• Title/Summary/Keyword: fire-fighting

Search Result 488, Processing Time 0.025 seconds

A Study on the Design Program Development of the Carbon Dioxide Fire Extinguishing System Using an Optimization (최적화 기법을 이용한 이산화탄소 소화설비의 설계프로그램 개발에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.1-9
    • /
    • 2014
  • In this study, it was developed to the design program optimization the design factors of the carbon dioxide fire extinguishing system on the basis of design theory for the carbon dioxide fire extinguishing system, national emergency management agency (NEMA) notice No. 2012-11, KS B 6261 and steepest descent method of optimization. The design program was developed to C++ compiler based on established the logic and algorithms and was to operate on the Windows operating system. The optimization of design factors for the carbon dioxide fire extinguishing system are minimized subject to constraint on agent flow rate, emission time and design variables (pipe size etc.). It was verified to the design program performance for test system, and it was provided to the foundation for optimal design in fire fighting field. Also, it is considered to improve the efficiency of the fire extinguishing system and to maximize of fire suppression as the construction of the carbon dioxide extinguishing system based on the optimal design factors.

Spatial Clustering Analysis of Fire in Gangwon-Do (강원도 화재의 공간적 군집 특성 분석)

  • BAE, Sun-Hak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.3
    • /
    • pp.93-103
    • /
    • 2018
  • The purpose of this study is to analyze the spatial cluster characteristics of fire using long-term fire data. For this, fire data which were broke out in the last 40 years were converted into GIS data and spatial analysis was performed at Gangwon-do province's minimum administrative district level. In order to grasp the spatial distribution of the fire, Moran's I, Geary's Ci and Getis-Ord's Gi*, which are methods that analyze the local indicators of spatial association(LISA), were used. By integrating the characteristics of the spatial distribution of fire by integrating the results obtained from each analysis, the advantages of the individual analysis methods were reflected in the study results. As a result of the study, hotspot areas of fire in Gangwon-do was derived out. Among the hot spot areas, some areas, where the fire frequency is higher than the adjacent areas, have been identified. The results of this study can be used as information for predicting the fire hazard area and relocating of fire-fighting facilities in the study area.

Full-scale Fire Suppression Test for Application of Water Mist System in Road Tunnel (미분무수 소화시스템의 도로터널 적용을 위한 실물 화재 실험)

  • Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae;Lee, Yu-Whan;So, Soo-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.51-56
    • /
    • 2011
  • The full-scale experiments are carried out to investigate the fire suppression characteristics of water-based fire fighting systems in a road tunnel. Applied systems are the low-pressure water spray system at 3.5 bar and the high-pressure water mist system at 60 bar. The water flow rate of the high-pressure system is one sixth only of the water spray system. A passenger car and a heptane fuel pan with area of $1.4m^2$ are used as fire sources. A blower system is installed at the tunnel exit to realize the longitudinal ventilation conditions (0.9~3.8 m/s) in the tunnel. Temperatures from the fire source to the down-stream direction are measured by K-type thermocouple trees. The experimental results show that the cooling effect of the high pressure water mist system in the test conditions were equivalent to that of the low pressure water spray system for B-class fire.

The changes of soil salinity in the Pinus densiflora forest after seawater spread using a fire-fight helicopter

  • Park, Jeong Soo;Koo, Kyu-Sang;Lee, Eun Ju
    • Journal of Ecology and Environment
    • /
    • v.38 no.4
    • /
    • pp.443-450
    • /
    • 2015
  • The east coast of the Korean Peninsula is susceptible to fires because of the low rainfall in winter and spring, and large forest fires have occurred in this area. Lack of fresh water to combat fires has hampered efforts to prevent widespread forest fires in this region. Seawater has not been used as a suppressant because of possible detrimental effects of salt. We investigated the mobility of saline water in the forest soil and their effect on the microbial activity. Using a fire-fighting helicopter, seawater was sprayed over three plots (50 × 100 m) located on the eastern slope of the Baekdu mountain range in South Korea in April, 2011. We sampled the soil in April 4, May 20, and August 5 to determine the amount of salt that remained in the soil. The electrical conductivity value of the soil decreased to <400 μS/cm over a 1-month period. Approximately, four months after the application of seawater, the electrical conductivity value and Na+ content in all treatment plots did not significantly differ to those of the control plot, and total microbial activity also recovered to that of the control. Our results indicate that the amount of rainfall, soil physical-chemical properties, and topological factors may be a critical factor determining the mobility of saline water in forest soil.

A Study on the Application of Fire Risk Assessment Index on the Wooden Cultural Properties -focused on buddhist temples- (목조 건축문화재의 화재위험도 평가지표 및 활용방안 연구 -사찰 건축물을 중심으로-)

  • Kang, Seok-Jin;Ko, Myong-Hwan;Kim, Dong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3550-3561
    • /
    • 2013
  • The purpose of this study was to propose the categorized checklist for fire risk assessment on the wooden cultural properties and to carry out field survey. The survey checklist was composed of categories such as management and administration measures(management, training and countermeasure), architectural planning measures(site plan and facility plan), and equipment measures(fire-fighting and crime prevention facility). In this study, the field survey was carried out in the Nae-jang-sa and Wha-um-sa and it was found that there were some problems in the items which were assessed importantly by experts.

The Influence of the Motivational Incentive Program on the Learning Achievement of New Firefighters (동기유발 프로그램이 신입 소방공무원의 학습성취도에 미치는 영향)

  • Lee, Geun-Chul
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.191-198
    • /
    • 2020
  • The purpose of this study is to examine the impact of synchronous induction programs on new fire-training students' grits and learning outcomes. The research target selected 108 new firefighters from Fire & Marine School. 108 is composed of 54 experimental and control groups and isexecuted once a week, 60 minutes per session, and 10 sessions of synchronous inducement program.The research tools used grids to conduct pre- and post-test, and the mid-term and final-term tests were compared and analyzed. The data analysis was conducted using the SPS 22.0 program.The results showed that the motivational program showed statistically significant differences in the grids and had a significant impacton the final exam results of new firefighters. So, you have a passion for long-term goals and a passion for long-term goals. Research will need to be conducted continuously to raise the level of effort and provide fire-fighting school programs that can help with academic achievement.

A Study on the Safety Security of Emergency Power for Fire Fighting (소방용 비상전원 안전성 확보에 관한 연구)

  • Lee, Won-Kang;Choi, Chung-Seog
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.133-136
    • /
    • 2012
  • 본 논문에서는 소방용 비상전원 안전성 확보에 관한 것으로서, 과부하 조건 회피를 위한 인터록 시스템 및 기타 방법의 한계점을 분석하여 최근 제도적으로 도입된 소방전원보존형 발전기의 필요성과 타당성을 확인하고 나아갈 방향을 제시하는데 있다. 소방부하 및 비상부하 겸용의 자가발전설비에서 어느 한쪽의 용량으로만 택일하여 설치할 경우 정전 및 화재 발생 시 발전기 용량 초과로 비상전원 공급 중단과 소화설비의 미작동의 위험이 초래된다. 소방시설에 비상전원의 안전한 공급을 목적으로 하는 소방전원보존형 발전기는 과부하에 도달되면 소방전원보존용 컨트롤러에서 신호를 발신하여 소방부하는 남겨두고 비상부하의 일부 또는 전부를 차단하고, 소방부하에 비상전원이 연속적으로 공급하고 그 작동 상태가 표시되는 표시장치를 특징을 가진 시스템이다. 소방 안전을 확보하는 제도는 안전을 위한 행정적인 절차와 기준을 지킴으로써 기술적인 안전성이 보장되도록 하는 방식으로 운용되고 있다. 이에는 확인 절차가 필수적으로 요구되는 것이다. 임의의 구두 진술로나 이와 다름없는 임의적인 서류로만 인정할 수는 없는 것이며, 그럴 경우 제도에 의한 소방 안전 확보의 보장성이 무너지기 때문이다.

  • PDF

The Development of a Functional Pressure Controller in Smoke Management Systems for the Fire Safety of Buildings (화재시 제연 및 피난을 위한 기능성 차압 조절장치 개발에 관한 연구)

  • Jung, Ki-Chang;Kim, Jeong-Hun;Lee, Jung-Yun
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.44-48
    • /
    • 2004
  • The smoke and toxic gases generated from the building fires are proved to cause human death. Therefore, the necessity and significance of smoke control have been emphasized, and lots of studies for developing improved smoke management system have been carried out. In this study, the experiments were conducted to evaluated a function and performance in newly developed smoke management system using mechanical pressurization. As a result of this experiment, the differential pressure was 40Pa${\sim}$60Pa and the air velocity through the door was 0.7m/s between safety zone and fire zone. The functional pressure control equipment which could make proper pressure and maintain differential pressure between safety zone and fire zone was developed. And it will give a lot of helps to evacuation activity for peoples in building and fire fighting.

Study on Remedies of Convergence Design for Personalized Fire Helmets (개인 맞춤형 소방용 헬멧의 융합 디자인 방안 연구)

  • Ahn, Yong Jun;Kang, Myung Chang;Lee, Tae Gu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.5
    • /
    • pp.371-376
    • /
    • 2016
  • Safety related workers, such as firefighters, have to wear a protective helmet. The Development of Helmets for safety is in progress to promote the wearable device industry. Several accidents caused by negligence in recent days have raised public attention to safety. For this reason, the amount of national budget funding for the study of fire-fighting and smart safety helmets has increased. However, most previous studies have focused on safety, rather than the application of new technologies based on physical attributes, especially the characteristics of head shape and size, even though fire helmets play the critical role of protection from flames and external shocks etc. in an emergency. This paper will present the smart technologies and newly developed designs for safety helmets that are personalized for each firefighter, based on the characteristics of their head, and will help a rescue operation to be much more safe and efficient.

Plan for the Development of a Standardized Dummy for Persons in Need of Rescue in a Confined Space (밀폐공간 구조 요구자를 위한 더미 표준화 개발 방안)

  • Choi, Seo-Yeon;Rie, Dong-Ho;Kim, Hyung-Jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.99-105
    • /
    • 2016
  • This study was conducted to develop a dummy in an environment similar to the human body, to prepare a standard for evaluation and to present the process of the production in order to evaluate the performance of the robot that can detect the persons needing rescue in a confined space, who are difficult for fire-fighting officials to rescue in case of fire and disaster. As a result, a standard for evaluation was developed and standardized into four parts 'Normal,' 'Risk Stage 1,' 'Risk Stage 2' and 'Risk Stage 3'based on the number of breath cycles, carbon dioxide concentration, core temperature and criteria for hearing to recognize the voice. In addition, in order to produce a dummy, fever, breathing capacity and voice output function were compared and analyzed. This study has significance that it built up basic data of the method of producing the actual dummy, by presenting characteristics and controlling methods using the waterproof insulation heating coil for the function, solenoid valve for the consecutive output of breathing capacity and USB program sound board for voice output.