• 제목/요약/키워드: flexor tendon

검색결과 111건 처리시간 0.026초

인체에 있어서 수동적 전기특성을 이용한 신호전달방향 계측법 개발 (A Development of the Method Measuring from Signal Propagation Direction using Passive Electrical Properties in Human Body)

  • 박형준;윤재현
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권8호
    • /
    • pp.378-385
    • /
    • 2006
  • In this study, a method measuring signal propagation direction in human body was developed by using passive electrical properties of the body. The measured method of the signal propagation direction is to apply basic characteristic of electricity to the human body; when a voltage is set to a conducted medium, according to the polarity of the conducted voltage, the voltage rising or drop is generated. And using this concept, it is able to estimate the direction of electrical signal on the human body. The passive electrical properties were measured and the direction of signal propagation was estimated on the followings; between the flexor carpi radialis, between arms, between legs, between an arm and a leg, between the cervical vertebra and the upper limb, between the sacral vertebra and the leg, between the cervical vertebra and the tendon of triceps brachii, and between the sacral vertebra and the calcaneal tendon. As the result of experiments, the passive electrical properties were increased from l[Hz] to 50[kHz] of the inputted frequencies and showed at saturating tendency after that. And also, the estimated signal propagation directions using the developed method in this study agreed with the expected directions exactly at each part of the human body.

Anatomical Study on Hand Gworeum Skin in Human

  • Park, Kyoung-Sik
    • 대한한의학회지
    • /
    • 제41권4호
    • /
    • pp.72-77
    • /
    • 2020
  • Objectives: This study was carried out to concrete the concept of Hand Gworeum Skin referred in Suwen of Huangdi Neijing. Methods: The Hand Gworeum Meridian was labeled with latex in the body surface of the cadaver, subsequently dissecting a superficial fascia and muscular layer in order to observe internal structures. Results: Skin histologically encompasses a common integument and a immediately below superficial fascia, this study established the skin boundary with adjacent structures such as relative muscle, tendon as its compass. The realm of the Hand Gworeum Skin is as follows: The skin close to the nipple on the 4th intercostal space, the interceps of biceps brachii muscle, the cubital surface at ulnad of bicipital aponeurosis, the anterior surface of the forearm, between flexor carpi radialis and palmaris longus(from wrist crease to 5chon above), the palm between the 3rd and 4th metacarpals on the cross part with the palm crease, the radiod from the middle finger nail(or the end of middle finger). The realm of the Hand Gworeum Skin is situated on between Hand Taeeum Skin and Hand Soeum Skin in front of arm. Conclusion: The realm of Hand Gworeum Skin from the anatomical viewpoint seems to be the skin area outside the superficial fascia or the muscle involved in the pathway of the Hand Gworeum Meridian vessel, Collateral Meridian vessel, and Meridian muscle, being considered adjacent vessels or nerves at the same time.

Pediatric Hand Trauma: An Analysis of 3,432 Pediatric Hand Trauma Cases Over 15 Years

  • Sung, Ki Pyo;Lee, Soo Hyang
    • Journal of Trauma and Injury
    • /
    • 제34권4호
    • /
    • pp.257-262
    • /
    • 2021
  • Purpose: Pediatric hand trauma is common and sometimes causes deformity or disability. The incidence and etiologies of hand trauma in children are different from those in adults. This study analyzed the characteristics of pediatric hand trauma cases and patients over a 15-year period. Methods: We conducted a retrospective medical record review of 3,432 children (2,265 boys, 1,167 girls, under 18 years of age) with hand injuries from January 2005 to December 2019. We evaluated the sex distribution and injury etiologies. Injuries were classified by type as burns, amputations, crushing injuries, lacerations, extensor and flexor tendon injuries, open and closed fractures, and nerve injuries. Results: Among the pediatric hand injury patients, males were predominant (1.94:1). Simple lacerations (58.4%) were the most common injury type, followed by fractures (22.8%). Lacerations and burns tended to be common in younger age groups, while tendon injuries, nerve injuries, and crushing injuries were more frequently encountered in older age groups. Conclusions: Hand trauma prevention strategies should be established considering the frequent trauma etiologies in specific age groups. An awareness of age-specific characteristics of pediatric hand trauma patients will be helpful to prevent hand trauma.

완관절과 수부 질환의 초음파 소견과 치료 (Ultrasound Findings and Treatment of Wrist and Hand Diseases)

  • 이종화
    • Clinical Pain
    • /
    • 제20권1호
    • /
    • pp.15-19
    • /
    • 2021
  • There are many wrist and hand diseases in which ultrasound can help in the diagnosis and treatment. Because many small structures are located, identifying anatomical locations and pathways is especially important. In De Quervain's syndrome, it is necessary to find tendon lesions located in the first compartment of the wrist. If injection therapy is required, administer the regimen accurately within the tendon sheath through ultrasound. In carpal tunnel syndrome, there are several methods to diagnose a disease by measuring cross-sectional area of the median nerve. Ultrasound has the advantage of administering injection therapy without damaging the nerve. Intersection syndrome can be diagnosed by observing swelling and hypoechoic appearances at the point where the tendons of the first compartment cross over the second compartment of the wrist. Ultrasound-guided injection is also safe and efficient. If there is a trigger finger lesion, the most representative findings is to observe a nodular hypoechoic thickening of the involved A1 pulley. When injection therapy is performed, it is effective to administer medication between pulley and flexor tendons as much as possible to reduce pressure on the attached structures.

레이저 변위계를 이용한 생체 연조직의 변형 측정법에 관한 연구 (A Study on the Measurement Methodology for Soft Tissue Deformation Using Laser Extensometer)

  • 최경주;홍정화;문무성;이진희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1085-1087
    • /
    • 2002
  • Deformation of soft tissue is known inhomogeneous and non-linear in general. In this study, we propose a measurement methodology of local/global strain during soft tissue elongation precisely using laser extensometer which has high accuracy, resolution and is possible to measure global/local strain. The mechanical tensile test are performed on tibialis cranialis, flexor hallucis longus, extensor digitorum longus of swine hindlimb. In order to measure target displacement, reflective marker is attached to detect elongation on specimen using surgical adhesive. The result of this study is to show that laser extensometer is valid to measure longitudinal elongation which is inhomogeneous and non-linear fur soft tissue.

  • PDF

Symptomatic Hallucal Interphalangeal Sesamoid Bones Successfully Treated with Ultrasound-guided Injection - A Case Report -

  • Shin, Hye Young;Park, Soo Young;Kim, Hye Young;Jung, Yoo Sun;An, Sangbum;Kang, Do Hyung
    • The Korean Journal of Pain
    • /
    • 제26권2호
    • /
    • pp.173-176
    • /
    • 2013
  • The hallucal interphalangeal sesamoid bone is usually asymptomatic, but it is not uncommon for it to be symptomatic in cases of undue pressure, overuse, or trauma. Even in symptomatic cases, however, patients often suffer for extended periods due to misdiagnosis, resulting in depression and anxiety that can steadily worsen to the extent that symptoms are sometimes mistaken for a somatoform disorder. Dynamic ultrasound-guided evaluations can be an effective means of detecting symptomatic sesamoid bones, and a simple injection of a small dose of local anesthetics mixed with steroids is an easily performed and effective treatment option in cases, for example, of tenosynovitis.

Anatomical Observation on Components Related to Foot Gworeum Meridian Muscle in Human

  • Park, Kyoung-Sik
    • 대한한의학회지
    • /
    • 제32권3호
    • /
    • pp.1-9
    • /
    • 2011
  • Objectives: This study was carried out to observe the foot gworeum meridian muscle from a viewpoint of human anatomy on the assumption that the meridian muscle system is basically matched to the meridian vessel system as a part of the meridian system, and further to support the accurate application of acupuncture in clinical practice. Methods: Meridian points corresponding to the foot gworeum meridian muscle at the body surface were labeled with latex, being based on Korean standard acupuncture point locations. In order to expose components related to the foot gworeum meridian muscle, the cadaver was then dissected, being respectively divided into superficial, middle, and deep layers while entering more deeply. Results: Anatomical components related to the foot gworeum meridian muscle in human are composed of muscles, fascia, ligament, nerves, etc. The anatomical components of the foot gworeum meridian muscle in cadaver are as follows: 1. Muscle: Dorsal pedis fascia, crural fascia, flexor digitorum (digit.) longus muscle (m.), soleus m., sartorius m., adductor longus m., and external abdominal oblique m. aponeurosis at the superficial layer, dorsal interosseous m. tendon (tend.), extensor (ext.) hallucis brevis m. tend., ext. hallucis longus m. tend., tibialis anterior m. tend., flexor digit. longus m., and internal abdominal oblique m. at the middle layer, and finally posterior tibialis m., gracilis m. tend., semitendinosus m. tend., semimembranosus m. tend., gastrocnemius m., adductor magnus m. tend., vastus medialis m., adductor brevis m., and intercostal m. at the deep layer. 2. Nerve: Dorsal digital branch (br.) of the deep peroneal nerve (n.), dorsal br. of the proper plantar digital n., medial br. of the deep peroneal n., saphenous n., infrapatellar br. of the saphenous n., cutaneous (cut.) br. of the obturator n., femoral br. of the genitofemoral n., anterior (ant.) cut. br. of the femoral n., ant. cut. br. of the iliohypogastric n., lateral cut. br. of the intercostal n. (T11), and lateral cut. br. of the intercostal n. (T6) at the superficial layer, saphenous n., ant. division of the obturator n., post. division of the obturator n., obturator n., ant. cut. br. of the intercostal n. (T11), and ant. cut. br. of the intercostal n. (T6) at the middle layer, and finally tibialis n. and articular br. of tibial n. at the deep layer. Conclusion: The meridian muscle system seemed to be closely matched to the meridian vessel system as a part of the meridian system. This study shows comparative differences from established studies on anatomical components related to the foot gworeum meridian muscle, and also from the methodical aspect of the analytic process. In addition, the human foot gworeum meridian muscle is composed of the proper muscles, and also may include the relevant nerves, but it is as questionable as ever, and we can guess that there are somewhat conceptual differences between terms (that is, nerves which control muscles in the foot gworeum meridian muscle and those which pass nearby) in human anatomy.

Patterns of wrist cutting: A retrospective analysis of 115 suicide attempts

  • Cho, Jakwang;Choi, Youngwoong
    • Archives of Plastic Surgery
    • /
    • 제47권3호
    • /
    • pp.250-255
    • /
    • 2020
  • Background Rosenthal et al. classified female, habitual, non-suicidal wrist cutters as a group and introduced the concept of wrist-cutting syndrome. We investigated the characteristics of wrist-cutting patients at our institution in comparison with results reported previously. Methods We conducted a retrospective study involving 115 patients who had cut their wrists and been examined at the emergency department of a single hospital in Seoul, Korea, between March 2014 and August 2018. Results There were more women (73 patients; 63.5%) than men (42 patients; 36.5%), and the women (mean age, 34.42 years) were significantly younger than the men (mean age, 50.07 years). The patients who had cut their wrists repeatedly were mainly women (22 of 26 patients; 84.6%); however, men caused more severe damage than women. Substance use before a suicide attempt did not significantly increase the severity of wrist cutting. Our institution planned and implemented a suicide prevention intervention program to improve the continuity of outpatient care. The number of patients who continued psychiatric treatment increased significantly after program completion. Conclusions We confirmed that most patients were young women who were not suicidal in the true sense because their wounds were not severe. Our study showed a protective role of the barrier tendons (flexor carpi radialis, palmaris longus, flexor carpi ulnaris), and we suggest careful repair of the barrier tendons to protect neurovascular structures against subsequent cutting events. We found that it was possible to improve the continuity of patient counseling by managing patients through a psychiatric treatment program.

연부조직 연골종에 의한 정중, 척골포착신경병증: 증례보고 (Entrapment Neuropathy of Median and Ulnar Nerve Due to Soft Tissue Chondroma: A Case Report)

  • 홍성택;안덕선
    • Archives of Plastic Surgery
    • /
    • 제37권6호
    • /
    • pp.815-818
    • /
    • 2010
  • Purpose: Soft tissue chondroma is a rare benign tumor, found mainly on the palm and sole and grows slowly. Typically, mature hyaline cartilage is the dominant pathological feature. There are reports that assert soft tissue chondromas to be a cause of median nerve entrapment syndrome. However, this is the first case report showing soft tissue chondroma to be a cause of simultaneous median and ulnar neuropathy. Methods: A 62 year-old woman presented with chief complaints of numbness and hypoesthesia of her right palm for 4 to 5 years, and a palpable mass on her right palm that had been increasing in size slowly for 3 years. Physical examination revealed a firm, mobile, non-tender and about $3{\times}3\;cm^2$ sized mass in the center of the right palm. Electromyography showed entrapment neuropathy of the median and ulnar nerve. Ultrasonography showed an approximately $5.7\;cm^2$ mass below the flexor tendon of ring finger. Upon surgical excision, a $3{\times}3\;cm^2$ mass attached to the flexor digitorum profundus of ring finger and redness and hypertrophy of both the median and ulnar nerve were discovered. Mass excision was performed gently and the specimen was referred for histopathologic study. Mass excision resulted in median and ulnar nerve release. Results: The pathology report confirmed the mass to be a soft tissue chondroma with mature hyaline cartilage. The patient exhibited post-operative improvement of her symptoms and did not show any complications. Conclusion: This is the first case report showing soft tissue chondroma to be a cause of simultaneous median and ulnar neuropathy.

A Cadaveric Study of Thread Cubital Tunnel Release with Newly Developed Threads

  • Kang, Minsuk;Nam, Yong Seok;Kim, In Jong;Park, Hae-Yeon;Ham, Jung Ryul;Kim, Jae Min
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권2호
    • /
    • pp.307-314
    • /
    • 2022
  • Objective : The percutaneous thread transection technique is a surgical dissecting method using a dissecting thread inserted through a needle under ultrasound guidance without skin incision. As the new dissecting threads were developed domestically, this cadaver study was conducted to compare the effectiveness and safety between the new threads (ultra V sswire and smartwire-01) and a pre-existing commercial dissecting thread (loop & shear) by demonstrating a modified looped thread cubital tunnel release. Methods : The percutaneous cubital tunnel release procedure was performed on 29 fresh cadaveric upper extremities. The pre-existing commercial thread was used in 5 upper extremities. The two newly developed threads were used in 24 upper extremities. Two practitioners performed the procedures separately. After the modified looped thread cubital release, anatomical and histological analyses were performed by a blinded anatomist. The presence of the dissected cubital tunnel and damaged adjacent soft tissue was assessed. Results : Out of the 29 cadaveric upper extremities, 27 specimens showed complete dissection of the Osborne ligament and the proximal fascia of the flexor carpi ulnaris muscle. One specimen was incompletely dissected in each of the ultra V sswire and smartwire-01 groups. There were no injuries of adjacent structures including the ulnar nerve, ulnar artery, medial antebrachial cutaneous nerve, or flexor tendon with either the commercial thread or the newly developed threads. The anatomical analysis revealed clear and sharp incisional margins of the cubital tunnel in the Smartwire-01 and loop & shear groups. All three kinds of threads maintained proper linear elasticity for easy handling during the procedure. The smartwire-01 provided higher visibility in ultrasound than the other threads. Conclusion : The newly developed threads were effective and safe for use in the thread cubital tunnel release procedure.