• 제목/요약/키워드: flammable

검색결과 509건 처리시간 0.025초

고주파 스파크에 의한 가연성 혼합가스의 점화위험성에 관한 연구 (A Study on the Ignition Hazard of Flammable Mixtures by Radio-Frequency Spark)

  • 최상원;이관형;문정기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1913-1916
    • /
    • 1996
  • With a progress of electrical and electronic technology, radio-frequency circuits including high frequency components are widely applied to various industrial installations. Some of them are used in hazardous locations where explosive or flammable gases exist. As a result, ignition of such gases may be induced by a spark discharge when the radio frequency circuits are switched on or off. The purpose of this study is to investigate the ignition hazards of acetylene-air and ethylen-air mixtures experimentally based on the IEC 79-3 publication. In this experiment, we used a high frequency resistive circuit which consists of a co-axial cable, a $10{\Omega}$, $20{\Omega}$, $30{\Omega}$, $40{\Omega}$ or $50{\Omega}$ resistor and a power amplifier with frequency range up to almost 1 MHz. Experimental results show that the ignition of the acetylene-air and ethylen-air mixtures due to spark discharge depends primarily on the frequency of the power source in the resistive circuit: the minimum ignition voltage increases gradually with the increase of the frequency.

  • PDF

모사 SNG 연료를 적용한 모델 가스터빈 연소기의 연소 불안정성에 관한 실험적 연구 (An Experimental Study on Combustion Instability in Model Gas Turbine Combustor using Simulated SNG Fuel)

  • 최인찬;이기만
    • 한국연소학회지
    • /
    • 제20권1호
    • /
    • pp.32-42
    • /
    • 2015
  • The combustion instability was experimentally investigated in model gas turbine combustor with dual swirl burner. When such instability occurs, a strong coupling between pressure oscillation and unsteady heat release excites a self-sustained acoustic wave which results in a loud sound, and can even cause fatal damage to the combustor and entire system. In present study, to understand the combustion instability with a premixed mixture, the detailed periods of pressure and heat release data in unstable flame mode were investigated by various measurement methods at relatively rich condition and lean condition near flammable limits. Also, to prepare the utilization of synthetic natural gas (SNG) fuel in gas turbine system, an investigation was conducted using a simulated SNG including methane as a reference fuel to examine the effects of $H_2$ content on flame stability. These results provide that the instability due to flash-back behaviour like CIVB phenomenon occurred at rich condition, while the repetition of relighting and extinction caused the oscillation of lean condition near flammable limit. From the analysis of $H_2$ content effects, it is also confirmed that the instability frequency is proportional to the laminar burning velocity at both rich and lean condition.

Effect of gas composition on dispersion characteristics of blowout gas on offshore platform

  • Yang, Dongdong;Chen, Guoming;Shi, Jihao;Li, Xinhong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권2호
    • /
    • pp.914-922
    • /
    • 2019
  • Gas composition has a significant impact on the dispersion behavior and accumulation characteristics of blowout gas. However, few public studies has investigated the corresponding effect of gas composition. Therefore, this study firstly builds the FLACS-based numerical model about an offshore drilling platform. Then several scenarios by varying the composition of blowout gas are simulated while the scenario with the composition of "Deepwater Horizon" accident is regarded as the benchmark. Furthermore, the effects of the gas composition on the flammable cloud volume, the influenced area of flammable cloud, the influenced area of hydrogen sulfide and the critical time of the hydrogen sulfide spreading to the living area are analyzed. The results demonstrate that gas composition is a driving factor for dispersion characteristics of blowout gas. All the results can give support to reduce the risk of the similar accidents incurred by real blowouts.

원자기여법에 근거한 유기 할로겐 화합물의 순연소열 예측 (Prediction of the Net Heats of Combustion of Organic Halogenated Compounds based on the Atomic Contribution Method)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.7-12
    • /
    • 2003
  • 연소열은 인화성 물질의 화재$.$폭발 위험성을 결정하는 주요한 물성치이다. 할로겐화 유기화합물의 순연소열을 예측하기 위해서, 원자기여법에 기반을 둔 경험식들이 개발되어 왔다. 본 연구에 개발된 경험식을 Cardozo와 Hanley의 경험식들과 비교해 보았다. A.A.D.를 보면 알 수 있듯이 본 연구에서 제안된 경험식으로 계산된 값이 실험값에 가장 근접해 있음을 확인하였다. 따라서, 본 연구에서 제안된 경험식은 여타 할로겐화 유기화합물의 연소열을 예측하는데 도움을 줄 것으로 사료된다.

UL 268 화원에 의한 연기입자의 광학적 특성 (Optical Properties for Smoke Particles of Fire Sources According to UL 268)

  • 지승욱;이종화
    • 한국화재소방학회논문지
    • /
    • 제28권2호
    • /
    • pp.9-13
    • /
    • 2014
  • 본 논문은 화재감지는 물론 화원까지 구별할 수 있는 광전식 연기감지기 개발을 위한 기초 연구이다. 이를 위해, 현재 광전식 연기감지기에 많이 사용되고 있는 광원과 센서를 사용하여 광학챔버를 제작하였으며, UL 268에서 연기감지기를 시험할 때 사용되는 세 가지 화원(종이화원, 목재화원, 인화성 액체화원)을 대상으로 각 화원별 광학적 특징을 구하였다. 그 결과 종이화원과 목재화원은 산란에 큰 차이를 보였으며, 인화성 액체화원은 소광의 원인이 다름을 알 수 있었다.

3D 매트릭스 개질기를 활용한 모사 바이오가스 부분산화 및 수증기 영향 연구 (The Study of Effect of Steam on Partial Oxidation for Model Biogas using 3D Matrix Reformer)

  • 임문섭;전영남
    • 한국수소및신에너지학회논문집
    • /
    • 제22권6호
    • /
    • pp.772-779
    • /
    • 2011
  • New type of syngas generator based on the partial oxidation of biogas in volumetric permeable matrix reformers was suggested as an effective, adaptable and relatively simple way of syngas and hydrogen production for various low-scale applications. The use of biogas as an energy source reduces the chance of possible emission of two greenhouse gases, $CH_4$ and $CO_2$, into the atmosphere at the same time. Its nature of being a reproducible energy source makes its use even more attractive. Parametric screening studies were achieved as air ratio, biogas component ratio, input gas temperature, Steam/Carbon ratio. As the air ratio was low, the production of the hydrogen and carbon monoxide increased in the condition that 3D matrix reformer maintains the stable driving. As it was the simulation biogas in which the carbon dioxide content is high, the flammable range became narrow. And the flammable range was extended if the injected gas was preheated. The stable driving was possible in the low air ratio. The amount of hydrogen production was increased as S/C ratio increased.

출탕유도전극을 이용한 용융물의 출탕방법 및 특성에 대한 연구 (A Study on the Properties and Methods of Electrode System for Tapping of Melts)

  • 문영표;최장영
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.499-503
    • /
    • 2016
  • For safety and economy reasons, hazardous waste including radioactive waste is desired to be converted into stable waste forms with a maximum volume reduction. High temperature melting technology using a plasma torch system can effectively treat even the non-flammable waste as desired. By far, one of the most difficult process for melting the non-flammable waste is a tapping of melts because the melting point of a residual slag in the tapping hole is high and because the viscosity of the melt increases sharply when tapping out. In case of a stationary furnace with a slant tapping port on the side of furnace, a certain amount of melts is left in the tapping hole after tapping out. Because of this, at every end of a melting cycle, the tapping hole needs to be opened by tapping device. The developed tapping device of melts based on both a guide electrode and auxiliary electrode is adequate for the application to discharge of melts except that the consumption of the guide electrode is somewhat faster than expected. Melt is collected in the water cooled vessel.

Influence of Discharge Conditions on the Ignitability of Lycopodium Streams Due to a Single Capacitance Discharge Spark

  • Park, K. S.;M. Yamaguma;T. Kodama;J. H. Joung;Kim, T. Y.;M. Nifuku;M. Takeuchi
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권3호
    • /
    • pp.99-105
    • /
    • 2003
  • The influence of discharge conditions, including the resistance of the sparking circuit, the shape of the electrodes and the width of the falling dust on the ignitability of lycopodium streams were investigated. Discharge characteristics and the ignition phenomena were also explored. When a 100 ㏀ resistor was connected in series with the sparking circuit, the lowest level of minimum ignition energy (MIE) was attained for lycopodium streams. Simultaneously, the area where flammable gas generated increased and the duration of flammable gas generation decreased. That is, the ignita-bility of lycopodium streams depended strongly on the discharge power and discharge duration. Electrodes with sharp tips gave smaller MIEs than those with round tips in a capacitive-inductive sparking circuit, while shape made no difference in a capacitive-resistive circuit. Streams that were too narrow required a considerable amount of energy for ignition.

가연성 이성분계의 최소자연발화온도 거동(MAITB) (Minimum Autoignition Temperature Behavior(MAITB) of the Flammable Binary Systems)

  • 하동명;이성진
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.70-75
    • /
    • 2008
  • The values of the AIT(Autoignition temperature) for fire and explosion protection are normally the lowest reported. The minimum autoignition temperature behavior(MAITB) of flammable liquid mixtures is exhibited when the AIT of mixture is below the AIT of the individual components. The MAITB is an interesting experimental features, which can be significant from the perspective of industrial safety. In this study, the AITs of m-xylene+n-butyric acid and ethylbenzene+n-butanol systems were measured using ASTM E659-78 apparatus. The AITs of m-xylene, n-butyric acid, ethylbenzene and n-butanol which constituted two binary systems were $587^{\circ}C$, $510^{\circ}C$, $475^{\circ}C$ and $340^{\circ}C$ respectively. The m-xylene+n-butyric acid system is exhibited MAITB at 0.3 mole fraction of m-xylene, and its minimum autoignition temperature was $460^{\circ}C$.

송전용 실리콘 폴리머애자의 산불영향 신뢰성 평가( I ) (Reliability Assessment of Forest Fire on Silicone Polymer Insulators in Transmission Lines( I ))

  • 최인혁;이동일;정용운;유근양
    • 한국전기전자재료학회논문지
    • /
    • 제17권11호
    • /
    • pp.1199-1204
    • /
    • 2004
  • Most overhead transmission lines in Korea run over the mountain; however, only little study has been made for the effect of mountain fire on polymeric insulator for transmission lines, though the study is significantly required, Therefore, in this study, the authors observed the deformation of the sheds of the insulator under fire, varying the ignition time using artificial ignition testing equipment, and investigated electrical and mechanical characteristics of the insulator through dry withstand voltage test, impulse flashover test and tensile load test. As the results of the tests, the following conclusions were obtained, First, when the insulator was subjected to the fire, the electrical characteristics were slightly reduced, but there was no change on the mechanical characteristics, Secondly, the sheds and sheath of the insulator were not non-flammable but less-flammable. These two results show the high mechanical stability and durability of the insulator under severe fire condition, though the electrical characteristics can be deteriorated as the time that the insulator is subjected to fire, goes by.