• Title/Summary/Keyword: first control flow rate

검색결과 156건 처리시간 0.028초

압력제어용 직동 밸브를 이용한 전기.유압 서보시스템의 힘 제어 (Force Control of Electro-Hydraulic Servo System using Direct Drive Valve for Pressure Control)

  • 이창돈;이진걸
    • 유공압시스템학회논문집
    • /
    • 제1권3호
    • /
    • pp.14-19
    • /
    • 2004
  • The Direct Drive Valve used in this study contains a pressure-feedback-loop in itself, then it can eliminate nonlinearity such as the square-root-term in flow rate calculation and the change of bulk modulus of hydraulic oil. In this study, assuming that the dynamic characteristic of the DDV is modelled as a first order lag system, an parameter identification method using the input data and the output data is applied to obtain DDV's mathematical model. Then, a state feedback controller was designed to implement the force control of hydraulic system, and the control performance was evaluated.

  • PDF

Full Scale Testing of the Effect of Stairwell Pressurization on Pressure Differential and Flow Velocity

  • Son, Bong-Sae;Park, Kyung-Hwan;Chang, Young-Bae
    • 한국방재학회 논문집
    • /
    • 제11권3호
    • /
    • pp.83-89
    • /
    • 2011
  • 계단실을 직접 가압했을 경우에 계단실과 부속실 사이의 차압 및 부속실과 세대 사이의 차압이 어떤 영향을 받는지 연구하기 위해 실건물을 사용해 실험했다. 또한 열린문에서의 유속분포도 측정하였다. 본 연구에 사용된 건물은 지상 20층 지하 2층의 공동주택이다. 계단실을 가압하기 위해서 송풍기를 지하 1층에 설치하여 외부공기를 계단실로 공급했다. 13가지 경우에 대한 실험을 실시했으면 주 실험변수들은 문이 개방된 층의 숫자와 위치 및 송풍량이었다. 지상 1층 문들만이 열린 상태에서는 계단실과 부속실 사이의 차압 및 부속실과 세대 사이의 차압이, 1층 부근을 제외하고는, 비교적 균일하게 분포되었다. 실험결과 180~270 CMM에서 한 층이 개방되어도 화재안전기준의 방연풍속을 만족하였고, 계단실은 전체적으로 양압을 유지할 수 있었으나 최소차압 조건(10 Pa)을 항상 만족시키지는 못하였다. 두 층의 문들이 개방된 경우, 유량을 증가함으로써 최소유속조건은 만족시킬 수 있었으나 가압지점 인근에서 과압이 발생하지 않는 상태에서 최소차압조건을 만족시키는 것은 비현실적임을 발견했다.

도시고속도로 가변속도제어 운영방안과 효과분석 (A Study on Operation Technique and Effective Analysis of Expressway Variable Speed Limits Control)

  • 임관수;남두희
    • 대한교통학회지
    • /
    • 제29권2호
    • /
    • pp.7-14
    • /
    • 2011
  • 본선 교통류 제어 방안 중 가변속도제어 모형을 제시하고 서울 내부순환로를 중심으로 효과를 검증하였다. 차량 검지기로부터 수집된 데이터 보정 및 평활화 수행후 패턴분석을 통해 도시고속도로의 평일 상태를 4가지로 분류하고 중심 값을 산출하였다. 그리고 분석단위의 상태를 판단하기 위한 상태변수로 전이교통량, 평균밀도, 평균속도를 설정하였으며 제시된 모형과 시나리오에 근거하여 검증한 결과 안전성 및 효율성을 향상시킬 수 있었다. 또한 유입교통량에 따라 가변속도제어의 감속 정도와 유효 적용시간을 산출하였다.

밸브리스 압전펌프 연동구동 제어기 설계 (Design of Multi-Phase Shift Controller for Valveless PZT Pump)

  • 조정대;박경민;노종호;함영복;유진산
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1282-1285
    • /
    • 2004
  • The high voltage driving system with multi-phase shifter including piezoelectric actuators comprised a driving power unit for outputting the driving power by converting input alternate current into direct current, a frequency shifting unit for supplying the direct current power and shifting or generating a frequency, a high-voltage amplification unit for amplifying the input signal outputted from the driving power unit and the frequency shifting unit into a high-voltage signal, and a phase shifting unit for shifting the phase difference of the amplified signal applied to the high-voltage amplification unit and driving plural piezoelectric actuators sequentially. The results that the operating voltage was stable, the voltage loss ratio was low and the response velocity was fast could be obtained. An experiment on performance of the high voltage driving system with multi-phase shifter designed and manufactured as above described was conducted by using a piezoelectric pump having 3 sheets of round unimorph piezoelectric actuators laminated respectively in a rectangular case. It sucks any fluid by causing the first piezoelectric actuator to shift from the inlet porter side, the phase delay of 60$^{\circ}$ causes the second piezoelectric actuator to begin to shift, and the phase delay of 120$^{\circ}$ causes the third piezoelectric actuator to begin to shift. As a result of measuring each change in the outlet flow rate of the piezoelectric pump, it was shown that the frequency-flow rate characteristic, the voltage-flow characteristic, and the load pressure-flow rate characteristic were improved.

  • PDF

Goethite의 합성 및 형상제어 (Synthesis and Shape Control of Goethite Nano Particles)

  • 최현빈;전명표;전승엽;황진아
    • 한국전기전자재료학회논문지
    • /
    • 제29권9호
    • /
    • pp.552-558
    • /
    • 2016
  • Goethite, ${\alpha}$-FeOOH have various applications such as absorbent, pigment and source for magnetic materials. Goethite particles were synthesized in a two step process, where $Fe(OH)_2$ were synthesized in nitrogen atmosphere using $FeSO_4$ as a raw material in the first process, and after that acicular goethite particles were obtained in an air oxidation process of $Fe(OH)_2$ in highly alkaline aqueous solution. Their phase and microstructure were investigated with XRD and FE-SEM. It was found that the morphology of goethite and the ratio of length-to-width (aspect ratio) of acicular goethite are dependent on the some factors such as R value ($OH^-/Fe^{2+}$), air flow rate and pH conditions. In particular, R value has the strongest influence on the synthesized goethite morphology. It is considered that the optimal value R is 4.5 because X-ray diffraction peaks of goethite have the highest intensity at that value. Morphology of goethite particles was controlled by air flow rates, showing that their size and aspect ratio are getting smaller and decrease, respectively as air flow rate increases. The largest goethite particle obtained is about 1,500 nm in length and 150 nm in diameter.

외부식 다단형 슬로트 후드의 효율 향상에 관한 연구 (A Study on Improvement of Ventilation Efficiency of Multi-Stage Slot Hood)

  • 김현석;백남원
    • 한국산업보건학회지
    • /
    • 제3권2호
    • /
    • pp.204-212
    • /
    • 1993
  • This study was conducted to evaluate ventilation efficiency of 4-stage slot hood by variation of slot width, flow rate, hood size and baffle size. The slot velocity, control velocity and plenum velocity were related to slot width and the distance between source of contamination and hood. The results obtained from laboratory experiment for local exhaust ventilation systems were as follows ; 1. When slot widths were constant(equally changed) and the velocity was 6-10 m/s, the slot velocity from 1st slot to 4th slot gradually decreased. As the slot width-to-slot length ratio(WLR) decreased, the slot velocity of each stage increased. But if WLR value was less than 0.04, the slot velocity decreased. 2. When slot velocity exceeded 10 m/s with constant slot widths, the slot velocity of each stage was uniform. 3. When the slot velocity was uniform within 10 m/s and the first slot width was 14-20 mm, the slot width ratio between 1st slot and each of three other slots were 1, 1.25, 1.5 and 3.0, respectively. 4. The slot and plenum velocity were uniform when exhaust flow rate changed from 14 to $19m^3/min$ and there were no hood splitter vanes. 5. When the slot velocity at each stage was uniform, the control velocity at site 30 cm away from hood No.2 increased from 0.15-0.30 to 0.25-0.45 m/s and the control distance from 20 to 30 cm(about 1.5 times).

  • PDF

빠르게 전개되는 스포일러의 비정상 유동해석 (Unsteady Flow Computation of a ]Rapidly Deploying Spoiler)

  • 최성욱;장근식
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2000년도 춘계 학술대회논문집
    • /
    • pp.127-139
    • /
    • 2000
  • Transient aerodynamic response of an airfoil to a rapidly deploying spoiler is numerically investigated using a two-dimensional turbulent compressible Navier-Stokes flow model. The spoiler moving relative to a stationary airfoil is treated by an overset grid bounded by a 'dynamic domain-dividing line' the concept of which is developed first..in this paper. The fluid-dynamic mechanism of the adverse lift due to the rapidly deploying spoiler is analyzed. Also the effect of spoiler deploying rate on the initial behavior of the aerodynamic response is expounded, which is of interest in view of active control technology and controller design for the spoiler. The results of present computation about the stationary as well as moving spoilers are relatively in good agreement with the existing experimental data.

  • PDF

Role of gas flow rate during etching of hard-mask layer to extreme ultra-violet resist in dual-frequency capacitively coupled plasmas

  • 권봉수;이정훈;이내응
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.132-132
    • /
    • 2010
  • In the nano-scale Si processing, patterning processes based on multilevel resist structures becoming more critical due to continuously decreasing resist thickness and feature size. In particular, highly selective etching of the first dielectric layer with resist patterns are great importance. In this work, process window for the infinitely high etch selectivity of silicon oxynitride (SiON) layers and silicon nitride (Si3N4) with EUV resist was investigated during etching of SiON/EUV resist and Si3N4/EUV resist in a CH2F2/N2/Ar dual-frequency superimposed capacitive coupled plasma (DFS-CCP) by varying the process parameters, such as the CH2F2 and N2 flow ratio and low-frequency source power (PLF). It was found that the CH2F2/N2 flow ratio was found to play a critical role in determining the process window for ultra high etch selectivity, due to the differences in change of the degree of polymerization on SiON, Si3N4, and EUV resist. Control of N2 flow ratio gave the possibility of obtaining the ultra high etch selectivity by keeping the steady-state hydrofluorocarbon layer thickness thin on the SiON and Si3N4 surface due to effective formation of HCN etch by-products and, in turn, in continuous SiON and Si3N4 etching, while the hydrofluorocarbon layer is deposited on the EUV resist surface.

  • PDF

지역난방용 태양열시스템 (Solar District Heating System)

  • 백남춘;이진국;윤응상;윤석만;신우철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.663-668
    • /
    • 2008
  • This study was carried out solar heating system design for district heating and it's the performance analysis by experiment. This experimental system was installed in Bundang district heating area in the end of 2006. The flat plate and vacuum tube solar collector are combined in one system. So district heating water is heated first by flat plate solar collector and than by vacuum tube solar collector. This solar heating system has not a solar buffer tank and is operating with variable flow rate to obtain a setting temperature of $90{\sim}95^{\circ}C$. As a result, the daily solar thermal collection efficiency is about 30 to 40% for the plate type and 50 to 55% for the vacuum tube solar collector. It varied especially depend on the weather condition like as solar radiation and ambient temperature. This variable flow rate system can be also reduced much pumping power more than 50%.

  • PDF

강제배기를 이용한 굴삭기 공기조화 시스템에 관한 연구 (A Study on Air-Conditioning System for Excavator using Forced Exhaust)

  • 황지현;정찬세;고주현;양순용
    • 드라이브 ㆍ 컨트롤
    • /
    • 제10권2호
    • /
    • pp.23-29
    • /
    • 2013
  • The excavator is used in a variety of construction environments. There are many kinds of risk like falling rocks or harmful dust. The excavator cabin protects the operator not only from these harmful environments but also provides a comfortable working environment. By the way, the excavator cabin consumes a lot of energy for cabin air conditioner. For this reason, the research is required to reduce energy consumption. This study suggests the air conditioning system for excavator using forced exhaust. First, the forced exhaust system simulated by AMESim tool and surveyed the applicability. Using AMESim simulation, it was investigated the effect of cabin inside temperature by intake flow rate and intake air temperature. The experiment executed using the 1.5 ton excavator and field tested according to the intake flow rate. Finally, verified the applicability on the air conditioning system for excavator using forced exhaust.