• 제목/요약/키워드: fixed plate

검색결과 489건 처리시간 0.027초

미세 딤플 가공 표면의 수력학적 윤활특성에 대한 수치해석 (NUMERICAL INVESTIGATION ON HYDRODYNAMIC LUBRICATION CHARACTERISTICS OF MICRO DIMPLE TEXTURED SURFACES)

  • 홍사훈;이재응;조민행;이성혁
    • 한국전산유체공학회지
    • /
    • 제14권4호
    • /
    • pp.56-61
    • /
    • 2009
  • This study deals with the numerical investigation on two-dimensional lubrication characteristics of micro-dimple shapes fabricated on solid surfaces by using the commercial CFD code (Fluent V.6.3) to examine the influence of micro dimple depth and width on the reduction in friction under the sliding plate condition. In addition, single and multiple dimple arrays are simulated, all for a fixed area fraction of dimple on the surface. As a result, it is found that the existence of micro-dimpled surface makes it possible to substantially reduce the friction forces exerted on the surfaces, and such an optimum dimple depth would be present because the dimple depth larger than the optimum value did no longer affect the reduction in shear stresses, indicating that the reduction of friction is likely to be associated with inner flows of lubricant inside dimples. Moreover, it is observed that at the fixed area fraction, the friction reduction increases with the increase of dimple diameter.

Control of a mobile robot supporting a task robot on the top

  • Lee, Jang M.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.1-7
    • /
    • 1996
  • This paper addresses the control problem of a mobile robot supporting a task robot with needs to be positioned precisely. The main difficulty residing in the precise control of a mobile robot supporting a task robot is providing an accurate and stable base for the task robot. That is, the end-plate of the mobile robot which is the base of the task robot can not be positioned accurately without external position sensors. This difficulty is resolved in this paper through the vision information obtained from the camera attached at the end of a task robot. First of all, the camera parameters were measured by using the images of a fixed object captured by the camera. The measured parameters include the rotation, the position, the scale factor, and the focal length of the camera. These parameters could be measured by using the features of each vertex point for a hexagonal object and by using the pin-hole model of a camera. Using the measured pose(position and orientation) of the camera and the given kinematics of the task robot, we calculate a pose of the end-plate of the mobile robot, which is used for the precise control of the mobile robot. Experimental results for the pose estimations are shown.

  • PDF

하악 협측골 시상분절술 및 장골 이식술을 이용한 거대치아종의 치험례 (A CASE REPORT OF THE HUGE COMPLEX ODONTOMA TREATED WITH THE SAGITTAL SPLITTING OF BUCCAL BONE PLATE AND ILIAC BONE GRAFT IN LEFT MANDIBLE ANGLE)

  • 김호석;송재철;김진수
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제15권4호
    • /
    • pp.269-274
    • /
    • 1993
  • This is the case report of huge complex odontoma treated with sagittal splitting of buccal bone plate and iliac bone graft in left mandible angle. The 22 years old patient was admitted to the department of Oral and Maxillofacial Surgery of Kyungpook National University Hospital with the chief complaint of swelling on the left mandible angle area. We used extra oral Risdon incision and splitted the buccal cortical bone after making the horizontal bone cut buccally. The tumor mass was removed with cutting into the pieces with surgical bur to prevent mandibular fracture. The dead space was grafted with autogenous iliac bone graft and the splitted buccal cortical bone was fixed with two L-type miniplate. After 12months follow up check, we noticed good process of bone healing and satisfactory aesthetic result. In this case, my operative approach provided the excellent surgical access to the hard tissue mass and minimized post operative complication comparing with the conventional surgical approaches.

  • PDF

평판에 충돌하는 원형분류의 공력소음에 관한 실험적 연구 (Au Experimental Study on the Aerodynamic Noise by a Circular Jet Impinging on a Plate)

  • 이동훈;권영필;한희갑
    • 소음진동
    • /
    • 제7권1호
    • /
    • pp.71-79
    • /
    • 1997
  • The objective of this study is to investigate experimentally the effect of surface conditions of the plate on the impinging jet noise. The experimental results about the spectrum, the sound pressure level and the directivity are pressented and discussed in relation with the surface conditions. Regardless of the surface conditions, the pure tones of high level are generated at the same frequency band and the overall sound power level of impinging jets is much higher than that of the free jet. However, the velocity dependence of the sound pressure level and the directivity are different between smooth surfaces and rough surfaces. The dependence of sound pressure level on the jet velocity shows that the smooth surface generates quadrupole-type sound like free jets. However, the perforated or the rough surface radiates sound power exactly proportional to the sixth power of the jet velocity, indicating that the source is fixed dipole type. The directivities of 1/3 octave band sound pressure level for both the free and impinging jet show the peak directivity at 115$^\circ$ upstream, probably due to the refraction associated with velocity gradient.

  • PDF

혼합 다채널 사형 유로의 혼합영역이 PEMFC 성능에 미치는 영향 (The Effect of Mixing Region in Mixed Multiple Serpentine Flow-field to PEMFC Performance)

  • 이지홍;이명용;김헌주;이상석;이도형
    • 한국수소및신에너지학회논문집
    • /
    • 제20권4호
    • /
    • pp.265-273
    • /
    • 2009
  • Proton Exchange Membrane Fuel Cell (PEMFC) has low operating temperature and high efficiency. And PEMFC consists of many components as bipolar plate, gas diffusion layer, membrane etc.. Flow-field in bipolar plate roles path for transporting reactants to membrane. Therefore a design of flow-field has an effect on PEMFC's performance. In this study, Computational Fluid Dynamics (CFD) simulations were performed for comparing mixed multiple serpentine (MMS) flow-field and multiple serpentine (MS) flow-field. And we studied an effect according to change mixing region design in MMS flow-field. Finally the applicability of results is verified by performing CFD simulation about fixed MMS flow-field which is combined good designs.

대형토조시험을 이용한 모래다짐말뚝이 적용된 복합지반의 침하 및 하중전이특성 (The Characteristics of the Composite Ground with Sand Compaction Pile(SCP) using Large Soil Box)

  • 김우석;박언상;김재권;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.974-981
    • /
    • 2005
  • Because general laboratory tests for sand compaction pile method including unit-cell test device have fixed outside diameter, as area replacement ratio increase, diameter of sand pile increase. These condition can bring about overestimation of stiffness of composite ground. In addition, existing large soil box which consist of bellows type loading plate can occur serious mistake in checking the amount of drained water because there are additional drainage along the inside wall in device. Overcoming these shortcoming, this paper developed modified large scale soil box consist of piston type load plate. In this study, using this device, series of modified large scale soil box tests were performed, and investigated the settlement and stress transportation characteristics with area replacement ratio in sand compaction pile method.

  • PDF

Delayed degradation according to the location of fixation with using an absorbable plate

  • Kim, Tae Ho;Kang, Seok Joo;Sun, Hook
    • 대한두개안면성형외과학회지
    • /
    • 제19권2호
    • /
    • pp.114-119
    • /
    • 2018
  • Background: The ideal absorbable plating system should provide sufficient rigidity and then be absorbed within a timely manner. The Resorb-X has been recently developed as a plating system with a mixture ratio of 50:50 poly(D, L-lactide). Methods: We present seven of 121 patients who experienced delayed degradation with this absorbable plate. One hundred twenty-one patients with facial bone fracture underwent surgical treatment from March 2011 to March 2015, and rigid fixation was achieved with the Resorb-X. Results: Of 121 patients, seven (5.8%) developed complications at the surgical sites. Six of 102 cases underwent fixation of the infraorbital rim and one of 73 underwent fixation of the frontozygomatic buttress; the other sites of fixation did not develop delayed degradation. Foreign body granuloma developed at the earliest by postoperative 20 months and at the latest by postoperative 28 months (average, 23.5 months). Conclusion: We observed that the use of absorbable plates in incision sites or areas with thin skin can increase the possibility of delayed degradation. When performing surgery in these areas, the normal skin above the fixed location should be covered sufficiently.

전자기력 조합에 기초한 평면 구동기를 이용한 자기 부상 방식 초정밀 스테이지 (Precision Stage Using A Novel Contact-Free Planar Actuator Based on Combination of Electromagnetic forces)

  • 정광석;백윤수
    • 대한기계학회논문집A
    • /
    • 제25권11호
    • /
    • pp.1863-1872
    • /
    • 2001
  • In this Paper, we suggest the precision stage using a novel non-contact planar actuator that utilizes an interaction between an array type of air-core solenoids and permanent magnets. The former with axes arranged in the mutually orthogonal direction is fixed on the stator and the latter with the same polar direction is attached below the stage. The promising magnetic structure has little uncertainty such as hysteresis loss caused by ferromagnetic material, then it is simple to quantify the magnetic phenomenon. And all the magnetic forces are transmitted through narrow air-gap between the coil and the permanent magnet, therefore the structure can be highly compacted. Furthermore, the stage or plate can be perfectly isolated from the stator without any wire connection, leading to diminish the generating possibility of wear particles due to mechanical contact. Then. it is estimated that the proposed operating principle is very suitable for work requiring high accuracy and cleanness. or general-purpose nano stage. The main issues rebated to the plate driving are discussed here.

충돌제트/유출냉각기법에서 횡방향유동이 열/물질전달에 미치는 영향 (Effect of Crossflow on Heat (Mass) Transfer of an Impingement/Effusion Cooling System)

  • 남용우;최종현;조형희;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2219-2226
    • /
    • 2003
  • Two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of the hole diameter, and initial crossflow passes between the plates. Both the injection and effusion hole diameters are 10 mm, and the Reynolds number based on the hole diameter and hole-to-hole pitch are fixed to 10,000 and 6 times of the hole diameter, respectively. To investigate the effect of crossflow, the flow rate of crossflow is changed from 0.2 to 2 times of that of the impinging jet. A naphthalene sublimation method is used to determine the local heat/mass transfer coefficients on the upward facing surface of the effusion plate. With the initial crossflow, the heat/mass transfer rates on the effusion (target) plate decrease as the velocity of crossflow increases, since the crossflow induces the locally low transfer regions formed at the mid-way between the effusion holes. However, the impingement/effusion cooling with crossflow presents higher heat/mass transfer rates than the array jet impingement cooling with the same initial crossflow.

  • PDF

타워형 태양열발전을 위한 열유속 분포 측정기술 개발 (Development of Flux Mapping Technique for the Solar Power Tower Plant)

  • 채관교;이현진;김종규;윤환기;이상남;강용혁;서태범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.274-279
    • /
    • 2012
  • Daegu Solar Power Tower Plant of 200 kW thermal capacity was developed for the first time in Korea, 2011. Measurement of the heat flux distribution is essential to evaluate the solar energy concentrated by reflectors and to design a suitable receiver. The flux mapping technique, which uses a radiometer and a diffuse plate, is common for measurement of the heat flux distribution. Because the solar power tower plant has a wide concentration area, the flux mapping technique using a fixed diffuse plate is difficult to apply. Therefore, the flux distribution in the solar power tower plant should be measured by the flux mapping technique using a small moving bar. In this study, we measured flux distributions with the moving-bar system developed at the KIER solar furnace and evaluated its applicability for the solar power tower plant.

  • PDF