• 제목/요약/키워드: fixation device

검색결과 91건 처리시간 0.024초

자가 확장형 전방십자인대 고정장치의 고정 특성에 대한 연구 (A Study on the Fixation Characteristics of a Self-expansion Type ACL Fixation Device)

  • 김종대;김홍건
    • 한국생산제조학회지
    • /
    • 제18권3호
    • /
    • pp.321-327
    • /
    • 2009
  • This paper studied the influences of the main design parameter-the expansion angle and the material properties of the self-expansion anterior cruciate ligament fixation device on the contact condition with the bone and the initial stability of the device. Using finite element analysis, the stress distributions of the ring part of the device and the wall of the bone tunnel were calculated. And the micro-migration of the device by the pull-out force was calculated. From the analysis results, it was found that when designing the self-expansion type anterior cruciate ligament fixation device, it is desirable to use the material having higher Young's modulus and to design the fixation device that all wedges uniformly maintain contact with bone to obtain initial stability after operation.

  • PDF

하악골 양측 하악지 시상분할 골절단술 후 흡수성 고정의 안정성에 관한 연구 (The study of stability of absorbable internal fixation after mandibular bilateral sagittal split ramal osteotomy)

  • 최병환;박수원;장수미;손한나;박봉찬;손장호;조영철;성일용
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권4호
    • /
    • pp.255-261
    • /
    • 2010
  • Introduction: To evaluate the skeletal stability after a bilateral sagittal split osteotomy (BSSO) setback of the mandible fixed with a biodegradable internal fixation device or metal internal fixation device. Materials and Methods: Thirty consecutive patients underwent mandibular setback via BSSO. Fifteen patients were fixed with a biodegradable internal fixation device or metal internal fixation device respectively. Posteroanterior (PA) and lateral cephalograms were taken preoperatively and at two days, 5.5 months and 14.5 months postoperatively. The relevant skeletal points were traced and digitized to evaluate the skeletal changes postoperatively. The relapse rates were analyzed and compared statistically. Results: There was no statistically significant differences in postoperative stability between the two groups.(P<0.05) Conclusion: The biodegradable internal fixation device may make an effective device alternative to a metal internal fixation device for setback BSSO.

Development and Evaluation of Fixation Equipment for Transporting Unit Modules

  • Park, Su-Yeul;Kim, Kyoon-Tai;Park, Nam-Cheon
    • 한국건축시공학회지
    • /
    • 제13권6호
    • /
    • pp.609-618
    • /
    • 2013
  • The unit modular construction system is a building technique in which unit modules are manufactured at a factory and then assembled at the construction site. It has many benefits, including reduction of the construction period and improvement in quality. For this reason, it is utilized for various purposes in Japan and England. While it has been introduced in Korea, there have been few Korean studies conducted on the unit modular system. In particular, little research has been done on the method of safely fixating the unit modules to a truck. Therefore, this study reviewed the fixation methods of unit modules for transport, analyzed the problems, and designed a fixation device for unit modules. In addition, a device for the fixation of unit modules to a truck was developed, and a structural simulation was implemented for a safety test by considering the maximum stress generated during the transport of the unit modules fixed on a truck. When the device for the fixation of unit modules is manufactured based on the results of the structural simulation done in this study, it is expected to aid the development of a more practical fixation device for unit modules.

TightRope$^{TM}$ Device를 이용한 족근 중족 관절 손상의 치료(1예 보고) (Lisfranc Injury Repair with the TightRope$^{TM}$ Device (A Case Report))

  • 조재호;오인석
    • 대한족부족관절학회지
    • /
    • 제15권4호
    • /
    • pp.243-246
    • /
    • 2011
  • Lisfranc injury is complex and difficult to treat. Making the correct diagnosis and achieving an anatomical reduction are important factors in regard to achieving a favorable outcome with this injury. We describe a new technique that we have found to be useful for stabilizing Lisfranc injury. This method is relatively fast and simple, and it provides non-rigid fixation. Also, it eliminates the need for implant removal. To date, we have achieved predictable results for stabilizing and treating this injury with the use of a $TightRope^{TM}$ Device, instead of traditional interfragmental screw fixation. In this report, we describe a case in which this method was used with satisfactory short-term results.

심폐소생술 시 아이젤의 고정 방법에 따른 환기량의 변화 비교: 시뮬레이션 마네킨을 이용한 연구 (Comparison of changes in ventilation volume according to fixation method of I-gel during cardiopulmonary resuscitation: a study using a simulated manikin)

  • 김선태;신상열;최정우
    • 한국응급구조학회지
    • /
    • 제25권3호
    • /
    • pp.7-16
    • /
    • 2021
  • Purpose: The I-gel device is Korea's most frequently used airway management method during pre-hospital cardiopulmonary resuscitation (CPR). This study aimed to compare changes in ventilation volume according to the fixation method with a simulated manikin. Methods: We placed I-gel into an advanced life support simulator and compared tape and band fixation conditions. CPR was performed according to the 2020 Korean CPR guidelines, using a mechanical chest compression device and an adult bag. The positional shift of I-gel and the ventilation volume of the simulated manikin were measured after performing CPR for 20 minutes. Five trials were carried out in each setting. Statistical analysis was carried out with SPSS 27.0. P < .05 was considered significant. Results: Positional shift after 20 minutes of CPR was as follows: tape fixation, 7.2 ± 0.2 mm; band fixation, no change, indicating a significant difference between the two groups (p=.003). The mean ventilation volume was tape fixation, 482.63 ± 30.84 mL; band fixation, 544.96 ± 22.98 mL, showing a significant difference (p=.002). Conclusion: When using the I-gel during pre-hospital CPR, using a band-type fixing device with elasticity rather than fixing the tape provides stable and appropriate ventilation by maintaining the fixed position.

소아중환자실 환아의 호흡기계 의료장치 관련 욕창 발생 관련 특성 (Characteristics Influencing the Occurrence of Respiratory Medical Device-related Pressure Ulcers in the Pediatric Intensive Care Unit)

  • 김혜경;김영혜;손현미
    • Child Health Nursing Research
    • /
    • 제25권2호
    • /
    • pp.133-142
    • /
    • 2019
  • Purpose: This prospective study was conducted to determine the incidence and related characteristics of respiratory medical device-related pressure ulcers (MDRPU) in children admitted to a pediatric intensive care unit (PICU). Methods: The participants were 184 children who were admitted to the PICU of P University Hospital from April 2016 to January 2017. Data were collected on the occurrence of respiratory MDRPU and characteristics regarding the application of respiratory medical devices. Results: Respiratory MDRPU occurred in 11.9% of participants (58.3%: stage I ulcers, 37.5%: mucosal ulcers). The devices associated with respiratory MDRPU were endotracheal tubes (54.2%), high-flow nasal cannulas (37.5%), and oximetry probes (8.3%). Respiratory MDRPU associated with an endotracheal tube were significant differences according to the site and strength of fixation, the use of a bite block and adhesive tape, skin dryness, and edema. In high-flow nasal cannulas, significant differences were found according to the site of fixation, immobility after fixation, and skin dryness. Conclusion: The occurrence of respiratory MDRPU is significantly affected by the method and strength of fixation, as well as skin dryness and edema. Therefore, appropriate consideration of these factors in nursing care can help prevent respiratory MDRPU.

Wesson Fixation Disparity Card를 이용한 양안시 분석 (Analysis of Binocular Vision by Wesson Fixation Disparity Card)

  • 박현주
    • 한국안광학회지
    • /
    • 제12권1호
    • /
    • pp.53-59
    • /
    • 2007
  • 가장 일반적으로 사용되는 주시시차 측정 장치는 Wesson 주시시차 카드이다. 주시시차곡선은 추가한 프리즘량과 주시시차량에 대한 함수이며, 주시시차 곡선에서 진단과 처방에 사용되는 값은 x-절편, y-절편, 기울기, 곡선 타입이다. Wesson 주시시차 카드를 이용하여 102명을 대상으로 주시시차를 측정하였는데, 이 연구의 목적은 Wesson 주시시차카드를 이용한 주시시차 검사법에 의해 주시시차의 방향과 분포 등을 알아보고, 진단과 처방에 응용하는데 있다. Wesson 주시시차 카드를 이용한 주시시차 측정 결과 type I은 63.0%, type II는 0.0%, type III는 25.0% type IV는 12.0%를 얻었다.

  • PDF

응급실 침대 위 흉부전후방향 엑스선 검사를 위한 상의고정장치 개발 (Development of the Upper Wear Fixation Device for Chest AP X-ray Imaging on the Emergency Stretcher Bed)

  • 임우택;홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.205-211
    • /
    • 2022
  • This study aimed to provide basic data for 3D printing in the medical health field by developing upper wear fixation device (UWFD), an auxiliary device for shortening chest AP examination time on emergency room beds and non-contact with patients. The standard of hooks was modeled according to the bed frame using the Autodesk Fusion 360. It was printed with Form2 (Formlabs, Somerville, MA, USA), as SLA (stereo lithography apparatus) method, and was washed and hardened using Form Wash and Form Cure. The completed UWFD conducted an online survey on 4 items of stability, convenience, availability, preference and general characteristics. The total stability average was 3.93±0.80, the total convenience average was 3.93±0.68, the total availability average was 4.01±0.89, and the total preference average was 3.80±1.08. This study was significant in suggesting improvements in the general X-ray examination process in the emergency room by designing and making aids to easily fixing the patient's top to the frame of the emergency bed while meeting promptness and non-contact with the patient.

Breast Board를 이용한 방사선치료에서 환자 위치 재현성 향상 방안에 대한 연구 (Development of Devices for Improving the Reducibility of Patient Positioning on a Breast Board)

  • 허순녕;조웅;박양균;하성환
    • Radiation Oncology Journal
    • /
    • 제23권2호
    • /
    • pp.123-130
    • /
    • 2005
  • 목적: 유방암 환자치료 과정에서 breast board를 이용한 방사선 치료시, 환자 위치 재현성을 향상시킬 수 있는 방법론을 개발하고, 효용성을 검증한다. 대상 및 방법: 환자와 breast board 사이에서 기존의 오목한 두개골 판 사용시 발생할 수 있는 오차를 개선하기 위해서, 두경부 지지대를 breast board에 장착할 수 있도록 개조한 장치를 개발하였다. 이 장치가 breast board에 장착된 상태에서 두부(頭部)의 위치를 측정할 수 있는 계측도구를 사용하여, 체중이 다른 2명의 자원자에 대해 각각 50회에 걸쳐 재현성을 검증하였다. breast board의 좌우 방향의 기울어짐을 방지하기 위하여서는, breast board 상하부에 지지대를 장착하여 높이에 맞게 아크릴 판을 삽입하여 좌우를 고정하는 계단형 좌우 고정장치와, breast board 측면에 홈으로 연결된 두 개의 알루미늄 지지대를 장착하여, 수평계로 보정된 높이를 고정시킬 수 있는 팔걸이형 좌우 고정장치를 개발하였다. 장치의 유무에 따라 좌우의 편중 하중에 대한 breast board의 좌우 높이(기준 위치) 변화를 수회 측정하여, 기울어짐의 전도를 수치적으로 환산함으로써 장치의 효용성을 검증하였다. 결과: Cranio-caudal 방향 오차에 대해서는 50 kg, 70 kg의 체중을 가진 2명의 자원자에 대하여 5단계(3 cm, 10 cm, 20 cm, 30 cm, 39 cm)의 breast board 높이에 따라 각각 10회씩, 기존의 오목한 두개골 판과 개선된 두경부지지대를 비교하여 실험을 수행한 결과, cranio-caudal 방향 위치의 표준편차가 평균 $55\%$ 이상 감소하였다. 계단형 좌우 고정장치의 효용성을 검토한 결과 50 kg, 70 kg 체중의 자원자에 대하여 각각 $73\%$, $85\%$ 이상의 기울기 감소 효과가 나타났고, 팔걸이형 좌우 고정장치에 대해서는 각각 $90\%$ 이상의 기울기가 감소한 것으로 나타났다. 결론: 모의 실험 결과, 개선된 두경부 지지대와 좌우 고정장치를 통해 cranio-caudal 방향 위치와 breast board의 기울기의 편차가 기존에 비해 현저하게 감소하였으므로, 임상적용시 환자 위치의 재현성 향상에 기여할 것으로 기대된다.

Biomechanical Comparison of Spinal Fusion Methods Using Interspinous Process Compressor and Pedicle Screw Fixation System Based on Finite Element Method

  • Choi, Jisoo;Kim, Sohee;Shin, Dong-Ah
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권2호
    • /
    • pp.91-97
    • /
    • 2016
  • Objective : To investigate the biomechanical effects of a newly proposed Interspinous Process Compressor (IPC) and compare with pedicle screw fixation at surgical and adjacent levels of lumbar spine. Methods : A three dimensional finite element model of intact lumbar spine was constructed and two spinal fusion models using pedicle screw fixation system and a new type of interspinous devices, IPC, were developed. The biomechanical effects such as range of motion (ROM) and facet contact force were analyzed at surgical level (L3/4) and adjacent levels (L2/3, L4/5). In addition, the stress in adjacent intervertebral discs (D2, D4) was investigated. Results : The entire results show biomechanical parameters such as ROM, facet contact force, and stress in adjacent intervertebral discs were similar between PLIF and IPC models in all motions based on the assumption that the implants were perfectly fused with the spine. Conclusion : The newly proposed fusion device, IPC, had similar fusion effect at surgical level, and biomechanical effects at adjacent levels were also similar with those of pedicle screw fixation system. However, for clinical applications, real fusion effect between spinous process and hooks, duration of fusion, and influence on spinous process need to be investigated through clinical study.