• 제목/요약/키워드: five-phase induction motor

검색결과 38건 처리시간 0.034초

포화성분을 고려한 3상 유도전동기 리액터 기동 특성 분석 (Characteristics Analysis for Reactor Starting Method of 3-Phase Induction Motor Considering Saturation)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.65-70
    • /
    • 2012
  • Induction motor is the most widely used to obtain the driving force in the industrial site. Induction motor generates a high current at startup. Most of starting currents are often more than five times of rated current. This high starting current can cause problems such as the voltage drop in the system. In order to solve these problems, if the motor capacity is large, generally we use reactor starting method rather than direct on line starting method. When a high startup current passes through reactor, reactor can serve as a nonlinear elements. In this study, we analyzed that the current, torque and power of the induction motor are different from the change of linear and nonlinear components of the reactor magnetic field.

Implementation of Space Vector Two-Arm Modulation for Independent Motor Control Drive Fed by a Five-Leg Inverter

  • Talib, Md Hairul Nizam;Ibrahim, Zulkifilie;Rahim, Nasrudin Abd.;Abu Hasim, Ahmad Shukri
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.115-124
    • /
    • 2014
  • This paper presents the implementation of two-arm modulation (TAM) technique for the independent control of a two-induction motor drive fed by a five-leg inverter (FLI). A carrier-based space vector pulse width modulation technique for TAM is proposed to generate switching signals for FLI. Two independent three-phase space vector modulators are utilized to control two motors. The motor drive system applies two separate indirect field-oriented control methods. The stationary voltage outputs from the vector control are synthesized in the three-phase space vector modulator to generate switching signals for FLI. The performance of the independent control of the motors and the voltage utilization factor are likewise analyzed. Simulation and experimental results verify the effectiveness of the proposed method for the independent control of the two-motor drive system. The proposed technique is successfully validated by dSPACE DS1103 experimental work.

Detection of Incipient Faults in Induction Motors using FIS, ANN and ANFIS Techniques

  • Ballal, Makarand S.;Suryawanshi, Hiralal M.;Mishra, Mahesh K.
    • Journal of Power Electronics
    • /
    • 제8권2호
    • /
    • pp.181-191
    • /
    • 2008
  • The task performed by induction motors grows increasingly complex in modern industry and hence improvements are sought in the field of fault diagnosis. It is essential to diagnose faults at their very inception, as unscheduled machine down time can upset critical dead lines and cause heavy financial losses. Artificial intelligence (AI) techniques have proved their ability in detection of incipient faults in electrical machines. This paper presents an application of AI techniques for the detection of inter-turn insulation and bearing wear faults in single-phase induction motors. The single-phase induction motor is considered a proto type model to create inter-turn insulation and bearing wear faults. The experimental data for motor intake current, rotor speed, stator winding temperature, bearing temperature and noise of the motor under running condition was generated in the laboratory. The different types of fault detectors were developed based upon three different AI techniques. The input parameters for these detectors were varied from two to five sequentially. The comparisons were made and the best fault detector was determined.

Hybrid-Boost Modular Multilevel Converter-Based Medium-Voltage Multiphase Induction Motor Drive for Subsea Applications

  • Daoud, Mohamed;Elserougi, Ahmed;Massoud, Ahmed;Bojoi, Radu;Abdel-Khalik, Ayman;Ahmed, Shehab
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.714-726
    • /
    • 2019
  • This paper proposes a hybrid-boost Modular Multilevel Converter (MMC) for the Medium-Voltage (MV) Variable Speed Drives (VSDs) employed in subsea applications, such as oil and gas recovery. In the presented architecture, a hybrid-boost MMC with a reduced number of semiconductor devices driving a multiphase Induction Machine (IM) is investigated. The stepped output voltage generated by the MMC reduces or eliminates the filtering requirements. Moreover, the boosting capability of the proposed architecture eliminates the need for bulky low-frequency transformers at the converter output terminals. A detailed illustration of the hybrid-boost MMC operation, the expected limitations/constraints, and the voltage balancing technique are presented. A simulation model of the proposed MV hybrid-boost MMC-based five-phase IM drive has been built to investigate the system performance. Finally, a downscaled prototype has been constructed for experimental verification.

5상 1.5kW 농형 유도전동기의 운전특성 (Operating Characteristics of Squirrel-Cage Induction Motor of 5-Phase 1.5kW)

  • 김민회;정형우;송현직
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.52-59
    • /
    • 2014
  • This paper presents an improved operating characteristics of squirrel-cage induction motor(IM) for 5-phase 1.5kW, 220V, 60Hz in order to study a polyphase AC machinery that keep hold of advantages more than traditional three-phase a IM, such as reducing a amplitude of torque pulsation, decreasing electric noises, and increasing the reliability. The developed manufacturing motor was necessary to do improvement of speed regulation, efficiency, operating characteristics, and so on at rated load. There are remake a redesigned and distributed stator winding connection without changing the frames of stator and rotor core in previous established the motor by a repeat tests. There are shown a experiments results of no-load test, locked rotor test, operating characteristics at variable load, FFT analysis of harmonics within output voltages and current waveform, decided motor parameters.

5상 1.5kW 농형 유도전동기 개발 (Development of Squirrel-Cage Induction Motor for 5-Phase 1.5kW)

  • 김민회;정형우;송현직
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.57-68
    • /
    • 2014
  • This paper propose a development of squirrel-cage induction motor(IM) for 5-phase 1.5kW, 220V, 60Hz in order to study a polyphase ac machinery that keep hold of advantages more than traditional three-phase a IM, such as reducing a amplitude of torque pulsation, decreasing electric noises, and increasing the reliability. Designed methods of the motor use a development tools with Maxwell 2D and Simplorer program. There are designed drawing of manufactured frames of the IM. amplitude and waveform of the generated electromotive force, FFT analysis of harmonics within output voltages and current, and reviewing a experiment results are shown by variable output. We are presenting a design and manufacture methods for the 5-phase squirrel-cage IM.

비선형 부하의 운전시 유도전동기의 특성 해석 (Characteristics Analysis of Induction Motor by Operation of Non-lineal Loads)

  • 김종겸;박영진;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.147-153
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.

  • PDF

5상 유도전동기의 파라미터 추정 (A Parameters Estimation of Five-phase Induction Motor)

  • 김남훈;백원식;김민회;정형우;김동희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.55-56
    • /
    • 2010
  • 다상 유도 전동기(Multi phase induction motor)의 고성능 제어를 수행하기 위해서는 정확한 파라미터 계산이 필수적이다. 특히 전동기의 벡터제어(FOC, Field oriented control)나 직접토크제어(DTC, Direct torque control)와 같은 고성능 제어 시스템의 경우, 슬립 계산이나 자속관측기 그리고 PI 제어기 게인 추정에서 전동기 상수들이 필수적으로 사용된다. 본 논문에서는 실험용으로 집중권(Concentrated winding) 구조를 가지는 2kW, 5상 유도전동기를 제작하였으며, 5상 유도전동기 파라미터 추정에 대한 방법을 제시하였다. 일반적으로 다상 유도전동기의 경우 1차 공간 고조파(1st space harmonic) 성분에 대한 파라미터만을 추정하여 제어에 사용하지만, 본 논문에서는 1차 공간 고조파 성분과 3차 공간 고조파(3rd space harmonic) 성분에 대한 파라미터 추정 방법을 제시한다. 결과적으로 제안된 파라미터 추정 방법의 타당성을 확인하기 위해서 설계값과 실험값을 비교하였다.

  • PDF

단상 유도전동기의 무부하손실을 고려한 등가회로 정수의 결정 (Determination of Parameters of Equivalent Circuit Taking No-Load Losses Into Account for Single-Phase Induction Motors)

  • 좌종근;김도진
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.358-363
    • /
    • 2010
  • This paper proposes a step-by-step method of determining the parameters of equivalent circuit which is considered the no load losses for the single phase induction motor which has the starting winding. This method is comprised of three steps, and the stator resistance which is measured by the method of voltage drop is treated as constant and the stator and the rotor leakage reactances are assumed to be the same in every step. The test results of no load and locked rotor test are used in the 1st and 2nd step, and the ratings of name plate of the motor are needed in the 3rd step. In the 1st step, the traditional equivalent circuit parameters are directly calculated by no load and locked rotor conditions. In the next step, five nonlinear simultaneous equations for five unknown parameters can be set up by no load and locked rotor equivalent circuits. These equations are solved by using the initial parameters obtained by the 1st step parameters. In the final step, three nonlinear simultaneous equations for rotor winding resistance, leakage reactance and no load losses component resistance can be set up by equivalent circuit under the rated operation. Three parameters are solved by using the 2nd step parameters. Thus, equivalent circuit parameters are gradually refined step by step. The validity of the proposed method is evaluated by comparing the computed values obtained by the equivalent circuit parameters with the experimental values of the load test.

철도차량 추진시스템을 위한 FLI(Five-leg Inverter)의 성능 분석 (Performance Analysis of a Five-leg Inverter for the Train Propulsion System)

  • 임영설;신덕호;이준석;이교범
    • 한국철도학회논문집
    • /
    • 제20권1호
    • /
    • pp.43-54
    • /
    • 2017
  • 본 논문에서는 철도차량 추진시스템을 위한 3-레그 인버터와 5-레그 인버터의 성능을 비교/분석하고 철도차량에 5-레그 인버터를 적용함에 있어 최적의 동작 조건을 제시한다. 5-레그 인버터는 두 대의 3-레그 인버터에 비해 2개의 스위치가 감소되며, 하나의 제어보드로 두 대의 3상 전동기를 독립적으로 제어할 수 있다. 이로 인해 두 대의 3-레그 인버터를 이용할 경우보다 시스템의 비용 감소와 소형화가 가능하다. 본 논문에서는 먼저 도시철도 차량에서 사용중인 유도전동기 제어 기법과 PWM 방법을 분석한다. 다음으로 5-레그 인버터의 기본 동작과 특징을 분석한다. 이러한 분석을 바탕으로 동일한 유도전동기 제어 기법과 PWM 방법을 3-레그 인버터와 5-레그 인버터에 적용했을 때 유도전동기의 속도와 토크 특성을 비교하고 분석한다.