• 제목/요약/키워드: fire-resistant

검색결과 269건 처리시간 0.025초

강재의 단면형상에 따른 내화피복두께 산정 연구 (Study on the Determination of Fire Protection Thickness based on Section Factor)

  • 정청운;지남용;권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.139-142
    • /
    • 2003
  • Traditionally, the thickness of fire protection materials of structural elements such as beam and column have been decided by fire test using the predominant steel section of $H-300{\times}300{\times}10{\times}15$ for column and $H-400{\times}200{\times}8{\times}13$ for beam in Korea. But this way of determination of fire protection thickness yields very unduly results. Because the temperature-increment rate of structural steel elements depends mainly on magnitude of their cross-areas. In general, the thicker size of cross-areas for structural elements, the lower temperature shows up. It had already proved that the fire protection thickness only depends on the size of cross-areas and the fire protection method for three-fide or four-side exposed conditions in European countries, the United State of America and so on. To demonstrate there would be differences among various cross-areas for structural elements, we conducted several fire tests with full-scale specimens of beams and columns. For the determination of critical temperature for steel section when the fire resistant performance is needed to be decided, we conducted with a loaded fire test for beam and column, respectively. The small column in 1.0 meter length and beam in 1.5 meter length were used in order to deprive the rational fire protection thickness of structural elements such as beam and column, respectively. After test, we could obtain there were significant temperature lass between higher cross-areas and lower cross-areas. The critical temperature of steel as a criterion is used 538$^{\circ}C$ for column and 593$^{\circ}C$ for beam which is from ASTM E 119 because we don't make provisions as critical temperature by elements. We could consider that the best way of determination of fire protection thickness is using the following multi-regression equation which was deprived from several fire tests using the concept of section factor, FR(column) = 0.17 +5191.49t A/Hp + 40.77t, FR(beam) = 0.25 +6899.31t A/Hp + 32.60t(where, FR means fire resistant time, t means thickness, A means cross-area and Hp means heated parameter).

  • PDF

폴리믹스 혼입 고강도 콘크리트의 펌프압송 성상에 관한 실험적 연구 (An Experimental Study on Pumpability Characteristics of High Strength Concrete Mixed Polymix)

  • 이주호;문형재;김정진
    • 콘크리트학회논문집
    • /
    • 제24권5호
    • /
    • pp.509-516
    • /
    • 2012
  • 기존 내화성능 확보기술인 섬유혼입 콘크리트의 경우 내화성능을 높이기 위해 섬유량이 과다하게 투입되면 초고압 펌핑시 엉킴현상이 발생하여 압송효율이 급격히 저하되는 문제점이 있다. 이에 이 연구에서는 기존 섬유 이외에 추가로 유동성 개선효과 및 내화성능을 확보할 수 있는 폭렬방지재를 개발하여 이를 활용한 60~80 MPa 고강도 콘크리트의 펌프압송성능 개선을 이 연구의 목표로 설정하였다. 이 연구에서 사용된 폭렬방지재는 pp섬유, 나일론 섬유 및 폴리머 분말을 혼입한 폴리믹스로서 이를 활용한 결과는 다음과 같다. 섬유혼입 유무에 따른 굳지않은 특성 중 슬럼프 플로우는 섬유투입시 압송 후 기존 대비 약 70% 물성이 개선되었고, 공기량은 섬유혼입에 관계없이 압송 후 다소 증가하였다. 압축강도는 재령 28일에서 설계기준강도를 상회하였고, 휨 강도는 압축강도 발현율 대비 12~15%로 기존 경향과 유사하게 나타났다. 탄성계수는 섬유혼입시 감소하였지만, 기준값 이상으로 문제는 없을 것으로 사료된다.

나노 수산화알루미나를 이용한 건설소재의 내화성능 개선연구 (A Study on Performance of Building Material using nano-hydrated Aluminum for Fire-Resistance)

  • 조병완;박종빈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.826-829
    • /
    • 2004
  • An increasing interest in fire safety engineering can currently be identified in Korea and overseas. The fire-resistant characteristics of spray coating material for fire protection with or without nano $Al(OH)_3$ colloid has been experimentally investigated and the results are presented in this paper. The fire-resistance characteristics of spray coating material with nano $Al(OH)_3$ were superior to those without $Al(OH)_3$. Especially, spray coating material with nano material showed that thermal characteristic in the early days was remarkably excellent.

  • PDF

내화충전구조 인정제도의 성능기준 및 등급분류 개선에 관한 연구 (A Study on the Improvement of Performance Standard and Classification for the Firestop Accreditation System)

  • 이형도;최윤정;안재홍;정아영;서희원;박진오
    • 한국안전학회지
    • /
    • 제35권4호
    • /
    • pp.32-39
    • /
    • 2020
  • The fire compartments with fire-resistant construction are installed in the principal structural parts of a building in order to reduce damage in the event of a building fire. As a fire may spread through a crack in the fire compartment, the firestop with secured performance is used according to the procedure, methods, and standards specified in the detailed operation guideline. According to the current detailed operation guideline, vertical members (wall penetration) and horizontal members (floor penetration) are classified into different categories respective to each other for the classification of the firestop. Therefore, an accreditation applicant must apply for the performance test for each structure even if the wall and the floor have the same structure. Also, Grade T is used for the firestop that penetrates the fire compartment. However, in the case of foreign countries, the use of Grade F for the firestop is allowed even if it penetrates the fire compartment. The result of the precedent studies also showed that there was a significantly low possibility of fire to spread even if Grade F was applied for a metallic duct that penetrated the fire compartment. In this study, the improved scheme for the classification and performance standard of firestops was presented by analyzing the results of precedent studies regarding the firestop and domestic and overseas firestop qualification systems.

Trends of Post-fire Forest Recovery in the South Sikhote-Alin Mountains, Russian Far East

  • Komarova, Tatiana A.;Sibirina, L.A.;Papaik, M.J.;Park, J.H.;Kang, HoSang
    • 한국환경복원기술학회지
    • /
    • 제16권3호
    • /
    • pp.83-95
    • /
    • 2013
  • To understand natural regeneration and stand development after fire in mixed broadleaved-coniferous forests of Sikhote-Alin Mountains, ten sample plots of $50m{\times}50m$ size were established in 1975 and 1983 at the stands burned by wildfires in 1973 and 1982, respectively. And, the number of naturally regenerated seedlings were monitored in two $50m{\times}4m$ subplots in each plot. The most fire-sensitive conifer species is Abies nephrolepis, while Betula costata is the most fire-sensitive broadleaved tree species. The most fire-resistant species were Q. mongolica, T. taquetii and A. mono. The results of 20 and 30 years after the fire showed that pioneer tree species, e.g. Populus, Salix, and Betula, were regenerated immediately at the early stage of stand development and grew where there is a mono canopy layer with high density. On the other hand, the densities of successors, e.g. Pinus koraiensis, Picea jezoensis, Abies nephrolepis, Acer mono and Tilia taquetii, which were present in the study plots before the fire, increased gradually. Naturally regenerated tree species after forest fire by the growth rate were divided into three groups according to their annual height growth. The seral tree species (Betula costata, Betula platyphylla, Padus maackii, Populus tremula and Sarix caprea) belong to the first group and have the highest growth rate (from 40 to 96 cm per year). The late successional broad-leaved trees (Tilia taquetii, Acer mono and Quercus mongolica) belong to the second group and have intermediate annual height growth (from 3.7 to 13.5 cm per year). The late successional coniferous species (Picea jezoensis, Pinus koraiensis and Abies nephrolepis) form the third group and have the least annual height growth (from 1.4 to 3.5 cm per year).

다중이용업소의 내장재 규정의 적용에 관한 연구 (A Study on the Application of the Regulation of the Interior Materials in Entertainment Occupancy)

  • 이주헌;윤명오;김운형
    • 한국화재소방학회논문지
    • /
    • 제15권1호
    • /
    • pp.100-107
    • /
    • 2001
  • 건물 내장재는 화재 발생 시 화염 확산 및 유독성 가스발생의 주원인으로 피난안전계획에 매우 중요하지만 다중이용업소의 인테리어 공사 시 화재성능에 대한 검증 없이 무분별하게 사용되고 있어 동일한 유형의 인명피해가 반복되고 있다. 따라서 본 연구에서는 국내 내장재 사용 실태조사를 통해 현행 관련규정상 문제점을 살펴보고, 이를 효과적으로 개선, 보완할 수 있는 방안을 제시하였다. 연구 결과, 구조체 밀착재를 제외한 내장재는 가칭 화재안전코드규정에서 사용규제하고, 소방·방화완비증명제도 시행 전 허가·신고된 다중이용업소는 건축법시행령에 소급하여 적용 할 수 있는 근거를 마련하며 지하 소규모 업소에 대한 소방방화시설 법제화, 내부 용도 변경 시 내장재사용 도면첨부 및 무단 변경 시 관련기관에 통보조치, 이동성가구에 대한 방염 처리 의무조항 신설, 화재확산 빛 연기 유독성을 기준으로 하는 재료등급 평가 및 시험방법의 개선이 필요한 것으로 사료된다.

  • PDF

A Study on Fire Spread between Office Room and Atrium in the Atrium Building

  • Lee, Su-Kyung;Kim, Jong-Hoon;Ko, Han-Mog
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.345-352
    • /
    • 1997
  • We could analyse the fire behavior using the developed software for fire safety assessment in a large space such as atrium. But Korean building law hasn't admitted the result of fire risk assessment in atrium. In the legislation fire resistant wall or shutter must be required between atrium and office rooms, That has obstructed development of building design and fire protection technique in Korea. From this point of view, we made scenarios of fire spread between atrium and office rooms, and then computed fire spread and fire phenomena using FASTLite and Breakl. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF

목모보드를 이용한 건식벽체시스템 개발에 대한 실험적 연구 (An Experimental Study on the Development of Dry Wall System using Wood-wool Board)

  • 김대회;박수영;최동호
    • 한국화재소방학회논문지
    • /
    • 제22권3호
    • /
    • pp.208-215
    • /
    • 2008
  • 기존의 목모시멘트보드는 폐목재칩을 이용한 낮은 품질의 시멘트보드였으나, 최근 목재를 섬유형태로 가공하여 제조되는 목모보드는 미관이 수려하고, 흡음 및 단열성이 우수한 내장재로 외국에는 널리 알려진 재료이나, 국내에서는 전량 수입에 의존함에 따라 고가이며 안정적 자재확보의 문제로 인해 다양한 방면의 활용이 이루어지지 못하였다. 그러나, 2005년부터 국내생산이 가능해짐에 따라 경제성 확보 및 자재의 안정적 공급이 가능해짐에 따라 다양한 분야로의 활용이 모색되어지고 있다. 본 연구에서는 목모보드의 활용을 높이기 위하여, 목모보드의 일반특성, 난연성능을 평가하고 건식벽체로 구성하였을 경우 내화성능을 평가함으로써 그 활용성을 모색해보고자 하였다.

내화성 경량 무기 발포보드를 이용한 커튼월 시스템의 시공성능에 관한 연구 (A Study on the Construction Performance of Curtain Wall Systems Using Fire-Resistant & Light-Weight Inorganic Composite Foam Board)

  • 구영아;김성은;오창원
    • 한국건축시공학회지
    • /
    • 제14권2호
    • /
    • pp.127-134
    • /
    • 2014
  • 본 연구는 경량 무기 발포보드를 이용한 커튼월시스템의 시공성 및 경제성 분석에 관한 연구로, 내화성 경량 무기 발포보드는 커튼월의 백패널로 이용하기 위해 개발된 신소재로 내화성능은 선행연구를 통해 실물 내화시험을 실시하여 이미 분석한 바 있다. 본 연구에서는 실제 건물에 내화성 커튼월 시스템을 설치하여 Mock-up test를 수행하고 일반적인 커튼월 시스템과 비교 검토하였다. 이 시스템은 기존의 커튼월 시스템과 동일한 방법으로 시공되는데, 다만 내화성능 확보를 위해 공장에서 제단되어 온 경량무기 발포보드 사용하고, 이를 커튼월 프레임에 취부한다. 비록 기존 커튼월 대비 프레임에 부착해야하는 추가 작업이 발생하나, 경량 무기 발포보드를 이용한 백패널은 커팅만으로 제작이 간편하고, 분진발생이 없어 인체에 무해하며, 파손여부를 바로 확인할 수 있어 품질확보가 용이하다. 따라서 이 시스템은 높은 수준의 내화성을 확보하면서도 시공성과 경제성면에서도 기존 커튼월 시스템과 동등이상임으로 판단된다.

Experimental research on the creep buckling of fire-resistant steel columns at elevated temperature

  • Yang, Kuo-Chen;Yu, Zong-Han
    • Steel and Composite Structures
    • /
    • 제15권2호
    • /
    • pp.163-173
    • /
    • 2013
  • The thermal creep is one of the major factors causing the buckle of steel columns in the fire events. But, few related studies have been reported to evaluate the factors affecting the thermal creep of steel column experimentally or numerically. In this study a series of Fire-resistant steel columns with three different slenderness ratios under a sustained load are tested under a uniform temperature up to six hours in order to evaluate the creep upon three selected factors, temperature, applied load, and column slenderness. Based on experimental results, a proposed creep strain rate model is established as the function of a single parameter of the load ratio of temperature LR(T) to determine the buckling time of steel column due to creep. Furthermore it is found that the creep can be neglected when LR(T) is smaller than 0.77.