• Title/Summary/Keyword: floor finishing material

Search Result 71, Processing Time 0.025 seconds

The Optimum Binder Ratio for High-Strength Self-Leveling Material (고강도 Self-Leveling재의 최적 결합재비)

  • 김진만
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.67-76
    • /
    • 2002
  • Self-leveling material(SLM) is one of the floor finishing materials which make flat surface like as water level by itself in a short time. So it is possible to increase construction speed and enhance economical efficiency. In this study, author intended to develop SLM for the industrial warehouse and factory loading heavy weight machinery and vehicles. The demanded properties for this type of SLM are above 20mm of flow value and above 300kgf/cm2 of 28-days compressive strength. To possess demended strength and fluidity, SLM have to be composed of many types of binders and chemical additives. So it is difficult to decide suitable mixing proportion of composition materials. In this study, author investigated the weight percentage effect of main composition materials for high-strength self-leveling material, by experimental design such as tables of orthogonal arrays and simplex design, and by statistical analysis such as analysis of variance and analysis of response surface. Variables of experiments were ordinary portland cement(OPC), alumina cement(AC), anhydrous gypsum(AG), lime stone(LS) and sand, and properties of tests were fluidity of fresh state and strength of hardened state. Results of this study are showed that suitable mix proportions of binders for the high strength self-leveling materials are two groups. One is 78~85.5% OPC, 7.5~9.5% AC, 9~12.5% AG and the other is 72.5~78% OPC, 9~12.5% AC, 13~l5% AG.

  • PDF

A Study on the Finishing Material terms analyzed the Building Specifications in Chosun Dynasty - limit the palace construction work - (조선조 영건의궤를 통한 수장재 용어에 관한 연구 - 궁궐건축을 중심으로 -)

  • Hong Seok-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.2 s.49
    • /
    • pp.12-19
    • /
    • 2005
  • After an important construction work in Chosun dynasty, the appropriate government made out the building specification as it called 營建儀軌. They are recorded about variety matters as the appointed days, various official documents, managers and craftsmen, etc.. Sometimes we can see the attached pictures about some building or furniture. specifications in Chosun dynasty about the unit of materials and history of each terms. The results are as followings: (1) The interior materials are classified to several units such as Gai(箇;the unit of square lumber or log), Rip(立;the unit of plates), Boo(部;the unit of assembled materials), etc.. (2) The terms are defined and enlightened how to use and how to change. Particularly, the terms are different positively in constituent units of wooden floor. So, it is expected to continuant study.

Characteristics of Volatile Organic Compounds Emitted in Building Materials and Their Predictions of Time-dependent Variation

  • Pang, Seung Ki;Sohn, Jang Yeul;Lee, Kwang Ho
    • Architectural research
    • /
    • v.7 no.1
    • /
    • pp.19-26
    • /
    • 2005
  • Unlike other countries, Korea uses various kinds of wall-paper as finishing material. Conventional wall-paper consists of paper and vinyl, and petrochemical ink is used for the decoration of the surface. Adhesive is used to paste the wall with the wall-paper, which emit substantial amounts of VOCs and formaldehyde. In this study, VOCs characteristics emitted from specimens made of concrete, mortar, gypsum board and wall-paper were investigated using small chamber method. Moreover, concentration and emission factor of BTEX(Benzene, Toluene, Ethylbenzene, m,p,o-Xylene) and TVOC were investigated, and concentration and emission factor decay were estimated. As a result of the prediction, both time-dependent concentration decay and cumulative concentration can be converted into the logarithmic scale. Furthermore, prediction equations were developed from the experimental results under accurately controlled experimental conditions. Therefore, there may be difference if the estimated equations are directly applied to real buildings. Further research should be done on the generalization of the developed prediction equations.

A study on the improvement for performance of floor finishing materials using poly urethane with water reacting urethane (수반응 우레탄과 바닥용 경질 폴리우레탄을 이용한 바닥마감재의 성능향상에 관한 실험적 연구)

  • Kang, Hyo-Jin;Park, Jin-Sang;Park, Jong-Ook;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.653-656
    • /
    • 2006
  • It is necessary for the new material and construction concept to make up for weak point which related to high durability and finish ability to solve exposure limit of exist construction method. This paper is deal with performance test(tier load, anti abrasion, anti impact, permeability, bond test) compositive using for water reacting soft urethane and rigid urethane to improve the exist problem which are crack movement, adhesive on the wet surface, impact and abrasion by tier load. It is getting decreasing demage compare with other exist materials after test by transfer load, movement and impact.

  • PDF

Analysis of Environment-friendly Characteristics in the Environment - friendly Housing Certification (친환경 인증단지에 적용된 친환경적 계획특성 분석)

  • Lee, Song-Hyun;Hwang, Yeon-Sook
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.181-184
    • /
    • 2005
  • The awareness of ecological friendliness has been emerging in the recent years, and the application to housing is quite notable. The purpose of this study is to evaluate environment-friendly planning factor in Environment-friendly Housing Certification. For this purpose, this study has analyzed 5 multi-family housing in Environment-friendly Housing Certification. The findings of this study are as follows: The application of environment-friendly planning factor in interior space are limited. Most of plans are located in south. The variability of floor plan is not applied but the built-in storage is well-applied. Environment-friendly finishing material and the garden-style balconies was applied in a passive way. This analysis showed current status of planning factor of unit apartment in Environment-friendly Housing Certification and proved basic information for future direction.

  • PDF

An Experimental Study on Material Property of Parking Zone Flooring Occupancy Surface Finishing Used to Environment-friendly.High-liquidity Ceramic Resin Mortar (친환경.고유동 세라믹 수지 모르타르를 이용한 주차장 바닥용 표면 마감의 재료적 특성에 관한 실험적 연구)

  • Lee, Sun-Gyu;Moon, You-Seok;Lee, Hyung-Jun;Lee, Wan-Hwi;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.829-832
    • /
    • 2008
  • Since the early 1980s, the building is dramatically higher increases. Therefore, the shortage of parking spaces as a social problem has been pointed out. The parking lot utilization of underground space is increasing by like this problem solving countermeasure. However, Most of the organic material is used for construction in the parking lot on the floor. The existing parking zone flooring occupancy surface finishing is harmful gases and environmental hormones cause of the worker. The study on the safety of the worker consider using environment-friendly?high-liquidity ceramic resin mortar materials to evaluate the characteristics and physical properties.

  • PDF

A Study on the comparison of Infill Technology between Korea long life Apartment Mock up House and Japan KSI experimental House (국내 장수명 공동주택 Mock-up House와 일본 KSI 실험주택 인필 요소기술 비교 연구)

  • Choi, Young Ho;Kim, Shin;Kim, Sung Wan
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.63-69
    • /
    • 2008
  • The thesis is a comparative analysis of Infill Technologies between Korea's long-life Mock-up House, a study driven by 'Durability and Flexibility of Long-life Housing Technology Development' of R&D, and Japan's KSI experimental house, the major example of Japan's long-llfe housing. In terms of the domestic Mock-up House, a system of building the floor first was applied. The floor material of each housing unit required a development of dry heating component that is partially substitutable in order to avoid conflict with the finishing. Also, a development of a floor system that can counteract against the construction inaccuracy was required. In the Case of an outer wall, need to make the wall with the chassis. In the case of ceiling, need to develop the double ceiling system which is good for sound insulation. Also, in comparison to KSI experimental house in Japan, it would require to develop a wiring system of the ceiling which can react to the movement of the wall. Especially, to assure the flexible nature of an internal wall, it would desperately require the research and development of the products related to components and flexible system of mechanical/electrical/communication parts as well as supporting institutionalized system for this development. Furthermore, for KSI experimental house in Japan, it would be necessary to formulate a construction manual as well as a systematic and practical planning guide to invent a new interface rule which will secure simplicity of assembling, dismantling, installation and replacement of architectural components for which research development is quite insignificant at the moment. This effort will have to continue to give a solid direction for better application of such reference manual during construction and development of long life span apartment by public sector as well as private corporations.

Evaluation of the Radon Contribution Rate in Apartments through Evaluation of the Radon Exhalation Rate from Building Materials (건축자재 라돈 방출률 평가를 통한 공동주택 내 라돈 기여율 평가)

  • Hong, Hyungjin;Choi, Jiwon;Yoon, Sungwon;Kim, Heechun;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.425-431
    • /
    • 2021
  • Background: This study evaluated the radon contribution rate through an evaluation of the exhalation rate of radon from building materials. Objectives: This study compared and evaluated the computation of the radon contribution rate based on each different exhalation rate in a building. Methods: The six demonstration houses that are the subject of this study are wall structures or Rahmen structures, and include demonstration houses similar to general residential environments and non-finishing houses with some walls exposed. Results: The highest exhalation rate was found at 62.98 Bq/m2 per day from the non-finishing floor, and the second highest exhalation rate was from stone materials at 58.76 Bq/m2 per day. Based on this result, investigating the contribution rate of building materials derived from building materials among indoor radon concentrations, house three was the highest at 81.7%, and house one was confirmed to be 33.96%. Conclusions: It can be judged that the effect of exposed concrete and stone is high, and that it is possible to reduce radon emitted from indoor building structures by controlling the indoor materials.

Changes of Housing Styles in the Anbang of the Traditional Korean Farm House - After 1950 in Kyongki Province - (한국 전통 농가 안방의 주생활 변화과정 - 1950년대 이후 평택군 오성면의 농가를 중심으로 -)

  • 고도임
    • Journal of the Korean Home Economics Association
    • /
    • v.31 no.3
    • /
    • pp.197-212
    • /
    • 1993
  • The purpose of this study was to find out the physical change of the farm house and its anbang(the main room : master bed room), to identify the behavioral changes : activity and awareness of anbang, and to clarify the relationship between the physical changes of the farm house, and the behavioral changes of housing life-style in the anbang space. Bibliographical studies, cultural approaches and field survey method with questionnaire were used to collect data from 55 residents of Anwhari and Yangkyori in Pyong Teck Koon. Tables and drawings were made to analyze the data. The major findings were 1) the heating system of the ondol anbang. The most popular type is the double heating system(new pipes added to the traditional ondol). This combination ondol system brought some conviniences to the farmers. This change in structure of the ondol were of four types : Complete change in style, enlarged-completely changed style, partially changed style, enlarged-partially changed style. 2) from 1960 through 1970 lighting of the anbang changed room oil lamp to electricity. 3) the finishing material of the anbang floor changed from traditional oil paper and straw mats to vinyl flooring. 4) Traditional furniture and small decor items are gradually disappearing and are being replaced by modern items. 5) The awareness and actual use of the ondol anbang has not much changed from the multi-functional and sacred space of daily living : which are the characteristics of Korean traditional ondol anbang. The biggest consistency in the ondol anbang is the heating system of the floor, which is the characteristic of ondol culture in Korea. This system will continue regardless of time and place in Korea.

  • PDF

A Study on Combustion Characteristics of Finishing Materials in Interior Decoration (실내장식물 인테리어마감재의 연소특성에 관한 연구)

  • Cho, Kwang-Hyun;Lee, Bong-Woo;Yun, Mung-Oh
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.4
    • /
    • pp.10-18
    • /
    • 2019
  • The Interior finishing materials tried to evaluate the combustion characteristics and the dangerous characteristic of Floor finish and Wall finish. We often use, conducting the experiment ISO 5660-1, Cone Calorimeter method, and ISO-TR-9122 FT-IR. According to the result of Cone calorimeter experiment, the tile carpet FF3 of Floor material had the highest THR $74.6mj/m^2$ because of the highest risk, and the PHRR of FF1 was $726kW/m^2$, which was easy to bum. As a result FT-IR test, The CO, $CO_2$ ratio was 8,146 PPM for roll carpet FF1 than tile carpet FF2, FF3 5,996, 5,171 PPM, which was a carpet with a high toxicity risk. In the case of wall finishes, The MDF plate(WF3) was THR $86.7mj/m^2$ with a high risk, PHRR $384kW/m^2$ was easy to ignite and toxicity index was 5.5. The CO, $CO_2$ ratio was 1,340~8,596 PPM, But the WF4 was the most toxic with 8,596 PPM.