• Title/Summary/Keyword: flexor tendon rupture

Search Result 23, Processing Time 0.023 seconds

Trigger Toe in Soccer Player -A Case Report- (축구 선수에게서 발생한 방아쇠 족지 -1예 보고-)

  • Lee, Kyung-Tai;Young, Ki-Won;Kim, J-Young;Hwang, Seung-Keun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.114-115
    • /
    • 2004
  • A 18-year-old male soccer player had painful triggering and occasional locking of the great toe caused by entrapment of the flexor hallucis longus tendon within the flexor sheath posterior to the right medial malleolus. After other treatment modalities failed, the condition was relieved by a surgical procedure that removed the nodule on the flexor hallucis longus tendon and the ganglion under flexor retinaculum. Tendon rupture was not found, although there was tendinitis.

  • PDF

Minimal-incision tenorrhaphy in flexor tendon injury (굴곡건 손상에서 최소절개 건 봉합술)

  • Jang, Ju Yun;Oh, Sang Ah;Kang, Dong Hee;Lee, Chi Ho
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.516-518
    • /
    • 2009
  • Purpose: To retrieve the retracted flexor tendon, additional incision and wide dissection are conventionally required. We introduce minimal - incision tenorrhaphy using 1 cm - length incision and minimal dissection. Methods: Transverse incision about 1 cm - length is made over the level of retracted tendon. Nelaton's catheter is advanced into tendon sheath from distal primary laceration wound to emerge proximally through the incisional wound. Catheter is sutured to proximal tendon in end - to - end fashion. By gently pulling the catheter, retracted tendon is delivered to distal wound. Tenorrhaphy with core suture and epitendinous suture is then carried out. Results: This retrieving technique provides minimal incision, minimal dissection, minimal bleeding, minimal injury to tendon end, and shorter operation time with preservation of vincula tendinum and pulley system. Conclusion: In case of flexor tendon rupture with retraction, this operative method is believed to allow reliable and effective tenorrhaphy and excellent postoperative outcomes.

A Case of Trigger Finger Following Longitudinal Tear of Flexor Digitorum Superficialis after Repeated Closed Injury (반복적인 얕은손가락굽힘근힘줄 폐쇄성 손상 후 발생한 방아쇠 손가락 증례)

  • Choi, Hwan-Jun;Choi, Eui-Chul;Kim, Yong-Bae
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.304-308
    • /
    • 2010
  • Purpose: Many causes for triggering or locking of the fingers have been discussed in other literatures. The most common one is known stenosing tenosynovitis, which causes, a mismatch between the volume of the flexor tendon sheath and its contents. However, repeated trauma to the hand is uncommon cause of trigger finger. Therefore, we present a case of a rare condition of stenosing tenosynovitis which developed from a repeated relatively weak superficial flexor tendon injury. Methods: The patient was a 62-year-old woman who showed a painless, fixed and round mass on her right hand with no particular cause. Active and passive range of motion of the metacarpophalangeal joint of long finger was limited in flexion and extension. Ultrasonographic finding showed injured flexor digitorum superficialis tendon had fibrillar architecture with swelling between hyperechoic synovial membrane and hypoechoic surrounding area. Surgical exploration revealed that a bunched portion of the flexor digitorum superficialis and A1 pulley cause triggering during operation after adhesiolysis of scar tissue. Results: After releasing the A1 pulley, the range of motion of the metacarpophalangeal joint of long finger showed no limitation and histological examination of the subcutaneous tissue revealed fibrous fatty degeneration. In this case, releasing the A1 pulley with adhesiolysis of the subcutaneous scar tissue was successful and we obtained good functional outcome. Conclusion: We examined a patient in whom a repetitive impact forces to the palm caused longitudinal tear of the flexor tendon, leading to trigger finger. We experienced a rare case of stenosing tenosynovitis and trigger finger caused after close injury to flexor digitorum superficialis and its degenerative changes that caused mass like effect. To the best of authors' knowledge, our case of close injury to the flexor digitorum superficialis and unique morphologic change before rupture of tendon is rarely to be reported.

Neglected Achilles Tendon Rupture V-Y Tendinous Flap Reconstruction and Isokinetic Plantarflexion Torque Evaluation - Report of 3 Cases - (진구성 아킬레스 건 파열 V-Y 건판 재건술과 등속성 족저 굴곡력 분석 - 3례 보고 -)

  • Jung, Hong-Geun;Kim, Myung-Ho;Kim, Gun-Nam
    • Journal of Korean Foot and Ankle Society
    • /
    • v.4 no.2
    • /
    • pp.87-92
    • /
    • 2000
  • The tendinous ends of neglected achilles tendon rupture tend to retract and separate with atrophy due to gastrosoleus muscle contracture, leaving a wide gap occupied with fibroadipose scar tissue. It is almost impossible to perform simple end-to-end anastomosis after the intervening scar tissue being excised. Therefore many surgical procedures have been proposed to reconstruct the large gap. We treated three such cases by V-Y advancement flap and double Krackow suture technique, and their postoperative strength of triceps surae were evaluated with Cybex isokinetic strength testing. All patients returned to preinjury activities with satisfaction, but the ankle plantar flexor power showed about 20-30% deficit.

  • PDF

Flexor Tenorrhaphy Using Absorbable Suture Materials

  • Kang, Hyung Joo;Lee, Dong Chul;Kim, Jin Soo;Ki, Sae Hwi;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.397-403
    • /
    • 2012
  • Background Nonabsorbable sutures are favorable for repairing flexor tendons. However, absorbable sutures have performed favorably in an animal model. Methods Two-strand sutures using the interlocking modified Kessler method with polydioxanone absorbable sutures 4-0 were used to repair completely ruptured flexor tendons in 55 fingers from 41 consecutive patients. The medical records of average 42 follow up weeks were analyzed retrospectively. The data analyzed using the chi-squared test, and Fisher's exact test was used for postoperative complications. The results were compared with those of other studies. Results Among the index, middle, ring, and little fingers were injured in 9, 17, 16, and 13 fingers, respectively. The injury levels varied from zone 1 to 5. Of the 55 digits in our study, there were 26 (47%) isolated flexor digitorum profundus (FDP) injuries and 29 (53%) combined FDP and with flexor digitorum superficialis injuries. Pulley repair was also conducted. Concomitant injuries of blood vessels and nerves were found in 17 patients (23 fingers); nerve injuries occurred in 5 patients (10 fingers). Two patients had ruptures (3.6%), and one patient had two adhesions (3.6%). Using the original Strickland criteria, all the patients were assessed to be excellent or good. Also, fibrosis and long-term foreign body tissue reactions such as stitch granuloma were less likely occurred in our study. Compared to the Cullen's report that used nonabsorbable sutures, there was no significant difference in the rupture or adhesion rates. Conclusions Therefore, this study suggests that appropriate absorbable core sutures can be used safely for flexor tendon repairs.

Loop Suture Technique for Flexor Digitorum Profundus Tendon Repair in the Insertion Site (고리 봉합법을 이용한 심부 수지 굴건 종지부에서의 건봉합)

  • Lee, Kyu-Cheol;Lee, Dong-Chul;Kim, Jin-Soo;Ki, Sae-Hwi;Roh, Si-Young;Yang, Jae-Won
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.650-658
    • /
    • 2010
  • Purpose: In the case of repair for far distal parts of FDP (Flexor digitorum profundus) division, the method of either pull-out suture or fixation of tendon to the distal phalanx is preferred. In this paper, the results of a modified loop suture technique used for the complete division of FDP from both zone 1a and distal parts of zone 1b in Moiemen classification are presented. Methods: From July 2006 to July 2009, the modified loop suture technique was used for the 10 cases of FDP in complete division from zone 1a and distal parts of zone 1b, especially where insertion sites were less than 1 cm apart from a tendon of a stump. In a suture technique, a loop is applied to each distal and proximal parts of tendon respectively. Core suture of 2-strand and epitendinous suture are done with PDS 4-0. Out of 10 patients, the study was done on 6 patients who were available for the followup. The average age of the patients was 49.1 years (in the range from 26 to 67). 5 males and 1 female patients were involved in this study. There were 3 cases with zone 1a and distal parts of zone 1b. The average distance to the distal tendon end was 0.6 cm. There were 5 cases underwent microsurgical repair where both artery and nerve divided. One case of only tendon displacement was presented. The dorsal protective splint was kept for 5 weeks on average. The results of the following tests were measured: active & passive range of motion, grip strength test, key pinch and pulp pinch test. Results: The follow-up period on average was 11 months, in the range from 2 to 20 months. There was no case of re-rupture, but tenolysis was performed in 1 cases. In all 6 cases, the average active range of motion of distal interphalangeal joint was 50.8 degree. The grip strength (ipsilateral/contralateral) was measured as 88.7% and the pulp pinch test was 79.2% as those of contralateral side. Flexion contracture was presented in 2 cases (15 degree on average) and there was no quadrigia effect found. Conclusion: Despite short length of tendon from the insertion site in FDS rupture in zone 1a and distal parts of zone 1b, sufficient functional recovery could be expected with the tendon to tendon repair using the modified loop suture technique.

Minimally Invasive Surgery with Tenorrhaphy for Postoperative Hallux Varus Deformity Combined with Flexor Hallucis Longus Rupture after Hallux Valgus Correction: A Case Report (무지외반증 교정술 이후 합병된 무지내반증과 병발한 장무지굴건 파열에 대한 최소침습적 수술 및 건 봉합술: 증례 보고)

  • Nam, Bum Joon;Suh, Jin Soo;Choi, Jun Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.2
    • /
    • pp.102-106
    • /
    • 2020
  • A postoperative hallux varus deformity is a dreaded complication of hallux valgus surgery. Several surgical options have been introduced to overcome this problem. This paper reports an uncommon case of a 68-year-old female patient who presented with a postoperative hallux varus deformity combined with a rupture of the flexor hallucis longus (FHL) tendon. She was treated successfully by a minimally invasive correctional osteotomy with open tenorrhaphy. With experience in treating this complicated case, it was noted that FHL could be transected during the trans-articular adductor tenotomy. Hence, extra caution is needed when the degree of hallux valgus deformity is excessive. To the best of the author's knowledge, correctional valgization osteotomy for a postoperative hallux varus deformity in a minimally invasive manner has not been reported. This case report is expected to benefit surgeons and their patients with severe hallux valgus deformity.

Pull-in Suture Technique for the Disinsertion of the Phalangeal Tendon Distal Insertion (Pull-in 봉합술을 이용한 수지건 원위 부착부 파열의 치료)

  • Kim, Jae Won;Chung, Sung Mo
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.723-728
    • /
    • 2008
  • Purpose: The disinsertion of the phalangeal tendon distal insertion has difficulties in ordinary tenorrhaphy operation for the anatomical features, and still has controversy between non-surgical and surgical management. The purpose of this study is to select treatment for the injury of the phalangeal tendon distal insertion, as we've had a good results from operation treatment with Pull-in suture technique. Methods: We reviewed the hospital records of 12 patients treated with Pull-in suture technique with disinsertion of the phalangeal extensor or flexor tendon distal insertion from June 2006 to June 2007. Eight patients were involved with the tendon disinsertion without bone fracture, and 4 patients were involved with the fracture of the phalangeal tendon distal insertion site. After removal of the K-wire in week 6, active physical exercises were commenced immediately. The mean follow-up period was 12.4 months. Results: All the patients who had tendon disinsertion with bone fracture had IIB, by Wehbe and Schneider's classification 2, and we evaluated the results comparing the same finger of the other hand according to Crawford's evaluation criteria 5. The nine excellent and three good results were obtained and there were no limitation of motor for the patient who had operation for the rupture of flexor tendon as well. There were no particular complications during the follow-up period. Conclusion: The most important thing for the disinsertion of the phalangeal tendon distal insertion is to maintain an accurate and durable reduction state keeping the tension of tendon. At this point, after removal of the K-wire, the Pull-in suture technique allows accurate realignment of the tendon-bone unit without any specific instrumentation under the more stable state. The Pull-in suture technique seems to be a strong alternative for the treatment of disinsertion of the phalangeal tendon distal insertion, with successful treatment outcome(rapid functional recovery and high patient satisfaction).