• Title/Summary/Keyword: flexural force

Search Result 417, Processing Time 0.031 seconds

Effect of prestressing on the first flexural natural frequency of beams

  • Jaiswal, O.R.
    • Structural Engineering and Mechanics
    • /
    • v.28 no.5
    • /
    • pp.515-524
    • /
    • 2008
  • In this paper the effect of prestressing force on the first flexural natural frequency of beams is studied. Finite element technique is used to model the beam-tendon system, and the prestressing force is applied in the form of initial tension in the tendon. It is shown that the effect of prestressing force on the first natural frequency depends on bonded and unbonded nature of the tendon, and also on the eccentricity of tendon. For the beams with bonded tendon, the prestressing force does not have any appreciable effect on the first flexural natural frequency. However, for the beams with unbonded tendon, the first natural frequency significantly changes with the prestressing force and eccentricity of the tendon. If the eccentricity of tendon is small, then the first natural frequency decreases with the prestressing force and if the eccentricity is large, then the first flexural natural frequency increases with the prestressing force. Results of the present study clearly indicate that the first natural frequency can not be used as an easy indicator for detecting the loss of prestressing force, as has been attempted in some of the past studies.

Hysteretic characteristics of medium- to low-rise RC structures controlled by both shear and flexure evaluated by FEA and pseudo-dynamic testing

  • Ju-Seong Jung;Bok-Gi Lee;Kang-Seok Lee
    • Computers and Concrete
    • /
    • v.33 no.2
    • /
    • pp.217-240
    • /
    • 2024
  • The purpose of this study is to propose new hysteretic characteristics of medium- to low-rise RC structures controlled by both shear and flexure. Through previous study, the dual lateral force-resisting system composed of shear and flexural failure members has a new failure mechanism that cooperates to enhance the flexural capacity of the flexural failure member even after the failure of the shear member, and the existing theoretical equation significantly underestimates the ultimate strength. In this study, the residual lateral strength mechanism of the dual lateral force-resisting system was analyzed, and, as a result, an equation for estimating the residual flexural strength of each shear-failure member was proposed. The residual flexural strength of each shear-failure member was verified in comparison with the structural testing results obtained in previous study, and the proposed residual flexural strength equation for shear-failure members was tested for reliability using FEA, and its applicable range was also determined. In addition, restoring-force characteristics for evaluating the seismic performance of the dual lateral force-resisting system (nonlinear dynamic analysis), reflecting the proposed residual flexural strength equation, were proposed. Finally, the validity of the restoring-force characteristics of RC buildings equipped with the dual lateral force-resisting system proposed in the present study was verified by performing pseudo-dynamic testing and nonlinear dynamic analysis based on the proposed restoring-force characteristics. Based on this comparative analysis, the applicability of the proposed restoring-force characteristics was verified.

A new cable force identification method considering cable flexural rigidity

  • Wang, Long;Wu, Bo;Gao, Junyue;Shi, Kairong;Pan, Wenzhi;He, Zhuoyi;Ruan, Zhijian;Lin, Quanpan
    • Structural Engineering and Mechanics
    • /
    • v.68 no.2
    • /
    • pp.227-235
    • /
    • 2018
  • Cables are the main load-bearing members of prestressed structure and other tensegrity structures. Based on the static equilibrium principle, a new cable force identification method considering cable flexural rigidity is proposed. Its computational formula is derived and the strategy to solve its implicit formula is introduced as well. In order to improve the reliability and practicality of this method, the influence of the cable flexural rigidity on cable force identification accuracy is also investigated. Through cable force identification experiments, the relationships among certain parameters including jacking force, jacking displacement, initial cable force, and sectional area (flexural rigidity) are studied. The results show that the cable force calculated by the proposed method considering flexural rigidity is in good agreement with the finite element results and experimental results. The proposed method with high computational accuracy and resolution efficiency can avoid the influences of the boundary condition and the length of the cable on calculation accuracy and is proven to be conveniently applied to cable force identification in practice.

Seismic response simulations of bridges considering shear-flexural interaction of columns

  • Zhang, Jian;Xu, Shi-Yu
    • Structural Engineering and Mechanics
    • /
    • v.31 no.5
    • /
    • pp.545-566
    • /
    • 2009
  • Bridge columns are subjected to combined actions of axial force, shear force and bending moment during earthquakes, caused by spatially-complex earthquake motions, features of structural configurations and the interaction between input and response characteristics. Combined actions can have significant effects on the force and deformation capacity of RC columns, resulting in unexpected large deformations and extensive damage that in turn influences the performance of bridges as vital components of transportation systems. This paper evaluates the seismic response of three prototype reinforced concrete bridges using comprehensive numerical models that are capable of simulating the complex soil-structural interaction effects and nonlinear behavior of columns. An analytical approach that can capture the shear-flexural interacting behavior is developed to model the realistic nonlinear behavior of RC columns, including the pinching behavior, strength deterioration and stiffness softening due to combined actions of shear force, axial force and bending moment. Seismic response analyses were conducted on the prototype bridges under suites of ground motions. Response quantities of bridges (e.g., drift, acceleration, section force and section moment etc.) are compared and evaluated to identify the effects of vertical motion, structural characteristics and the shear-flexural interaction on seismic demand of bridges.

Flexural Pinching and Energy Dissipation Capacity (휨핀칭과 에너지 소산능력)

  • 박흥근;엄태성
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.275-285
    • /
    • 2003
  • Pinching is an important property of reinforced concrete member which characterizes its cyclic behavior. In the present study, numerical studies were performed to investigate the characteristics and mechanisms of pinching behavior and the energy dissipation capacity of flexure-dominated reinforced concrete members. By analyzing existing experimental studies and numerical results, it was found that energy dissipation capacity of a member is directly related to energy dissipated by re-bars rather than concrete that is a brittle material, and that it is not related to magnitude of axial compressive force applied to the member. Therefore, for a member with specific arrangement and amount of re-bars, the energy dissipation capacity remains uniform regardless of the flexural strength that is changed by the magnitude of axial force applied. Due to the uniformness of energy dissipation capacity pinching appears in axial compression member. The flexural pinching that is not related to shear force becomes conspicuous as the flexural strength increases relatively to the uniform energy dissipation capacity. Based on the findings, a practical method for estimating energy dissipation capacity and damping modification factor was developed and verified with existing experiments.

  • PDF

Evaluation of Flexural Performance of Reinforced Concrete Shear Walls According to Flexural Retrofit by Wall End Excavating (단부 파쇄형 휨 보강에 따른 철근콘크리트 전단벽 휨 성능 평가)

  • Cho, Ui-Jin;Kim, Su-Yong;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.4
    • /
    • pp.123-133
    • /
    • 2020
  • The purpose of this study is to analyze the method of retrofitting flexural strength and the flexural performance of retrofitted shear walls. There are various ways to reinforce the flexural strength of reinforced concrete shear wall structural systems that have already been built, in the case of that, the external force is increased, and the internal force is insufficient. However, there are various problems, such as excessive flexural stiffness after reinforcement and increasing the thickness and length of the wall. We have developed a retrofit method to solve these problems. The wall end is excavated to place the required vertical rebars, and concrete is poured after placing rebars. This is the same concept as creating wall end boundary elements later on. We also studied the anchorage method of reinforcement and the interaction method between the retrofitting end and the existing wall. The flexural test results for the reinforced concrete shear wall using the studied retrofit method can be predicted according to the sectional analysis and FEM analysis, and there are differences in the plastic hinge length, crack propagation, stiffness degradation and energy dissipation due to the bending depending on the vertical rebar ratio of wall end.

An Iterative Scheme for Resolving Unbalanced Forces Between Nonlinear Flexural Bending and Shear Springs in Lumped Plasticity Model (비선형 휨 및 전단 힌지 사이의 불평형력 해소를 위한 수렴계산 기법)

  • Kim, Yousok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.6
    • /
    • pp.227-235
    • /
    • 2022
  • For a member model in nonlinear structural analysis, a lumped plastic model that idealizes its flexural bending, shear, and axial behaviors by springs with the nonlinear hysteretic model is widely adopted because of its simplicity and transparency compared to the other rigorous finite element methods. On the other hand, a challenging task in its numerical solution is to satisfy the equilibrium condition between nonlinear flexural bending and shear springs connected in series. Since the local forces between flexural and shear springs are not balanced when one or both springs experience stiffness changes (e.g., cracking, yielding, and unloading), the additional unbalanced force due to overshooting or undershooting each spring force is also generated. This paper introduces an iterative scheme for numerical solutions satisfying the equilibrium conditions between flexural bending and shear springs. The effect of equilibrium iteration on analysis results is shown by comparing the results obtained from the proposed method to those from the conventional scheme, where the equilibrium condition is not perfectly satisfied.

Experimental Investigation for Flexural Stiffness of Paperboard-stacked Structure

  • Lee, Myung-Hoon;Park, Jong-Min
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.7 no.1
    • /
    • pp.9-15
    • /
    • 2001
  • Top-to-bottom compression strength of corrugated fiberboard boxes is partly dependent on the load-carrying ability of the central panel areas. The ability of these central areas to resist bending under load will increase the stacking strength of the box. The difference of box compression strengths, among boxes which are made with identical dimensions and fabricated with same components but different flute sizes, is primarily due to difference of the flexural stiffness of the box panels. Top-to-bottom compression strength of a box is accurately predicted by flexural stiffness measurements and the edge crush test of the combined boards. This study was carried out to analyze the flexural stiffness, maximum bending force and maximum deflection for various corrugated fiberboards by experimental investigation. There were significant differences between the machine direction (MD) and the cross-machine direction (CD) of corrugated fiberboards tested. It was about 50% in SW and DW, and $62%{\sim}74%$ in dual-medium corrugated fiberboards(e.g. DM, DMA and DMB), respectively. There were no significant differences of maximum deflection in machine direction among the tested fiberboards but, in cross direction, DM showed the highest value and followed by SW, DMA, DMB and DW in order. For the corrugated fiberboards tested, flexural stiffness in machine direction is about $29%{\sim}48%$ larger than cross direction, and difference of flexural stiffness between the two direction is the lowest in DMA and DMB.

  • PDF

Force factor of the stator used for ring type ultrasonic motor (링형 초음파 모터 고정자의 Force Factor)

  • Jeong, S.H.;Lee, J.S.;Yuk, H.S.;Chae, H.I.;Lim, K.J.;Bae, H.D.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1125-1129
    • /
    • 1993
  • A piezoelectric ring type plate, which vibrates in flexural vibration mode, is used for the stator of ultrasonic motor. To design the stator adequately, the force factor of the stator should be estimated in advance. The theoretically calculated force factors for the flexural vibration mode are compared with the measured ones to obtain good agreement. In order to study how to control the force factor, the relation between the shape of the stator and force factor is also considered.

  • PDF

An Cracking and Ultimate Behavior of Post-tensioned Prestressed High Strength Concrete Beams (포스트텐셔닝 공법의 프리트스레스트 고강도 빔부재의 균열 및 극한 거동)

  • Lee, Seong-Cheol;Choi, Young-Cheol;Oh, Byung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.323-326
    • /
    • 2005
  • Although many structures. with high strength concrete have been recently constructed, the flexural behavior of reinforced and prestressed concrete beams with high strength concrete is not exactly defined. This paper presents an experimental study on the flexural strength of the high strength concrete beams. Five large scale beams simply supported were tested and measured. Each beam was loaded by two symmetrical concentrated loads applied at 1.25m from the center of span. The concrete strength, the prestressed force and longitudinal tensile reinforcement ratio vary from beam to beam. From the experimental tests, the flexural strength from tests is larger than the nominal flexural strength of codes. Moreover, the initial crack-load is affected by the prestressed force and the crack width and spacing are controlled by the longitudinal tensile reinforcement ratio.

  • PDF