• Title/Summary/Keyword: flat fluorescent lamp

Search Result 62, Processing Time 0.026 seconds

High Efficiency Alternating Current Driver for Capacitive Loads Using a Current-Balance Transformer

  • Baek, Jong-Bok;Cho, Bo-Hyung;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.97-104
    • /
    • 2011
  • This paper proposes a new alternating current driving method for highly capacitive loads such as plasma display panels or piezoelectric actuators, etc. In the proposed scheme, a current balance transformer, which has two windings with the same turn-ratio, provides not only a resonance inductance for energy recovery but also a current balance among all of the switching devices of the driver for current stress reduction. The smaller conduction loss than conventional circuits occurs due to the dual conduction paths which are parallel each other in the current balance transformer. Also, the leakage inductances of the transformer are utilized as resonant inductors for energy recovery by the series resonance to the capacitive load. Furthermore, the resonance contributes to the small switching losses of the switching devices by soft-switching operation. To confirm the validity of the proposed circuit, prototype hardware with a 12-inch mercury-free flat fluorescent lamp is implemented. The experimental results are compared with a conventional energy-recovery circuit from the perspective of luminance performances.

Development of Flat Fluorescent Lamp (FFL) Inverter for Improvement of LCD TV Backlight Driving Characteristics (LCD TV 백라이트 구동특성 개선을 위한 면광원 인버터 개발)

  • Hur, Jeong-Wook;Lim, Sung-Kyoo
    • 전자공학회논문지 IE
    • /
    • v.44 no.2
    • /
    • pp.47-53
    • /
    • 2007
  • The inverter using level control block (LCB) was developed to drive LCD TV backlight using FFL light source. The FFL striking time, time for brightness stabilization, and lamp current of FFL backlight were shown to improve by applying LCB in the inverter. It was also shown that the stable driving of LCD TV FFL backlight with the inverter using LCB was possible over the wide temperature range.

Discharge and Characteristic of Hg-free Flat Fluorescent Lamp (무수은 평판형 형광램프의 제작 및 방전특성)

  • Lee, Myoung-Ho;Lim, Min-Su;Lee, Mun-Ju;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.624-627
    • /
    • 2004
  • 본 논문은 LCD Backlight로 사용되고 있는 CCFL의 문제점을 해결하기 위해 간단한 구조를 가지는 mercury-free, Xe 평판형 형광램프에 대한 연구를 하였다. 일반적으로, 수은을 포함한 형광램프는 낮은 온도에서의 휘도문제와 상대적으로 긴 점등시간, 수명과 특히, 환경 문제가 있다. 본 논문에는 화학적으로 안정한 불활성 가스인 Xe을 사용함으로써 기존의 백라이트가 가지고 있는 문제점을 해결하였다. 제작된 8인치$(200{\times}156{\times}10mm)$ 램프는 AC 펄스 전압에 의해 높은 균일도, 안정한 방전, 우수한 전기적 및 광학적 특성을 가진다. 또한 본 연구에서, 무수은 Xe 평판형 형광램프의 전극폭에 대한 전기적 및 광학적 실험을 통하여 90[%]의 균일도에서 $7,000[cd/m^2]$의 휘도와 30[lm/W]의 효율을 얻었다.

  • PDF

Discharge characteristics of FFL as the change of discharge space dimensions (방전공간 치수 변화에 따른 FFL(Flat Fluorescent Lamp)의 방전특성)

  • Yun, Seong-Hyun;Park, Cheol-Hyun;Cho, Min-Jeong;Lim, Min-Su;Kwon, Sun-Suk;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.497-499
    • /
    • 2000
  • The characteristics of Xe discharge lamp are described in this paper. In this paper, FFL is changed discharge space dimensions like discharge space gap, phosphor layer and dielectric layer thickness to find FFL with high efficiency.

  • PDF

Feasibility Analysis for Introducing ESCO Program of LED Luminaire Replacements in Schools

  • Shin, Hyunman;Jang, Woojin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Public institutions should replace their luminaires with LED lighting by 2020 to save energy. Because the LED lighting installation rate in schools has not yet reached the legal goal, the ESCO program feasibility was investigated. The amount of electricity used, electric rates, times of use in classrooms and fluorescent lighting maintenance costs etc., as well as the elements of lighting maintenance were analyzed. In the case of schools, the lamp usage time was so short that the ESCO projects with only energy savings were impossible. In order to execute the ESCO projects, the maintenance cost savings by replacing an existing luminaire should be considered and the introduction of the relatively cheaper tube type LED lamp than the flat type LED luminaire was required.

Discharge Characteristic of Surface Type FFL as LCD Backlighting according to Dielectric Layer (LCD 후면광원용 면방전형 FFL의 Dielectric Layer에 따른 방전 특성)

  • 임민수;정득영;윤성현;임기조;권순석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.177-180
    • /
    • 1999
  • In this paper, we studied Surface Discharge Type Flat Fluorescent Lamp(FFL) with High Luminance for LCD Backlighting. This lamp is Surface Discharge Type structure with a pair of Sodalime glass, insulator layer, phosphor layer, and Xe gas gap. There are two influences of Electric field on different dielectric thickness. The Electric field difference at the dielectric layer itself enhances minimum value of firing voltage and luminance uniformity. So, we measured the Electric filed at 0.5mm, 1mm gap length and discharge voltage for difference dielectric layer thickness. In experiment result, the thicker dielectric layer has higher firing voltage and lower current.

  • PDF

Properties of Longitudinal & Transverse Discharge in a Tubular Fluorescent Lamp (직관형 형광램프의 종단방전과 횡단방전의 특성)

  • Chung, J.Y.;Kim, J.H.;Jeong, J.M.;Jin, D.J.;Kim, H.C.;Bong, J.H.;Hwang, H.C.;Lee, M.S.;Koo, J.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.322-330
    • /
    • 2008
  • The properties of discharge, luminance, and spectroscopy are investigated in a longitudinal and transverse discharge fluorescent lamps with tube of outer diameter 4 mm. The sample lamps are prepared to be three kinds of gas composition such as mercury lamps of Ne(95%)+Ar(5%)+Hg(2 mg), the mercury-free lamps of Xe 100% and Ne+Xe(4%). The gas pressure is in the range of $5{\sim}300\;Torr$. In the mercury lamps, the longitudinal discharge having a positive column is high in luminance and efficiency, while the transverse discharge is no luminance at all. In the Xe-lamps, the transverse discharge shows relatively good in efficiency as compared with the longitudinal discharge which has a high discharge voltage and a low luminance and efficiency. In the transverse discharge of relatively high efficiency, a pure Xe(100%) gas discharge has a higher efficiency than the mixture gas of Ne+Xe(4%). Through these experiments, the properties of mercury and xenon lamps are verified. In the mercury lamps, the longitudinal discharge of tubular fluorescent lamps is high in luminance and efficiency, while the transverse discharge of flat panel fluorescent lamps are low in luminance efficiency. In the mercury-free lamps, the flat fluorescent lamps of transverse discharge having a high pressure ${\sim}100\;Torr$ with the pure Xe-gas are verified to be suggestable.

Development of Vision system for Back Light Unit of Defect (백라이트 유닛의 결함 검사를 위한 비전 시스템 개발)

  • Han, Chang-Ho;Oh, Choon-Suk;Ryu, Young-Kee;Cho, Sang-Hee
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.4
    • /
    • pp.161-164
    • /
    • 2006
  • In this thesis we designed the vision system to inspect the defect of a back light unit of plat panel display device. The vision system is divided into hardware and inspection algorithm of defect. Hardware components consist of illumination part, robot-arm controller part and image-acquisition part. Illumination part is made of acrylic panel for light diffusion and five 36W FPL's(Fluorescent Parallel Lamp) and electronic ballast with low frequency harmonics. The CCD(Charge-Coupled Device) camera of image-acquisition part is able to acquire the bright image by the light coming from lamp. The image-acquisition part is composed of CCD camera and frame grabber. The robot-arm controller part has a role to let the CCD camera move to the desired position. To take inspections of surface images of a flat panel display it can be controlled and located every nook and comer. Images obtained by robot-arm and image-acquisition board are saved on the hard-disk through windows programming and are tested whether there are defects by using the image processing algorithms.

Ultra High Luminance and Luminous Efficacy MFFL (Mercury-free Flat Fluorescent Lamp) for Scanning Backlights of LCD TVs

  • Seo, In-Woo;Jung, Jae-Chul;Oh, Byung-Joo;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.231-234
    • /
    • 2009
  • In order to realize the high luminance and luminous efficacy MFFLs for LCD backlights, we optimized the phosphor profile to enlarge the surface area. The MFFL with the new phosphor profile shows a very wide luminance range from 2,600 to 17,000 nit with the corresponding luminous efficacy from 66 to 32.5 lm/W. The results were obtained with the color coordinate of the phosphor to be around (0.25, 0.23). And the single cell is expanded into a multi-structured configuration to realize a 32 inch-sized lamp by a simple repetition of the single cells, and a new driving scheme is proposed for an adaptive local dimming and scanning drive using dual auxiliary electrodes and bipolar drive scheme. Especially the ultra high luminance and luminous efficacy results suggest the duty time of illumination of the backlight unit can be significantly reduced.

  • PDF

A design of Fly-Back electronic ballast for Xeon Dielectric Barrier Discharge Flat Fluorescent Lamp. (제논 유전체 장벽 방전형 평판형광림프용 Fly-Back방식 전자석 안정기 설계)

  • Cho, Ho-Yon;Lee, Hyun-Heang
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.111-113
    • /
    • 2007
  • 본 논문에서는 제논 유전체 장벽 방전형 평판형광램프용 Fly-Back방식 전자식 안정기를 설계하였다. 본 전자식 안정기는 Fly-Back방식의 능동형 역률 보상 회로와 인버터회로를 사용하여 기존의 Sine wave의 형태가 아닌 펄스파 형태의 출력을 만드는 고역률, 고신뢰성 전자식 안정기를 제작하였다. 제논 평판형광램프의 점등전압은 고압이 사용되므로 램프 파손의 경우와 무부하의 경우로부터 사고를 방지하기 위해 보호회로를 사용하여 이상전압, 이상전류에 의한 사고를 차단했다.

  • PDF