• 제목/요약/키워드: flexural structural capacity

검색결과 426건 처리시간 0.029초

장경간 Spliced PSC 거더의 휨거동에 관한 실험적 연구 (An Experimental Study on the Flexural Behavior of Long Span Spliced PSC Girder)

  • 심종성;오홍섭;김민수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.519-524
    • /
    • 1999
  • A bulb-tee sectioned girder is proposed for long span bridge exceeding 40 meters. The proposed bulb-tee girder is developed by non-linear analysis process. This study investigates the structural behavior and efficiency of proposed bulb-tee sectioned girder using 1/2 scaled prototype beam specimen. Three specimens are tested under three point static loading system. The crack patterns, failure mode and ultimate load capacity of each specimen are reported in this paper and they are compared to each other.

  • PDF

폴리머시멘트 모르터를 이용한 RC 보의 휨 성능평가 (Evaluation of Flexural Performance of RC Beams Using Polymer Cementitous Mortar)

  • 양동석;고원준;박선규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.479-484
    • /
    • 2000
  • An experimental study to investigate the structural performance of reinforced concrete beams repaired by Polymer Cementitous Mortar in the tension zone is described. Preliminary trials with beams in which beams tensile reinforcing steel was exposed over 100%, 80% and 60% of their length have led to tests on $5\times25$cm beams over a 200cm span to examine the experimental parameter. Attention is concentrated upon overall bending capacity, deflection and crack development of repaired beams.

  • PDF

일반 건축물의 이형벽체 최적설계기법 적용사례 (Application of Building using Optimal Design Technique of Irregular Wall)

  • 한경수;방중석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.86-87
    • /
    • 2014
  • Recently, construction project has greatly increased the needs for cost savings due to excessive competition and economic recession. The purpose of this study is to introduce application of building using optimal design technique for improving constructability and economic efficiency of structural wall. As a results, design results of irregular wall show about 15% reduction of the longitudinal bar compared to single walls and ultimately improve constructability.

  • PDF

Effective Punching Shear and Moment Capacity of Flat Plate-Column Connection with Shear Reinforcements for Lateral Loading

  • Song, Jin-Kyu;Kim, Ju-Bum;Song, Ho-Bum;Song, Jeong-Won
    • International Journal of Concrete Structures and Materials
    • /
    • 제6권1호
    • /
    • pp.19-29
    • /
    • 2012
  • In this study, three isolated interior flat slab-column connections that include three types of shear reinforcement details; stirrup, shear stud and shear band were tested under reversed cyclic lateral loading to observe the capacity of slab-column connections. These reinforced joints are 2/3 scale miniatures designed to have identical punching capacities. These experiments showed that the flexural failure mode appears in most specimens while the maximum unbalanced moment and energy absorbing capacity increases effectively, with the exception of an unreinforced standard specimen. Finally, the results of the experiments, as wel l as those of experiments previously carried out by researchers, are applied to the eccentricity shear stress model presented in ACI 318-08. The failure mode is therefore defined in this study by considering the upper limits for punching shear and unbalanced moment. In addition, an intensity factor is proposed for effective widths of slabs that carry an unbalanced moment delivered by bending.

Investigation on structural behaviour of composite cold-formed steel and reinforced concrete flooring systems

  • Omar A., Shamayleh;Harry, Far
    • Steel and Composite Structures
    • /
    • 제45권6호
    • /
    • pp.895-905
    • /
    • 2022
  • Composite flooring systems consisting of cold-formed steel joists and reinforced concrete slabs offer an efficient, lightweight solution. However, utilisation of composite action to achieve enhanced strength and economical design has been limited. In this study, finite element modelling was utilised to create a three-dimensional model which was then validated against experimental results for a composite flooring system consisting of cold-formed steel joists, reinforced concrete slab and steel bolt shear connectors. This validated numerical model was then utilised to perform parametric studies on the performance of the structural system. The results from the parametric study demonstrate that increased thickness of the concrete slab and increased thickness of the cold formed steel beam resulted in higher moment capacity and stiffness of the composite flooring system. In addition, reducing the spacing of bolts and spacing of the cold formed steel beams both resulted in enhanced load capacity of the composite system. Increasing the concrete grade was also found to increase the moment capacity of the composite flooring system. Overall, the results show that an efficient, lightweight composite flooring system can be achieved and optimised by selecting suitable concrete slab thickness, cold formed beam thickness, bolt spacing, cold formed beam spacing and concrete grade.

교량 확폭시 RC 상판 접합부의 휨 피로파괴거동에 관한 실험적 연구 (An Experimental Study on the Flexural Fatigue Fracture Behavior of RC Slab of Widened Bridge)

  • 박영훈;전준창;조병완;장동일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.13-18
    • /
    • 1994
  • Most widened bridges have been constructed by the joining-construction method that makes new and existing bridge structurally single structure. However, joing-construction method has several problems in design and construction viewpoint. Therefore, this study is conducted in order to investigate structural behavior of widened RC slab and traffic-induced vibration of existing bridge during placing and curing of new concrete by the prototype flexural fatigue test. From the results of this study, it is shown that stress-concentration and slip occur between concrete and reinforcing rod at joint section but the reduction of load carrying capacity and of fatigue strength is negligible according to the traffic-induced vibration as well as the difference of construction method. A reasonable construction method for the bridge widening which takes into account the effects of the traffic-induced vibration and S-N curve for the widened bridge are also proposed.

  • PDF

Slenderness effects on the simulated response of longitudinal reinforcement in monotonic compression

  • Gil-Martin, Luisa Maria;Hernandez-Montes, Enrique;Aschheim, Mark;Pantazopoulou, Stavroula J.
    • Structural Engineering and Mechanics
    • /
    • 제23권4호
    • /
    • pp.369-386
    • /
    • 2006
  • The influence of reinforcement buckling on the flexural response of reinforced concrete members is studied. The stress-strain response of compression reinforcement is determined computationally using a large-strain finite element model for bars of varied diameter, length, and initial eccentricity, and a mathematical expression is fitted to the simulation results. This relationship is used to represent the response of bars in compression in a moment-curvature analysis of a reinforced concrete cross section. The compression bar may carry more or less force than a tension bar at a corresponding strain, depending on the relative influence of Poisson effects and bar slenderness. Several cross-section analyses indicate that, for the distances between stirrups prescribed in modern concrete codes, the influence of inelastic buckling of the longitudinal reinforcement on the monotonic moment capacity is very small and can be neglected in many circumstances.

고성능 강섬유보강 콘크리트가 적용된 I-단면 프리스트레스트 이중 콘크리트 보의 휨 거동 (Flexural Behavior of I-Section Prestressed Dual Concrete Beam Using High Performance Steel Fiber Reinforced Concrete)

  • 박대효;윤성환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.162-165
    • /
    • 2006
  • I-section prestressed concrete(I-PC) beam crack due to low tensile strength, may decrease rigidity and structural performance by excessive deflection. In an effort to this problem, in this research, I-section prestressed dual concrete(I-PDC) beam has been proposed, consisting of normal strength concrete in compression zone, and high performance steel fiber reinforced concrete(HPSFRC) with a bottom flange depth in tensile zone. Crack formation and its propagation are controlled by the HPSFRC in I-PDC beam. The initial cracking and service limit loads are increased along with the load carrying capacity and flexural stiffness.

  • PDF

Perfobond rib 전단연결재로 연결된 PSC-강 혼합구조 보의 휨 거동 실험 (An Experimental Study on Flexural Behaviors of Hybrid PSC-Steel Beam with Perfobond rib connectors)

  • 윤지현;원정훈;김상효;이찬구;김성재
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.101-102
    • /
    • 2009
  • 본 연구는 PSC 거더, Perfobond rib 전단연결재로 이루어진 연결부, 그리고 강 거더로 이루어진 혼합구조 보의 휨 거동에 대한 연구로써, 휨 실험을 통해 혼합구조 보의 휨 거동 특성과 파괴특성, 그리고 연결부 거동을 평가하였다.

  • PDF

Post-heating behavior of concrete beams reinforced with fiber reinforced polymer bars

  • Irshidat, Mohammad R.;Haddad, Rami H.;Almahmoud, Hanadi
    • Structural Engineering and Mechanics
    • /
    • 제53권6호
    • /
    • pp.1253-1269
    • /
    • 2015
  • The present paper investigates the post heating behavior of concrete beams reinforced with fiber reinforced polymer (FRP) bars, namely carbon fiber reinforced polymer (CFRP) bars and glass fiber reinforced polymer (GFRP) bars. Thirty rectangular concrete beams were prepared and cured for 28 days. Then, beams were either subjected (in duplicates) to elevated temperatures in the range (100 to $500^{\circ}C$) or left at room temperature before tested under four point loading for flexural response. Experimental results showed that beams, reinforced with CFRP and GFRP bars and subjected to temperatures below $300^{\circ}C$, showed better mechanical performance than that of corresponding ones with conventional reinforcing steel bars. The results also revealed that ultimate load capacity and stiffness pertaining to beams with FRP reinforcement decreased, yet their ultimate deflection and toughness increased with higher temperatures. All beams reinforced with FRP materials, except those post-heated to $500^{\circ}C$, failed by concrete crushing followed by tension failure of FRP bars.