• 제목/요약/키워드: fixed plate

검색결과 489건 처리시간 0.023초

레이저 절단공정에서의 토지경로 생성에 관한 연구 (A Study on Torch Path Generation for Laser Cutting Process)

  • 한국찬;나석주
    • 대한기계학회논문집A
    • /
    • 제20권6호
    • /
    • pp.1827-1835
    • /
    • 1996
  • This paper addresses the problem of a torch path generation for the 2D laser cutting of a stock plate nested with resular or irregular parts. Under the constaint of the relative positions of parts enforced by nesting, the developed torch path algorithm generate feasible cutting path. In this paper, the basic object is a polygon( a many-slide figure) with holes. A part may be represented as a number of line segments connected end-to-end in counterclockwise order, and formed a closed contour as requied for cutting paths. The objective is to tranverse this cutting contours with a minimum path length. This paper proposes a simulated annealing based dtorch path algorithm, that is an improved version of previously suggested TSP models. Since everypiercing point of parts is not fixed in advance, the algorithm solves as relazed optimization problem for the constraint, thich is one of the main features of the proposed algorithm. For aolving the torch path optimization problem, an efficient generation mechanism of neighborhood structure and as annealing shedule were introduced. In this way, a global solution can be obtained in a reasonable time. Seveeral examples are represented to ilustrate the method.

Min-Max 알고리즘을 이용한 피에조 구동형 스테이지의 최적설계 및 성능평가 (Optimal Design and Performance Evaluation of PZT-driven Stage Using Min-Max Algorithm)

  • 최기봉;한창수
    • 한국정밀공학회지
    • /
    • 제22권9호
    • /
    • pp.130-136
    • /
    • 2005
  • This paper presents an optimal design and the performance evaluation of two-axis nano positioning stage with round notched flexure hinges. A flexure hinge mechanism with round notched flexure hinges is to guide the linear motions of a moving plate in the nano positioning stage. A Min-Max algorithm is applied to the design of the flexure hinge mechanism for nano positioning stage. In the design process, the structure of the flexure hinge mechanism is fixed, then the radius of a round hole and the width of two round holes are chosen as design variables, and finally the do sign variables are calculated by the Min-Max algorithm. The machined flexure hinge mechanism, stack type PZTs for actuation and capacitance type displacement sensors for position measurement are assembled into the nano positioning stage. The experimental results of the manufactured nano positioning stage show the first modal resonance frequency of 197 Hz, the operating range of 40 um, and the resolution of 3 nm.

Validation Calculations of Simulated Shipping Container Experiments with Steel, Boral, and Cadmium Plates

  • Kim, Soon-Sam;Lee, Sang-Hee
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.33-38
    • /
    • 1997
  • Criticality experiments with fixed neutron poison plates for water moderated and reflected low enriched(2.35 and 4.31 wt%) UO$_2$fuel rod clusters were evaluated to validate calculation techniques employed in analyzing fuel shipping and storage systems having steel, boral, or cadmium shield. Measurements were obtained for both the 2.35 wt% and the 4.31 wt% enriched rods in square pitched, water flooded lattices. The critical experiments with the 2.35 wt% enriched rods consists of three 20$\chi$ 16 or 20$\chi$ 17 fuel cluster. Critical separation were used in the experiments with the 4.31 wt% enriched fuel rods. In the experiments, the poison plates were placed on both sides of the centrally located fuel cluster. Critical separation between the three sub-critical fuel clusters were then measured for varying plate thicknesses and distances of the plates to the center fuel cluster. Calculations were performed for thirty eight critical configuration using KENO-V. a and MCNP. All of the results were within 1.23% in $\Delta$k when individually compared with the critical value of 1.0. Discrepancies of the code results are probably due to uncertainties in experiments and/or analytical modeling experiments. In general, MCNP predictions were observed to be in best agreement with the experiments.

  • PDF

유골 골종에서 전산화 단층 촬영 유도하 경피적 핵 절제술 - 천공기 이용법 - (CT-Guided Percutanous Nidus Excision of Osteoid Osteoma - Burr Down Technique -)

  • 김병석;조재현;이기범;유청수;안재인
    • 대한골관절종양학회지
    • /
    • 제5권1호
    • /
    • pp.51-55
    • /
    • 1999
  • Aspirin has usually been taken for pain relief originating in the nidus of osteoid osteoma, however it takes too long to become effective. Because of the protracted painful course and the unpredictability of regression, osteoid osteoma is usually removed. And then, the defective host bone is internally fixed by plate and screws and augumented by autogenous bone graft. However, the common intracortical location and exuberant periosteal reaction hinders the exact intraoperative localization of the nidus. The authors managed 6 patients by computerized tomography-guided percutaneous nidus excision with a relatively small skin incision, small cortical window, short operation time and no bone graft. It may be one of the best options for removal of the nidus of osteoid osteoma with certainty.

  • PDF

초정밀 스테이지의 반복정밀도 분석 및 보정 (Analysis and compensation of Repeatability for Ultra-precision Stage)

  • 박종하;황주호;박천홍;홍준희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.800-803
    • /
    • 2004
  • The refractive index of the laser interferometer is compensated using the simultaneously measured variations of room temperature and humidity in the method. In order to investigate the limit of compensation, the stationary test against two fixed reflectors mounted on the zerodur plate is performed firstly. From the experiment, it is confirmed that the measuring error of the laser interferometer can be improved from 0.12$\mu$m to 0.17$\mu$m by the application of the method. Secondly, for the verification of the compensating effect, it is applied to estimate the positioning accuracy of an ultra precision aerostatic stage. Two times of the refractive index compensation are performed to acquire the positioning error of the stage from the initially measured data, that is, to the initially measured positioning error and to the measured positioning error profile after the NC compensation. Although the positioning error of anaerostatic stage cannot be clarified perfectly, it is known that by the compensation method, the measuring error by the laser interferometer can be improved to within 0.15$\mu$m. English here.

  • PDF

고분자 기판에 증착한 ITO 박막의 Bending 효과 (Bending Effects of ITO Thin Film Deposited on the Polymer Substrate)

  • 김상모;임유승;최형욱;최명규;김경환
    • 한국전기전자재료학회논문지
    • /
    • 제21권7호
    • /
    • pp.669-673
    • /
    • 2008
  • ITO thin film was deposited on PC substrate in Facing Targets Sputtering (FTS) system with various sputtering conditions. After it is applied to external bending force, we investigated how change the surface and electrical property of as-deposited ITO thin film. As the L(face-plate distance) of substrate decreases, it found that the maximum crack density is increasing at the center position and decreasing crack density as goes to the edge. So to apply same curvature (r) and bending force to PC substrate with ITO thin film, we fixed the L that is equal to curvature radius (2r). Before bending test, ITO thin films that deposited in the input current of 0.4 A and thickness of 200 nm already had biaxial tensile failure because of each different CTE (Coefficient of Thermal Expansion) and Others had been shown no bending or crack. After bending test, all samples had been shown cracks at about 200 times and as increasing the crack density, resistivity increased.

에폭시/구상실리카 콤포지트의 전기적 절연파괴 및 인장 강도 특성 연구 (A Study on Electrical Insulation Breakdown and Tensile Strength for Epoxy/Spherical Silica Composites)

  • 이승훈
    • 한국전기전자재료학회논문지
    • /
    • 제26권10호
    • /
    • pp.726-730
    • /
    • 2013
  • In order to develop a high voltage insulation material, spherical silicas with two average particle sizes of 5 ${\mu}m$ and 20 ${\mu}m$ were mixed in different mixing ratios (1:0, 0.7:0.3, 0.5:0.5, 0.3:0.7, 0:1) and their total filling content was fixed at 65 wt%. In order to observe the dispersion of the spherical silicas and the interfacial morphology between silica and epoxy matrix, field emission scanning electron microscope (FE-SEM) was used. The electrical insulation breakdown strength was estimated in sphere-plate electrodes with different insulation thicknesses of 1, 2, and 3 mm. Electrical insulation breakdown strength decreased with increasing mixing ratio of 5/20 ${\mu}m$ and the thickness dependence of the breakdown strength was also observed. The tensile strength of the neat epoxy was 82.8 MPa as average value and its increased with decreasing particles size and that of epoxy/silica (2 ${\mu}m$) was 107 MPa, which was 130.8% higher value.

유체에 부분적으로 둘러싸인 사각형 용기의 접수진동 (Hydroelastic Vibration of a Rectangular Tank Partially Surrounding with a Liquid)

  • 정경훈;김종욱
    • 한국소음진동공학회논문집
    • /
    • 제25권3호
    • /
    • pp.207-215
    • /
    • 2015
  • This paper deals with a theoretical method to calculate natural frequencies of a fixed-free rectangular tank partially in contact with an outer water gap. Orthogonal polynomials satisfying the boundary conditions of the tank are used as admissible functions in the Rayleigh-Ritz method. A quarter model of the liquid-coupled system is constructed and it is simplified to a line supported flat plate in contact with the liquid. The liquid displacement potential functions satisfying the Laplace equation and water boundary conditions are derived, and the finite Fourier transform is accomplished in conjunction with the compatibility requirement along the contacting interfaces between the tank and water. An eigenvalue problem is derived so that the natural frequencies of the wet rectangular tank can be extracted. The predictions from the proposed analytical method show good agreement with the finite element analysis results.

원형가이드 설치에 따른 충돌제트/유출냉각에서 열/물질전달 특성 (Heat/Mass Transfer for Impingement/Effusion Cooling System with Circular Guide)

  • 홍성국;조형희
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1147-1154
    • /
    • 2006
  • An experimental investigation was conducted to enhance the heat/mass transfer for impingement/effusion cooling system when the initial crossflow was formed. For the improvement of heat transfer, the circular guide is installed on the injection hole. At the fixed jet Reynolds number of 10,000, the measurements were carried out for blowing ratios ranging from 0.5 to 1.5. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The result presents that the circular guide protects the injected jet from the initial crossflow, increasing the heat/mass transfer. The heat transfer of stagnation region is hardly changed regardless of the blowing ratio. The secondary peak is obviously formed by flow transition to turbulent flow. At high blowing ratio of 1.5, the circular guide produces $26{\sim}30%$ augmentation on the averaged heat/mass transfer while the case without circular guide leads to the low and non-uniform heat/mass transfer. With the increased heat/mass transfer, the installation of circular guide is accompanied by the increase of pressure loss in the channel. However, the pressure drop caused by the circular guide is lower than that for other cooling technique with the circular pin fin.

Influence of uplift on liquid storage tanks during earthquakes

  • Ormeno, Miguel;Larkin, Tam;Chouw, Nawawi
    • Coupled systems mechanics
    • /
    • 제1권4호
    • /
    • pp.311-324
    • /
    • 2012
  • Previous investigations have demonstrated that strong earthquakes can cause severe damage or collapse to storage tanks. Theoretical studies by other researchers have shown that allowing the tank to uplift generally reduces the base shear and the base moment. This paper provides the necessary experimental confirmation of some of the numerical finding by other researchers. This paper reports on a series of experiments of a model tank containing water using a shake table. A comparison of the seismic behaviour of a fixed base system (tank with anchorage) and a system free to uplift (tank without anchorage) is considered. The six ground motions are scaled to the design spectrum provided by New Zealand Standard 1170.5 (2004) and a range of aspect ratios (height/radius) is considered. Measurements were made of the impulsive acceleration, the horizontal displacement of the top of the tank and uplift of the base plate. A preliminary comparison between the experimental results and the recommendations provided by the liquid storage tank design recommendations of the New Zealand Society for Earthquake Engineering is included. The measurement of anchorage forces required to avoid uplift under varying conditions will be discussed.