• Title/Summary/Keyword: fixed prostheses

Search Result 230, Processing Time 0.029 seconds

Clinical and radiographic assessment of narrow-diameter and regular-diameter implants in the anterior and posterior jaw: 2 to 6 years of follow-up

  • Alrabiah, Mohammed;Deeb, Modhi Al;Alsahhaf, Abdulaziz;AlFawaz, Yasser F.;Al-Aali, Khulud Abdulrahman;Vohra, Fahim;Abduljabbar, Tariq
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.2
    • /
    • pp.97-105
    • /
    • 2020
  • Purpose: The present retrospective clinical study aimed to evaluate and compare the clinical and radiographic parameters, complications, and satisfaction in patients who received fixed prostheses supported by narrow-diameter implants (NDIs) in the anterior and posterior jaw. Methods: Patients aged ≥30 years who had NDI-supported fixed prostheses in the anterior or posterior region of either jaw for at least 2 years were included. Complications such as chipping of the crown; loosening or fracture of the screw, crown abutment, or implant; and loss of retention were recorded. Clinical peri-implant outcomes and crestal bone loss (CBL) were measured. A questionnaire was used to record responses regarding the aesthetics and function of the fixed restorations. Analysis of variance was used to assess the significance of between-group mean comparisons. The log-rank test was performed to analyze the influence of location and prosthesis type on technical complications. Results: Seventy-one patients (mean age: 39.6 years) provided informed consent with a mean follow-up duration of 53 months. Only bleeding on probing showed a statistically significant difference between NDIs in the anterior and posterior regions. The complication rate for NDIs in the posterior region was significantly higher than that for NDIs in the anterior region (P=0.041). For NDIs, CBL was significantly higher around splinted crowns than single crowns (P=0.022). Overall mean patient satisfaction was 10.34±3.65 on a visual analogue scale. Conclusions: NDIs in the anterior and posterior jaws functioned equally well in terms of periimplant soft and hard tissue health and offered acceptable patient satisfaction and reasonable complication rates.

Maxillary cement retained implant supported fixed prosthesis using the millingable Pd-Ag alloy generated by CAD/CAM system: clinical report after two years in service (상악 전부 무치악 환자에서 CAD/CAM 시스템으로 제작되는 Pd-Ag 합금을 이용한 고정성 임플란트 전악 수복 증례)

  • Lee, Jun-Sik;Han, Se-Jin;Choi, Yu-Sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.71-80
    • /
    • 2014
  • Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption. Therefore, it is should be cautious in making the fixed prostheses that restore the function and the esthetics of the gingiva and teeth. In full mouth rehabilitation, CAD/CAM system makes it possible to fabricate restorations with high precision, regardless of span of the restoration. Recently, Palladium-silver (Pd-Ag) alloy which is highly biocompatible and millingable has been developed to compensate for the shortcomings of the titanium or zirconia. This clinical report presents the reconstruction of a maxillary arch with a cement retained implant supported fixed prosthesis using a Pd-Ag alloy generated by CAD/CAM system on eleven osseointegrated implants. The occluding surfaces were made of Pd-Ag alloy, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.

Does the prosthesis weight matter? 3D finite element analysis of a fixed implant-supported prosthesis at different weights and implant numbers

  • Tribst, Joao Paulo Mendes;Dal Piva, Amanda Maria de Oliveira;Borges, Alexandre Luiz Souto;Rodrigues, Vinicius Aneas;Bottino, Marco Antonio;Kleverlaan, Cornelis Johannes
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.67-74
    • /
    • 2020
  • PURPOSE. This study evaluated the influence of prosthesis weight and number of implants on the bone tissue microstrain. MATERIALS AND METHODS. Fifteen (15) fixed full-arch implant-supported prosthesis designs were created using a modeling software with different numbers of implants (4, 6, or 8) and prosthesis weights (10, 15, 20, 40, or 60 g). Each solid was imported to the computer aided engineering software and tetrahedral elements formed the mesh. The material properties were assigned to each solid with isotropic and homogeneous behavior. The friction coefficient was set as 0.3 between all the metallic interfaces, 0.65 for the cortical bone-implant interface, and 0.77 for the cancellous bone-implant interface. The standard earth gravity was defined along the Z-axis and the bone was fixed. The resulting equivalent strain was assumed as failure criteria. RESULTS. The prosthesis weight was related to the bone strain. The more implants installed, the less the amount of strain generated in the bone. The most critical situation was the use of a 60 g prosthesis supported by 4 implants with the largest calculated magnitude of 39.9 mm/mm, thereby suggesting that there was no group able to induce bone remodeling simply due to the prosthesis weight. CONCLUSION. Heavier prostheses under the effect of gravity force are related to more strain being generated around the implants. Installing more implants to support the prosthesis enables attenuating the effects observed in the bone. The simulated prostheses were not able to generate harmful values of peri-implant bone strain.

Restoration of bilateral distal extension removable partial denture using a fixed implant prosthesis in unilateral partial edentulous patient: A case report (하악 편측 소수치 잔존 환자에서 임플란트 고정성 보철물을 사용하여 양측성 후방 연장 국소의치로 수복: 증례보고)

  • Kee, Wonjin;Park, Jae-Ho;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.176-181
    • /
    • 2019
  • Traditional removable partial denture is a successful treatment for partial edentulous patients. When the abutment is formed with unilateral minority teeth, satisfaction with the use of removable partial denture may be lowered due to patient's discomfort and damage of the abutment. Recently, it has been reported that the unilateral posterior extension partial denture is used as a bilateral posterior extension partial denture using implant fixed prostheses as abutments. In this case, by using implant surveyed crown prostheses, bilateral posterior extension partial denture is fabricated in site that is predicted to have a poor prognosis. This resulted in improved support, maintenance, and stabilization of the removable partial denture, which were economically beneficial to patient and satisfied with use.

Effect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses

  • Chonticha Subsomboon;Somchai Urapepon
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.4
    • /
    • pp.171-178
    • /
    • 2023
  • PURPOSE. The purpose of this study was to determine the effect of the connector configuration on the fracture load in conventional and translucent zirconia of three-unit fixed dental prostheses (FDPs). MATERIALS AND METHODS. Six different three-unit FDPs were prepared (n = 6) from three types of zirconia (3Y-TZP (Katana ML®), 4Y-TZP (Katana STML®), and 5Y-TZP (Katana UTML®)) in combination with two connector configurations (4 × 2.25, 3 × 3 mm). The CoCr master models were scanned, and the FDPs were designed and fabricated using CAD-CAM. The FDPs were cemented on the metal model and then loaded with a UTM at a crosshead speed of 1 mm/min until failure. Two-way ANOVA and Tukey's test were used for statistical analysis (α = .05). RESULTS. Fracture loads of 3Y-TZP (2740.6 ± 469.2 and 2718.7 ± 339.0 N for size 4 × 2.25 mm and 3 × 3 mm, respectively) were significantly higher than those of 4Y-TZP (1868.3 ± 281.6 and 1663.6 ± 372.7 N, respectively) and 5Y-TZP (1588.0 ± 255.0 and 1559.1 ± 110.0 N, respectively) (P < .05). No significant difference was found between fracture loads of 4Y-TZP and 5Y-TZP (P > .05). The connector configuration within 9 mm2 was found to have no effect on the fracture loads on all three types of zirconia (P > .05). CONCLUSION. Fracture loads of three-unit FDPs were affected by the type of zirconia. The fracture loads of conventional zirconia were higher than those of translucent zirconia. However, it was not affected by the connector configuration when the connector had a cross-sectional area of 9 mm2.

Implant-supported fixed prosthesis restoration of fully edentulous patient using computer-guided implant surgery and immediate loading: A case report (Computer guided implant surgery와 immediate loading을 활용한 무치악 환자의 전악 임플란트 고정성 보철물 수복 증례)

  • Hyeon-Me Sung;Kyoung-Hee Sul;Sun-Woo Kang;Jung-Han Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.131-139
    • /
    • 2024
  • In a edentulous patient, various methods can be employed for prosthetic treatment using implants, such as implant-supported fixed prostheses, overdentures, hybrid prostheses, and implant assisted removable partial denture. In this case, in a patient with moderate to severe chronic periodontitis requiring full arch extractions, implants were strategically placed using computer-guided surgery. In the maxilla, due to inadequate bone quality and quantity leading to insufficient initial stability, delayed loading was implemented, and interim prosthesis was used during the osseointegration period. In the mandible, stable initial stability was achieved, allowing for immediate loading to reduce patient discomfort. Primary stability is considered the most crucial factor for obtaining immediate loading, so a thorough clinical and radiological evaluation of the remaining alveolar bone quantity and quality must be conducted before surgery.

Fabrication of definitive complete-arch implant-supported fixed prosthesis in upper and lower completely edentulous patient using temporary prosthesis scan: a case report (상하악 완전 무치악 환자에서 임시 보철물 스캔을 이용한 일체형 임플란트 지지 고정성 보철물 수복 증례)

  • Seung-Mi Jeong;Hyun-Lak Son;Kang-Duck Choi;Byung-Ho Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.3
    • /
    • pp.243-252
    • /
    • 2024
  • When fabricating definitive implant-supported fixed prostheses in upper and lower completely edentulous patients, it is crucial to get information about the vertical dimension, jaw relationship, implants, abutments and gingival contour. In this case, temporary prostheses were used to take the information. The temporary prosthesis was scanned outside of the mouth so that it increased the efficiency of scanning it. During the scan of the prosthesis, a scan zig which connected both posterior parts of the prosthesis was used to minimize the scan errors. We report this case because we obtained satisfactory functional and esthetic results by using the digital technology.

Resin-bonded fixed partial denture using In-Ceram and Targis-Vectris system: A clinical report

  • Cha, Young-Joo;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.375-381
    • /
    • 2000
  • The conventional approach for replacing missing maxillary lateral incisors dictates the placement of either a conventional porcelain-fused-to-metal (PFM)bridge, resin-bonded fixed partial denture, or single implant prosthesis. However, several appearance-related disadvantages have been reported in the use of a prosthesis which incorporates a metal substructure. To address these limitations, metal -free restorative alternatives have been recently developed to expand the clinical options when fabrication of these prostheses is indicated. This clinical report describes the treatment of patients with a missing maxillary lateral incisor where the dentition was non-invasively restored with resin-bonded fixed partial denture(RBFPD) using In-Ceram and Targis-Vectris system.

  • PDF

A Digitally Designed All-on-4 Restoration with Screwmentable Concept

  • Park, Koungjin;Han, Jung-Suk;Lee, Jae-Hyun
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.84-91
    • /
    • 2022
  • An all-on-4 restoration allows edentulous patients to use a fixed prosthesis with a minimum number of implants. These implant-supported fixed complete dentures have traditionally been fabricated as screw-retained or cement-retained prostheses. However, it is difficult to passively fit the long-span full-arch prosthesis using the screw-retained type restoration, and predictable retrievability is not obtained with the cement-retained type. This case report describes a prosthesis fabricated using a combination of the two retention types. The screwmentable method allows the implant-supported fixed complete denture to achieve a passive fit at the connection with retrievability. In addition, a framework with an optimized size was designed by using digital dental technology.

Virtual Design Considerations for Fixed Dental Prosthesis Including Axial Contour and Proximal Contact to Maintain Periodontal Health and Physiologic Function: A Narrative Review

  • Jun-Ho Cho;Se-Hyoun Kim;Jae-Bok Lee;Hyung-In Yoon
    • Journal of Korean Dental Science
    • /
    • v.16 no.2
    • /
    • pp.105-114
    • /
    • 2023
  • The axial contour and proximal contact of the prosthesis affect periodontal health, food impaction, and patient satisfaction. This narrative review provides a summary of articles regarding the axial contour and proximal contact of a fixed dental prosthesis on periodontal health and physiologic function. By acquiring a comprehensive understanding of the axial contour and proximal contact of teeth and prostheses, as well as their functional significance, the virtual design of fixed dental prosthesis can be optimized to maintain periodontal health and promote physiologic function effectively.