• Title/Summary/Keyword: flicker value

Search Result 18, Processing Time 0.019 seconds

Implementation of Supervisory System for Motion Information per Blocks (블록별 모션정보에 의한 감시시스템의 구현)

  • 김형균;오무송
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.1
    • /
    • pp.74-79
    • /
    • 2004
  • In this study, embodied supervisory system that apply motion detection technique to small web camera and detects watch picture. Motion detection technique that use pixel value of car image that use in existing need memory to store background image. Also, there is sensitive shortcoming at increase of execution time by data process of pixel unit and noise. Suggested technique that compare extracting motion information by block unit to do to have complexion that solve this shortcoming and is strong at noise. Because motion information by block compares block characteristic value of image without need frame memory, store characteristic cost by block of image. Also, can get effect that reduce influence about noise and is less sensitive to flicker etc.. of camera more than motion detection that use pixel value in process that find characteristic value by block unit.

The Direction of Power Quality Analysis Technology (전기품질 진단기술의 방향)

  • Kang, Chang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2005.05b
    • /
    • pp.16-18
    • /
    • 2005
  • Becoming more and more diversified and complicated, power quality management has focused on the electricity-failure duration(including the numbers), the appropriate rate of voltage(average voltage during 30 minutes), the stability rate of frequency etc. as a basic goal value. And recently the focus is moving into the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, instantaneous electricity failure, flicker etc. by the development of electricity & electronics and communication equipments, which had not been so big problems before. This paper will address the flow of analysis technology and forecast the desirable direction of power quality analysis technology in the future.

  • PDF

Detection of Anormalies on the Power Line using the Instantaneous Frequencies (순간주파수를 이용한 전력선 신호의 이상현상검출)

  • Iem, Byeong-Gwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.544-548
    • /
    • 2006
  • The instantaneous frequency gives a frequency value at a time instance. Thus, it is natural to use the instantaneous frequency for detecting disturbances of voltage signal in power line. Various instantaneous frequency estimators are introduced. By applying to different types of disturbed signals, we show the estimators' ability to classify flickers. Also, the computational costs are compared between different instantaneous frequency estimators. The Prony's method (PRONY) and the modified covariance method (MCOV) need relatively smaller amount of calculation than the Teaser-Kaiser energy operator based estimator (DESA II). For an AM-FM modulated signal, the tracking performance of different instantaneous frequency estimators is also compared. Through simulation, it is shown that MCOV produces less variant frequency estimation values than DESA II and PRONY method.

A Study on Driving Characteristics of the Elderly Driver using a Driving Simulator (운전모의장치를 이용한 고령자의 운전특성 연구)

  • Lee, Won-Young
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.103-111
    • /
    • 2006
  • The purpose of this study was to analyse the relationships between cognitive abilities and driving characteristics of elderly drivers. Driving characteristics of elderly and younger drivers who were driving a fixed base driving simulator vehicle were examined. Participants consisted of 12 drivers over age 65 (the 'older' group) and 12 drivers between the ages of 25 and 55 (the "younger" group). As indices of cognitive ability, critical flicker fusion frequency (CFF) tests and cognitive reaction tests were given before the driving task. CFF was also tested after the simulated driving task for both groups. Cognitive reaction tests, which were composed of speed estimation tests, multiple choice reaction tests and obstacle avoidance tests, were developed by the Korean Road Traffic Safety Authority in 2003. CFF values between the two groups exhibited significant differences both before and after the task, with a p-value less than 0.01 and a t-value of -3.01 before the test and a p-value less than 0.031 and a t-value of -2.35 after the test. Older drivers' CFF values were lower than those of the younger. However, there was no difference in older or younger driver CFF values before and after the task within the same group. Except for the multiple choice reaction test, there was no difference in cognitive reaction test results between the two groups. The elderly drivers made more errors though they did not differ from the younger drivers in reaction times. At the simulated driving task the reaction time of the elderly driver was longer than that of the younger; however, the driving speed of the elderly was lower and the number of collisions greater. There was a positive correlation (r=.496) between the number of errors in the multiple choice reaction test and the number of collisions in the driving task. Therefore, it was identified that critical attributes contributing to automobile crashes involving elderly drivers included cognitive difficulty in judging and responding to complex situations.

Comparison of Some Physiological Indices during Graded Load with Paced & Self-Paced Respiration (보조와 외부보조 호흡시 부하에 대한 생리적 지표들의 비교연구)

  • Kim, Jeong-Seok;Lee, Jong-Seong;No, Jae-Ho
    • Journal of the Ergonomics Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.17-24
    • /
    • 1985
  • To compare heart rate, $O_2$ uptake, $Vo_2$ ($O_2$ consumption), blood pressure (systolic, diastolic), reaction time, stability, flicker fusion value during 4 load levels with Rs (self-paced respiration) and Rp (paced respiration), 4 subjects participated in this experiment 1 hour/day, 6 days/week for 9 weeks. The cycle of Rp is 6 sec. (inspiration: 3 sec. & expiration: 3 sec.) Implications of the results are discussed in terms of the change in the physiological responses and human performance by the respiratory pattern. The results are as follows, 1. The changing magnitude of heart rate with Rp was larger than with Rs and the variance during load level 4 was significant. 2. The $Vo_2$ with Rp was smaller than with Rs and maximal $O_2$ uptake given load levels with Rp occurred and for two subjects, it significantly moved from low load level to high load level. 3. The changing magnitude of blood pressure was not consistent but the systolic pressure with Rp was smaller at rest than with Rs. 4. The score of reaction time test and stability test with Rp was better than with Rs.

  • PDF

360° Projection Image Analysis Method for the Calibration (보정을 위한 고해상도 360° 프로젝션 영상 분석 방법)

  • Han, Jung-Soo;Kim, Gui-Jung
    • Journal of Digital Convergence
    • /
    • v.13 no.12
    • /
    • pp.203-208
    • /
    • 2015
  • Image degradation will occur depending on hardware characteristics according to the lapse of time between beam projectors when multivision system is installed in the Theme park/Exhibition/Science Museum. In this paper, we have researched the 10-bit High-depth and high-resolution $360^{\circ}$ projection image analysis technique to solve the problems of quality and the maintenance of the theater. The goal is to minimize the economic losses and the development of special theater calibration system that can efficiently support a quality of an image. We proposed the method of image analysis technology, and explained the detailed functions and evaluation methods for image analysis technique. Evaluation method included the performance items, and proposed reasonable value to the experimental method and the goal value.

Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations (전동력설비의 운전에 의해 발생되는 자계의 측정과 해석)

  • 이복희;길경석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.58-67
    • /
    • 1995
  • The paper describes the variation of magnetic fields caused by the operation of induction motors. The measuring system consists of the self-integrating magnetic field sensor, amplifier, and active integrator. From the calibration experiments, the frequency bandwidth of the magnetic field measuring system ranges from 20[Hz] to 300[kHz] and sensitivity is 0.234(mV/$\mu\textrm{T}$]. The magnetic fields generated under steady state and starting operations of duction motor are recorded by the proposed measuring system, and the fast Fourier transformation(FFT) of the measured data is performed to analyze the harmonic components. A single pulsed magnetic field is strongly caused by direct starting the induction motor, and its peak value is greater than 5 times as compared with the steady state value. The long transient duration and high intensity originates from the large inductance and dynamic characteristic of the induction motor, During the steady state operation of induction motor, subharmonics of magnetic field components, which depend on the pole number of induction motor, are observed. The lower order power-line harmonics can be inferred from the voltage flicker and current ripple which are derived from the torque fluctuation of induction motor. In the case of the induction motor drived by inverter, the harmonics of magnetic field are much more than those caused by direct starting method and are found generally to increase with decreasing the driving frequency.

  • PDF

Dynamic Model Based Ratio Calculation of Equivalent Reactance and Resistance of the Bulk Power Systems (동적모델을 이용한 대규모 전력계통의 등가 리액턴스와 저항 비율(X/R) 계산)

  • Kook, Kyung-Soo;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2739-2746
    • /
    • 2011
  • This paper proposes the method for more effectively calculating X/R which is the ratio of equivalent reactance(X) and resistance(R) of the bulk power system and analyses the characteristic of X/R values by applying the proposed method to the real bulk power systems. X/R is used to determine the rating of the relay in the bulk power systems and its value has been accepted to be big enough to ignore the equivalent resistance of the bulk power systems. However, X/R is calculated as a big number when only the upper transformer and transmission line are considered. The correct approach to calculating X/R needs to consider all the parameters including generators, transformers, lines and loads. This paper calculates X/R of the bulk power systems using dynamic models which have been used to analyse the power system stability. The effectiveness of the proposed method is verified by applying it to the test system and X/R values of the real bulk power systems are analyzed. In addition, the dependence of X/R on the closeness of its calculating locations to the generator is verified by using the marginal loss factor which has been used in the electricity market.