• Title/Summary/Keyword: flection

Search Result 33, Processing Time 0.019 seconds

The Kinematic Analysis of Back-Kick Motion in Taekwondo (태권도 숙련자와 미숙련자의 공격뒤차기 동작에 대한 운동학적 분석)

  • Lee, Dong-Jin;Park, Chan-Ho;Kim, Hun-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.43-51
    • /
    • 2006
  • The purpose of this study was to analyze kinematic variables during turing back kick motion of Taekwondo. The subjects of this study were the 4 skilled and 4 unskilled of male university player in respectively. The experiment of this study was used two 16mm high speed cameras and its speed 125 frames/s. Analysis of this data was three dimensional cinematography using KWON3D program package. The results were as following; 1. In the elapsed time, there was no significance difference statically between a skilled and unskilled group. But skilled group was more fast during the motion of I phase. And unskilled group was more fast during the motion of II phase so called force production section, which had an influence on Diechagi's velocity. 2. In the center of gravity of human body, the changing of it was $1.10{\pm}0.04m$, $1.12{\pm}0.03m$ of LFM(left foot movement) and $1.36{\pm}0.08m$, $1.39{\pm}0.09m$ of RKF(right knee flection), and $1.44{\pm}0.08m$, $1.42{\pm}0.09m$ of RFI(right foot impact). There was no significance difference statically between the two groups. 3. The velocity of heel on impact was 1.13m/s in the skilled group and 1.23m/s in the unskilled group, when each angle of knee was $110.4{\pm}10.9deg/s$, $114.8{\pm}28.4deg/s$. The maximum velocity of each performance was reached before the RKF, and the velocity and angle at impact along by two groups did not show any significant difference statically. 4. In the angular velocity of just RKF of lower leg, there was significance difference statically between the two groups(p<.05).

The Biomechanical Analysis of Various Vertical Jumps According to Gender of High School Students (고등학생의 성별에 따른 수직점프 유형별 운동역학적 분석)

  • Lee, Haeng-Seob;Ju, Myung-Duck
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.153-164
    • /
    • 2006
  • This thesis is focused on kinematical and kinematical analysis of each types(Type #1 : use both swing of arm and reaction of knee, Type #2 : Use only swing of arm, not reaction of knee, type #3 : Neither use of swing of arm nor reaction of knee) of vertical jumps according to gender of High School Students. The subjects of this study is High School Student's male and female, 5 each, for analyzation of actions 3D image analyzing and GRF machines were used. To identify the differences of analyzed variables, an independent T-test on gender, an One-way ANOVA on types were used. Summery of the results are stated below. first of all, female students showed differences on Hip Joint angle and Joint Velocity from male students on Kimentic Variable. So training on hip joint force of flection and extension of female students is needed. Both male and female students showed relatively bigger result of arm's Angular Momentum than thigh's Angular Momentum on Type #1. This is regarded of faster Joint Velocity of Arm. Bigger result of female students of arm's contribution on Type #1 than male students can be said as Female student's weaker hip joint's angular muscle force than male student's, so the dependency of arm is heavier than male students. In Kinetic variable, GRF showed bigger result on male students than female students. So female students need to enhance joint's torque to increase GRF than male students. On vertical Impulse, high numeric data of last two reaction of tiptoe of vertical GRF and antero-posterior GRF helped increasing impulse by extending action time of force.

Study on Lower Extremities Activities Pattern of ADL and Treadmill Gait According to Harness Body-Weight Support Percentages (일상생활 동작 및 하네스 체중지지율에 따른 트레드밀 보행 시 하지 패턴에 관한 연구)

  • Song, S.M.;Yu, C.H.;Kim, K.;Kim, J.J.;Song, W.K.;Hong, C.U.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.4
    • /
    • pp.319-329
    • /
    • 2015
  • The purpose of this paper is to analyze lower extremities pattern of daily activities and walking on the treadmill with passive body support system. The experiments will be used for basic research of developing active harness system. The experimental procedure has been validated on 5 healthy male subjects and we measured foot pressure and 8 section of lower limb muscles activities. The EMG results of ADL indicate that there have specific muscle activity patterns followed by each activities. The vastus lateralis muscle activities were highly seems on the activities that requires flection and extension of knee joint. The foot pressure value of stair descent activity was the highest due to the fact that it is come down to the direction of gravity. The results with the passive body weight support percentages show that the EMG and foot pressure values were declined according to increasement of the body weight support percentages. Therefore the body weight support system could apply gait rehabilitation system for various patients by changing the percentages of the body weight support.

  • PDF

Evaluation of muscle fatigue during isometric exercise depending on concentric contraction and eccentric contraction (등척성 운동 시 근육의 단축성 운동과 신장성 운동에 따른 근피로도 평가)

  • Lee, Y.H.;Jung, H.D.;Choi, H.H.;Mun, C.S.;Mun, C.W.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.1
    • /
    • pp.59-65
    • /
    • 2012
  • In this study, muscle fatigue of biceps and triceps during isometric exercise depending on concentric contraction and eccentric contraction was evaluated using EMG. 12 healthy male volunteers was performed concentric exercise and eccentric exercise by maximum flection and extension of elbow joint. Integrated EMG (IEMG) in time domain and mean power frequency (MNF) in frequency domain were calculated. MNF of the biceps and triceps was decreased, whereas IEMG was increased during concentric contraction and eccentric contraction. But muscle fatigue index appeared higher at region of stretched muscle length. in this result, muscle fatigue occurs at both biceps and triceps muscle during concentric and eccentric exercise, and muscle fatigue was affected by muscle contraction and extension.

  • PDF

Kinematic Analyses of Women's Pole Vault in IAAF World Championships, Daegu 2011 (2011 대구 세계육상선수권대회 여자 장대높이뛰기경기 기술의 운동학적 분석)

  • Choi, Kyoo-Jeong;Yi, Kyung-Ok;Kim, Nam-Hee;Kang, Ji-Eun;Kim, Hye-Lim
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.561-571
    • /
    • 2011
  • The purpose of this study was to perform the kinematic analyses of the women's pole vault skills in IAAF World Championships Daegu 2011. Subjects were the 1st through 8th place finishers in the pole vault. The kinematic analyses were divided into four phases: two dimensional run up analysis, and three dimensional analyses for the remaining plant, swing up, and extension phases. Run-up variables consisted of run up distance, number of steps, average step length, ratio of step length to height, average velocity at the final 5~10 m, approach position. Three variables were analyzed during plant: pole angle, center of gravity (COG) velocity, and COG takeoff angle. Swing up phase variables included: pole flection angle, COG velocity (horizontal, vertical, resultant), COG trajectory and bar approach angle of COG. Compared to the 2009 World Championships in Berlin, the average vault height increased, while run up velocity and approach position were almost unchanged. However, horizontal velocity during the last two steps of the final approach decreased noticeably compared to speeds from 1990. These results reflect the change in both technique and physical fitness in pole vaulters. During extension, the peak height of COG surpassed the clearance height by an average of 0.11m. These specific results can help coaches and athletes modify training and improve performance.

Microwave Absorbing Characteristics of Silicon carbide-ferrite surface Films Produced by Plasma-spraying(I) (플라즈마 용사방식에 의해 형성된 탄화규소-페라이트 표면층의 마이크로파 흡수특성(I))

  • Shin, Dong-Chan;Son, Hyon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.6
    • /
    • pp.580-588
    • /
    • 1992
  • Plasma-spraying was conducted to produced the microwave absorbing surface films on the alumi-num-alloy used for the fuselage to protect the aircraft against the RADAR detction. The surface films were produced by plasma-splaying the mecharucally mixed composite powders of the silicon carblde and Ni-Zn ferrite. This M /W absorbers were designed experimentally and fabricated trialty, as a result of which the rolative frequency bandwidth of 7.6 to 8.4% were obtained under the tolerance limits of the re-flection coefficients lower than -6dB(absorption ratio 75%), and the maximum absorption thickness becomes 0.5 to 0.5.imm, which Is much thinner than that of the conventional ones.

  • PDF

Kinetic comparative analysis of tennis backhand stroke for interdisciplinary convergence research (학제간 융합연구를 위한 테니스 백핸드 스트로크 동작의 운동역학적 비교 분석)

  • Cha, Jung-Hoon
    • Journal of Digital Convergence
    • /
    • v.13 no.7
    • /
    • pp.373-380
    • /
    • 2015
  • This study which was conducted on male tennis player on one hand(OH) & two hand(TH) backhand stroke and how both motion differed on low extremity movement with each feature analyzed in detail, the result as follow. The motion of TH based on resultant velocity, appeared to be a higher than OH, which was important variable in determining the ball speed. Contrary to TH where the player minimized the motion in the lower body and finalized a stroke through the turn of the trunk as if sticking the ball closed to the body, OH was carried out such that the player appeared to chase the ball. Whereas in OH, the knee joint extension moment was not found to be larger than TH, the opposite result came out for abduction moment and internal rotation moment. In the case of hip joint, consisted of extension, abduction and internal rotation moment, the outcome emerged to be greater for TH with conspicuous difference in abduction moment. Flection moment for TH overwhelmed in TH though both adduction and external rotation moment brought about similar outcome for both strokes.

Study on the Sun Screen Test Method using Elipsometer (분광타원해석기를 이용한 자외선 차단제의 평가방법 연구)

  • Kim, Joon-Woo;Lee, Jong-Soo;Lee, Ji-Hye;Choung, Suk-Jin
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.37 no.2
    • /
    • pp.137-141
    • /
    • 2011
  • Sunscreen is divided into the organic agent of UV absorption and inorganic agent of reflection. These are evaluated by sun protection factor (SPF) in-vivo test requiring high cost and time, while in-vitro tests are adopted commonly because of short test time, easy result collection. Generally, test method of SPF use SPF 290a by UV-vis spectrometer. The evaluate by SPF 290 has low reproducibility. Although analysis using UV-vis spectrometer has high reproducibility, it is hard to separated results of transmission, adsorption, and reflection. In this study, suggested method of elipsometer has some merit such as high reproducibility, easy separation of transmission/adsorption/re- flection, analysis using various incident angle. We tested the validity of elipsometer for SPF measurement, using commercially available sun-block (SPF 50).

Residual Stress Analysis of New Rails Using Contour Method (굴곡측정법을 이용한 신 레일의 잔류응력 분석)

  • Song, Min Ji;Choi, Wookjin;Lim, Nam-Hyoung;Kim, Dongkyu;Woo, Wanchuck;Lee, Soo Yeol
    • Journal of The Korean Society For Urban Railway
    • /
    • v.6 no.4
    • /
    • pp.393-399
    • /
    • 2018
  • It is well recognized that residual stresses of the rails, generated from the manufacturing process including roller straightening and heat treatment, play an important role in determining fatigue and fracture properties of the rails. Thus, it has been a challenge to measure the residual stresses accurately. In this work, contour method was employed to evaluate the residual stresses existing in interior of the rails. The cross section perpendicular to the longitudinal direction of the rail was cut at a very slow rate using electric discharge machining (EDM), after which a laser-based flexural measuring instrument enabled us to precisely measure the flection of the cross section. The measured data were converted into the residual stresses using the commercial finite element package, ABAQUS, through a user-defined element (UEL) subroutine, and the residual stresses of the new rails (50N, KR60, UIC60) with three different specifications were compared.

Analysis of Contact Pressure for Material Combination in Unicompartmental Knee Implant (반치환 무릎 인공관절에서의 재료조합에 따른 접촉압력 분석)

  • Noh, Tae-Heon;Chun, Heoung-Jae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.1
    • /
    • pp.23-29
    • /
    • 2018
  • In knee implants, contact pressure has a significant effect on wear. In this study, finite element analysis is performed using the knee implant model developed in the previous research. The contact pressures for a total of 10 knee implant materials combinations were analyzed using the combinations actually used in research and industry. In order to calculate the contact pressure, The load was applied when the flection angle of knee was $30^{\circ}$, $45^{\circ}$ and $60^{\circ}$. The result of contact pressure revealed the smallest contact pressure in the titanium alloy-UHMWPE combination. In the case of UHMWPE, contact pressure did not change much with any material used in the femur. Compared the combination with the largest contact pressure and the smallest contact pressure, the difference was 0.77%. On the other hand, Carbon / PEEK composites showed 5.3% difference when the contact pressure was the largest and the smallest. It can be seen that when the Carbon / PEEK composite material is used as the bearing part, the material of the femoral part affects the wear. This study will contribute to the prediction of knee implant wear and minimization of wear.