• 제목/요약/키워드: fixed-intensity

검색결과 327건 처리시간 0.033초

유도 결합 플라즈마를 이용한 TiN 박막의 식각 특성 (Etch Characteristics of TiN Thin Films in the Inductively Coupled Plasma System)

  • 엄두승;강찬민;양성;김동표;김창일
    • 한국표면공학회지
    • /
    • 제41권3호
    • /
    • pp.83-87
    • /
    • 2008
  • This study described the effects of RF power, DC bias voltage, chamber pressure and gas mixing ratio on the etch rates of TiN thin film and selectivity of TiN thin film to $SiO_2$ with $BCl_3$/Ar gas mixture. When the gas mixing ratio was $BCl_3$(20%)/Ar(80%) with other conditions were fixed, the maximum etch rate of TiN thin film was 170.6 nm/min. When the DC bias voltage increased from -50 V to -200 V, the etch rate of TiN thin film increased from 15 nm/min to 452 nm/min. As the RF power increased and chamber pressure decreased, the etch rate of TiN thin film showed an increasing tendency. When the gas mixing ratio was $BCl_3$(20%)/Ar(80%) under others conditions were fixed, the intensity of optical emission spectra from radical or ion such as Ar(750.4 nm), $Cl^+$(481.9 nm) and $Cl^{2+}$(460.8 nm) was highest. The TiN thin film was effectively removed by the chemically assisted physical etching in $BCl_3$/Ar ICP plasma.

Changes of superoxide dismutase and glutathione peroxidase in light damaged rat retina

  • Kaidzu, Sachiko;Tanito, Masaki;Takanashi, Taiji;Ohira, Akihiro
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.430-432
    • /
    • 2002
  • The changes in expression of copper-zinc superoxide dismutase (CuZn-SOD), manganese superoxide dismutase (Mn-SOD) and glutathione peroxidase (GPX) in light-damaged rat retinas were examined. Sprague-Dawley rats (male, 6-weeks-old) were maintained on a cyclic photoperiod (12 hours light and 12 hours darkness) for 2 weeks. The illumination intensity during the light period was 80 lux. To induce light damage to the retina, a high-intensity illumination (3000-lux) was applied to the animals for 24 hours. After light exposure, the animals were returned to cyclic lighting. Eyes were enucleated 12 and 24 hours after light exposure started or 1,3, and 7 days after light exposure ended. Eyes were fixed and embedded in paraffin wax. Tissues were cut into 4${\mu}{\textrm}{m}$-thick sections. Sections were immunostained using antibody against CuZn-SOD, Mn-SOD, GPX and 8-hydroxy-deoxyguanocine (8-OHdG) as oxidative stress marker. 8-OHdG was observed in the outer nuclear layer (ONL) and retinal pigment epithelium (RPE) during light exposure. In light-damaged retinas CuZn-SOD labeling was up regulated in the ONL and RPE. Mn-SOD labeling was up regulated in rod inner segments (RIS) during light exposure and that in the RPE was up regulated after exposure. GPX labeling was observed in rod outer segments (ROS) during light exposure. GPX labeling was also observed in the RPE during and after light exposure. All three enzymes were observed in the outer retina, which suffered light damage, but occurred in defferent layers except within the RPE, in which case all three were expressed. These enzymes may play complementary roles as protective factors in light-damaged retinas.

  • PDF

피치 기반 사운드-컬러이미지 변환에 관한 기초연구 (A Basic Study on the Pitch-based Sound into Color Image Conversion)

  • 강건우;김성일
    • 감성과학
    • /
    • 제15권2호
    • /
    • pp.231-238
    • /
    • 2012
  • 본 연구는 하나의 감각으로 인해 다른 영역의 감각을 불러일으키는 공감각 현상을 기초로 하여 사운드에서 컬러이미지를 유추하여 생성하는 응용 시스템의 구현을 최종 목표로 한다. 이를 위해 사운드의 특징정보인 기본주파수(F0, Fundamental Frequency)에서 음계(Scale) 및 옥타브(Octave) 성분을 추출한 후, HSI 컬러모델인 색상(Hue), 명도(Intensity) 성분에 각각 매핑한다. 본 논문에서 채도(saturation)값은 고정된 값을 사용한다. 이를 다시 RGB 컬러모델로 변환한 후 최종 BMP 포맷으로 컬러 이미지를 출력한다. 본 연구에서 제시한 사운드-컬러이미지 변환 방법을 토대로 기본 변환 시스템을 구현해 본 결과, 기본주파수에서 추출된 음계 및 옥타브 성분의 변화에 따라 색상 및 명도가 상이한 다양한 컬러가 나오는 것을 확인할 수 있었다. 또한 하드웨어적 구현을 위해 TMS320C6713 DSP Board에 포팅하여 실험한 결과 제안된 시스템의 시뮬레이션 결과와 동일한 컬러 이미지가 출력됨을 확인하였다.

  • PDF

평면 난류 오프셋 제트에 관한 연구 (A Study on the Plane Turbulent Offset Jet)

  • 유정열;강신형;채승기;좌성훈
    • 대한기계학회논문집
    • /
    • 제10권3호
    • /
    • pp.357-366
    • /
    • 1986
  • 본 연구에서는 3공피토우관 및 열선유속계를 사용하여 벽에 평행한 2차원 난류제트의 난류량들을 측정하였고, 스캐니 밸브를 이용하여 벽면아력분포를 측정함 으로써 재순환 영역을 포함한 전체유동장에서의 유동특성을 고찰하였다. 또한 잘 알려진 표준 k-.epsilon. 난류모형 및 유선곡률을 고려한 수정된 k-.epsilon. 난류모형을 이용하여 측정 수치해석을 수행하였다.

이중동축 메탄/공기 층류 부분 예혼합화염에서의 화염구조와 자발광 배출 특성;안쪽관 연료주입의 영향 (Flame Structure and Light Emission Characteristics in Coaxial Laminar Partially Premixed $CH_{4}/Air$ Flames;Effect of Central Fuel Injection)

  • 오정석;정용기;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1116-1121
    • /
    • 2004
  • In this study, the effect of central fuel injection on a coaxial laminar $CH_{4}/air$ flame was experimented at the defined premixing condition(${\Phi}=1.90$, ${\sigma}=50/75/100%$, x/D=10). The partial premixing parameter are the equivalence ratio that total fuel is fixed at 200cc/min, the fuel split degree which means the percentage of fuel entering the outer tube to the total amount, and the mixing distance indicating the nonreactant mixture's homogeneity between inner tube top and burner exit. The object is to investigate the flame structure and chemiluminescence characteristics of laminar partial premixed flame as changing mixing parameters. The radical signal was acquired from ICCD camera and PMT. Each intensity was compared with Abel inverted value for measuring the effect of background light on the peak signal location and the intensity at central preheat zone. The results show that the peak location of each radical was broaden as the fuel split degree increasing because the mixing quality was enhanced. and $OH^{\ast}$ is a good indicator for flame front between reaction and preheat zone. At last $CH_{2}^{\ast}$ has the same tendency with $CH^{\ast}$ but a thinner reaction zone than $CH^{\ast}$ due to a rapid decay on the burned gas side.

  • PDF

Serial Changes of MR Images Throughout the Stages of Infection of Spondylodiscitis

  • Kwon, Tae-Hyung;Shin, Zun-Zae;Kuh, Sung-Uk;Yoon, Young-Sul;Cho, Yong-Eun;Kim, Young-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권5호
    • /
    • pp.351-356
    • /
    • 2006
  • Objective : Spondylodiscitis has been diagnosed by clinical, radiological and laboratory methods. MR imaging is well known as an excellent diagnostic tool for spondylodiscitis. However, the changes in MR images throughout the treatment process has not been studied. Thus we have analyzed the serial changes of MR images throughout the stages of infection. Methods : Ten patients were selected for retrospective reviewed who had been treated at our institute for infectious spondylodiscitis between 2000 and 2005. These patients had been followed-up at least six months and had taken more than a couple of series of MR scans. We classified the MR images into four groups according to the stages of treatment for the infection and compared them to the clinical and laboratory findings. Results : MR image signals changed minimally or appeared to be normal in the early stages. The progression of spondylodiscitis was characterized by a low T1 WI signal and a high T2 WI signal in disc and vertebral body. The signal changes of the MR images were then propagated and the end plate was destructed. During the treatment, the destructed endplate became stabilized and the signal intensity of both T1 and T2 WI were fixed to low-or iso-intensity. Conclusion : We can determine the serial signal changes based on MR images according to the treatment of spondylodiscitis. We can therefore determine the status of the infection and the stage of treatment, as well as the diagnosis of spondylodiscitis using serial MR images.

TVS에서 아크 플라즈마의 분광 측정 연구 (Spectrum Measurement Study of Arc Plasma on Triggered Vacuum Switch (TVS))

  • 남상훈;한영진;이병준;김상희;박성수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1732-1734
    • /
    • 2001
  • The purpose of this experiment was to develope Triggered Vacuum Switch(TVS) and to improve understanding of the high current vacuum arc phenomena in the TVS. The TVS has an array of rods of alternate polarity in which a fixed gap spacing is maintained between the rods. The cross section of each rod has trapezoidal shape. Breakdown of the TVS produced high current vacuum arc plasma. A spectroscopic measurement was performed over 20 kA peak current in the center of electrodes, in the vicinity of cathode, and outside electrodes. The electrode material tested was Fe. Measured Fe spectrum range was from 200 nm to 900 nm. Measurement result showed that over 90 percent of the charge states were FeII and the others were FeI and FeIII. The electron temperature was determined from the relative line intensity ratio methode of FeII system by assuming the local thermal equilibrium(LTE). The electron temperature at the center of electrodes was measured as 1.5 eV at 26 kA peak current. The electron temperature varied with its peak current. Intensity of spectrums is the highest in the vicinity of the cathode. Further we will also present study result of the diode phenomena in the TVS.

  • PDF

모래다짐말뚝과 널말뚝으로 처리된 연약점토지반의 거동 (Behavior of Soft Ground Treated with Sand Compaction Piles and Sheet Piles)

  • 유남재;정길수;박병수;김경수
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.93-99
    • /
    • 2006
  • Centrifuge model experiments were performed to investigate the confining effects of the sheet piles, installed to the sides of soft clay ground treated with sand compaction piles, on the bearing capacity and concentration ratio of composite ground. For the given g-level in the centrifuge model tests, replacement ratio of SCP and the width of surcharge loads on the surface of ground with SCP, the confining effects of installing the sheet piles on the edges of SCP ground on the bearing capacity, change of stress concentration ratio and failure mechanism were investigated. Kaolin, one of typical clay mineral, and Jumunjin standard sand were used as a soft clay ground and sand compaction pile irrespectively. As results of experiments, lateral confining effect by inserting the model sheet piles fixed to the loading plate was observed. For the strip surcharge loading condition, the yielding stress intensity in the form of the strip surcharge loads tends to increase with increasing the embedded depth of sheet piles. The stress concentration ratio was found not to be influenced consistently with the embedded depth of sheet piles whereas the effect of stress intensity on stress concentration ratio shows the general trend that values of stress concentration ratio are relatively high at the initial stage of loading and tend to decrease and converge to the certain values. For the failure mechanism in the case of reinforced with sheet piles, displacement behavior related to the punching failure, settlement right beneath the loading plate occurred since the soil was confined with sheet piles, was observed.

  • PDF

Pattern of Tissue Expression of CA-125 and HE4 in Primary Epithelial Ovarian Tumours and Correlation with Serum CA-125 Levels

  • Devan, Shobana Mukunda;Pailoor, Jayalakshmi;Sthaneshwar, Pavai;Narayanan, Vallikkanu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권8호
    • /
    • pp.4545-4548
    • /
    • 2013
  • The objective of this study is to assess tissue expression of CA-125 and HE4 protein in primary benign and malignant epithelial tumours of the ovary and correlate with serum CA-125 levels. A total of 100 formalin-fixed, paraffin embedded sections of ovarian tumours which included serous adenoma (11), mucinous adenoma (42), serous carcinoma (20), mucinous carcinoma (12) and endometrioid carcinoma (15), histologically diagnosed between $1^{st}$ January 2004 to $31^{st}$ December 2012 at the University Malaya Medical Centre, were stained for HE4 (rabbit polyclonal antibody, Abcam, UK) and CA-125 (mouse monoclonal antibody clone: OC125, Cell Marque Corporation, Rocklin, California, USA). Pre-operative serum CA-125 levels were obtained from the laboratory information system. Immunoscore (I score) for HE4 and CA-125 was given based on the intensity of staining and percentage of positive tumour cells and considered significant when it was >50 (intensity of staining multiplied by percentage of positive tumour cells). Serum CA-125 levels were compared with the I score of HE4 and CA-125 in tissues. We noted that the CA-125 levels in serum and tissues were significantly raised in malignant compared to benign ovarian tumours (p value<0.05). Tissue expression of HE4 protein was also significantly raised in malignant tumours compared to benign tumours (p value<0.05). We conclude that HE4 can be a useful tissue immunomarker in addition to CA-125.

Feasibility Study of a Custom-made Film for End-to-End Quality Assurance Test of Robotic Intensity Modulated Radiation Therapy System

  • Kim, Juhye;Park, Kwangwoo;Yoon, Jeongmin;Lee, Eungman;Cho, Samju;Ahn, Sohyun;Park, Jeongeun;Choi, Wonhoon;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.189-195
    • /
    • 2016
  • This paper aims to verify the clinical feasibility of a custom-made film created by a laser cutting tool for End-to-End (E2E) quality assurance in robotic intensity modulated radiation therapy system. The custom-made film was fabricated from the Gafchromic EBT3 film with the size of $8^{{\prime}{\prime}}{\times}10^{{\prime}{\prime}}$ using a drawing that is identical to the shape and scale of the original E2E film. The drawing was created by using a computer aided design program with the image file, which is obtained by scanning original E2E film. Beam delivery and evaluations were respectively performed with the original film and the custom-made film using fixed-cone collimator on three tracking modes: 6D skull (6DS), Xsight spine (XS), and Xsight lung (XL). The differences between total targeting errors of the original and custom-made films were recorded as 0.17 mm, 0.3 mm, and 0.17 mm at 6DS, XS, and XL tracking modes, respectively. This indicates that the custom-made film could yield nearly equivalent results to those of the original E2E film, given the uncertainties caused by distortions during film scanning and vibrations associated with film cutting. By confirming the clinical feasibility of a custom-made film for E2E testing, it can be expected that economic efficiency of the testing will increase accordingly.