• 제목/요약/키워드: flat plate system

검색결과 344건 처리시간 0.03초

여러 가지 종류의 태양열 집열기 작동성능 비교 분석 연구 (The study on the comparison of the operation performance of different type of solar collectors)

  • 김휘동;백남춘;이진국;주문창
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.64.2-64.2
    • /
    • 2010
  • The objective of this study is to make a comparative study of the operation performance of different type of solar collectors. A flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector are used in this study. These 3 type of collectors are connected in series in the order of a flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector. This experimental facility is a kind of a solar system with a controller, a heat exchanger, a storage tank and a circulation pump. Each collector has a different collection area(flat-plate collector-$6.00m^2$ total area/$5.61m^2$ aperture area, double-glazed evacuated collector-$6.04m^2$ total area/$4.92m^2$ aperture area, single-glazed evacuated collector-$7.65m^2$ total area/$5.61m^2$ aperture area) and its performance characteristic respectively. The experiments have been demonstrated at around $70^{\circ}C$ operating temperature(flat-plate collector inlet temperature). The thermal collecting efficiencies of each collector are obtained under the different insolation and operation condition as a result.

  • PDF

수정된 등가골조법을 이용한 플랫플레이트 시스템의 설계 (Design of Flat Plate Systems Using the Modified Equivalent Frame Method)

  • 박영미;오승용;한상환
    • 콘크리트학회논문집
    • /
    • 제20권1호
    • /
    • pp.35-41
    • /
    • 2008
  • 플랫플레이트 시스템은 주로 전단벽과 가새 골조와 같은 횡력저항 시스템과 함께 중력저항 시스템으로 사용된다. 따라서 지진과 같은 횡하중이 작용할 때, 중력저항 시스템은 중력하중에 대한 전달 능력을 유지하면서 일체로 연결된 횡력저항 시스템의횡변위를 견딜 수 있어야 한다. 또한 플랫플레이트 시스템은 지진에 대한 특별 상세조건에 만족하면 중간 모멘트 골조로써 횡력저항 시스템으로도 사용할 수 있다. 그러나 횡하중이 작용하는 경우 플랫플레이트 시스템은 횡변위와 불균형모멘트로 인한 뚫림 전단의 위험성은 더욱 커지게 된다. 따라서 플랫플레이트 시스템을 중력 저항 또는 횡력 저항 시스템으로 설계하는 모든 경우에 중력하중뿐만 아니라 횡하중하의 설계 내력 (모멘트와 전단력)과 변위 등의 합리적인 예측은 매우 중요하다. ACI 318 (2005)에서는 중력하중에 대한 해석시 직접설계법과 등가골조법을 제시하고 있으며, 횡하중에 대한 해석으로 유한요소법, 유효보폭법, 등가골조법을 허용한다. 이러한 해석법은 각각 장단점을 갖고 있으며, 매우 광범위한 해석 결과를 보인다. 따라서 구조 설계자들은 적절한 해석법의 선택과 해석 결과를 분석하는데 어려움을 갖는다. 본 연구의 목적은 플랫플레이트 해석법에 대한 구조 설계자들이 적절한 해석법을 선택할 수 있도록 하고, 횡하중에 대한 해석 방법으로 수정된 등가골조법의 실용성을 검증하고자 하였다. 이를 위하여 중력하중과 횡하중을 받는 7층의 플랫플레이트 구조물에 대한 내부력과 횡변위를 대상으로 유한요소해석을 수행하고 각 골조해석법의 결과를 비교하였다. 또한 각 골조해석법의 정확성은 기존 플랫플레이트 슬래브 구조물의 실험 결과와 비교하여 검증하였다.

불균등 휨모멘트를 받는 플랫 플레이트-기둥 접합부에 대한 해석연구 (Numerical Study on Interior Flat Plate-Column Connections Subjected to Unbalanced Moment)

  • 최경규;황영현;박홍근
    • 콘크리트학회논문집
    • /
    • 제14권6호
    • /
    • pp.949-960
    • /
    • 2002
  • 횡하중을 받는 플랫 플레이트 구조는 슬래브-기둥 접합부의 뚫림전단파괴에 대해 취약하며, 이러한 접합부의 취성적 파괴를 방지하기 위해 접합부의 강도 및 연성능력이 반드시 확보되어야 한다. 그러나 플랫 플레이트 시스템의 거동은 대단히 복잡하고 실제 하중재하방식과 경계조건을 정확히 실현하기는 매우 어려우므로, 이전의 실험연구로부터 강도 및 연성능력에 대한 신뢰할 만한 실험결과를 얻기가 쉽지 않다. 본 연구에서는 이러한 실험연구의 어려움을 보완하기 위하여 연속 플랫 플레이트의 내부 접합부에 대해 수치해석 연구를 수행하였다. 이를 위해 비선형 유한요소해석을 위한 컴퓨터 프로그램을 개발하였고, 기존의 실험결과와의 비교를 통해 그 유효성을 검증하였다. 변수연구를 통하여 접합부 주위의 휨모멘트, 전단력, 비틀림모멘트의 변화를 분석하였고, 분석결과에 근거해서 기존 설계방법에서 개선되어야 할 사항을 검토하였다. 본 연구결과는 후속논문에서 불균등 휨모멘트를 받는 접합부에 대한 설계방법을 개발하는데 사용될 것이다.

콘크리트 충전각형강관 (CFT)기둥과 철근콘크리트 무량판 접합부 상세 및 설계법 개발을 위한 실험연구 (An Experimental Study for Development of Details and Design Method of CFT Column-to-RC Flat Plate Connections)

  • 이철호;김진원;오정근
    • 한국강구조학회 논문집
    • /
    • 제17권4호통권77호
    • /
    • pp.481-490
    • /
    • 2005
  • 본 논문은 중력하중의 지배를 받는 CFT기둥-RC 무량판 접합부의 실물대 실험결과를 요약한 것이다. CFT구조는 여러 가지 구조 및 시공상의 장점으로 인하여 국내 건설 현장에서 상대적으로 짧은 시간에 폭넓게 수용되고 있다. 주차장 용도로 주로 사용되는 지하층은 철근콘크리트 무량판으로 시공하여 경제성을 도모하는 것이 국내에서 일반적으로 요구되는 시공관행이다. 그러나 CFT기둥-RC 무량판 접합부의 효율적인 디테일은 아직 국내 외적으로 제시된 바가 없어서 이 분야의 연구가 매우 필요한 실정이다. 현장 시공시 경제성을 극대화할 수 있는 몇 가지 전략을 기초로 해서, 여러 가지 접합 상세를 제안하였고 실험을 통하여 검증하였다. 실험결과 본 연구에서 제시된 CFT기둥-RC 무량판 접합 상세의 펀칭강도 및 강성이 RC 무량판 접합부와 동등하거나 이를 상회하는 것을 확인할 수 있었다.

플랫 플레이트 슬래브와 H형강 기둥 접합부의 구조 성능에 관한 실험적 연구 (An Experimental Study on Structural Performance of H-Steel or SRC Column and Flat Plate Slab Connection)

  • 윤명호;이윤희;유홍식;김진원
    • 복합신소재구조학회 논문집
    • /
    • 제5권2호
    • /
    • pp.9-14
    • /
    • 2014
  • Main topics in this study is a new structural detail for connection between H-Steel or SRC column and flat plate slab. We carried out to evaluate the punching shear performance of H-steel or SRC column + RC slab system for vertical load and lateral load. From the test results structural characteristics - yield moment, yield rotation, maximum moment, deformation capabilities ect. - are obtained and evaluated. In this paper as a shear reinforcement for supporting region of plate closed stirrup type and shear band are used, and their test results are compared.

초음속 충돌제트에 대한 수치적 연구와 응용 (Prediction of Supersonic Jet Impingement on Flat Plate and Its Application)

  • 이광섭;홍승규;박승오;배연숙
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.225-228
    • /
    • 2002
  • Supersonic jet impingement on a flat plate has been investigated to show the flow physics for different jet heights and to demonstrate the adequacy of the characteristics-based flux-difference Wavier-Stokes code Current study also compares the steady-state solutions obtained with variable CFL number for different grid spacing with the time-accurate unsteady solutions using the inner iterations, displaying a good agreement between the two sets of numerical solutions. The unsteady nature of wall fluctuations due to bouncing of the plate shock is also uncovered for high pressure ratios. The methodology is then applied to a complex vertical launcher system where the jet plume hits the bottom wail, deflects into the plenum and eventually exits through the vertical uptake. Flow structures within vertical launcher system are captured and solutions are partially verified against the flight test data. Present jet impingement study thus shows the usefulness of CFD in designing a complex structure and predicting flow behavior within such a system.

  • PDF

The Coupling of Conduction with Free Convection Flow Along a Vertical Flat Plate in Presence of Heat Generation

  • Taher, M.A.;Lee, Yeon-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권7호
    • /
    • pp.833-841
    • /
    • 2007
  • The aim of this paper is to analyze the conjugate problems of heat conduction in solid walls coupled with laminar free convection flow adjacent to a vertical flat plate under boundary layer approximation. Using the similarity transformations the governing boundary layer equations for momentum and energy are reduced to a system of partial differential equations and then solved numerically using Finite Difference Method(FDM) known as the Keller-box scheme. Computed solutions to the governing equations are obtained for a wide range of non-dimensional parameters that are present in this problem, namely the coupling parameter P. the Prandtl number Pr and the heat generation parameter Q. The variations of the local heat transfer rate as well as the interface temperature and the friction along the plate and typical velocity and temperature profiles in the boundary layer are shown graphically. Numerical solutions have been consider for the Prandtl number Pr=0.70

충돌판(衝突板) 근방(近傍)에 배열(配列)된 2차원(次元) Rod가 충돌분류(衝突噴流) 열전달(熱傳達)에 미치는 영향(影響)[2]:Rod 피치변화(變化)에 대한 효과(效果) (Heat Transfer Augmentation on Flat Plate with Two-Dimensional Rods in Impinging Air Jet System[2]:Effect of rod pitch)

  • 이용화;서정윤
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.182-189
    • /
    • 1989
  • The propose of this study is augmentation of heat transfer without additional external power in 2-dimensional impinging air jet. The passive heat transfer augmentation method tried in this experimental study is placement of rod bundles with the clearance, 2mm, in front of the heat transfer surface. The effects of pitch distance among rods and nozzle-to-target plate distance are investigated. The overall heat transfer rate of flat plate with rods reaches maximum at H/B=10 and P=40mm, and for H/B=2 and P=40mm the augmentation rate of heat transfer becomes maximum to a value which is about 1.57 times that of the flat plate without rods.

  • PDF

수직진동 사용성을 고려한 플렛플레이트 두께 제안 (Proposing the Slab Thickness that Satisfies the Vertical Floor Vibration Criteria for Several Sizes of Flat Plate Floor System)

  • 이민정;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.600-603
    • /
    • 2003
  • The floor thickness in residential buildings may not satisfy the floor vibration criteria even though the thickness is determined by the serviceability requirements in current design provisons. Thus it is necessary to develop the procedure to determine slab thickness that satisfies the floor vibration criteria. In this study provide the methods to determine the slab thickness that satisfies the vertical floor vibration criteria for several sizes of flat plate floor system. Randomness inherent in young modulus of concrete and heel drop intensity was accounted. For this purpose Monte Carlo simulation procedure was adopted.

  • PDF

KBC2008(안)에 근거한 무량판구조의 횡력저항시스템 (Lateral Force Resisting System of Flat Plate Structure based on KBC 2008 Draft)

  • 김도현;이현호;김영식;우성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.871-874
    • /
    • 2008
  • KBC 2005를 처음 적용할 때 많은 구조엔지니어들이 무량판 구조에 대한 횡력저항시스템 선정과이에 따른 상세적용에 많은 어려움이 있었다. 현재 KBC 2005에 대한 개정작업이 진행중에 있다. 이러한 시점에서 최근 개정 중인 건축구조기준의 개정안을 토대로 향후 개정안에 적용가능한 구조시스템을 미리 살펴볼 필요가 있다. KBC 2008(안)의 경우 내진설계범주에 따른 시스템의 높이제한, 특수전단벽과 같은 특수상세, 전단벽-골조 상호작용시스템과 같은 새로운 시스템의 도입으로 구조설계자가 현행 기준보다 시스템에 대하여 휠씬 더 다양한 선택이 가능할 것으로 판단된다.

  • PDF