• 제목/요약/키워드: fixed-length analysis

검색결과 308건 처리시간 0.03초

경인항 인천컨테이너터미널의 최적 부두길이 산정에 관한 연구 (A Study on the Assessment of Optimum Berth Length for Incheon Container Terminal of the Kyeong-In Port)

  • 김세원;박영수;김태민
    • 수산해양교육연구
    • /
    • 제23권2호
    • /
    • pp.210-220
    • /
    • 2011
  • The Keyongin Inland waterway will connect with Han-River and the Northen part of the Incheon-seaway and this way will be opened at the early of October this year. In this regard, the Incheon container terminal is under constructing for 1,000 TEU & 550 TEU container vessels at the place of leftside of the Seohae lockgate. However the terminal length is not still fixed due to at a great expenses of construction and dosposal matter of the dredged soil. So this paper will suggest the optimum berth length by using the full mission shiphandling simulator for berthing and unberthing shipmaneuvering. And also evaluates the design standard of harbor construction rules and analysis optimum berth length against ship's length for safe shiphandling at terminals in accordance with the customary practices of the major ports in Korea.

External apical root resorption 6 months after initiation of orthodontic treatment: A randomized clinical trial comparing fixed appliances and orthodontic aligners

  • Toyokawa-Sperandio, Katia Cristina;Conti, Ana Claudia de Castro Ferreira;Fernandes, Thais Maria Freire;de Almeida-Pedrin, Renata Rodrigues;de Almeida, Marcio Rodrigues;Oltramari, Paula Vanessa Pedron
    • 대한치과교정학회지
    • /
    • 제51권5호
    • /
    • pp.329-336
    • /
    • 2021
  • Objective: To compare the magnitude of external apical root resorption (EARR) 6 months after starting orthodontic treatment using orthodontic aligners (OAs) and fixed appliances (FAs). Methods: This parallel randomized clinical trial included 40 patients randomized into two groups: OA group (n = 20, 160 incisors) and FA group (n = 20, 160 incisors). For evaluation of the tooth length, periapical radiographs and standardized linear measurements of the maxillary and mandibular incisors were acquired before (T0) and 6 months after treatment initiation (T1). EARR was calculated through the difference in length between the two time points (T1-T0). Statistical comparisons were performed by means of using t-tests, chi-squared test and covariance analysis (a = 5%). Results: Rounding of the root apex was observed in both groups; the resorption involved 2.88% of the root length, so 97.12% of the tooth length remained intact. Intragroup comparisons between the two time points revealed a significant difference, with (T1-T0) ranging from -0.52 to -0.88 mm in the FA group and from -0.52 to -0.85 mm in the OA group. In the intergroup comparisons, only tooth #21 presented a statistically significant difference (OA: -0.52 ± 0.57 mm, FA: -0.86 ± 0.60 mm); however, the overall differences between groups were not clinically relevant, ranging from 0.03 to 0.35 mm. Conclusions: OA and FA treatment resulted in a similar degree of EARR in the maxillary and mandibular incisors at 6 months after treatment initiation. However, the amount of resorption was small and does not impair tooth longevity.

지방공사 의료원의 수익성 관련요인 분석 (Analysis on the Relating Factors of Profitability of Korean Public Corporation Medical Centers(KPCMCs))

  • 문재우;박재산
    • 한국병원경영학회지
    • /
    • 제9권2호
    • /
    • pp.102-127
    • /
    • 2004
  • The objective of this study is to analyze a current trend of and relating factors on profitability of the Korean Public Corporation Medical Centers(KPCMCs, hereinafter, hospitals) in Korea. There are 34 hospitals in Korea as of 2004. Among these hospitals some are red ink hospitals, others are black inks in terms of profitability. Data were collected by Korea Health Industry Development Institute(KHIDI) Statistics for Hospital Management 2000-2002 and Ministry of Health and Welfare(MOHW) financial data of public hospitals which was planned to coordinate public health care services roadmap in the long run. The samples are 32 hospitals. Profitability was measured in the aspect of profit rate with normal profit to total assets, and normal profit to gross revenues as dependent variables in respective. Independent variables were classified by general factors, i.e., location, intern/resident training, period of opening, number of beds, and managerial factors(current ratio, fixed ratio, liability to total assets, total assets turnover, personnel costs, materials cost, administrative cost), and finally factors related to patient treatment(average length of stay, bed occupancy rate, admission ratio of outpatients). The methods of analysis are correlation and multiple regression analysis. This study shows firstly, a lot of hospitals are optimal current ratio. Hospitals in upper 100% current ratio are 81.2%. And the personnel cost in total costs are high. Secondly, the trend of normal profit to gross revenues of hospitals are deteriorating gradually. And lastly, as a result of multiple regression analysis, the factors had on significant effect on normal profit to total assets are fixed ratio(+), liability to total assets(-), bed occupancy rate(+), admissions of outpatients(+), etc. And the factors had on significant effect on normal profit to gross revenues are current ration(+), fixed ratio(+), personnel cost(-), administrative expenses(-), admissions of outpatients(+), etc. In conclusion, to improve the profitability of hospitals, the efforts to reduce personnel cost and average length of stay might be needed. And also beds utilization rate need to be increased.

  • PDF

한강유역 동시강우량 자료를 이용한 강우량-거리비의 산정 (Estimation of Depth-Length Ratios with the Han-River Basin's Simultaneous Rainfall Data)

  • 이원환;이길춘
    • 물과 미래
    • /
    • 제20권1호
    • /
    • pp.55-61
    • /
    • 1987
  • 본 연구는 한강 유역의 고정된 지점 동시 강우자료의 빈도해석에 의하여 우량-거리비를 산정한 것이다. 우량- 거리비는 한강유역강우의 시공간상관구조를 파악하는데 근거를 제공한다. 우량-거리비는 거리증가에 따라 감소하고 강우 지속시간 증가에 따라 증가하며 재현기간 증가에 따라 약간 감소함을 나타내고 있다. 한강유역의 강우의 특성식을 특성계수와 함께 제시하였다.

  • PDF

국내에서 제작된 고정성 보철물의 수명과 실패 요인 및 양상 (LONGEVITY AND FAILURE ANALYSIS OF FIXED RESTORATIONS SERVICED IN KOREA)

  • 신우진;전영식;이근우;이호용;한동후
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.158-175
    • /
    • 2005
  • Statement of problem. Every effort has been continually made to obtain objectivity in measuring the longevity of fixed restorations, such as by establishing unified judgement standard for deciding success and adopting statistical method that analyzes the data of successful and failed cases at the same time. In Korea, however desired level of development has not to be made in this field yet. Purpose. This study, adopting California Dental Association (CDA) quality evaluation system, established objective standard for deciding success, and inferred the longevity of fixed restorations and their failure analysis through adopting Kaplan-Meier survival analysis. Material and method. In order to assess the longevity of flxed restorations serviced in Korea and causes of failure, a total of 1109 individuals (aged 15-74, 716 women and 393 men loaded with 2551 unit fixed restorations, and 1934 abutments) who lived in Kyung-In Province were examined and the findings were as follows : Results. 1. Length of service of fixed restorations serviced in Korea was 6.86$\pm$0.15 yr (mean), 5.5 yr (median), and the rate of success was 65.82% in 5 year survival, and 21.15% in 10 year survival. 2. When there was patient's need for replacing old prosthetics, longevity of fixed restorations was 7.51$\pm$0.27 yr (mean), 7 yr (median), and the rate of success was 61.08% in 5 year survival, and 17.57% in 10 year survival. 3. Longevity of fixed restorations was longest in the over-sixty age group(9.21$\pm$0.66) and that of the teen age group(3.39$\pm$0.28) was shortest (p<0.05). 4. Longevity of fixed restorations of women (7.38$\pm$0.18 years) was longer than that of men (6.00$\pm$0.26) (p<0.05). 5. As for the provider factor (such as unlicensed performers, university hospitals, and private clinic), there was no statistically significant difference in longevity of fixed restorations. 6. Defective margin (34.78%). periodontal disease (12.15%), periapical involvement (11.73%), was the most frequent causes of failure and poor esthetics group showed the longest life above all (p<0.05). Actual frequent causes of failure after removing old prosthetics were defective margin, periapical involvement, periodontal disease and uncemented restoration. In 75.67% of the cases, abutment state after removing old prosthetics was good enough for loading another prosthetics. 7. There was found to have statistically significant influence between longevity of single crown (6.35$\pm$0.20 yr) and that of 3 unit fixed restorations (7.60$\pm$0.30 y) (p<0.05). In each case the most frequent cause of failure was defective margin. 8. The number of cantilever pontic, pontic/abutment ratio, oral hygiene status were found to have no statistically significant influence on longevity of fixed restorations in all groups (p>0.05). 9. Longevity of fixed restorations made of non precious metal was longest (9.60$\pm$0.40 yr) semi precious and precious trailing behind(p<0.05). 10. Group function group (37.04%) and partial group function group (44.62%) were predominant in frequency but showed no correlation between them and among different types of occlusal plane and different types of occlusal surface (p>0.05). 11. Longevity of fixed restorations was longest in the centric interference group(9.35$\pm$0.62) (p<0.05) among different types of occlusal interference. Conclusion. We found that longevity of fixed restorations serviced in Korea is affected by age, gender and type of material, and that most frequent cause of failure is defective margin. In order to assess the accurate longevity of axed restorations, unified research design. overcoming inter-observer difference and establishing the objective research items are needed. Furthermore, it is thought that prospective approach through thorough study and regular follow-ups is needed just from the start of research. Nationwide detailed studies on length of service of fixed restorations manufactured in Korea are hoped to be conducted hereafter.

Does matching relation exist between the length and the tilting angle of terminal implants in the all-on-four protocol? stress distributions by 3D finite element analysis

  • Li, Xiaomei;Cao, Zhizhong;Qiu, Xiaoqian;Tang, Zhen;Gong, Lulu;Wang, Dalin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.240-248
    • /
    • 2015
  • PURPOSE. To explore whether there is matching relation between the length and the tilting angle of terminal implants in the All-on-Four protocol by studying the effects of different implant configurations on stress distributions of implant, bone, and framework. MATERIALS AND METHODS. Four implants were employed to support a full-arch fixed prosthesis and five three-dimensional finite element models were established with CT images, based on the length (S and L) and distal tilt angle ($0^{\circ}$, $30^{\circ}$ and $45^{\circ}$) of terminal implants for an edentulous mandible, which named: Tilt0-S, Tilt30-S, Tilt30-L, Tilt45-S and Tilt45-L. An oblique 240 N was loaded at second molar. The von Mises Stresses were analyzed. The implants were consecutively named #1 to #4 from the loading point. RESULTS. 1) Tilt0-S had the greatest stress on the implants, with the other groups exhibiting variable reductions; the four implants of Tilt45-L demonstrated the greatest reduction in stress. 2) Tilt0-S had the greatest stress at bone around #1 implant neck, and Tilt45-L exhibited the least stress, which was a 36.3% reduction compared to Tilt0-S. 3) The greatest stress in the framework was found on the cantilevers distal to #1 implant. Tilt45-S exhibited the least stress. CONCLUSION. Matching different length and tilting angle of the terminal implants led to variable stress reductions on implants, bone and the superstructure. By optimizing implant configuration, the reduction of stress on implants and surrounding bone could be maximized. Under the present condition, Tilt45-L was the preferred configuration. Further clinical testings are required.

CBR과 버스티 트래픽원이 가해진 ATM 다중화기의 성능 분석 (Performance Analysis of an ATM Multiplexer Loaded by CBR and Bursty Traffic Sources)

  • 김승환;박진수
    • 한국통신학회논문지
    • /
    • 제19권4호
    • /
    • pp.633-638
    • /
    • 1994
  • 고정 길이의 패킷 전송 구조로 이루어진 ATM은 B-ISDN을 실현할 수 있는 방식으로 주목되고 있으며, 패킷 길이가 고정되어 있기 때문에 사용자에게 다양한 서비스의 제공의 가능할 수 있다. 본 논문에서는 CBR 트래픽과 버스티 트래픽의 두가지 트래픽원이 유한 크기의 버퍼를 갖는 ATM 다중화기에 가해진 경우의 큐잉 시스템을 분석한다. 다중화기의 성능 측정을 위한 간단하고 반복적인 셀 손실률의 계산식을 유도하고 수치 계산 예를 통해 셀 손실률의 특성을 검토한다. 이러한 연구의 결과들은 ATM 다중화 시스템의 버퍼 설정에 관한 문제와 성능 분석에 도움이 될 수 있을 것이다.

  • PDF

Modeling and Analyzing Per-flow Throughput in IEEE 802.11 Multi-hop Ad Hoc Networks

  • Lei, Lei;Zhao, Xinru;Cai, Shengsuo;Song, Xiaoqin;Zhang, Ting
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권10호
    • /
    • pp.4825-4847
    • /
    • 2016
  • In this paper, we focus on the per-flow throughput analysis of IEEE 802.11 multi-hop ad hoc networks. The importance of an accurate saturation throughput model lies in establishing the theoretical foundation for effective protocol performance improvements. We argue that the challenge in modeling the per-flow throughput in IEEE 802.11 multi-hop ad hoc networks lies in the analysis of the freezing process and probability of collisions. We first classify collisions occurring in the whole transmission process into instantaneous collisions and persistent collisions. Then we present a four-dimensional Markov chain model based on the notion of the fixed length channel slot to model the Binary Exponential Backoff (BEB) algorithm performed by a tagged node. We further adopt a continuous time Markov model to analyze the freezing process. Through an iterative way, we derive the per-flow throughput of the network. Finally, we validate the accuracy of our model by comparing the analytical results with that obtained by simulations.

미분변환법을 이용한 다중 크랙을 갖는 비균일 나노빔의 진동해석 (Vibration Analysis of Multi Cracked Nonuniform Nanobeam by using Differential Transformation Method)

  • 신영재;박성현;김진홍;유영찬
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권5호
    • /
    • pp.93-101
    • /
    • 2016
  • 본 연구에서는 비국지 탄성이론과 미분변환법을 이용하여 탄성매질속 다중 크랙을 가진 비균질 나노빔의 지배방정식을 유도하고, 유도된 지배방정식과 경계조건에 미분변환법을 적용하여 나노빔의 축방향의 진동해석을 하며, 나노빔의 첫단과 끝단의 경계조건이 각각 고정단(Clamped end)과 자유단(Free end)의 경우에 대하여 수치해석을 수행하였다. 수치해석 결과를 기존 연구결과와 비교하여 타당성을 입증한 후, 비국지 작은 척도효과 (Nonlocal small scale effect), 탄성매질의 강성, 크랙의 위치, 크랙의 강성 그리고 비국지 탄성이론의 나노빔에 대한 진동해석 결과를 고찰하였다.

현장인발시험을 통한 제거식 쏘일네일의 거동특성 평가 (Evaluation of Behavior Characteristics of Removable Soil Nails from the Field Pull-Out Tests)

  • 김홍택;강인규;이대형;정성필;박시삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.137-144
    • /
    • 1999
  • Recently a removable soil nail is demanded due to problems beyond of economical and engineering purpose. In this study removable soil nails are developed and field pull-out tests are carried out 16 times in order to analysis pull-out characteristics of the removable soil nail. For the spacing and the installed position of fixed socket, the length of the soil nail, and W/C ratio of cement grout in the removable soil nail, pull-out characteristics of pull-out tests are analyzed. From the pull-out characteristics of removable soil nails, it is found that the spacing of fixed socket and W/C ratio of cement grout are important design parameters.