• 제목/요약/키워드: firing voltage

검색결과 233건 처리시간 0.024초

가스튜-브와 산화아연 바리스터의 PSpice 모델 (A PSpice Model of Gas Tube and ZnO Varistor)

  • 송재용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.150-158
    • /
    • 1999
  • The process of designing protective circuits against damage by transient overvoltages requires much work and expensive equipment. However computer simulation using PSpice can overcome these problems. In this paper a gas tube and a ZnO varistor Pspice-model considering the steepness of the wave-front were presented. The effects of various waveforms on the transient behaviors and firing volt-ages of a gas tube were modeled by controlled voltage source E controlled current source G and TABLE function of PSpice. And the nonlinear characteristics of a ZnO varistor were modeled by controlled voltage source E and H. To estimate the characteristics of the models proposed various waveforms specified in IEC Std. 1000310-4-5 were used in the simulation and the actual tests. The simulation results were compared with test results and showed good agreement.

  • PDF

HVDC 컨버터 시스템에서 라디오 장해에 대한 대책 (Reduction Method of Radio Interference in HVDC Converter System)

  • 김찬기;최순호
    • 전기학회논문지
    • /
    • 제61권6호
    • /
    • pp.833-837
    • /
    • 2012
  • In HVDC System, the rapid voltage breakdown between anodes and cathodes during valve firing causes radio interference in HVDC converter station. These voltage breakdown causes steep current pulse and inject current in system. As a result, harmonic frequencies are generated from valve, switchyard. In this paper, theoretical background of radio interference in HVDC converter is discussed and its reduction method for radio interference is proposed.

Comb형 전극구조를 갖는 AC 플라즈마 디스플레이 패널의 방전특성 (Discharge Properties of an AC Plasma Display Panel with Comb-Type Electrodes)

  • 김동수;장지근;임성규;장호정
    • 한국재료학회지
    • /
    • 제9권2호
    • /
    • pp.195-198
    • /
    • 1999
  • The newly designed Ac-PDP(plasma display panel with comb-type electrode) structure was fabricated by using the screen printing method and the electrical and optical characteristics were measured under the various discharge conditions. The minimum firing voltages measured under pure Ne and Ne+Xe mixture gas with the application of 10 kHz square wave were 190V and 160V, respectively. The firing voltages of the PDP cell with the comb-type electrode were compared with those of the cell with matrix electrode under the same discharge condition. The firing voltage of the PDP cell with comb-type electrode was 15 V lower than that of the PDP cell with conventional matrix electrodes.

  • PDF

대용량 전력변환용 사이리스터 디지털 점호제어 (Digital firing control for high power thyristor converter)

  • 이영복;김장목;임익헌;류호선;송승호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.565-568
    • /
    • 2003
  • The conventional analog-based firing circuit can be implemented by comparing a linearly decreasing periodic sawtooth waveform synchronized to the ac line, with a voltage corresponding to the desired converter delay angle. This circuit requires a large number of components (resistance and capacitor) and careful adjustment of the synchronization circuity In this paper a novel firing circuit is proposed for thyristor switch is elements. The proposed circuit is implemented on the basis of the analog cosine method using FPGA and microprocessor.

  • PDF

ZnO varistor에서의 절연 도포제 및 2차 열처리 효과 (Effect of Insulating Paste and 2nd Firing Process in ZnO Varistor)

  • 이남양;김명식;정인재;오명화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.821-823
    • /
    • 1988
  • The electrical properties of ZnO varistors fabricated by the second firing method were investigated. The nonlinear coefficient of ZnO varistor fabricated by this method is similar to that of commercial ZnO varistor. But the breakdown voltage is higher than that of commercial ZnO varistor. These results are attributed to grain boundary diffusion of $Bi_{2}O_{3}$ by second firing.

  • PDF

A Study on the Adjusting Output Energy of the $CO_2$ Laser Controlled Directly in AC Power Line

  • Noh, Ki-Kyong;Jeong, Jong-Jin;Chung, Hyun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권4호
    • /
    • pp.152-154
    • /
    • 2005
  • We demonstrate a simple $CO_2$ laser by controlling firing angle of a TRIAC switch in ac power line. The power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply does not need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. In order to control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of TRIAC gate is varied from $45^{circ}$ to $135^{circ}$. A ZCS(Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control the gate signal of the TRIAC precisely. The maximum laser output of 40W is obtained at a total pressure of 18 Torr, a pulse repetition rate of 60Hz, and a TRAIC gate firing angle of $90^{circ}$.

펄스파워 기술을 이용한 방전파쇄과정의 전압파형 검출 (Voltage waveform detection of discharge breaking process used pulsed-power technique)

  • 정영환;윤성호;이유수;이동훈;김희제;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2195-2197
    • /
    • 1999
  • Electric breakdown in the liquid produces a spark channel. The energy input into the channel causes expansion of a vapor gas cavity. If the power of the discharge is high enough, this expansion is fast enough to produce a shock wave which propagates through the liquid to the subject of destruction. We focused our attention on the correlation between electric parameters and the characteristics of the flash caused by point to-point electrode discharge in the water. By varying firing voltage and gap length, we obtained the features of the flash : amplitude, pulse width, and so on. In this paper, We have known that there is a concrete interrelation between underwater firing voltage and photodiode output.

  • PDF

AC-PDP 구동에 있어서 V-Q Lissajous' Figure을 이용한 벽전하 거동분석 (Analysis of Wall-charge behavior using V-Q Lissajous' figure in AC-PDP driving)

  • 정종갑;조우성;최창훈;주병권;박선우;김철주;노승용;김영조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.111-115
    • /
    • 2002
  • To understand the discharge characteristics in AC-PDP, it is necessary to study on the wall charge behavior. But, it is difficult to measure the wall charge directly. In this paper, the V-Q Lissajous' figure is used to measure the wall charge indirectly and analyze the wall charge behavior. With the V-Q Lissajous' figure, the discharge characteristics of AC-PDP are studied according to vary driving conditions, such as the frequency, pulse duty ratio, and rising & falling time. As a result, the V-Q Lissajous' figure is used to measure the discharge characteristics of the AC-PDP. It is confirmed that firing initial voltage and firing final voltage for discharge are effected by the aboved variables. Related with the wall voltage generation, it is thought that the difference of the slope at the V-Q Lissajous' figure is caused by charged ions inside the dielectric layer.

  • PDF

순환 전류를 이용한 병렬 연결된 사이리스터 듀얼 컨버터의 불균형 병렬 운전 보상 기법에 관한 연구 (A Study on the Compensation Method for Unbalance Parallel Operation of Parallel Connected Thyristor Dual Converters using Circulating Current)

  • 김성안;한성우;문동옥;김영우;이창희;조윤현
    • 전력전자학회논문지
    • /
    • 제21권6호
    • /
    • pp.473-480
    • /
    • 2016
  • This study proposes a performance improvement for parallel-connected thyristor dual converters using a circulating current with an unbalanced parallel operation compensator. The proposed control method determines a variable reference value for the voltage PI controller according to voltage error at firing angle control applied to a difference current control. This method uses circulating current control to maintain a stable voltage and excellent current response during parallel operation. The effectiveness of the proposed control is verified with a simulation and an experiment based on the comparison of the performance of the proposed control method with other conventional methods.

인버터를 이용한 전기분해전원 설계에 과한 연구 (A Study on the Design of Electrolysis Power Using Inverter)

  • 이정민;목형수;최규하;최동규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.55-59
    • /
    • 1998
  • By this time, Diode Rectifier or SCR has been used to gain DC Voltage for Electrolysis Power. Generally DC Voltage is produced from rectifier shall be transformed before rectifier using step-down transformer to obtain adaptable DC Voltage, rectifier output. In the same way, rectifier using SCR shall obtain output voltage after step-down voltage through transformer and control of the SCR firing angle. Transformer shall be used for this two methods to adjust the voltage. But the size and weight of the transformer are increased in accordance with the increase of capacity, and the hardships are accompanied in workspace or transportation. Besides, only the value of input voltage is possible to be regulated, and the expectation of current control is almost impossible during Electrolysis. This study has conducted Design and Simulation to reduce the size and weight of transformer and to be enable voltage and current control of Electrolysis power through high-speed switching using Inverter, Electronics device.

  • PDF