• Title/Summary/Keyword: flammable

검색결과 511건 처리시간 0.025초

지하주차장 내 수소연료 자동차의 수소 누설로 인한 수소 확산에 대한 수치해석 연구 (A NUMERICAL SIMULATION OF HYDROGEN DIFFUSION FOR THE HYDROGEN LEAKAGE FROM FCV IN UNDERGROUND PARKING LOT)

  • 최종락;허남건;이은덕;이광범
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.477-482
    • /
    • 2011
  • In the present study, the diffusion process of hydrogen leaking from a FCV (Fuel Cell Vehicle) in an underground parking lot was analyzed by numerical simulations in order to assess the risk of a leakage accident. The temporal and spatial changes of the hydrogen concentration as well as the flammable region in the parking lot were predicted numerically. The effects of the leakage flow rate and an additional ventilation fan were investigated to evaluate the ventilation performance in the parking lot to relieve the accumulation of the leaked hydrogen gas. The present numerical analysis can provide useful information such as the distribution of the leaked hydrogen concentration for safety of various hydrogen applications.

  • PDF

에스테르류의 연소열을 이용한 폭발한계의 예측 (Estimation of Explosion Limits by Using Heats of Combustion for Esters)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.66-71
    • /
    • 2010
  • 화학공정에서의 안전하고 최적화된 조작과 내재되어 있는 화재 및 폭발 위험성 평가를 위해서 연소 특성치를 알아야 한다. 폭발한계는 가연성물질의 화재 및 폭발위험성을 결정하는데 주요한 특성치 가운데 하나이다. 본 연구에서, 에스테르류의 폭발하한계와 상한계에 대해 연소열을 이용하여 예측하였다. 제시된 예측식에 의한 예측값은 문헌값과 적은 오차범위에서 일치하였다. 제시된 방법론을 사용하여 다른 가연성 에스테르류의 폭발한계 예측이 가능해졌다.

정전기(靜電氣) 방전(放電)과 삼성분계(三成分系) 가연성(可燃性) 혼합기체(混合氣體)의 최소점화(最小點火) Energy 측정(測定)에 관한 연구(硏究) (Electrostatic Discharge and the Minimum Ignition Energy Measurement of Three-Component Flammable Gas Mixtures)

  • 이관형;최상원;정재희;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1819-1823
    • /
    • 1997
  • When flammable gases are mixed with air or oxygen in the explosion concentration range and are ignited by sufficiently large electrostatic discharge energy, they may explode causing severe disaster in workplaces. The minimum ignition energy (MIE) of single gas-air mixtures has been already investigated by many researchers, but the MIE of mixtures of more than three substances is not examined yet. The purpose of this study is to investigate the MIE of several three-component gas mixtures experimentally. The result of our experiment shows that the MIE of some gas mixtures is quite different from that we expected based on the characteristics of individual gas-air mixture.

  • PDF

다공질 ZnO의 전기적 특성, 환원성 가스 감응 특성 및 습도의 영향 (Electrical Conductivity, Flammable Gas Response and Humidity Effect of Pporous ZnO)

  • 윤당혁;최경만
    • 한국세라믹학회지
    • /
    • 제32권11호
    • /
    • pp.1283-1291
    • /
    • 1995
  • The electrical conductivity, flammable gas response and their humidity effect of porous ZnO, added with 5wt% corn starch as the fugitive phase, were examined. Porous ZnO showed different conductivity curves during increasing and decreasing temperature, and its electrical conductivity decreased rapidly by desorption of OH- between 20$0^{\circ}C$ and 35$0^{\circ}C$ when the temperature increased in dry air. The CO gas sensitivity of starchadded ZnO samples was higher than that of ZnO without starch addition. The sensitivity of porous, starchadded ZnO to 200ppm CO gas was much less in humid atmosphere than in dry atmosphere since water vapor increased the conductivity of porous ZnO in air, but decreased the conductivity in CO. Maximum sensitivity to 200 ppm CO gas balanced by air was about 100 in dry atmosphere and about 15 in RH 23% atmosphere.

  • PDF

필로티건축물의 화재확산방지를 위한 시범시공 (Trial Construction for the Prevention of Fire Spread in Piloti Building)

  • 이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.87-88
    • /
    • 2019
  • In case of Korea, The Large-scale fire is consistently being such as 2015 Uijeongbu Fire, 2017 Jecheon Fire, 2018 Sejong Hospital Fire. Such a fire has a problem that the fire is spreading upper due to external flame spread. As a countermeasure the fire safety, the study about axial temperature prediction of external flame spread is consistently doing. But in korea, Vertical spandrel is specified as 40cm, and improvement is urgently needed. In this study, a repair material was selected to prevent the fire from spreading to a building where a flammable exterior material was installed and then pilot construction was carried out. Also, fire safety measures for buildings constructed with flammable exterior materials were examined.

  • PDF

단일구획실험을 통한 화재안전설계에 관한 기초적 연구 (A Basic Study on the Fire Experiment of a Single Area for Fire Safety Design.)

  • 김동은;윤웅기;서동구;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.110-111
    • /
    • 2013
  • This research studies in the field of domestic fires are an issue in many scientific fire research as a research method to validate the domestic environment and ISO-9705 housing on the basis of experiments in virtual space by making a single fire compartment space for conducting experiments and Appearance of a fire occurring within each flammable Heat Release Rate analysis was carried out mainly. Placed within the space of one flammable HRR calculated as the sum of the number of single-room fire experiments conducted and the results compared with the value in comparing the conduct of fire locations and fire load within the building area of the future, the HRR value represents the change in domestic a consideration of the safety of the building is to propose matters.

  • PDF

The Measurement and Prediction of Minimum Flash Point Behaviour for Flammable Binarry Solution Using Pensky-Martens Closed Cup Tester

  • Ha, Dong-Myeong;Choi, Yong-Chan;Lee, Sung-Jin
    • International Journal of Safety
    • /
    • 제9권2호
    • /
    • pp.6-10
    • /
    • 2010
  • The flash point of liquid solution is one of the most important flammability properties that used in hazard and risk assessments. Minimum flash point behaviour (MFPB) is showed when the flash point of a liquid mixture is below the flash points of the individual components. In this paper, the lower flash points for the flammable binary system, n-decane+n-octanol, were measured by Pensky-Martens closed cup tester. This binary mixture exhibited MFPB. The measured flash points were compared with the values calculated by the Raoult's law and the optimization method using van Laar and UNIQUAC equations. The optimization method were found to be better than those based on the Raoult's law, and successfully estimated MFPB. The opimization method based on the van Laar equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the UNIQUAC.

Setaflash 장치를 이용한 노말 알코올류의 상부인화점 측정에 의한 폭발상한계의 예측 (Prediction of Upper Explosion Limits(UEL) by Measurement of Upper Flash Point Using Setaflash Apparatus for n-Alcohols)

  • 하동명
    • 한국안전학회지
    • /
    • 제25권2호
    • /
    • pp.35-40
    • /
    • 2010
  • Explosion limit and flash point are the major combustion properties used to determine the fire and explosion hazards of the flammable substances. In this study, in order to predict upper explosion limits(UEL), the upper flash point of n-alcohols were measured under the VLE(vapor-liquid equilibrium) state by using Setaflash closed cup tester(ASTM D3278). The UELs calculated by Antoine equation using the experimental upper flash point are usually lower than the several reported UELs. From the given results, using the proposed experimental and predicted method, it is possible to research the upper explosion limits of the other flammable substances.

3성분계 인화성 혼합가스의 최소점화에너지 측정에 관한 연구 (Measurement of Minimum Ignition Energy by Electrostatic Discharge for Flammable Ternary Gas Mixtures)

  • 최상원
    • 한국안전학회지
    • /
    • 제28권1호
    • /
    • pp.29-34
    • /
    • 2013
  • When flammable gases are mixed with air or oxygen in the explosion concentration range and are ignited by sufficiently large electrostatic discharge energy, they may explode causing severe disaster in workplace. The minimum ignition energy(MIE) of single gas-air mixtures has been already investigated by many research, but the MIE of mixtures of more than ternary gas mixture is not examined yet. The purpose of this study is to investigate the MIE of a ternary gas(methane, ethylene, hydrogen, propane) mixtures experimentally. The results of our experiment show that the ignition of a methane-ethylene-air, methane-hydrogen-air, methane-propane-air, ethylene-hydrogen-air, ethylene-propane-air and hydrogen-propane-air mixture due to electrostatic discharge energy primarily depends on that the mixture: the MIE decreases gradually with the increase of having the lower MIE than other mixture ratio in the normal atmospheric pressure.

저선회 연소기의 선회각도에 따른 영향 (Effect of Swirl Angles in Low-Swirl Combustor)

  • 정황희;최인찬;이기만
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.123-125
    • /
    • 2015
  • A study has been conducted to investigate the effect of swirl angle in low swirl combustor. In this study, the employed swirl angles were $28^{\circ}$, $32^{\circ}$ and $37^{\circ}$. Direct flame photos show that the width of the flame is expanded and the length of the flame is shortened when swirl angle is increased. Also, as the swirl angle was increased, the flame stability region could be widened due to the expansion of lower flammable limit. Between 3 and 7kW, CO emissions was below 10 ppm and NOx emissions was also below 27 ppm at $O_2$ 15% basis over the lean burning range of 0.6 < ${\Phi}$ < 0.9. From this investigation of stability expansion effect and emission performance, it was identified that the swirl angle $37^{\circ}$ is most suitable swirling condition in the low swirl model combustor.

  • PDF