• 제목/요약/키워드: flat system

검색결과 1,660건 처리시간 0.029초

수직진동 사용성을 고려한 플렛플레이트 두께 제안 (Proposing the Slab Thickness that Satisfies the Vertical Floor Vibration Criteria for Several Sizes of Flat Plate Floor System)

  • 이민정;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.600-603
    • /
    • 2003
  • The floor thickness in residential buildings may not satisfy the floor vibration criteria even though the thickness is determined by the serviceability requirements in current design provisons. Thus it is necessary to develop the procedure to determine slab thickness that satisfies the floor vibration criteria. In this study provide the methods to determine the slab thickness that satisfies the vertical floor vibration criteria for several sizes of flat plate floor system. Randomness inherent in young modulus of concrete and heel drop intensity was accounted. For this purpose Monte Carlo simulation procedure was adopted.

  • PDF

Effects of Mesh Size in a Flat Evaporator and Condenser Cooling Capacity on the Thermal Performance of a Capillary Pumped Loop

  • Boo, Joon-Hong
    • Journal of Mechanical Science and Technology
    • /
    • 제14권1호
    • /
    • pp.121-129
    • /
    • 2000
  • The thermal performance of a flat evaporator for capillary pumped loop (CPL) applications was investigated. Two to four layers of coarse wire screen wicks were placed onto the heated surface to provide irregular passages for vapor flow. The evaporator and condenser were separated by a distance of 1.2 m and connected by individual liquid and vapor lines. The wall material was copper and the working fluid was ethanol. The experimental facility utilized a combination of capillary and gravitational forces for liquid return, and distribution over the evaporator surface. The tubing used for vapor and liquid lines was 9.35 mm or less in diameter and heat was removed from the condenser by convection of air. A heat flux of up to $4.9{\times}10^4$ $W/m^2$ was applied to a flat evaporator having dimensions of 100 mm by 200 mm, 20 mm thick. The thermal resistance of the system as well as the temperature characteristics of the system was investigated as the evaporator heat flux and the condenser cooling capacity varied. The performance of the evaporator and effect of condenser cooling capacity were analyzed and discussed.

  • PDF

여러 가지 종류의 태양열 집열기 작동성능 비교 분석 연구 (The study on the comparison of the operation performance of different type of solar collectors)

  • 김휘동;백남춘;이진국;주문창
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.64.2-64.2
    • /
    • 2010
  • The objective of this study is to make a comparative study of the operation performance of different type of solar collectors. A flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector are used in this study. These 3 type of collectors are connected in series in the order of a flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector. This experimental facility is a kind of a solar system with a controller, a heat exchanger, a storage tank and a circulation pump. Each collector has a different collection area(flat-plate collector-$6.00m^2$ total area/$5.61m^2$ aperture area, double-glazed evacuated collector-$6.04m^2$ total area/$4.92m^2$ aperture area, single-glazed evacuated collector-$7.65m^2$ total area/$5.61m^2$ aperture area) and its performance characteristic respectively. The experiments have been demonstrated at around $70^{\circ}C$ operating temperature(flat-plate collector inlet temperature). The thermal collecting efficiencies of each collector are obtained under the different insolation and operation condition as a result.

  • PDF

초음파 센서 배열을 이용한 LED 면광원 부분점등 시스템 개발 (Development of Local Driving System for Flat LED Lamp Using Ultrasonic Sensors Array)

  • 유성호;이정훈;염정덕
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.67-73
    • /
    • 2011
  • A method obtaining position data(x, y) of object accurately is proposed by using a pair of ultrasonic sensors composed of one transmitter and two receivers. And the driving system which controls the light of flat LED lamp locally using array of ultrasonic sensors (3 transmitters and 6 receivers) is developed. As a result, measured values of y are relatively reliable due to its small average of absolute errors of 1.03[cm]. The measured values of x have average error of 8.52[cm], and it is a large value. However, the average error is decreased by 0.65[cm] after applying algorithm for error correction. The experiments to control the light of flat LED lamp locally with algorithm for error correction are carried out. From the result, measured values of x with average error of 0.97[cm] are obtained and they are very good approximations of actual values.

평판디스플레이의 대기중 분진농도에 따른 수명예측 시험방법 개발 (Development of Test Method for Flat Panel Display Life Time Prediction during Atmospheric Particle Exposure)

  • 유동현;이건호;최정욱;안강호
    • 반도체디스플레이기술학회지
    • /
    • 제12권4호
    • /
    • pp.45-48
    • /
    • 2013
  • The electronic device, such as flat panel display (FPD), is very important in our life as a means of communication between humans. Liquid crystal display (LCD), which is categorized as a flat panel display, has been used in many display products, especially in TV industry. An LED TV is composed of several electrical components, such as liquid critical module (LCM), analog to digital convertor (AD), power supplier, and inverter board. These modules are very vulnerable to particulate contamination, and causing malfunction or visibility degradation. In this study, we developed a test method for prediction of LCM's lifetime. The test system consists of carbon particle generation flame, dilution system, test chamber, and particle concentration monitoring instrument. Since the carbon particles are the most abundant in the atmosphere and easily absorb light, soot particles are used as a challenging material for this test. The concentration of generated soot particles is set around 4,000,000 #/cc, which is 400 times higher than that of usual atmospheric particles. Through this experiment, we deduced the relationship between the dust concentration and life time of the test specimen.

비접촉 평판 디스플레이 이송장치에서 양력을 고려한 평판 디스플레이의 처짐 해석 (Flat Panel Display Deflection Analysis Considering Lift Force in Non-Contact Flat Panel Display Conveyer System)

  • 황성현;최현창;노태정;손태영;박범석
    • 대한기계학회논문집A
    • /
    • 제32권5호
    • /
    • pp.451-457
    • /
    • 2008
  • Flat Panel Display(FPD) is widely used a video display terminals to consumer products of LCD and PDP. The contamination and damage were affected by using the previous contact conveyor's method. In this paper, it analyzes the FPD deflection to develop the non-contact FPD transfer process using lift force. Each conveyor's equipment is called a horizontal conveyor, vertical conveyor and robot pick-up equipment. As result of an analysis of FPD panel's deflection, a robot pick-up equipment has performed according to under the present conditions like panel's weight and loaded glass to move FPD panel from one place to other places properly. Results of the analysis showed 0.474 mm, 0.424 mm and 1.237 mm. Those values are lower than a predicted optimum values : 2 mm for both horizontal and vertical conveyers; 5 mm for robot pick-up equipment. Therefore, those results verify each equipment have safety and reliability.

UV Roll 임프린팅 공정을 이용한 렌티큘러 렌즈 제작 (Fabrication of Lenticular Lens by Continuous UV Roll Imprinting)

  • 명호;차주원;김석민;강신일
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.91-94
    • /
    • 2005
  • With increasing demands for large-scale micro-optical components in the field of digital display, the establishment of large-scale fabrication technology fur polymeric patterns has become a priority. The starting point of any polymer replication process is the mold, and the mold often has flat surface. However, It is very hard to replicate large-scale micro patterns using the flat mold, because the cost of large-scale flat mold was very high, and some uniformity and releasing problems were often occurred in large scale flat molding process. In this study, a UV roll imprinting system to overcome the financial and fabrication issues of large-scale pattern replication process was designed and constructed. As a practical example of the system, a lenticular lens with radius of curvature of $223{\mu}m$ and pitch of $280{\mu}m$, which was used to provide wide viewing angle in projection TV, was designed and fabricated. The roll stamper was fabricated using direct machining process of aluminum roll base. Finally, the shape accuracy and uniformity of roll imprinted lenticular lens sheet were measured and analyzed.

  • PDF

강성저감을 고려한 플랫슬래브 구조물의 지진해석 (Seismic Analysis of Flat Slab Structures considering Stiffness Degradation)

  • 김현수;이승재;이동근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.191-198
    • /
    • 2003
  • Flat slab system has been adopted in many buildings constructed recently because of the advantage of reduced floor heights to meet the economical and architectural demands. Structural engineers commonly use the equivalent frame method(EFM) with equivalent beams proposed by Jacob S. Grossman in practical engineering for the analysis of flat slab structures. However, in many cases, when it is difficult to use the EFM, it is necessary to use a refined finite element model for an accurate analysis. But it would take significant amount of computational time and memory if the entire building structure were subdivided into a finer mesh. An efficient analytical method is proposed in this study to obtain accurate results in significantly reduced computational time. The proposed method employs super elements developed using the matrix condensation technique and fictitious beams are used in the development of super elements to enforce the compatibility at the interfaces of super elements. The stiffness degradation of flat slab system considered in the EFM was taken into account by reducing the elastic modulus of floor slabs in this study. Static and dynamic analyses of example structures were peformed and the efficiency and accuracy of the proposed method were verified by comparing the results with those of the refined finite element model and the EFM.

  • PDF

평판철심 가동형 리니어 액츄에이터의 동특성 시뮬레이션 및 실험 (Experiments and Dynamics Simulation of a Moving Flat Core Type LOA)

  • 장석명;조한욱;이성호;권철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.663-665
    • /
    • 2002
  • Moving flat core type LOA consists of iron flat core as a mover and electric magnet as a stator and operated by electromagnetic force between mover and stator. First, this paper describes the voltage equation of coil and the mechanical equation of motion. Secondly, the dynamic simulation algorithm is proposed, and system control constant-inductance, resistance-were carried by exciting coil. Finally, we turned out the driving system and the dynamic characteristics of current, voltage and displacement is confirmed by experiment.

  • PDF

H$\bate$CCD 측광의 정확도 (THE ACCURACY OF H$\bate$CCD PHOTOMETRY)

  • 김철희;김승리
    • Journal of Astronomy and Space Sciences
    • /
    • 제11권2호
    • /
    • pp.208-231
    • /
    • 1994
  • We have undertaken CCD observations of fie이 standard stars with H$\beta$ photometric system to investigate the reliability of H$\beta$ CCD photometry. Flat fielding with dome flat and sky flat for H$\beta$w and H$\beta$n filter was compared with that of B filter in UBV system and, from these, we have not found any difference. It was confirmed that there is a good linear relationship between our H$\beta$ values observed with 2.3m reflector and standard values. However, H$\beta$ values observed with 60cm reflector at Sobaeksan Astronomy Observatory showed very poor relationship. To investigate the accuracy of H$\beta$ CCD photometry for fainter objects, open cluster NGC2437 was observed and reduced with DoPHOT, and the results were compared with those for photoelectric photometry of Stetson(1981).

  • PDF