• 제목/요약/키워드: flammable

검색결과 509건 처리시간 0.026초

ABS/AES 블렌드의 물성에 관한 연구 (Studies on the Properties of ABS/AES Blonds)

  • 강동일;하창식;조원제
    • Elastomers and Composites
    • /
    • 제27권1호
    • /
    • pp.13-19
    • /
    • 1992
  • In this work, properties of ABS/AES blends were investigated. Blends were prepared by casting from THF. The thermal stability, light resistance, storage modulus and flame retardancy were measured by thermogravimetric analysis, cole. difference in Fade-o-meter, Rheovibron, and limiting oxygen index(LOI). The thermal stability, light resistance and storage modulus increased with increasing contents of AES. ABS and AES showed similar LOI. The LOI of the ABS/AES blends increased with rising contents of AES but all the blends were found to be flammable. It was observed that ABS and AES was incompatible from the morphology by scanning electron microscope(SEM).

  • PDF

중소형화재실험을 이용한 외단열 시스템(EIFS) 화재위험성평가에 관한 연구 (A Study on the Fire Risk Assessment of EIFS by Cone Calorimeter Test & Single Burning Item Test)

  • 민세홍;김미숙
    • 대한안전경영과학회지
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2010
  • Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.

계면활성제를 첨가한 액적의 증발냉각 (Evaporation Cooling of a Droplet containing a Surfactant)

  • 유갑종;방창훈;김현우
    • 대한기계학회논문집B
    • /
    • 제27권4호
    • /
    • pp.424-431
    • /
    • 2003
  • The evaporation cooling phenomenon of a droplet containing a surfactant on a heated surface has been studied experimentally. The two kinds of heater modules made of brass and Teflon$^{TM}$ were tested to investigate the cooling characteristics of droplet. Solutions of water containing Sodium Lauryl Sulfate(0 ppm, 100 ppm, 1000 ppm) were tested in the experiments. The results showed that the contact angle decrease as the concentration of surfactant increases. The tendency did not very with different heated solid materials. As initial temperature of the heated surface becomes high, time averaged heat flux increases and evaporation time decreases with the denser concentration of surfactant. Therefore, water with denser concentration of surfactant could be effective to cool flammable materials. However, the effect of surfactant becomes low as the material temperature is higher than the boiling temperature of water.

지하철 승강장 매점의 화재 시뮬레이션 (The Fire Simulation for the News-stand in the Platform of Subway)

  • 김학범;장용준;이덕희;손윤석;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.2008-2013
    • /
    • 2010
  • 철도 승강장의 매점은 현재 신문판매대, 표준 간이매점, 간이매점(복권방)등의 형태로 운영되고 있다. 따라서 신문이나 잡지등은 쉽게 불에 붙기 때문에 화재의 발화원이 되며, 대구 지하철 화재사고와 마찬가지로 방화의 대상이 될 수 있다. 따라서 지하철 승강장 매점화재 방지를 위하여 매점화재 시뮬레이션 기법 정립이 필요하고 이를 통한 화재방재예측능력이 필요하다. 이에 본 연구에서는 매점화재 시뮬레이션을 수행하였고 수행된 해석결과는 매점지하철 승강장 매점화재 실험결과와 비교 고찰을 통하여 해석의 신뢰도를 검토하였다.

  • PDF

원지의 구조적 변화가 난연제의 정착과 난연 처리된 종이의 인화 특성에 미치는 영향(1) -충전제와 난연 전처리된 폴리에스테르 섬유의 효과 - (Effect of Substrate Structure on Flame Retardant Fixation and Ignition Characteristics of the Treated Paper(1) - Effect of filler and pre treated polyester fiber -)

  • 김병수;이승기;정현채
    • 펄프종이기술
    • /
    • 제34권2호
    • /
    • pp.42-46
    • /
    • 2002
  • Wallpaper has been used for decorating wall with multifarious patterns and colors. Ignition characteristic of wallpapers depends upon the types of wallpapers and their components. Since the wallpaper is made of flammable cellulose fibers diverse materials are being used as flame retardant in producing wallpapers. In this paper the ignition characteristics wallpapers prepared with three different fillers and pretreated polyester fibers were examined. Also the effect of calendering on ignition characteristics was investigated. Commercial papers were used for checking the effect of calendering on the ignition characteristics of treated paper In this experiments, guanidine sulfomate was used as flame retardant.

정전기 방전에 의한 개소린-공기혼합기체의 최소착화에너지에 관한 연구 (The Study about The Minimum Ignition Energy for Electrostatic Discharge in The Gasoline-air Mixture)

  • 황명환;이덕출
    • 한국화재소방학회논문지
    • /
    • 제10권1호
    • /
    • pp.3-9
    • /
    • 1996
  • Electrostatic charge is generated in large scale or high speed processes dealing with materials with large resistance, or under complicated condition. Fire and explosion often occur due to electrostatic charge accumulated in flammable gases, vapor, liquids and powder. It is usually very difficult to verify the cause of accidents as well as the prevention. In this study, it is shown that the needle electrode needs the electrode gap from 1.8mm to 3.8mm, sphere electrode and plate electrodes need the electrode gap of 1.9mmfor the minimum ignition energy. The sphere electrode and the plate electrode requires 12.8mJ and 3.2mJ of minimum ignition energy respectively with the electrode gap of 1.1mm. The ignition voltage rises to very large value as the ground resistance increases.

  • PDF

주 변압기실 화재시나리오에 적용한 미세물분무 노즐의 소화성능 (Performance of Fire Extinguishing of Water Mist Nozzle for Power Transformer Fire Scenario)

  • 이경덕
    • 한국안전학회지
    • /
    • 제21권6호
    • /
    • pp.46-54
    • /
    • 2006
  • Fire extinguishing experiment was conducted with water mist nozzle in case of the pool fire, cascade fire and spray fire on flammable liquid of class B whether water mist system can be effective system for power transformer fire scenario. In the event of a pool fire, flow rate and time to extinguish was inclined to be increased according to the obstruction rate of ignition space. Furthermore, the performance of fire extinguishing depended upon the spraying angle of the nozzles. In case of cascade fire, the effect of extinguishment was began to show from a combustion pan filled with fuel and fuel flowing plate later on.

Terephtalic Acid의 폭발특성에 관한 실험적 연구 (An Experimental Study on Explosion Characteristics of Terephtalic Acid)

  • 오규형;문정기;김한석
    • 한국안전학회지
    • /
    • 제5권1호
    • /
    • pp.41-48
    • /
    • 1990
  • In this study the explosion characteristics of terephtalic acid dust(PTA) was investigated with the Hartmann type apparatus. The minimum ignition energy, minimum explosible concentration, flame propagation velocity, explosion pressure, explosion pressure rise rate and the effect of inert dust(talcum) on explosion characteristics were measured. Flame velocity was 50m/s at 700g/m$^3$ concentration, and the explosion pressure and explosion pressure rise rate were most likely with that of gas explosion. It was found that an inert dust acts as a heat sinker and it disturbs the combustion of flammable dust, as a result, explosion pressure and explosion pressure rise rate were decreased and minimum explosion concentration was increased with increasing the fraction of talcum dust in PTA.

  • PDF

산류(Acids)의 인화점과 최소자연발화온도의 신뢰성 고찰 (Investigation of Reliability of Flash Points and Autoignition Temperatures of Acids)

  • 하동명
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.42-47
    • /
    • 2009
  • The flash point and the AIT(auto-ignition temperature) are the most important combustible properties used to determine the potential for the fire and explosion hazards of flammable material. In order to know the accuracy of data in MSDS(Material Safety Data Sheet), the flash point of n-acids were measured by using Pensky-Martens closed cup tester(ASTM D93), Setaflash closed cup tester(ASTM D3278), Tag open cup tester(ASTM D1310) and Cleveland open cup tester(ASTM D92). Also, the AIT of n-acids were measured by using ASTM E659-78 tester. The measured the flash points and the AIT were compared with literatures and MSDS in KOSHA. The measured the flash points and the AIT were different from those in literatures and MSDS. Therefore, This paper shows that it is needed to investigate the MSDS compatibility of n-acids for the fire safety objectives.