• Title/Summary/Keyword: flexural study

Search Result 3,134, Processing Time 0.029 seconds

Effect of layer combinations with nanocomposite and low-shrinkage composite resins on their color and mechanical properties (나노복합레진과 저수축 복합레진의 복합 층으로 이룬 시편이 색과 물리적 성질에 미치는 영향)

  • Park, Wan-Ky;Choi, An-na;Son, Sung-Ae;Kwon, Yong Hoon;Kang, Eun-Sook;Park, Jeong-Kil
    • Korean Journal of Dental Materials
    • /
    • v.44 no.2
    • /
    • pp.129-139
    • /
    • 2017
  • This study investigated the colors and mechanical properties of layered dental composites. Four nanocomposite resins (Aelite LS, Grandio, Tetric EvoCeram, Filtek Z350XT) and a silorane-based composite resin (P90) were used for overlying and underlying materials, respectively, with different thickness combinations. Colors, translucency parameter (TP), flexural and compressive properties were evaluated. All tested specimens had different color coordinates, although all were of A3 shade. Color coordinates and TP values of layered specimens better matched those of the corresponding overlying product as the thickness of the overlying product was increased. High TP values were related with high $b^*$ value differences between specimens (p<0.05). Both flexural strength and modulus, compressive strength and modulus of layered specimens with different thickness combinations were mostly lower than those of the corresponding overlying products, respectively, in their non-layered state.

A Study for Shear Deterioration of Reinforced Concrete Beam-Column Joints Failing in Shear after Flexural Yielding of Adjacent Beams (보의 휨항복 후 접합부가 파괴하는 철근콘크리트 보-기둥 접합부의 전단내력 감소에 대한 해석적 연구)

  • Park, Jong-Wook;Yun, Seok-Gwang;Kim, Byoung-Il;Lee, Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.4
    • /
    • pp.399-406
    • /
    • 2012
  • Beam-column joints are generally recognized as the critical regions in the moment resisting reinforced concrete (RC) frames subjected to both lateral and vertical loads. As a result of severe lateral load such as seismic loading, the joint region is subjected to horizontal and vertical shear forces whose magnitudes are many times higher than in column and adjacent beam. Consequently, much larger bond and shear stresses are required to sustain these magnified forces. The critical deterioration of potential shear strength in the joint area should not occur until ductile capacity of adjacent beams reach the design demand. In this study, a method was provided to predict the deformability of reinforced concrete beam-column joints failing in shear after the plastic hinges developed at both ends of the adjacent beams. In order to verify the deformability estimated by the proposed method, an experimental study consisting of three joint specimens with varying tensile reinforcement ratios was carried out. The result between the observed and predicted behavior of the joints showed reasonably good agreement.

A Study on Effect of Anchor Plate on Concrete Breakout Capacity and Elasticity-Based Analysis Model of Anchor Plate (앵커플레이트가 콘크리트 파괴 강도에 미치는 영향 및 탄성기반 해석 모델에 대한 연구)

  • Shin, Ji-Uk;You, Young-Chan;Choi, Ki-Seon;Kim, Ho-Ryong;Kim, Jun-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.4
    • /
    • pp.381-388
    • /
    • 2013
  • This study presents that effect of anchor plate on concrete breakout strength was evaluated. The addition of the anchor plate is to improve the concrete breakout capacity for a single anchor system in a thin-walled concrete panel (Insulated concrete sandwich wall panel). In this study, an elasticity-based simplified model was developed and used to predict effect on the anchor plate. Flexural stresses of the plate with respect to the concrete breakout strength obtained from CCD (Capacity Concrete Design) approach were compared with the test results. Through the test results, while the concrete breakout strength was improved due to increment of the width and thickness of the anchor plate, improvement of the strength was steadily declined. In addition, the It was observed that the analytical and experimental flexure of the anchor plate was comparatively in good agreement using the simplified elastic analysis model.

Optimum Mix Proportions of In-fill Slurry for High Performance Steel Fiber Reinforced Cementitious Composite (초고성능 강섬유보강 시멘트 복합체의 충전슬러리 최적배합 도출)

  • Kim, Seung-Won;Park, Cheol-Woo;Kim, Seong-Wook;Cho, Hyun-Myung;Jeon, Sang-Pyo;Ju, Min-Kwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.3
    • /
    • pp.196-201
    • /
    • 2014
  • As political circumstances in oversea countries and Korea varies, the risk of vulnerability from unexpected extreme loading conditions, such as explosions or extreme impacts, also increased. In addition, construction companies in Korea recently have taken chances of overseas expansion to countries where their domestic situations are not in rest. Therefore, the resistance of construction materials for blast or impact loading become taking more consideration from engineering field. This study is a part of the research to develop a high performance fiber reinforced cementitious composite materials with high volume steel fibers and primary purpose of this study is to find an optimum mix proportions of in-fill slurry. In order to accomplish the tasks this study performed experimental investigations on the slurry for consistency, compressive strength, flowability, J-penetration, bleeding and rheology properties as well as mechanical properties, compressive and flexural strength, with respect to different mix proportions.

A Study on the Base Properties of Nickel Type-Antifungal Agent for Reinforced Concrete Hume Pipe Lining (철근콘크리트흄관 라이닝용 니켈계 방균제의 기초적 특성 연구)

  • Jo, Young-Kug
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.4
    • /
    • pp.41-47
    • /
    • 2010
  • It has been continuously noted that many sewage treatment concrete structures have deteriorated due to sulfur-oxidizing bacteria. There have been many reports on approaches to protecting concrete from this bacteria corrosion. The purpose of this study is to evaluate the inhibition of growth of a sulfur-oxidizing bacterium by a antifungal agent such as $NiSO_4{\cdot}6H_2O$, and the characteristics of polymer cement mortar using nickel type antifungal agent. First, we developed antifungal agents using metal nickel and $NiSO_4{\cdot}6H_2O$ to inhibit the growth of thiobacillus novellus, which is the sulfur-oxidizing bacteria in concrete. Then, ordinary cement mortar and polymer cement mortar using nickel type antifungal agent with various polymer-cement ratios, and antifungal agent content were prepared, and were tested for the antifungal adding effect, compressive and flexural strengths, expansion and leaching of nickel ion. From the test results, it was confirmed that the adding of an antifungal agent has an inhibition effect on the growth of sulfur-oxidizing bacteria at antifungal agent contents of 20 mM or more. In addition, the strengths and expansion of polymer cement mortars are not significantly changed by the addition of an antifungal agent. Therefore, the nickel-type antifungal agent developed in this study can be used to improve the durability of reinforced concrete hume pipe in the construction industry.

An Experimental Study on a Performance Evaluation of Internal Insulation of Buildings Over 20 Years Old (20년 이상 경과된 노후건축물의 단열재 성능평가에 관한 실험적 연구)

  • Kim, Hyun-Jin;Choi, Se-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.539-547
    • /
    • 2019
  • Recently, the international community signed a climate change agreement to prevent global warming. Yet currently, the fossil fuels have been widely used in to supply building energy for cooling and heating. The Green Building certification (G-SEED), an energy efficiency rating for new or existing buildings requires that buildings meet certain conditions. Insulation is used as a building material to reduce the energy supply to buildings and to improve the thermal insulation, and it accounts for more than 90% of the total heat resistance provided by the building surface components that meet the energy-saving design standards of new buildings. In this investigation, a performance evaluation study was conducted through an experimental study by directly extracting the foam polystyrene insulation on-site during the remodeling of a building that was in the range of 22~38 years old. Through tests, it was found that the thermal conductivity of the extrusion method insulation (XPS) was reduced by 48% and the compressive strength of XPS decreased by 36% compared to KS M 3808, which is the initial quality standard. For bead method insulation (EPS) with a thickness of 50mm, the thermal conductivity, the compressive strength, and flexural failure load were similar to the initial quality standard. Therefore, in the calculation of the primary energy requirement per unit area per year, the performance of bead method insulation can be estimated simply by considering the thickness of the insulation, while a correction factor that considers its performance deterioration should be applied when extrusion method insulation is used.

Classification Schemes of Precast Beam-Column Connections According to Contribution of Deformation Components (변형기여분에 따른 프리캐스트 보-기둥 접합부의 분류방안)

  • Choi, Hyun-Ki;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.545-553
    • /
    • 2014
  • This study suggested an integrated classification method for generalized characteristics of PC beam-column connection according to connection details. Quantifying the failure mode of PC-beam column connection and characteristics of corresponding details, this study suggested to use deformation contribution of each element of beam-column assemblage. According to the expected failure mode of beam-column connection assemblage, PC beam-column connection can be classified into 'equivalent monolithic system' and 'jointed system'. In this study, four test specimens were tested for verification of detailed classification method of PC beam-column connections. Test was carried out with typical beam-column connection test method. Load was applied at the top of test specimen and end of beams were restrained by hinge. In order to verify the deformation contribution of each test specimen, 34-LVDTs were mounted on test specimen. According to test results, deformation contribution of each test specimen have different characteristics. Deformation characteristics of joint and other components which are quantified by test results, equivalent monolithic system can be classified into two categories. Strong connection have extremely small deformation contribution of joint and much larger deformation contribution was shown in flexural behavior of beam. The other type of beam-column connection is ductile connection which allows the larger deformation in joint area compared with strong connection.

Improvement of Fatigue Model of Concrete Pavement Slabs Using Environmental Loading (환경하중을 이용하는 콘크리트 포장 슬래브 피로모형의 개선)

  • Park, Joo-Young;Lim, Jin-Sun;Kim, Sang-Ho;Jeong, Jin-Hoon
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.103-115
    • /
    • 2011
  • Concrete slab curls and warps due to the uneven distribution of temperature and moisture and as the result, internal stress develops within the slab. Therefore, environmental loads must be considered in addition to the traffic loads to predict the lifespan of the concrete pavement more accurately. The strength of the concrete slab is gradually decreases to a certain level at which fatigue cracking is generated by the repetitive traffic and environmental loadings. In this study, a new fatigue regression model was developed based on the results from previously performed studies. To verify the model, another laboratory flexural fatigue test program which was not used in the model development, was conducted and compared with the predictions of other existing models. Each fatigue model was applied to analysis logic of cumulative fatigue damage of concrete pavement developed in the study. The sensitivity of cumulative fatigue damage calculated by each model was analyzed for the design factors such as slab thickness, joint spacing, complex modulus of subgrade reaction and the load transfer at joints. As the result, the model developed in this study could reflect environmental loading more reasonably by improving other existing models which consider R, minimum/maximum stress ratio.

A Study on Static Behavior of 60 m span Half-Decked PSC Girder (Half-Deck을 포함한 60 m 경간 PS 콘크리트거더의 정적 거동 연구)

  • Kim, Tae Min;Park, Jong Heon;Kim, Moon Kyum;Lim, Yun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.65-73
    • /
    • 2012
  • In this study, we tested structural performance of Half-Decked PSC girder which was developed for applying to long span bridge. We operated 4 point bending test with 60 m span full scale girder designed as simple bridge with hinge-roller boundary condition. Actuators were set on the both sides of girder, 5.5 m away from the center, and 4 stages of cyclic loading was applied at rate of 1 kN/sec. Through stages 1 to 4, loading and unloading 1,000 kN, 1,200 kN, 1,500 kN, and 2,000 kN were repeated and displacement, strain of concrete and steel, crack of girder were checked. From these results, the strength of girder was assessed and resilience and ductility were observed after removing the load. Since initial flexural crack occurred in the vicinity of 1,400 kN, non-linearity of load-displacement curve appeared and definite residual strain was measured at that point. The test result showed that initial cracking load was over twice the DB-24 load which means the developed girder had sufficient strength. To verify the experimental results, we numerically analyze the test and confirmed that the data were similar with results from the test above. Half-Decked PSC type of 60 m-girder developed in this study showed its adequate structural capacity through static loading test, which proved that possibility of applying the girder to actual bridges practically.

Analytical Study on Structural Behavior of Surface Damaged Concrete Member by Calcium Leaching Degradation (칼슘 용출 열화에 의해 표면이 손상된 콘크리트 부재의 구조적 거동에 관한 해석적 연구)

  • Choi, Yoon-Suk;Jang, Yong-Hwan;Choi, So-Yeong;Kim, Il-Sun;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.22-32
    • /
    • 2014
  • Durability is one of the most important and attractive subjects in concrete research field because not only durability of concrete is reduced by various degradation factors but also its reduction adversely influences the structural performance and service life of concrete structure. For this reason, a considerable amount of papers associated with concrete durability have been published and those researches were mainly focused on the changes of intrinsic properties of concrete due to chemicophysical degradations. However, the relationship between durability of concrete and structural behavior of concrete member has not been well established yet. In this study, calcium leaching degradation, a cause of concrete strength reduction, was dealt with. The experiments of compressive and flexural behavior of degraded concrete member were performed to evaluate the characteristics of structural behavior according to degradation level. Finally, the results from the experiments were compared with those obtained from nonlinear FEM analysis. The results from this study clearly showed that leaching degradation leads to decrease in compressive strength and compressive behavior evolves from brittle to ductile failure pattern during the degradation process. Load capacity and flexible rigidity of the degraded RC member decreased when the degradation level increased, in compressive zone. Additionally, it was found that the values from nonlinear FEM analysis, CDP model in ABAQUS, coincided well with the experimental results.