• Title/Summary/Keyword: flame retardant cotton fabrics

Search Result 17, Processing Time 0.023 seconds

Effect of Fixation Methods on the Flame Retardant and Performance Properties of MDPPA/HMM treated Cotton (MDPPA/HMM처리 면직물의 고착방법에 따른 방염성과 물성의 변화)

  • 지주원;오경화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2000
  • Effect of fixation methods on the flame retardant(FR) and performance properties of MDPPA/HMM treated cotton fabrics were studied. Combination of three different fixation methods - premercerization, swelling agent treatment, pad dry cure fixation, and wet fixation - were applied to flame retardant finish of cotton with MDPPA/HMM. As a result, an increase in internal volume of cotton fiber by pre-mercerization and addition of swelling agent, and wet fixation increased %add-on of FR agent improving FR efficiency and wash fastness. Tensile strength of MDPPA/HMM treated cotton fabrics by wet fixation and swelling agent were slightly decreased, but that of premercerized cotton was improved. Wet fixated fabric showed lower bending rigidity and better compressional properties which improved fabric hand. Retention of swelling ability of cotton treated with MDPPA/HMM improved moisture absorption properties.

  • PDF

Study on the Physical Properties and Flame Retardancy of Tencel FR/Cotton Complex Knit Fabrics (Tencel FR/Cotton 복합원단의 물리적 특성 및 난연성에 관한 연구)

  • Kim, Hyun-Ah;Kim, Hyun-Chel
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.7
    • /
    • pp.703-713
    • /
    • 2012
  • This study analyzed the physical properties and flame retardancy of Tencel FR/Cotton complex knit fabrics in order to satisfy two aspects of eco-friendliness and functionality. The flame retardant (FR) treatment of complex knit fabrics was applied by a pad-dry-cure method for additional functionality. Tensile strength, extension, bursting strength, LOI, and flame retardancy were measured by the KS (Korean Standard) K manual. The hand value knit fabrics were measured by KES-FB system. Subsequently, tensile strength and extension of wale and tensile strength of course increased in tandem with the Tencel FR yarn content. Tencel FR/Cotton complex knit fabrics were suitable for summer-weight and for baby clothes through the KES-FB system measurements. The bursting strength of Tencel FR/Cotton complex knit fabrics decreased as the contents of the Tencel FR increased; in addition, LOI increased as the contents of Tencel FR increased. This was due to the Tencel FR flame resistance function; however, the tensile strength decreased. The optimum fiber content of Tencel FR/cotton content was 1:1. The optimum conditions of flame retardant treatment were a treatment temperature $130^{\circ}C$ and the concentration of finishing agent and assistance binder (AR4260) was 35% and 1%, respectively.

Changes of Flame Retardant and Physical Properties of Cotton Knitted Fabrics after Flame Resistant Treatment (면편성물의 방염처리에 의한 방염성과 물성변화)

  • Jee, Ju-Won;Song, Kyung-Geun
    • Fashion & Textile Research Journal
    • /
    • v.5 no.3
    • /
    • pp.273-282
    • /
    • 2003
  • Effect of fixation methods and relaxation treatment on the flame retardant(FR) and physical properties of MDPP/HMM treated cotton weft-knitted fabrics were studied. Combination of four different fixation methods - relaxation, swelling agent treatment, pad dry cure fixation, and wet fixation - were applied to flame retardant finish of cotton weft-knitted fabric with MDPP/HMM. As the results, 1. Swelling agent and wet fixation method helps FR agent penetrate the fiber efficiently. Interlock showed relatively higher values of LOI than single jersey. 2. Interlock showed relatively higher values of bending rigidity(B), shear rigidity(G) and coefficient of friction(MIU) than those of single jersey before and after flame resistant treatment. 3. An increase in internal volume of cotton fiber by relaxation treatment increased the bending rigidity(B), shear rigidity(G) and compressional energy(WC). 4. The cotton weft-knitted fabric treated wet fixation, which crossliked FR agent efficiently, showed higher bending rigidity, shear rigidity(G) and lower compressional energy(WC). Retention of swelling ability of cotton weft-knitted fabrics treated with MDPP/HMM, which increased the internal volume of cotton weft-knitted fabric, showed lower bending rigidity.

Flame Retardancy of Cellulose Fabrics Treated with 3-(Hydroxyphenyl Phosphinyl) Propanoic Acid

  • Zhang, Lianping;Kim, Sam-Soo;Lee, Jae-Woong
    • Textile Coloration and Finishing
    • /
    • v.20 no.5
    • /
    • pp.1-6
    • /
    • 2008
  • 3-(Hydroxyphenyl phosphinyl) propanoic acid (HPPA) has been one of the most commonly used durable flame retardant agents for polyethylene terephthalate (PET) for many years. We intended to explore the application of HPPA to cellulose fabrics as formaldehyde-free phosphorus based flame retardants (FRs) through green chemistry process. The flame retardancy of the flame-retardant treated cellulose fabrics were characterized by using inductively coupled plasma spectroscopy (ICP) and limiting oxygen index (LOI). Structural changes of the treated cellulose fabrics were carried out by thermogravimetric analysis (TGA) and Fourier transform infrared (FT-IR) spectroscopy. To enhance the flame retardancy of HPPA treated cellulose fibers, glycerol polyglycidyl ether (GPE), a crosslinking agent was employed. Both HPPA and GPE treated cotton fabric imparted an LOI value over 26.

Inflammability Characteristics and Wear Comfort Property of Modacrylic Composite Yarn and Knitted Fabrics (난연 모다크릴 복합 방적사 니트소재의 방염성과 착용쾌적특성)

  • Kim, Hyunah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.42 no.3
    • /
    • pp.397-410
    • /
    • 2018
  • This study investigated the flame retardant, anti-static property and wear comfort of knitted fabrics made of two kinds of composite yarns comprised of modacryl, antistatic PET, cotton and excel(R) fibers. A Low Oxygen Index (LOI) above 28 was observed in the modacryl knitted fabric specimens. The flame retardant was superior at the excel(R) fiber (including modacryl knitted fabric) than the one including cotton fiber. Anti-static properties of the modacryl knitted fabrics imbedded by 3wt% of antistatic PET fibers were observed by rubbing with wool fabric attached to the measuring apparatus, which showed a better anti-static property than the excel(R) fiber (including modacryl knitted fabric). Wear comfort indicated that quick perspiration absorption and the fast dry property of excel(R) (including modacryl knitted fabric) was better than one that included cotton fiber. Warmth keepability and breathability of the knitted fabrics indicated good results in the excel(R) (including cotton and the modacryl knitted fabrics). However, the tactile hand property of cotton fiber (including modacryl knitted fabric) was better than excel(R) fiber due to high extensibility and compressibility, and low bending and shear rigidity of the cotton fiber (including modacryl knitted fabrics).

Flame-retardant Finish of Cotton Fabrics Using UV-curable Phosphorous-containing Monomers (자외선 경화형 인계 단량체를 이용한 면직물의 방염가공)

  • Jang, Jin-Ho;Jeong, Yong-Kyun
    • Textile Coloration and Finishing
    • /
    • v.20 no.4
    • /
    • pp.8-14
    • /
    • 2008
  • Flame-retardant cotton fabrics were prepared by UV curing of photocurable aqueous formulations of phosphorous-containing methacrylate monomers and 2-hydroxy-2-methyl-1-phenyl-1-propanone as flame retardants and a photoinitiator respectively, which is an environmentally friendly and energy-saving process. The characterization of the UV-coated cotton fabric was made by ATR, TGA and limited oxygen index measurement. UV cured coating onto cotton fabrics reduced the first thermal decomposition temperature and mass loss as well as increase in the amount of char residue compared with the untreated cotton fabric presumably due to modified thermal decomposition process. The LOI values up to 28.5 and 27.2 were obtained by the UV curing of MMEP and TMEP respectively. The treatment was durable to five laundering cycles, which was more prominent in the case of trifunctional TMEP treatment.

Formaldehyde-Free Durable Flame-Retardant Finish of Cotton Using Hexachlorocyclophosphazene and Triethanolamine (Hexachlorocyclophosphazene과 Triethanolamine을 이용한 면섬유의 포름알데히드-프리 내구성 방염가공)

  • Kim, Jeong-Hwan;Jang, Jinho
    • Textile Coloration and Finishing
    • /
    • v.32 no.3
    • /
    • pp.150-157
    • /
    • 2020
  • Hexachloro-cyclophosphazene(HCCP), a formaldehyde-free flame retardant (FR), was steam-cured with triethanol amine(TEA) to impart durable flame-retardancy to cotton fabrics. While the HCCP treatment alone showed very limited resistance to repeated laundering cycles, the addition of TEA substantially improved the laundering durability of the FR cotton up to twenty laundering cycles. The extended washing resistance was accomplished by the increased nucleophilic substitution of unreacted P-Cl groups in HCCP by the TEA resulting in the more densely crosslinked FR networks. With increasing molar ratio of TEA to the HCCP up to 2, the flame retarding effectivity and the synergistic effectiveness improved to 2.8 and 1.8 respectively. TGA and microscale combustion calorimetry verified the pyrolysis and combustion behaviors of the FR-cotton, which showed lower maximum pyrolysis and combustion temperatures together with substantially decreased peak pyrolysis and heat release rate, synergistically yielding larger amounts of carbonaceous chars. The formaldehyde-free HCCP and TEA can be a durable FR finishing agents for cotton fabrics acting through a solid-phase flame-retarding mechanism.

Formaldehyde-Free Durable Flame-Retardant Finish of Cotton Fabrics Using Vinyl Bisphosphonic Acid and Acrylamide (비닐이포스폰산과 아크릴아미드를 이용한 면직물의 포름알데히드-프리 내구성 방염가공)

  • Jang, Mi-Ji;Jang, Jinho
    • Textile Coloration and Finishing
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • The durable FR treatments such Pyrovatex and Proban have been used for cotton fibers, while the finishes involve toxic ammonia or formaldehyde release during finishing process or finished products. In this study, ecofriendly flame-retardant treatment of cotton fabrics was carried out using UV-curable formulations of Vinyl bisphosphonic acid (VBPA), Acrylaminide and Triacryloylhexahydro-1,3,5-triazine, as a monomer, a comonomer and a cross-linking agent respectively, which can introduce a cross-linked copolymer networks. With an optimal finish formulation, the flame retardancy of LOI 29.8 was maintained even after 10 laundering cycles. In TGA analysis, the DTGA peak decreased from 389℃ to 252℃ and the amount of char yield increased from 6.1% to 46.1% compared to the untreated cotton. In addition, MCC analysis showed that Peak HR and THR decreased by 59.4% and 69.2% respectively, compared to the untreated cotton. The pyrolysis and combustion behaviors of the FR-treated cotton implied a condensed-phase flame-retarding mechanism.

Durable Flame-Retardant Finish of Cotton Fabrics Using a Water-soluble Cyclophosphazene Derivative (수용해성 사이클로포스파젠 유도체를 이용한 면섬유의 내구성 방염가공)

  • Kim, Jeong-Hwan;Jang, Jinho
    • Textile Coloration and Finishing
    • /
    • v.33 no.2
    • /
    • pp.64-71
    • /
    • 2021
  • Large amount of formaldehyde could be released inevitably during the flame-retardant (FR) treatments or from the finished fabrics using Provatex reagent and Proban polymers which have been used as durable FRs for cotton. A water-soluble cyclophosphazene derivative was synthesized as an ecofriendly phosphorus-based FR for cotton fibers. Dichloro tetrakis{N-[3-(Dimethylamino)propyl]methacrylamido} cyclcophosphazene (DCTDCP) was synthesized through the substiutution reaction of Hexachloro cyclophosphazene and N-[3-(Dimethylamino)propyl] methacrylamide at a mole ratio of 1 : 4, which can be cured dually by both alkaline treatment and UV irradiation. More crosslinked networks were produced through the addition of Triacryloyl hexahydrotriazine and Acrylamide as a UV-curable crosslinker and a comonomer respectively. Both flame retardancy and washing durability of the FR cotton were improved synergistically. The durability improvement may be caused by the covalent bond formation of the FR with cellulose and the high degree of polymerization of DCTDCP, which can be verified by the pyrolysis and combustion behaviors analyzed by LOI, TGA, and microcalorimeter.

The Synthesis of Diphenyl ethanolamidophosphate (DPEAP) and the Flame Retardancy of Cotton Fabric (Diphenyl ethanolamidophosphate의 합성과 면섬유에 대한 방염성)

  • Huh, Man Woo;Yoon, Jong Ho;Cho, Yong Suk;Kim, Young Suk;Lim, Hak Sang
    • Textile Coloration and Finishing
    • /
    • v.8 no.2
    • /
    • pp.25-34
    • /
    • 1996
  • Diphenyl ethanolamidophosphate(DPEAD) was synthesized for the purpose of developing a new flame retardant for cotton fabric. As the intermediate material was used diphenyl chlorophosphate(DPCP) and it was synthesized by using phosphorus oxychloride and phenol as the starting materials. The final product DPEAP was obtained by the reaction of DPCP and ethanolamine. The flame retardancy of cotton fabrics treated by DPEAP through pad-dry-cure(PDC) process was examined at various conditions. The physical property change of the DPEAP treated cotton fabrics were investigated by examining the drape stiffness, the wrinkle recovery, and the tensile strength. The results are summarized as follows: (1) DPEAP has shown excellent flame retardancy on cotton fabrics in comparison to other flame retardants for cotton fabrics available commercially. (2) The optimal condition for PDC process found was that the curing temperature was 16$0^{\circ}C$, the DPEAP concentration was 10%, the catalyst $({NH_{4})_{2}HPO_{4}$ concentration was 7.0%, and the fixing agent hexamethylol melamine (HMM)/DPEAP weight ratio was 1/8. (3) The wrinkle recovery of the processed fabrics increased with increasing DPEAP concentration. (4) The drape stiffness of the cotton fabrics treated by DPEAP have shown essentially no change until increasing DPEAP concentration to 15 %, however DPEAP concentration exceeds 20% the drape stiffness increased drastically with increasing DPEAP concentration. When DPEAP concentration is kept constant the drape stiffness increased with increasing $({NH_{4})_{2}HPO_{4}$ concentration and HMM/DPEAP weight ratio. (5) The tensile strength of the processed fabrics was lower than that of untreated fabrics, but the tensile strength retention increased with increasing DPEAP concentration.

  • PDF