• Title/Summary/Keyword: fixation characteristics

Search Result 249, Processing Time 0.025 seconds

A study on subjective oral health awareness and denture satisfaction among elderly people (노인의 주관적 구강건강인식과 의치만족도)

  • Kang, Yong-Ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.355-363
    • /
    • 2012
  • Objectives : The purpose of this study was to examine the influential factors for denture-wearing elderly people's denture satisfaction and subjective oral health and the relationship between the two in an effort to provide some information on the oral health promotion of the elderly. The subjects in this study were 192 senior citizens who were residing in the city of Busan and were wearing denture. Methods : The collected data were analyzed by the statistical package SPSS 18.0. To see whether there would be any differences in subjective oral health awareness according to general characteristics and denture-related characteristics, $x^2$-test was carried out, and t-test or one-way ANOVA involving Duncan post-hoc analysis was utilized to look for any possible gaps in denture satisfaction according to those characteristics. Results : 1. Concerning oral health awareness by general characteristics, there were significant differences according to gender and the form of health insurance subscription. 2. As for subjective oral health awareness by denture-related characteristics, there were significant gaps according to denture-washing frequency. 3. Regarding denture satisfaction by general characteristics, there were significant differences in satisfaction with denture fixation according to living arrangements. 4. As to denture satisfaction by denture-related characteristics, there were significant differences in satisfaction with mastication and with fixation according to the type of denture. 5. Better subjective oral health awareness led to better satisfaction with mastication, better satisfaction with fixation and better aesthetic satisfaction. 6. In relation to subjective oral health awareness and denture satisfaction, that had a significant relationship to satisfaction with mastication and with fixation. Conclusions : The above-mentioned findings showed that the denture satisfaction of the denture-wearing senior citizens was linked to their subjective oral health awareness. Therefore it will be possible to improve denture-wearing elderly people's quality of life when oral health plans geared toward boosting their denture satisfaction are carried out.

Seasonal changes of nitrogen fixation and growth characteristics of kummerowia striata(thunb)schindl. populations (매듭풀 ( Kummerowia striata ( Thunb. ) Schindl. ) 개체군의 질소고정활성과 생육특성의 계절변화)

  • Song, Seung-Dal;Bae, Sang-Mee
    • The Korean Journal of Ecology
    • /
    • v.15 no.4
    • /
    • pp.377-386
    • /
    • 1992
  • Seasonal changes of symbiotic nitrogen-fixation activity and growth characteristics of four different natural populations of kummerowia striata were quantitatively analyzed during the growing period. the nitrogen-fixation activity of root nodules attained the maximum rates of 148, 132, 102 and 100$\muM\;C_2H_4\;\cdot\;g\;fw\;nodule^{-1}\;\cdot\;hr^{-1}$, respectively for sunny, multibranched, shade and unibranched populations at the optimum growth conditions. and the seasonal changes showed fluctuations by environmental conditions such as light, temperature, nutrient contents, water stress and plant ages, etc. The multibranched plant showed the greater amount of leaf and root nodule biomass, and the higher nitrogenase activity than the unibranched plant. the optimum conditions of leaf chloropht11 and water content of each organ indicated the active growth and the maximum fresh biomass of 4 different populations were 1.92, 1.85, 0.97 and 0.56 g $fw\cdotplant^{-1}$ for shade multibranched, sunny and unibranched populations, respectively.

  • PDF

Vehicle dynamic behavior comparison between two different constraining methods on a chassis dynamometer (차대 동력계에서 자동차 구속조건에 따른 거동 특성 비교)

  • Kang, Yeon Jun;Kim, Heesoo;Song, David P.;Min, Dongwoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.1000-1003
    • /
    • 2014
  • The primary purpose of this study is to observe the dynamic behavior within a vehicle on chassis dynamometer throughout cleat impact testing with two different constraining setups (Tie-down strap and one point fixation). Throughout this empirical experiment, no outstanding dynamic behavior characteristics are observed between two setups and thus, the performance of the one point fixation device is validated. Neither the interior noise nor acceleration at driver seat rail and knuckle is heavily influenced by two different constraining methods. However, one point fixation is far more advantageous considering its shorter set up time and its capability of measuring traction force with its built in force sensor.

  • PDF

Fixation of $\gamma$-Radionuclides by the PVA-PMAA System

  • Won, Hui-Jun;Ahn, Byung-Gil;Jung, Chong-Hun;Kim, Gye-Nam;Oh, Won-Zin
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.205-213
    • /
    • 2000
  • A series of laboratory experiments was conducted to investigate the fixation characteristics of poly(vinylalcohol)-poly(methacrylic acid)(PVA-PMAA) mixed solution on the soluble ${\gamma}$- radionuclides. Using the potentiometric titration technique, it was found out that the PVA and PMAA in a solution form intermacromolecular complex. The mobilized portion of each radionuclide by water from sand surface treated with a fixative was measured by ${\gamma}$-ray spectroscopy. The mobilized portion of minor radionuclides such as 241Am, 154Eu, 155Eu and 144Ce were higher than those of 134Cs and 137Cs. The capability of PVA-PMAA system was better among the candidate solutions for the fixation of total ${\gamma}$-radioactivity. 134,137Cs which is composed of more than 85 % of total ${\gamma}$-radioactivity could be fixed effectively by the PVA-PMAA solution.

  • PDF

The Result of Open Reduction and Fixation in Sternal Fracture with Displacement (흉골 전위골절에 대한 수술적 정복고정술의 결과)

  • Kim, Young-Jin;Cho, Hyun-Min
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.175-179
    • /
    • 2010
  • Purpose: Sternal fractures after blunt thoracic trauma can cause significant pain and disability. They are relatively uncommon as a result of direct trauma to the sternum and open reduction is reserved for those with debilitating pain and fracture displacement. We reviewed consecutive 11 cases of open reduction and fixation of sternum and tried to find standard approach to the traumatic sternal fractures with severe displacement. Methods: From December 2008 to August 2010, the medical records of 11 patients who underwent surgical reduction and fixation of sternum for sternal fractures with severe displacement were reviewed. We investigated patients' characteristics, chest trauma, associated other injuries, type of open reduction and fixation, combined operations, preoerative ventilator support and postoperative complications. Results: The mean patient age was 59.3years (range, 41~79). The group comprised 6 male and 5 female subjects. Among 11 patients who underwent open reduction and fixation for sternal fracture with severe displacement, 6 cases had isolated sternal fractures and the other 5 patients had associated other injuries. Sternal fractures were caused by car accidents (9/11, 81.8%), falling down (1/11, 9.1%) and direct blunt trauma to the sternum (1/11, 9.1%), respectively. 3 of the 7 patients (42.9%) who underwent sternal plating with longitudinal plates showed loosening of fixation. Otherwise, none of the 4 patients who underwent surgical fixation using T-shaped plate had stable alignment of the fracture. Conclusion: Sternal fractures with severe displacement need to be repaired to prevent chronic pain, instability of the anterior chest wall, deformity of the sternum, and even kyphosis. In the present study, a T-shaped plate with a compression-tension mechanism constitutes the treatment of choice for displaced sternal fractures.

Biological Fixation of $CO_2$ by Chlorella sp. HA-1 in a Semi-Continuous and Series Reactor System

  • LEE JAE-YOUNG;KWON TAE-SOON;BAEK KITAE;YANG JI-WON
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.3
    • /
    • pp.461-465
    • /
    • 2005
  • Characteristics of biological $CO_2$ fixation by Chlorella sp. HA-1 were investigated in a semi-continuous and series reactor system using an internally illuminated photobioreactor to overcome shortcomings of physicochemical technologies such as adsorption and membrane separation. High $CO_2$ fixation rate was achieved in the semi-continuous reactor system, in which the dilution ratios of the culture medium were controlled. The average $CO_2$ fixation rate was maintained almost constantly when the dilution ratio increased by 0.1 increment from the initial value of 0.5. The total removal efficiency of $CO_2$ was enhanced by employing a series reactor system. The average $CO_2$ fixation rate increased until 4.013 g $CO_2\;day^{-1}$ in a series operation of four reactors, compared to 0.986 g $CO_2\;day^{-1}$ in a batch operation mode. The total $CO_2$ fixation rate was proportional to the number of reactors used in the series reactor system. In the series reactor system of semi-continuous operation, a large amount of $CO_2$ was removed continuously for 30 days. These results showed that the present reactor systems are efficient and economically feasible for a biological $CO_2$ fixation.

The Gender Observation Time Characteristics from Sight Fixation and the Leap of Pupil Index (시선의 고정과 도약 동공지표에 나타난 성별 주시시간 특성)

  • Lee, Jeong Ho;Kim, Jong-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.1
    • /
    • pp.29-38
    • /
    • 2018
  • This research is to analyze the change of pupil size in gender through the eye-tracking experiment in large complex cultural space. It is meaningful that figured out the common characteristics and differences from gender observation characteristics. Through this research, the analyzed results of the observation time measurement that appeared from the fixation and saccades pupil indicator able to define as follows. Firstly, it was suggested that there were differences between each gender and participants through extract pupil size that can be the standard examples for the case from male and female and the process of extracting the relative pupil size change on the hourly range. From the specific time range, it was possible to indicate bending characteristics and reversal phenomena of Fixation and Saccades. Second, the result was found equally from both male and female group that the rapid increment of pupil size at initial time range immediately after the eye-tracking experiment has been initiated. This can be considered to actively accepting the stress given by the subject through the extended pupil after 10 seconds that compare to indicated very low pupil size between 0 to 10 seconds after starting the experiment. Third, meanwhile 0 to 10 seconds after initial observation are the time of sudden change in the pupil size, therefore these time range data cannot be regarded as observed in the appropriate condition. Thus, it able to define the highest times of emotional processing for male as 10 to 80 seconds, and for female as 10 to 70 seconds. There was no definition of the time range data for observation experiment from previous research, this data can be considered to stable time to observation through the pupil extension. Therefore, it is possible to set suitable time of observation experiment to be around 70 to 80 seconds exclude initial experiment time.

Microwave fixation of Setaria Digitata for scanning electron microscopy (선충류의 주사전자현미경적 관찰을 위한 마이크로웨이브 고정법)

  • Lee, San-Soo;Cho, Kyoung-Oh;Shin, Kil-Sang;Shin, Sung-Shik
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.2
    • /
    • pp.203-207
    • /
    • 2007
  • Conventional processing of biological materials including nematode parasites for scanning electron microscopy includes fixation with glutaraldehyde and osmium, followed by dehydration in an ascending grade of ethanol, and finally freeze drying. This procedure takes about 8 to 12 h depending on the characteristics of samples. Microwave irradiation of 2,450 MHz enhance the action of cross-linking fixatives and can greatly accelerate various stages of tissue processing. In this study, samples of nematode parasites, Setaria digitata, were fixed by a combination of conventional chemical fixation and the microwave irradiation during the process. The microwave irradiation was also incorporated in the serial dehydration process with ethanol. The complete procedure from the initial fixation to the completion of dehydration with ethanol was reduced to 1 h with good preservation of the ultrastructural details of the specimens.

The Use of Special Washers in Bone Plates for Improved Impact-Absorbing Characteristics (충격흡수 특성의 향상을 위하 내고정용 특수 와셔에 관한 연구)

  • 김윤영;김장수
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.457-462
    • /
    • 1995
  • Unlike the usual bone plate and screw fracture fixation, an improved plate fixation method, which can transfer gradually physiological load to bones, is described. The key feature of the present method is to use washers between the plate and the screw. Bio-absorbable materials or non-ferrous materials with good damping characteristics are used to manufacture the washers. The purpose of this paper is to discuss potential advantages of the proposed method, and to show experimentally its improved impact-absorbing characteristics. Vibration experiments are carried out for pig femurs and cow tibias with and without the proposed washers. This experiments show that the washers can drop the first peak value suite substantially in the FRF plots. Although in-vivo experiments have not been conducted, the present fixation method appears to be a simple and effective alternative to the presently used method.

  • PDF

Analysis of Sternal Fixation Results According to Plate Type in Sternal Fracture

  • Byun, Chun Sung;Park, Il Hwan;Hwang, Wan Jin;Lee, Yeiwon;Cho, Hyun Min
    • Journal of Chest Surgery
    • /
    • v.49 no.5
    • /
    • pp.361-365
    • /
    • 2016
  • Background: Sternal fractures are relatively rare, and caused mainly by blunt anterior chest wall trauma. In most cases, sternal fractures are treated conservatively. However, if the patient exhibits problematic symptoms such as intractable chest wall pain or bony crepitus due to sternal instability, surgical correction is indicated. But no consensus exists regarding the most appropriate surgical method. We analyzed the results of surgical fixation in cases of sternal fracture in order to identify which surgical method led to the best outcomes. Methods: We retrospectively reviewed the medical records of patients with sternal fractures from December 2008 to December 2011, and found 19 patients who underwent open reduction and internal fixation of the sternum with a longitudinal plate (L-group) or a T-shaped plate (T-group). We investigated patients' characteristics, clinical details regarding each case of chest trauma, the presence of other associated injuries, the type of open reduction and fixation, whether a combined operation was performed, and postoperative complications. Results: Of the 19 patients, 10 patients (52.6%) were male, and their average age was 56.8 years (range, 32 to 82 years). Seven patients (36.8%) had isolated sternal fractures, while 12 (63.2%) had other associated injuries. Seven patients (36.8%) were in the L-group and 12 patients (63.2%) were in the T-group. Three patients in the L-group (42.9%) showed a loosening of the fixation. In all patients in the T-group, the fracture exhibited stable alignment. Conclusion: Open reduction and internal fixation with a T-shaped plate in sternal fractures is a safer and more efficient treatment method than treatment with a longitudinal plate, especially in patients with a severely displaced sternum or anterior flail chest, than a longitudinal plate.