• Title/Summary/Keyword: flat system

Search Result 1,658, Processing Time 0.028 seconds

2D-3D convertible display system having a background of full-parallax integral images (완전시차 집적 영상 배경을 가지는 2D-3D 겸용 디스플레이 시스템)

  • Hong, Suk-Pyo;Shin, Dong-Hak;Kim, Eun-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.2
    • /
    • pp.369-375
    • /
    • 2009
  • In this paper, we propose a 2D-3D convertible display system having a background of full-parallax integral images. The proposed system is composed of integral imaging system and conventional 2D flat display and is able to operate either 3D mode or 2D mode. In 3D mode, the 3D image is generated by combining the 2D main image with the background image based on integral imaging. In 2D mode, the integral imaging system plays a role as the back-light of 2D flat display and then 2D image is observed through 2D flat display. To show the usefulness of the proposed system, we carry out the preliminary experiments and present the successful experimental results.

An Automated Process Planning System for Blanking or Piercing of Irregular Shaped Sheet Metal Product with Bending Processes (굽힘공정을 갖는 불규칙형상 박판제품의 블랭킹 및 피어싱용 공정설계 시스템)

  • Choi, J.C.;Kim, B.M.;Kim, C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.3
    • /
    • pp.18-23
    • /
    • 1998
  • This paper describes a research work of developing a computer-aided design of blanking and piercing for irregular-shaped sheet metal products. An approach to the CAD system is based on the knowledge-based rules. Knowledge for the CAD system is formulated from plasticity theories, experimental results and the empirical knowledge of field experts. The system has been written in AutoLISP on the AutoCAD with a personal computer and is composed of four main modules, which are input and shape treatment, flat pattern layout, production feasibility check, and strip layout module. Based on knowledge-based rules, the system is designed by considering several factors, such as radius and angle of bend. material and thickness of product, complexities of blank geometry and punch profile, and availability of press. This system is capable of unfolding a formed sheet metal part to give flat pattern and automatically account for the adjustment of bend allowances to match tooling requirements by checking the dimensions and relationships of parts of the folded product. Also this system can carry out a process planning which is obtained from results of irregular shape of product that was successful in production feasibility check module according to flat pattern layout and generate strip layout drawing in graphic forms. The developed system provides its efficiency for flat pattern layout, and strip layout for the irregularly shaped sheet metal products.

  • PDF

Development of Roll-to- Flat Thermal Imprinting Equipment and Experimental Study of Large Area Pattern Replication on Polymer Substrate

  • Lee, Moon-G.;Lan, Shuhuai;Lee, Soo-Hun;Lee, Hye-Jin;Ni, Jun;Sung, Yeon-Wook
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.3
    • /
    • pp.307-314
    • /
    • 2009
  • Large area micro pattern replication has promising application potential in many areas. Rolling imprint process has been demonstrated as one of the most competitive processes for such micro pattern replication, because it has advantages in low cost, high throughput and high efficiency. In this paper, we developed a prototype of roll-to-flat(R2F) thermal imprint system for large area micro pattern replication process, which is one of the key processes in the fabrication of flexible displays. Experimental tests were conducted to evaluate the feasibility of system and the parameters' effect on the process, such as flat mold temperature, loading pressure and rolling speed. 100mm $\times$ 100mm stainless steel flat mold and commercially available polycarbonate sheets were used for the tests. The experimental results showed that the developed R2F system is suitable for fabrication of various micro devices with micro pattern over large area.

  • PDF

A Study on the Effective Installation to the Apartment Through Solar Collector Performance Test (태양열 집열기 성능실험을 통한 공동주택 효율적 설치방안 연구)

  • Kim, Mi-Yeon;Choi, Byung-Do;Kim, Hyung-Geun;Park, Jin-Chul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.480-487
    • /
    • 2012
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

Unified equivalent frame method for post-tensioned flat plate slab structures

  • Choi, Seung-Ho;Lee, Deuck Hang;Oh, Jae-Yuel;Kim, Kang Su;Lee, Jae-Yeon;Lee, Kang Seok
    • Computers and Concrete
    • /
    • v.20 no.6
    • /
    • pp.663-670
    • /
    • 2017
  • The post-tensioned (PT) flat plate slab system is commonly used in practice, and this simple and fast construction method is also considered to be a very efficient method because it can provide excellent deflection and crack control performance under a service load condition and consequently can be advantageous when applying to long-span structures. However, a detailed design guideline for evaluating the lateral behavior of the PT flat plate slab system is not available in current design codes. Thus, typical design methods used for conventional reinforced concrete (RC) flat plate slab structures have inevitably been adopted in practice for the lateral load design of PT flat plate structures. In the authors' previous studies, the unified equivalent frame method (UEFM) was proposed, which considers the combined effect of gravity and lateral loads for the lateral behavior analysis of RC flat plate slab structures. The aim of this study is to extend the concept of the UEFM to the lateral analysis of PT flat plate slab structures. In addition, the stiffness reduction factors of torsional members on interior and exterior equivalent frames were newly introduced considering the effect of post-tensioning. Test results of various PT flat plate slab-column connection specimens were collected from literature, and compared to the analysis results estimated by the extended UEFM.

The Performance of Insulation of Noise by Air between Floors According to Structure Systems of Apartment (공동주택 구조형태별 층간 공기전달음 차단 성능)

  • Lee, Byung-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1152-1155
    • /
    • 2007
  • Lately concerns about structure have been increased by advantages of floor impact noise, poilitical induction and changeability. Hence, Flat Plate Structure has been constructed increasingly. This study shows the comparison of the performance of sound insulation of Flat Plate Structure System and the existing Wall Structure. For this study, taking the same level organization of Daelim Architectural Environmental Research Center, I found the performance of sound insulation between the upper and lower floors about Wall Structure and Flat Plate Structure. Consequently, the performance of sound insulation between upper and lower floors of Flat Plate Structure was 3-5dB higher was approximately 3-5dB higher than one of Wall Structure. Especially, the performance of sound insulation on the upper floor was 1-3dB higher than on the lower floor. In addition, as the result of comparing radiation sound which radiates from the wall of lower floors with each structure system, Flat Plate Structure was about 4dB higher with Rw than Wall Structure. As we see totally, the performance of sound insulation of Flat Plate Structure is highter than one of the Wall Structure. It is 3-5dB higher and the main reason for this result depends on the existence of the wall which can radiate sound and nonexistence.

  • PDF

Numerical Study on Seismic Resistance of Flat Plate (플랫플레이트의 내진성능에 대한 수치해석 연구)

  • 박홍근;최경규;황영현
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.971-976
    • /
    • 2001
  • Numerical studies were performed to investigate the seismic performance of Flat Plate System. For the numerical studies, a computer program for Finite Element analysis was developed. Parametric studies were performed to investigate variations of strength and ductility of flat plate with major parameters: gravity load, reinforcement ratio, thickness, column sizes. The numerical results provide a valuable insights on the behavior of flat plates. The comparison with the current design method shows that the current design methods for strength and ductility need to be improved in some aspects.

  • PDF

Estimation of morphological change using waterline method in the Ganghwado tidal flats

  • Lee, Yoon-Kyung;Ryu, Joo-Hyung;Eom, Jin-Ah;Jo, Min-Jeong
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.22-24
    • /
    • 2007
  • Waterline extraction is the one of widely used methods for studying changes in tidal flat environment and coastlines using multi-temporal optical images such as Landsat TM and Landsat ETM+. High dynamics of tidal currents and land reclamation which accelerate sedimentation and/or erosion cause waterline change in tidal flats. The amount of sediment deposited or eroded can be evaluated by precisely estimating waterline changes in tidal flats. The objective of this study is to detect the change of waterlines during 17 years and analyze the trends of erosion and sedimentation in the study areas. The Ganghwado tidal flat on the west coast of the Korean Peninsula was selected. The study area is famous for high dynamics of tidal currents and vast tidal flats. Land reclamation which has been carried out on a large scale is also considered as one of elements that have accelerated the environmental changes in this tidal flat. In this study, we acquired 26 waterlines from Landsat TM and Landsat ETM+ images. We extracted the waterline from each satellite image to generate a digital elevation map (DEM) which was used for reference and to compare with the other waterline which was extracted from DEM having a same tide. The result of comparison well depicted the areas of dominant sedimentation and erosion, and general trends of sedimentation and erosion according to sub-regions are also revealed during the investigation time. Results showed that erosion during a decade was dominant at the west of the Southern Ganghwado tidal flat, while sedimentation was dominant at the wide channel between the Southern Ganghwado tidal flat and the Yeongjongdo tidal flat. This area has been commonly affected by high currents and sedimentation energy. Although we were not able to verify the accuracy of the waterline changes, this result clearly showed the waterline change and therefore, the waterline extraction method used in this study has proven as an effective tool for long term tidal change estimation.

  • PDF

Analysis of Noise Power Spectrum According to Flat-Field Correction in Digital Radiography (디지털 의료영상에서 Flat-Field 보정에 따른 Noise Power Spectrum 분석)

  • Lee, Meena;Kwon, Soonmu;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.227-232
    • /
    • 2013
  • The pixels used in a digital X-ray detector have different sensitivities and offset values. A non-uniform image is consequently obtained. Flat-field correction was introduced to resolve this problem and carried out image preprocessing in a digital imaging system. Nevertheless, the non-uniform images caused by several reasons have been being occasionally acquired. In this study, the non-uniform images acquired in digital imaging systems were applied to flat-field correction, and NPSs were calculated and analyzed with those images before and after correction. It was confirmed that low frequency noise were effectively eliminated.

Determination of Equivalent Vehicle Load Factors for Flat Slab Parking Structures Using Artificial Neural Networks (인공 신경망을 이용한 플랫 슬래브 주차장 구조물의 등가차량하중계수)

  • 곽효경;송종영
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.2
    • /
    • pp.115-124
    • /
    • 2003
  • In this paper, the effects of vehicle loads on flat slab system are investigated on the basis of the previous studies for beam-gilder parking structural system. The influence surfaces of flat slab for a typical design section are constructed lot the purpose of obtaining maximum member forces under vehicle loads. In addition, the equivalent vehicle load factors for flat slab parking structures are suggested using artificial neural network. The network responses we compared with the results obtained by numerical analyses to verify the validation of Levenberg-Marquardt algorithm adopted as training method in this Paper. Many parameter studies for the flat slab structural system show dominant vehicle load effects at the center positive moments in both column and middle strips, like the beam-girder parking structural system.