대한 지진의 영향을 감소시키는데 매우 효과적이며, 층 가속도의 감소를 통하여 사용성을 증가시키고, 건물 내 설비 등을 안전하게 보호할 수 있음이 입증되었다.

LRB를 이용한 병렬전단벽 구조물의 지진응답제어 (Seismic Responses Control of Coupled Shear Wall Structures Using LRBs)

  • 박용구;김현수;고현;김민균;이동근
    • 한국지진공학회논문집
    • /
    • 제14권6호
    • /
    • pp.1-9
    • /
    • 2010
  • 대부분의 전단벽 구조물은 통로의 목적으로 개구부를 필요로 하게 되고 전단벽들 사이가 슬래브나 연결보로 연결된 병렬 전단벽의 형태를 띠게 된다. 이러한 구조물에 지진하중이 작용할 때 연결보에 과도한 전단력이 작용하여 연결보가 취성적으로 파괴되거나 전단벽이 먼저 항복하는 문제점이 발생할 수 있다. 이를 방지하기 위하여 연결보에 감쇠장치를 설치하게 되면 구조물의 진동제어효과와 더불어 연결보의 응력집중 및 취성적 파괴를 막을 수 있어서 내진성능 향상을 기대할 수 있다. 본 논문에서는 병렬전단벽 연결보 중앙부에 LRB (Lead Rubber Bearing)가 설치된 구조물의 지진응답제어효과 및 응력의 분포를 평가하여 구조적 효율성을 확인하고자 한다. 이를 위하여 병렬전단벽의 거동을 비교적 정확하게 모사할 수 있는 모형화 방법을 제안하였고, 제안된 모형화 방법을 통하여 지진하중을 받는 예제 병렬구조물에 대한 시간이력해석을 수행한 후 지진응답제어성능을 검토하였다.

지반 탁월주기와 지반 운동특성에 관한 연구 (A Study on Predominant Periods and Attenuation Characteristics of Ground Motion)

  • 김소구;차정식;정형식
    • 한국지반공학회지:지반
    • /
    • 제11권2호
    • /
    • pp.139-156
    • /
    • 1995
  • 지반진동특성의 지진공학적인 정밀측정의 일환으로 지반진동의 탁월주기와 지반진동의 거리에 따른 감쇠특성을 현장실험을 통하여 조사하였다. 이 조사는 세가지 부분의 실험을 통하여 결과를 얻었다. 첫째, 지반의 탁월주기는 고감도 디지탈 속도지진계-3축성분 속도계를 이용하는 Seismometer와 디지탈 Seismograph를 이용하여 지반과 건물에서 일정한 주기를 가진 연속적인 미소진동으로 부터 지반 및 건물진동의 탁월주기를 계측하였다. 지반에서의 탁월주기는 0.18~0.23 sec, 건물2층의 탁월주기는 0.26~0.31 sec였다. 둘째, 지반 구조조사는 디지탈 탄성파탐사기를 이용하여 굴절법을 이용한 탄성파탐사를 실시하였다. 실험장소인 한양대학교 안산캠퍼스의 지층구조는 상부층(표토층: surface layer)은 저속도층으로서 662m1s, 하부층(지반층: base ground)은 2210m/s의 P파 속도를 갖고, 주시곡선도로부터 표토층의 두께는 약 7m로 검측되었다. 이것은 7m두깨의 표토층(top soil)과 그 하부에 사질 점토성의 지반층(base ground)이 존재함을 암시한다. 셋째, Seisgun을 이용하여 인공적인 탄성파 에너지원을 만들어 지반의 진동 감쇠특성을 조사 하였다. 거리 감쇠상수(spatial attenuation conf$\ulcorner$icient) Y는 거리에 따른 진폭 을 계산하여 Z-성분(vertical)은 0.0137, X-성분(longitudinal)은 0.0025, Y-성분(transverse)은 0.0290이고 Spatial QP의 값은 각각 5.913~7.575, 32.371 ~41.452, 2.794~3.579의 값이 산출되었었다. 이 결과 다른 두성분에 비해서 종방향(z-성분, longitudinal)성분은 감쇠경향이 낮음을 알 수 있다. 그러므로 이 경우에 구조물 설계시 종방향(x-성분, longitudinal)성분에 대 한 내진설계가 고려 되어야 할 것이다.

  • PDF

휴게음식점 주방의 환경위생상태에 관한 조사연구 - 계절별 변화를 중심으로 - (A Study on the Sanitary Condition of Kitchens in Food Court/Cafeterias - An Observation on Seasonal Variations)

  • 김종규;박정영;김중순
    • 한국환경보건학회지
    • /
    • 제38권2호
    • /
    • pp.118-127
    • /
    • 2012
  • Objectives: This study was undertaken to assess the sanitary conditions in the kitchens of food court/cafeterias and determine seasonal variations. Methods: We measured environmental factors (air temperature, relative humidity, illumination intensity, noise level), and dropping airborne microbes (bacteria and fungi) in the kitchens of eight food court/cafeterias in four seasons (January, April, July, and October). Air temperature and relative humidity were measured with in/out thermo-hygrometers at 1.2-1.5 m above floor level. Illuminance measurement was performed through the multiple point method of Korean Standards (KS). Noise level was measured by the standard methods for the examination of environmental pollution (noise and vibration) of Korea. The estimation of dropping airborne bacteria and fungi was performed through use of Koch's method. Results: The highest kitchen air temperature was in July, and the lowest in January. The average temperature surpassed $21^{\circ}C$ throughout the seasons, suggesting a higher temperature than required for the safe handling of food. Humidity in all the kitchens was measured in the range of 50-60%. Half of the kitchens showed illumination intensities below 300 Lux in April. It was found that the sound pressure level of noise in almost all of the kitchens was higher than 85 dB (A). The highest levels of dropping airborne bacteria and fungi were noted in July. The numbers of airborne bacteria were higher than those of fungi. The levels of dropping airborne bacteria and fungi were affected by air temperature, relative humidity, season, and place. Conclusions: This study indicates that the kitchen environments were unqualified to supply safe food. The hygiene level of the kitchens should be improved.