• Title/Summary/Keyword: floc

Search Result 222, Processing Time 0.029 seconds

Effect of Coagulated Flocs Broken by the Pressure Pump on Removal Rate and Membrane Fouling of Pressurized MF process (가압펌프에 의해 해체된 플럭이 가압식 막여과 공정의 제거효율 및 막오염에 미치는 영향)

  • Kim, Junhyun;Moon, Baeksu;Park, Jongsu;Cho, Yoonho;Kim, Jinho
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.460-468
    • /
    • 2013
  • This study reviewed optimum dosage rate of coagulant and ability to remove dissolved organic carbon without sedimentation in conventional water purification plant. It was confirmed that floc formated by pre-treatment process was broken by impeller of booster pump. Optimum dosage rate of coagulant was 4 mg/L (as PACl 17%) for floc formation through blend, coagulation and after passing through the pump when turbidity of raw water was less than 10 NTU. And average removal rate of dissolved organic carbon was 43% at that time. Maximum removal rate of dissolved organic carbon was 48%, even though coagulation rate was increased gradually until 8 mg/L (as PACl 17%). So removal rate of dissolved organic carbon is not much improved even if dosage rage of coagulant increase. TMP of PVDF (polyvinylidene flouride) pressurized MF process without pre-treatment operated at 0.54 bar and TMP of PVDF pressurized MF process with pre-treatment operated at 0.41 bar.

A Study on the Coagulation of Wastewater Containing Fine Silica Particles with the Waste Slurry from Soda Ash Manufacturing Industries (소오다회 제조 공장의 폐슬러리를 이용한 미세 실리카 함유 폐수의 응집에 관한 연구)

  • Jun, Se Jin;Yim, Sung Sam
    • Applied Chemistry for Engineering
    • /
    • v.10 no.7
    • /
    • pp.1073-1078
    • /
    • 1999
  • The objectives of this study are to examine the applicability of waste slurry from soda ash manufacturing industries as a coagulant for the treatment of wastewater containing fine silica particles, and to reduce the cost of wastewater treatment containing silica. Acceptable water quality can be obtained with a little dosing of waste slurry by gelation before the coagulation process so it could be concluded that the waste slurry from soda ash can be used as a coagulant. Based on the results of experiments, the optimum pH of gelation for silica in wastewater was around five and the treatment process with the gelation of silica could reduce the chemical dosage and waste sludge after coagulation. Dewatering and settling characteristics of the floc after coagulation with the waste slurry are better than those of the floc after coagulation with the lime milk only.

  • PDF

Study on the Theoretical and Experimental Application of Filtration-Permeation Method (여과-투과 방법의 이론적, 실험적 응용에 대한 연구)

  • Song, Yun-Min;Yim, Sung-Sam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.161-167
    • /
    • 2008
  • Using an experimental method named filtration-permeation, the influence of sedimentation during filtration was studied for the suspensions composed of particles and that of flocs. The average specific cake resistances measured by filtration do not give accurate values because of the sedimentations during filtration, but the permeation data give quite accurate values. The prolonged permeation rates for the cake formed from particulate suspension do not change, but that rate from the floc filtration changes by the sweeping of flocculant. It is proposed that the cake compressibility can be measured with one set of filtration-permeation experiment by step increase of pressure during permeation period. The another experimental method which can shorten experimental time for floc filtration using filtrationpermeation is also proposed.

The Evaluation of Fouling Mechanism on Cross Flow Precoagulation-UF Process (십자형 응집-UF 막분리 공정 적용시 전처리 응집조건에 따른 막오염 메카니즘 규명)

  • Jung, Chul-Woo;Son, Hee-Jong
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.639-645
    • /
    • 2008
  • The objectives of this research are to (1) observe changes in particle size distribution due to formation of microflocs during coagulation process (2) identify the membrane fouling potential on cross flow system (3) investigate the mechanism of membrane fouling. The rate of flux decline for the hydrophobic membrane was significantly greater than for the hydrophilic membrane, regardless of pretreatment conditions. The pretreatment of the raw water significantly reduced the fouling of the UF membrane. Also, the rate of flux decline for the hydrophobic membrane was considerably greater than for the hydrophilic membrane. Applying coagulation process before membrane filtration showed not only reducing membrane fouling, but also improving the removal of dissolved organic materials that might otherwise not be removed by the membrane. That is, during the mixing period, substantial changes in particle size distribution occurred under rapid and slow mixing condition due to the simultaneous formation of microflocs and NOM precipitates. Therefore, combined pretreatment using coagulation not only improved dissolved organics removal efficiency but also flux recovery efficiency.

Purification of Cellulase Produced from Cellulomonas sp. YE-5 (Cellulomonas sp. YE-5가 생산하는 Cellulase의 정제)

  • 최동철;허남윤;오두환;유주현
    • Microbiology and Biotechnology Letters
    • /
    • v.18 no.4
    • /
    • pp.376-382
    • /
    • 1990
  • An extracellular cellulase producing bacterium YE-5 was isolated from soil, and identified as a Cellulomonas sp. by its taxonomical characteristics. The maximal activities of avicelase (0.35 units/ml), CMCase (3.18 units/ml), FPase (0.315 units/ml) and $\beta$-glucosidase (0.882 units/ml) were obtained when this strain was cultured for 48 hrs at $30^{\circ}C$ in a medium containing 0.8% (w/v) Solka floc, 0.06010 (wlv) urea, 0.1% (w/v) $K_2HP0_4$, 0.1% (w/v) $MgS0_4.7H2_0$, 0.2% (w/v) bacto peptone, 0.2% (w/v) yeast extract and pH 6.5. The cellulase was purified by ammonium sulfate fractionation, DEAE-Sepharose column chromatography and Sephadex 6-100 column chromatography from culture filtrate of Cellulomonus sp. YE-5. The molecular weights of purified avieelase, CMCase I, and CMCase II were estimated to be about 95,000 ~ 105,000, 46,000 ~ 47,000 and 120,000 ~ 125,000, respectively.

  • PDF

A Study on Removal of Dissolved Organic Matter and Phosphorus in Eutrophic Lake by Coagulation Process Using Powdered Activated Carbon (분말활성탄 응집침전 공정을 이용한 부영양화 호소수의 용존 유기물 및 인의 제거 연구)

  • Cho, Kyung Chul;Lee, Min Hee;Park, Jung Hwan;Jung, Jongtai
    • Journal of Wetlands Research
    • /
    • v.14 no.4
    • /
    • pp.629-635
    • /
    • 2012
  • This study was conducted to evaluate the removal behaviors of DOM(dissolved organic matter) and phosphorus in eutrophic lake water by coagulation process with PAC(powdered activated carbon). It was observed that the removal characteristic of soluble matter was different from that of dissolved one, and the removal of DOM was effected by both pH and coagulant dosage. It was founded that PAC could increase the removal efficiency by an adsorption of DOM in coagulation process. A formation of soluble and colloidal matters resulted in the degradation of phosphorus removal efficiency in a chemical precipitation process. The phosphorus removal efficiency could be enhanced by an absorption of colloidal matter and dissolved complex with PAC addition. In addition, the PAC addition caused the increase of floc density in coagulation process, that led to the rise of sedimentation rate, and resulted in a significant improvement of solid-liquid separation efficiency.

Study of Settling Properties of Cohesive Sediments (점착성 유사의 침강특성에 관한 연구)

  • Choi, In Ho;Kim, Jong Woo
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.303-310
    • /
    • 2017
  • This paper is to understand the settling properties of cohesive sediments under effects of ions in turbulent flow. The experiments were conducted using a miniature annular flume(mini flume) with a free water surface. Silica was used as sediment of experiment. The suspended concentrations were measured by using a CCD-Camera. Settling of silica($SiO_2$) was allowed to occur under various shear stresses in a concentration of 7g/L. At condition of pH 4.2 and high NaCl concentration, the floc size D of silica was larger than D at condition of pH6.8 with the bed shear stress increasing. The settling velocity $W_s$ of silica was higher at condition of 10g NaCl/L than $W_s$ at condition of pH4.2. Comparison of measured concentration-time curves and concentration-time curves calculated by this study showed similar tendency in flow under effects of ions.

Synthesis of Improved Polyaluminumchloride and Its Coagulation Properties (개선된 폴리염화알루미늄의 합성 및 응집 특성)

  • Choi, Yong-Wook
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.3
    • /
    • pp.273-282
    • /
    • 2004
  • The synthetic technology of improved polyaluminiumchloride (IPAC) similar to characteristics of PACS was established with minimum expense for modifying existing production line. The conditions for activating silicate was studied before the synthesis of IPAC, and the IPAC was synthesised with raw materials such as aluminumhydroxide and concentrated hydrochloric acid, followed by adding activated silicate and alginate. The specification of product, chemical structure, and coagulating properties were tested by using specification testing method, instrumental analytical method, and Jar tester, respectively. As a result, the product, IPAC, contained aluminium oxide content more than 17%, and no precipitation was shown at all while the IPAC solution was preserved, and the larger floc and faster coagulation were represented compared to existing PAC under the same conditions. It was suggested that these synthetic technology could be applied to the existing production line for producing PAC without approximately cost raising factor because of adding sulfuric acid-activated silicate instead of sodium sulfate.

Effect of the Al(III) Coagulant Basicity on Phosphorus Removal in Sewage Treated Water (하수처리수의 인 제거에 미치는 Al(III) 응집제 염기도의 영향)

  • Han, Seung-Woo;Lee, Chul-Hee;Lee, Jae-Kwan;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.149-154
    • /
    • 2012
  • According to the coagulation tests for PACs with various basicities, the PACB with lower basicity showed higher coagulation efficiencies of organics and phosphorus than the PAC with higher basicity. The PACB contained higher amount of monomeric Al (III) hydrolytic species comparing with PAC. In case of the coagulation for the sewage treated water, the coagulation efficiency by the charge neutralization and sweep floc formation was higher with PACB than with PAC. Accordingly, when $Al_2O_3$ concentration was similar in the coagulant, PACB showed higher removal efficiencies of turbidity, $COD_{Mn}$, TP, and $PO_4$-P comparing with PAC, especially in the lower range of coagulant dose.

Effect of Hydraulic Property and Mixing Intensity of Flocculation Basin on Flocculation Efficiency in Water Treatment Plant (정수장 플록형성지의 수리학적 특성과 교반강도가 플록형성 효율에 미치는 영향)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.230-235
    • /
    • 2005
  • The main purpose of the flocculation process is to make flocs bigger to be removed easily in the following processes. The flow pattern and mixing intensity have a great influence on flocculation. In this study, the flow pattern was examined by a hydraulic tracer-test, where 3 water treatment plants having $800,000m^3/d$, $44,000m^3/d$ and $40,000m^3/d$ were employed. Also, the settling test was conducted to find out the relationship between the mixing intensity and the settling ability of flocs. The hydraulic tracer-test was conducted for the various flocculation processes that have different structures of flocculation basins. In the result, the retention time distribution (RTD) curves for the flocculation processes were quite different. In case of the inappropriate structure of the flocculation basin, the flow is not even so that the floc does not grow enough. To find out the relationship between mixing intensity and settleability of flocs, G-values were calculated and the settling test was conducted for two flocculation basins which have the same conditions except the G-value. For the flocculation basin with uneven G-value, the floc settleability was revealed poor. On the other hand, the flocculation basin with even G-value, the settleability was better than the previous one. From these experimental results, it is confirmed that the flow pattern is closely related to the structure of the flocculation basin and the settleability is affected by mixing intensity. Therefore the flow pattern and the strength of the mixing intensity should be examined sufficiently to design and operate flocculation basin.