• 제목/요약/키워드: flexural test

검색결과 1,908건 처리시간 0.032초

GFRP 표면매립공법으로 보강된 RC보의 고온노출 후 휨 성능 (Flexural Performance of RC Beams Strengthened with NSM-GFRP Exposed to High Temperature)

  • 김희승;이혜학;최경규
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.35-42
    • /
    • 2018
  • This study evaluated the fire resisting capacity and post-fire serviceability of the concrete beams retrofitted by near surface mounted method(NSM) using GFRP plates. Main parameters in the test are grout materials and fire exposure. For the test, two types of grout materials between concrete substrate and GFRP plate were used; flame resisting epoxy and filling mortar. Four RC beam specimens were made and two of them were exposed to fire according to real scale fire curve proposed KS F 2257. After the fire exposure test, flexural test were performed to investigate the flexural performance of concrete beams including strength and deformation. From the test results, it was found that the beam retrofitted by NSM-GFRP presented higher flexural strength than that of the beam without retrofit, which indicates NSM-GFRP retrofit technologies is effective to maintain flexural strength even after fire exposure. In addition, the specimens grouted by epoxy showed good performance in strength but bad performance in ductility.

합성섬유로 보강된 시멘트-점토-모래 혼합토의 휨성능 평가에 관한 연구 (Flexural Performance of Cement Treated Clay-Sand Mixtures Reinforced with Synthetic Fibers)

  • 정두회;조백순;이용운
    • 한국지반신소재학회논문집
    • /
    • 제16권1호
    • /
    • pp.19-29
    • /
    • 2017
  • 시멘트-점토-모래 혼합토의 휨성능 개선을 위하여 합성섬유를 이용해서 보강한 섬유보강토에 대한 휨성능 시험을 실시하였다. 시멘트, 모래, 그리고 섬유가 혼합토의 휨성능에 미치는 영향을 평가하기 위하여 시멘트량(15%, 20%, 25%), 모래함량(0%, 10%, 20%), 섬유의 종류(PP, PVA)와 길이(6mm, 12mm), 섬유혼입량(0.5%, 1.0%, 1.5%)을 조합하여 시험편을 제작하였다. 본 연구의 결과 시멘트 개량토를 섬유를 이용해서 보강하면 휨강도와 휨인성이 개선되는 효과를 확인할 수 있었다. 휨성능 시험 결과에 대한 다중선형회귀분석 결과 시멘트량과 모래함량은 휨강도에 영향을 미치는 주요 인자인 것으로 나타났고, 반면에 섬유혼입량은 균열발생 후의 거동에 영향을 미치는 주요 인자인 것으로 나타났다.

Flexural properties of a light-cure and a self-cure denture base materials compared to conventional alternatives

  • Mumcu, Emre;Cilingir, Altug;Gencel, Burc;Sulun, Tonguc
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권3호
    • /
    • pp.136-139
    • /
    • 2011
  • PURPOSE. A new light curing urethane dimethacrylate and a cold curing resin with simpler and faster laboratory procedures may have even improved flexural properties. This study investigated the 3-point flexural strengths and flexural moduli of two alternate base materials. MATERIALS AND METHODS. A cold curing resin (Weropress) and a light curing urethane dimethacrylate base material (Eclipse). Along with Eclipse and Weropress, a high impact resin (Lucitone199) and three conventional base materials (QC 20, Meliodent and Paladent 20) were tested. A 3-point bending test was used to determine the flexural strengths and flexural moduli. The mean displacement, maximum load, flexural modulus and flexural strength values and standard deviations for each group were analyzed by means of one-way analysis of variance (ANOVA) (with mean difference significant at the 0.05 level). Post hoc analyses (Scheffe test) were carried out to determine the differences between the groups at a confidence level of 95%. RESULTS. Flexural strength, displacement and force maximum load values of Eclipse were significantly different from other base materials. Displacement values of QC 20 were significantly different from Lucitone 199 and Weropress. CONCLUSION. The flexural properties and simpler processing technique of Eclipse system presents an advantageous alternative to conventional base resins and Weropress offers another simple laboratory technique.

THE EFFECT OF SURFACE FINISHES ON FLEXURAL STRENGTH, FRACTURE TOUGHNESS OF FELDSPATHIC DENTAL PORCELAIN

  • Chang, Il-Sung;Lee, Sun-Hyung;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.293-305
    • /
    • 2005
  • Statement of problems. Conventional feldspathic porcelain is used extensively as a restorative material and it is subjected to grinding and polishing during fabrication and delivery procedures. There is still considerable controversy concerning the best methods to achieve the strongest porcelain restorations after such adjustments. Purpose. The objective of this study was to investigate the effects of (1) overglazing, (2) selfglazing, and (3) fine polishing on the flexural strength and fracture toughness of feldspathic dental porcelain. Material and method. Ninety porcelain disks were prepared for flexural strength test and sixty porcelain disks were fabricated for fracture toughness test. Specimens were divided into three groups for each test as follows: 1) overglazed 2) self-glazed 3) polished. The flexural strength of feldspathic porcelains was determined by ring-on-ring biaxial flexural strength test. The fracture toughness values of three experimental groups were obtained by indentation fracture toughness test. Results. The flexural strength of overglazed group was significantly higher than that of selfglazed and polished group (P<0.05), while the difference between self-glazed and polished group was not significant (P>0.05). The fracture toughness values of overglazed and polished group were significantly higher than that of self-glazed group (P<0.05), while the difference between overglazed and polished group was not significant (P>0.05). Conclusions. This results supported the use of polishing as an alternative to glazing metal ceramic restorations, as it was not detrimental in flexural strength and fracture toughness. But, under the conditions of this study, overglazing was the ideal surface finishing method of feldspathic dental porcelain.

Flexural Strength Evaluation of RC Members Laminated by Carbon Fiber Sheet

  • Park, Hae-Geun
    • KCI Concrete Journal
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 2002
  • This paper reports the experimental and analytical investigations for evaluating the flexural strength of a RC slab strengthened with carbon fiber sheet (CFS). The evaluation of the ultimate flexural strength of a slab is tried under the assumption that the failure occurs when the shear stress mobilized at the interface between the concrete bottom and the glued CFS reaches its bond strength. The shear stress is evaluated theoretically and the bond strength is obtained by a laboratory test. The ultimate flexural strength is obtained by flexural static test of the slab specimen, which corresponds to the part of a real slab. From the results, the new approach based on the bond strength between concrete and CFS looks feasible to evaluate the flexural strength of the CFS and RC composite slab.

  • PDF

폴리올레핀계 구조용 합성섬유보강 콘크리트의 휨성능 및 화재 저항성 (Flexural Performance and Fire Resistance of Polyolefin Based Structural Synthetic Fiber Reinforced Concrete)

  • 박찬기;원종필
    • 한국농공학회논문집
    • /
    • 제50권1호
    • /
    • pp.49-57
    • /
    • 2008
  • This study evaluated the flexural properties and fire resistance of polyolefm based structural synthetic fiber reinforced concrete. The effects of differing fiber length, dimension and fiber volume fraction were studied. Flexural and fire resistance test were conducted in accordance with the JCI SF-4 and RABT time heating temperature curve, respectively. The Flexural test results indicated that the polyolefln based structural fiber reinforcement showed an ability to increase the flexural toughness and good fire resistance significantly(as compared to steel fiber reinforcement).

하이브리드 강섬유 보강 초고강도 콘크리트 휨파괴형 부재의 강도 및 연성 평가에 관한 연구 (Evaluation of Flexural Strength and Ductility of Hybrid Fiber Reinforced UHSC Flexural Members)

  • 여옥경;배백일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권6호
    • /
    • pp.61-69
    • /
    • 2019
  • 본 연구에서는 단일강섬유와 하이브리드강섬유로 보강된 UHPC의 휨강도 및 연성을 평가하기 위해 세 개의 휨파괴형 보에 대한 4점 가력 실험을 수행하였다. 실험 결과 단일섬유로 보강된 UHPC보다 하이브리드 섬유로 보강된 UHPC가 강도 및 연성 모든 측면에서 더 우수한 구조성능을 보유한 것으로 나타났다. 설계시의 안전성에 대해 평가하기 위하여, K-UHPC 구조설계지침에서 제공하는 방법에 따라 실험체의 강도와 연성을 평가해본 결과 현재의 재료모델은 강도에 대해서는 보수적으로 평가할 수 있으나 연성에 대해서는 과대평가하는 것으로 나타났다.

FRP복합체로 보강된 실물모형 RC보의 보강재 강성에 따른 휨 보강성능 (Flexural Performance of Full-scale RC Beams Strengthened with Different Amount of FRP Composite)

  • 최기선;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.125-128
    • /
    • 2006
  • Many research have been carried out concerned with the flexural performance of FRP composite in a various ways. Most of them, however, have used a small-scale specimen, so haven't been fully verified by full-scale model test. In this study, a full-scale RC beam model test for flexural strengthening with CFRP composites has been performed in order to verify test results obtained through a series of small-scale model test with respect to FRP stiffness affecting strengthening performance in the previous studies. A total of 4 specimens have been manufactured including control beam. The specimens strengthened with CFRP composites consist of 3 different CFRP stiffness with 2 types of CFRP composite. Consequently, the purpose of this study is to estimate influence of the size effect of specimens and FRP stiffness on the flexural performance. As a result, the effective strain of FRP composite is inversely proportional to FRP stiffness and ensures the same performance with small-scale model test.

  • PDF

구조용 데크 플레이트 연속 슬래브의 휨거동에 관한 실험적 연구 (An Experimental Study on the Flexural Behavior of Structural Deck Plate Continuous Slabs)

  • 김영호;박영석;박성우;고영우;양근혁;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.202-205
    • /
    • 2003
  • The purpose of this experimental study is to understand the flexural Behavior of structural deck plate continuous slabs (power deck plate slabs). The main variables considered in this test are thickness of the slab and the deck plate. Five specimens that have length of 600cm and width of 60cm were manufactured. Test results indicated that the ultimate flexural strength of power deck plate slabs was conservative compared to ACI flexural provisions. But, suitable arrangement of bar of top reinforcement is needed for crack control.

  • PDF

재생 폐 PET섬유보강 콘크리트의 부착 및 휨 특성 (Bond and Flexural Properties of Fiber Reinforced Concrete with Recycled Poly Ethylene Terephthalate Waste)

  • 원종필;박찬기;최민정
    • 대한토목학회논문집
    • /
    • 제28권3A호
    • /
    • pp.401-406
    • /
    • 2008
  • 본 연구에서는 폐 PET병을 사용하여 구조적으로 효과가 있는 재생 PET섬유를 생산하였고 세 가지 형상의 재생 PET섬유와 시멘트 매트릭스와의 부착성능을 평가하였다. 또한 세 가지 형상의 재생 PET섬유로 보강된 콘크리트의 휨성능 시험을 실시하였다. 시험결과 재생 PET섬유는 우수한 부착성능의 증가를 보여주었다. 휨시험 결과 재생 PET섬유는 콘크리트의 휨인성을 증가시킨다는 것을 증명하였다. 부착 및 휨시험 결과를 기본으로 요철형 재생 PET섬유의 부착 및 휨성능이 다른 형상의 섬유와 비교하여 가장 우수하였다.