• 제목/요약/키워드: fitting test

검색결과 596건 처리시간 0.023초

Local Influence Analysis of the Equicorrelation Model

  • Kim, Myung-Geun;Jung, Kang-Mo
    • Journal of the Korean Statistical Society
    • /
    • 제31권4호
    • /
    • pp.447-458
    • /
    • 2002
  • The influence of observations in the equicorrelation model is investigated using the local influence approach when all parameters or subsets of parameters are of interest. When a parameter of interest is scalar, an analytical form of the local influence measure can be found. We will derive a measure for identifying observations that have a large influence on the test of fitting the equicorrelation model. An example is given for illustration.

최적시행함수 Petrov-Galerkin 방법 (Optimal Test Function Petrov-Galerkin Method)

  • 최성욱
    • 한국수자원학회논문집
    • /
    • 제31권5호
    • /
    • pp.599-612
    • /
    • 1998
  • 수송방정식의 양면적은 특성으로 인하여 이송항이 지배적인 흐름에 있어서 수송방정식의 수채해석은 매우 난해하다. 특히 유한요소법을 사용하여 수치해석할 때, 상류방향으로 더 많은 가중치를 두기 위하여 변화된 시행함수를 사용한다. 이러한 방법을 Petrov-Galerkin 방법이라고 한다. 본 논문에서는 N+1 과 N+2 Petrov-Galerkin 방법을 격자 Peclet 수가 큰 수송문제에 적용하였다. 주파수맞춤 기법을 사용하여 N+2 Petrov- Galerkin 방법을 격자 Peclet 수가 큰 소송문제에 적용하였다. 주파수맞춤 기법을 사용하여 N+2 Petrov-Galerkin 방법의 적정 풍상정도를 찾아내었고, 그 결과를 토의하였다. 이 기법의 시행함수는 이송항과 확산항의 상대적 크기에 따라 그 모양이 변화된다. 수치실험을 통하여 제시된 새로운 수치해석기법의 우수성을 설명하였다.

  • PDF

In Search of a Performing Seal: Rethinking the Design of Tight-Fitting Respiratory Protective Equipment Facepieces for Users With Facial Hair

  • Meadwell, James;Paxman-Clarke, Lee;Terris, David;Ford, Peter
    • Safety and Health at Work
    • /
    • 제10권3호
    • /
    • pp.275-304
    • /
    • 2019
  • Background: Air-purifying, tight-fitting facepieces are examples of respiratory protective equipment and are worn to protect workers from potentially harmful particulate and vapors. Research shows that the presence of facial hair on users' face significantly reduces the efficacy of these devices. This article sets out to establish if an acceptable seal could be achieved between facial hair and the facepiece. The team also created and investigated a low-cost "pressure testing" method for assessing the efficacy of a seal to be used during the early design process for a facepiece designed to overcome the facial hair issue. Methods: Nine new designs for face mask seals were prototyped as flat samples. A researcher developed a test rig, and a test protocol was used to evaluate the efficacy of the new seal designs against facial hair. Six of the seal designs were also tested using a version of the conventional fit test. The results were compared with those of the researcher-developed test to look for a correlation between the two test methods. Results: None of the seals performed any better against facial hair than a typical, commercially available facepiece. The pressure testing method devised by the researchers performed well but was not as robust as the fit factor testing. Conclusion: The results show that sealing against facial hair is extremely problematic unless an excessive force is applied to the facepiece's seal area pushing it against the face. The means of pressure testing devised by the researchers could be seen as a low-cost technique to be used at the early stages of a the design process, before fit testing is viable.

호흡기보호구의 밀착계수와 안면구조의 관계 (Correlation of Fit Factors for Respirators and Anthropometric Dimension)

  • 한돈희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제31권3호
    • /
    • pp.440-448
    • /
    • 1998
  • In many developed countries, for example, USA, respirator fit testing is required before entering specific work environment to ensure that the respirator worn satisfies a minimum of fit and that the user knows when the respirator fits properly. Unfortunately because we have not fit test regulation in Korea, a lot of workers wearing respirators may be potentially exposed to hazards. This study was conducted to evaluate the fitting performance for respirators and correlation fit factors with facial dimensions of wearers. 110 subjects (70 males, 40 females) were fit tested for three quarter masks, i.e., two domestic-made Mask 2, and Y and one foreign-made Mask T using PortaCount 8020. A facial dimension survey of the same subjects was conducted to develop a facial dimension grids fer correlation fit factors with facial dimension parameters. A facial dimension grid was developed on the basis of face length and lip length for quarter masks. The results obtained were as follows : 1 Fit factors of Mask T were much higher than those of Masks Z, and Y. 2. Males were fitted more properly than females. 3. Male in box 'f' of grid would be adequately fitted Mask Y and male in box 'b', 'e', 'f', 'h' of grid would be sufficiently fitted Mask T. Female in box 'h' of grid may have a good fitting performance for both Mask Y, and T. But subjects in all boxes of grid would be inadequately fitted Mask Z.

  • PDF

연직드레인 공법에 의한 연약지반의 압밀거동 (Consolidation Behavior of Soft Ground by prefabricated Vertical Drains)

  • 이달원
    • 한국농공학회지
    • /
    • 제42권5호
    • /
    • pp.133-143
    • /
    • 2000
  • A large scale field test of prefabricated vertical drains was performed to anayze the effect of parameters of the very soft clay at a test site. compression index and the coefficient of horizontal consolidation obtained by back-analysis of settlement data were compared with those obtained by means of laboratory tests. Hyperbolic method, Asaoka meoth and curve fitting method were used to compute final settlement of coefficient of consolidation. The relationships of settlement measurement(Sm) versus design settlement(St) and the measurement consolidation ratio(Um) versus design consolidation (Ut) were shown as Sm=(1.0~1.1) St , Um=(1.13~1.17) Ut at 1.0m spacing of drain and Sm=(0.7~0.8)St, Um= (0.92~0.99) Ut at 1.5 m spacing of drain, respectively . The relationships of the field compression index(CcField) and virgin compression index(vcc lab) were shown as Ccfield =(1.0~1.2)vcc lab . But it was nearly within the same range when considering the error factor with the determination method of virgin compression index and the prediction back-analysis of the settlement data was larger than the coefficient of vertical consolidation, and the ratio of consolidation coefficient (Ch/Cv) was Ch =(2.4~2.9) Cv , Ch=(3.4~4.2) Cv at 1.0m and 1.5m spacing of drain, respectively.

  • PDF

아동복 치수 인지도와 맞음새 조사 -학령 전기 아동을 대상으로 - (A Study on Fitness and Awareness of Sizing System of Kids' Clothes - Focusing on a first to third year kids in Elementary School -)

  • 김인숙;석혜정;방은영;김유미;성은주;김덕하;이은진
    • 대한가정학회지
    • /
    • 제40권12호
    • /
    • pp.119-129
    • /
    • 2002
  • This research aims at finding out situation on purchasing clothes for kids, size recognition and fitting to provide basic data in order to establish standard sizes for kids' clothes. A survey was conducted to 360 mothers who have children ranging from first to third grade in elementary school on clothes purchasing method, wearing situation, criteria in deciding size and fitting preference. In terms of data analysis, frequency, percentage, mean, $X^2$-test, ANOVA and Duncan-test were used via SPSS PC program. The result is as follows; 1. While the recognition on brand was high, the recognition on body size was low: as a result, it is believed that it would be effective to mark the weight along with the brand. 2. Many times, they would select one or two size bigger on all items and they would go for a regular or one that fits as far as filling is concerned showing that it is different from adult clothes. 3. As far as obese kids, they would choose based on the diameter, so the diameter item is right but they are too long in general. The length question should be given special attention when manufacturing clothes for obese kids.

Comparison Research on the Ease of Fitted Dress Shirt Patterns

  • Lee, Eunhae;Park, Sanghee
    • 패션비즈니스
    • /
    • 제18권3호
    • /
    • pp.91-103
    • /
    • 2014
  • Shirts which have been a inner-wear in men's suit in the past, are being changed into an item that 20's men utilize to their individuality. Dress shirts have gotten out of its shape, becoming tight and slim with activity and fashion trend. In this study, two patterns of fitted dress shirts in a clothing construction text book were compared with the pattern of an apparel company with regard to the size tolerance and appearance silhouette; this comparison was performed through a fitting test and an appearance evaluation. According to the study, size tolerance of chest girth and waist girth were about 6~8cm and 10~18cm, respectively. Neck girth of the collar was tight in both the fitting test and appearance evaluation. Thus, the measurement value of the neck base girth had to be used for the collar pattern making. Moreover, approximately 35cm is a moderate size for the width on the upper arm in sleeve. Therefor the factors such as size tolerance of waist girth, height of sleeve cap, slim sleeve width and measurement value of neck base girth are being considered for the pattern making of fitted dress shirts.

소형 위성 발사체 2단부 모드 시험 (Modal Test of the 2nd Stage of Small Launch Vehicle)

  • 서상현;정호경;윤세현;박순홍;장영순
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.258-261
    • /
    • 2006
  • The structure of small launch vehicle can be divided into engine section and payload section. This paper introduces modal test of the payload section of small launch vehicle which is composed to satellite, PLA (Payload Adapter), VEB (Vehicle Equipment Bay), KMS (Kick Motor Support) and KM (Kick Motor). From this test, dynamic properties of the 2nd stage structure of small launch vehicle can be obtained. In this test, to simulate free-free boundary condition, test object was hung by 4 bungee cords and excited by using impact hammer Modal test data are analyzed by using TDAS(Test Data Analysis Software). As the result, modal parameters and mode shapes below 100Hz of the 2nd stage of small launch vehicle were identified.

  • PDF

전자기 과도현상 해석을 위한 주파수 의존 시스템 등가 (Frequency Dependent Network Equivalent for Electromagnetic Transient Studies)

  • 왕용필;조금식
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1549-1555
    • /
    • 2007
  • The complexity of modern power systems often makes it impractical to model it in its entirety for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). The advantage of using z-domain fitting is that it can be directly implemented in a digital simulation program without any loss of accuracy. Fitting in the s-domain always requires "discretizing" a continuous system and the inherent approximations. This paper presents z-domain rational function formulation and demonstrates the use of it for the assessment of the transient response of the Lower South Island of New Zealand. Moreover by using a well publicized test system and providing complete information on the developed FDNE coefficients other researchers easily benchmark their work against this.

회전체 진동 감소를 위한 마그네틱 댐퍼의 설계 및 응용 (Design and Application of Magnetic Damper for Reducing Rotor Vibration)

  • 김영배;이형복;이봉기
    • 대한기계학회논문집A
    • /
    • 제24권2호
    • /
    • pp.355-361
    • /
    • 2000
  • In this study, active control magnetic actuator for reducing vibration of rotor system is performed. Identification, modeling, simulation, control system design, and evaluation of active magnetic damper system have been researched. Power amplifier modeling, connected magnetic actuator and augmented by system identification, is included to establish a magnetic damper simulation which provides close performance correspondence to the physical plant. A magnetic actuator, digital controller using DSP(Digital Signal Processor), and bipolar operational power supply/amplifiers are developed to show the effectiveness of reducing rotor vibration. Also the curve fitting procedure to obtain the transfer function of frequency dependent components is developed. Two kinds of test are executed as sliding and oil bearing. Results presented in this paper will provide a well-defined technical parameters in designing magnetic damper system for the proposed rotor.