• Title/Summary/Keyword: fixed plate

Search Result 487, Processing Time 0.029 seconds

An estimate of structure-borne sound by the excitation at an arbitrary point on the rectangular plate with fixed edges (주변고정 장방형 평판에 있어서 임의점 가진에 의한 고체전파음의 예측)

  • 김의간
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.21-34
    • /
    • 1988
  • Machinery enclosures are widely adopted to reduce the noise emission in various fields of application. Emitted noise, which is due to the vibration of enclosure's outer surface, is composed of two kinds of sound with different path of propagation. One is the "structure-borne sound", while the other is "air-borne sound". In order to get a most efficient machinery enclouser a prudent consideration upon the above structure-borne and air-borne sound is required, as the guiding principle of contermeasure for each noise is quite different. The controlling of input vibration and its isolation are major subjects for the structure-borne sound, and the specifications of absorbing members and damping panels are the major related matters for the air-borne sound. Hence, it seems very efficient to separate the total sounds into two categories with a great accuracy when one think of further reduction of noise from the existing enclosure, although its separating methods have not been made clear for many years. Author proposes an application method of experimental modal analysis to extract the structure-borne sound from the measured total radiation sound, as the air-borne sound is deduced by the vectorial difference between the measured total radiation sound and the calculated structure-borne sound. In order to calculate the correct structure-borne sound by the excitation at an arbitrary point on the enclosure structure, it is important to decide 1) how to estimate the enclosure's surface vibration velocity and 2) how to compute the radiation sound which is considered as the effect of vibration modes of enclosure surface. The former can be solved with total frequency response function calculated by the application of experimental modal analysis. The latter is to be solved by the author's new approaches for radiation sound computation by means of the Rayleigh's integral equation and the boundary-element method applied complex surface vibration velocity. As a first step, structure-borne sound by the excitation at an arbitry point on the rectangular plate with fixed edges, has been calculated to verified the reliability of the developed computation methods. The results of calculation show good agreements with those of the actual measurements.actual measurements.

  • PDF

Correction of Lowerlid Entropion by Using Skin-tarsal Fixation Method (피부검판 고정술을 이용한 하안검 내반증의 교정)

  • Hong, Jung Soo;Kim, Han Koo;Kim, Woo Seob;Kim, Seung Hong
    • Archives of Plastic Surgery
    • /
    • v.32 no.3
    • /
    • pp.397-402
    • /
    • 2005
  • For its lowerlid entropion correction, nonsurgical eyelid suture or surgical eyelid suture can be employed. Different types of surgical eyelid suture such as the Hotz method and the Callahan method, are generally performed, but were not sufficient for correcting of entropion. In our hospital we performed modified skin-tarsal fixation on 15 patients, 5 male and 10 female from January 20, 1999 to December 16, 2002. We corrected lower eyelid entropion with the excision of the skin and orbicularis oculi muscle and buried suture of tarsal plate and dermis which is a variant of the Callahan method. All the patients were satisfied with the operation results, and there was no case of recurrence of the lower eyelid pricking the cornea. During the 6 months period after the operation, the lower eyelids slightly turned inward but there was no further progression. The correction was performed excessively, therefore there was no case of recurrence after the operation and the results were satisfactory. There developed a dimple at the suture margin caused by skin contraction but it usually disappeared within 2 months after the operation. To avoid recurrence and to achieve satisfactory results, the orbicularis oculi muscle must be totally resected at the ciliary margin. We resected ciliary as well as pretarsal portion of orbicularis oculi muscle. Also, since most of the recurrences are originated from the medial side, the medial portion of skin flap must be tightly fixed to avoid recurrence and the upper part of the dermis should be fixed tightly to the lower border of the tarsal plate.

Versatility of n-butyl-2-Cyanoacrylate for the Reconstruction of Frontal Sinus Comminuted Fracture in Children (소아의 전두동에 발생한 복잡골절에서 Cyanoacrylate의 유용성)

  • Lee, Yong-Seok;Kang, Sang-Gue;Chun, Nam-Joo;Kim, Cheol-Hann;Tark, Min-Seong
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.96-101
    • /
    • 2011
  • Purpose: In treatment of facial bone fracture, occurred in children, we generally use wires, miniplate, absorbable plate or their combination. These foreign bodies can be palpable, and sometimes may cause infections, and need reoperation for removing. When bone fragments are multiple, small or thin, they are hard to handle and make accurate reduction of all fragments. In these cases, a biodegradable tissue adhesive, Histoacryl$^{(R)}$ (n-butyl-2-cyanoacrylate), can be used as fixation technique for small, multiple, and thin fracture fragments. Methods: 3 years old and 6 years old children, who has comminuted fracture on frontal sinus, we used Histoacryl$^{(R)}$ for fixation of multiple bone fragments. After approaching by coronal incision, we pulled out all bone fragments and reconstructed bone fragments by Histoacryl$^{(R)}$ and fixed those on frontal sinus by absorbable plates. Results: Photographs and 3-dimensional CT obtained preoperatively and postoperatively. And we compared them each other in terms of accuracy of reconstructed bony contour. We could reconstruct almost all bone fragments easily along 3-dimensional structure and get excellent aesthetic results. There was no complication such as infection. Conclusion: In treatment of comminuted facial bone fracture, occurred in children, Histoacryl$^{(R)}$ is an excellent method for accurate reconstruction in small and thin bone fragments which cannot be fixed by wire, miniplate or absorbable plate without complication.

Cyclic Loading Test for Exposed Column-base Plate Connections of Small-size Steel Structures (소규모 철골조 노출형 주각부의 반복가력 실험)

  • Lim, Woo-Young;You, Young-Chan;Yoo, Mi-Na
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.34-45
    • /
    • 2017
  • Cyclic loading tests for a total of nine test specimens were performed to evaluate the seismic performance of the exposed steel column-base plate connections. From the tests, flexural strength, deformation capacity, energy dissipation, and initial stiffness were investigated. The primary test parameters were the thickness of base-plate, embedment length of anchor bolt, the presence of hook, and rib plates. Test results showed that flexural behavior of column base-plate connection was substantially affected by the base-plate thickness, embedment length and the number of anchor bolts. On the other hand, the effect of rib plates on the increase of the flexural performance was not observed. The initial stiffness of the test specimens was about 15% of the flexural stiffness obtained by assuming that the support is fixed. As a result, even if the exposed column base-plate is designed in accordance with current design recommendations, in case that bond strength between concrete and the anchor bolts is not sufficient, the base-plate connection showed an unaccceptable load-displacement behavior.

Analysis on the Characteristics of the Superconducting Electrodynamic Suspension According to the Variation of the Ground Conductor (지상도체 변화에 따른 초전도 반발식 자기부상 특성 해석)

  • Bae, Duck-Kweon;Cho, Han-Wook;Lee, Jong-Min;Han, Hyung-Suk;Lee, Chang-Young;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1159_1160
    • /
    • 2009
  • This paper presents the numerical simulation results on the supercodnucting electrodynamic suspension (EDS) simulator according to the variation of the ground conductor. The levitation force of the EDS system is formed by the reaction between the moving magnet and the fixed ground conductor. The possible way to simulate the EDS system were simulated in this paper by using finite element method (FEM). The static type simulator which consists of the fixed magnet, the fixed ground conductor and the ac current supply system. To verify the characteristics of high speed EDS system with the moving type simulator heavy, large and fast moving ground conductor is needed. The static type simulator can get the characteristics of the high speed EDS system by applying equivalent ac current to velocity, therefore it does not need large moving part. The static type EDS simulator, which can consist of an HTS magnet, the fixed ground conductor(s), an AC power supply and the measuring devices, also test the effect of the shape of the ground conductor easily. The plate type ground conductor made stronger levitation force than ring type ground conductor. Although the outer diameter 335 mm ring type ground conductor (Ring3) was larger than the outer diameter 235 mm ground conductor (Ring2), the levitation force by Ring2 was stronger than that by Ring3. From the calculation results on this paper, the consideration of the magnetic flux distribution according to the levitation height should be included in the process of the ground conductor design.

  • PDF

Viscous Flow Analysis around a Wind Turbine Blade with End Plate and Rake (풍력터빈 날개의 끝판과 레이크 효과에 대한 점성유동장 해석)

  • Kim, Ju-In;Kim, Wu-Joan
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.4
    • /
    • pp.273-279
    • /
    • 2011
  • Turbulent flow analysis around a wind turbine blade was performed to evaluate the power performance of offshore wind turbine. Fluent package was utilized to solve the Reynolds-averaged Navier-Stokes equations in non-inertial rotating coordinates. The realizable k-$\varepsilon$ model was used for turbulence closure and the grid system combining structured and unstructured grids was generated. In the first, lift and drag forces of 2-D foil section were calculated and compared with existing experimental data for the validation. Then torque and thrust of the wind turbine blade having NACA 4-series sections were calculated with fixed pitch angle and rpm. Tip speed ratio was varied by changing wind speed. In the next, three kinds of end plate were attached at the tip of blade in order to increase the power of the wind turbine. Among them the end plate attached at the suction side of the blade was found to be most effective. Furthermore, performance analysis with tilt angle and rake was also performed.

Ultrastructural Studies of Effect of Monosodium Glutamate on the Epiphyseal Plate of Femur in Young Chicken (Monosodium Glutamate가 초생추 대퇴골 근위골단에 미치는 영향에 관한 투과 및 주사전자현미경적 연구)

  • Yang, Hong-Hyun;Lee, Heung-Shik;Lee, In-Se;Kim, Jin-Sang
    • Applied Microscopy
    • /
    • v.20 no.1
    • /
    • pp.90-104
    • /
    • 1990
  • This study was carried out to investigate the ultrastructural changes of the proximal epiphyseal plate of the femur in young chickens that had been treated with monosodium glutamate(MSG). Eighty 1-day old broiler chickens(Hubbard strain) were divided into control and experimental groups. The experimental group received daily administration of MSG(3mg/g of body weight in 0.75% saline) per orally for 1, 3, 6, 9, 12, 15, 18 and 21 days, and were sacrificed with exanguination. The control group received an equal volume of 0.75% saline. For the transmission electron microscopy, the prehypertrophic cartilage zone of epiphyseal plate was cleaved, fixed with 2% glutaraldehyde(containing 0.2% ruthenium red), postfixed with 1 % osmium tetroxide, embedded in Epon 812, and stained with uranyl acetate and lead citrate. For the scanning electron microscopy, the calcified zone of epiphyseal plate was cleaved and coated with gold palladium. The results obtained were as follows; 1. On transmission electron microscopic examination, the sacculation decreased from 12 day to 21 day MSG administrated groups, and the vesiculation decreased in 18 and 21 day MSG administrated groups in rough endoplasmic reticulum of chondrocytes in prehypertrophic cartilage zone. The ruthenium red binding particles in pericellular rim, territorial matrix and interterritorial matrix increased from 9 day to 21 day MSG administrated groups, but the crystalloid materials decreased. 2. On scanning electron microscopic examination, the trabecular formation and calcospherites of calcification zone decreased in 18 and 21 day MSG administrated groups. The resorption cavities widened from 15 day to 21 day MSG administrated groups.

  • PDF

An Experimental Study on Evaporation/Condensation Heat Transfer with Flow Direction in Brazed Plate Heat Exchanger using Refrigerant 410A (R410A를 이용한 브레이징 타입 판형열교환기에서 물 측 유동방향에 따른 응축/증발 성능 평가)

  • Lee, Sung-Woo;Jeong, Young-Man;Lee, Jae-Keun;Lee, Dong-Hyuk
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1096-1101
    • /
    • 2009
  • The plate heat exchanger(PHE) in heat pump has two flow streams of the refrigerant and water. The flow direction of the refrigerant, unlike that of water, can be changed by a 4-way valve depending on operating condition. Therefore the flow arrangement is a parallel flow for heating and a counter flow for cooling, respectively. In this study, the effects of the flow direction of the water on the heat transfer rate are investigated experimentally. The experiments are carried out for brazed plate heat exchangers under a parallel and counter flow conditions in evaporation and condensation. The experimental parameters in this study include the mass flux of the refrigerant 410A from 3 to $14\;kg/m^2s$ and the flow patterns for the pressure of PHE fixed at 0.97 and 2.46 MPa. The results show that both the heat transfer rate and frictional pressure drop across the PHE increase with the mass flux. The heat transfer rate of the refrigerant 410A for evaporation show great sensitivity to flow direction of the water. The heat transfer rate for evaporation with a counter flow are 5-30% higher than that with a parallel flow.

  • PDF

Assessment of Optimum Reinforcement of Rebar for Joint of PHC Pile and Foundation Plate (고강도 콘크리트 말뚝과 기초판 접합부의 최적 철근보강량 산정)

  • Park, Jong-Bae;Sim, Young-Jong;Chun, Young-Soo;Park, Seong-Sik;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.1 no.1
    • /
    • pp.67-73
    • /
    • 2010
  • Method of protruding steel bar embedded in PHC pile for connecting with foundation plate is an intermediate form of fixed and hinged connection and has often been used in architectural structures such as apartment complex. However, mechanical properties of this method have not been proved and its construction process is not simple. In this study, therefore, by analyzing previous research and by considering ratio of steel bar and concrete in PHC pile, which is minimum reinforcement of rebar, the newly optimized method of reinforcing joint of PHC pile and foundation plate is suggested with respect to PHC pile type (PHC 450, PHC 500, and PHC 600). To assess mechanical properties (ultimate tensile and shear strength) of joint of PHC pile and foundation plate, full scale experimental tests are performed. As a result, all cases are satisfied with required design criteria and can be practically applied. Our results indicate that reduction of rebar reinforcement compared to previous method would lead cost saving in PHC pile construction.

Preparation and Characterization of Organic-inorganic Hybrid Composite Film with Plate-shaped Alumina by Electrophoretic Deposition as a Function of Aging Time of Sol-Gel Binder

  • Kim, Doo Hwan;Park, Hee Jeong;Choi, Jinsub;Lim, Hyung Mi
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.5
    • /
    • pp.366-373
    • /
    • 2015
  • Sol-gel binder was prepared by hydrolysis and condensation reaction using boehmite sol and methyltrimethoxysilane as a function of aging-time. The coating slurry was composed of a plate-shape alumina in the sol-gel binder for the EPD process, in which particles dispersed in the slurry were deposited on the electrode under an electric field due to the surface charge. We studied the effects of three parameters: the content of boehmite, the aging time, and the applied voltage, on the physical, thermal, and electrical properties of the hybrid composite films by EPD. The amount of boehmite was 10 ~ 20 wt% and the aging time was 0.5 ~ 72, with a fixed amount of plate-shape alumina of 10 wt%. The condition of applied voltage was 5 ~ 30 V with a distance of 2 cm between the electrode during the EPD process. We confirmed that a structure of hybrid composite films of well-ordered plate alumina was deposited on the substrate when the film was prepared using a sol-gel binder composed of 15 wt% boehmite with 1 hr aging time and EPD at 10 V. The process shows a weight loss of 7% at $500^{\circ}C$ in TGA and a breakdown voltage of 8 kV at $87{\mu}m$.