• Title/Summary/Keyword: fire temperature prediction

Search Result 143, Processing Time 0.019 seconds

A Study on Yunqi Climate (運氣氣候) through analysis of Meteorological research data in Korea (한국(韓國) 기상자료(氣象資料)의 분석(分析)을 통(通)한 운기(運氣) 기후(氣候)에 관(關)한 연구(硏究))

  • Park, Chan-Young;Kim, Ki-Wook;Park, Hyun-Kook
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.1-24
    • /
    • 2000
  • The comparison of climate's character of Yunqi(運氣) with the data of meterological observation were made in the research of climate. 1. The comparison of the average velocity of wind, temperature, rainfall, humidity of Seoul, by late 1954 to 1983, with Yunqi(運氣) was made. Fire-Chi(火氣) and moisture-qi(濕氣) were matched with the attribute of Taiyun(大運). Cold-qi(寒氣) was had some relationship. Dry-qi(燥 氣) and Wind-qi(風氣) were not matched. About the relationship of Spirit-of-official-sky(司天之氣) with climate, when the Moisture-soil(濕土) was added, they were matched and when the King-fire(君火) was added, they have some relationship. But Wind-tree(風木), Dry-metal(燥金), Buble-fire(相火), Cold-water(寒水) was added they were not matched. 2. According to the observation data of rainfall by late 180 years of Seoul; about Taiyun(大運), when the Water-Yun(水運) was greatly exceeded and Fire-Yun(火運) was shorted, in the case of Official-sky(司天), when Wind-Tree(風木) was added, the frequency was highly. So when the Soil-Yun(土運) was greatly exceeded and when Official-sky(司天)was added to the Moisture-soil(濕土), the rainfall was not matched. 3. The relationship of the frequency of the abnormal climate occurrences between Yunqi-promotion-weak(運氣盛衰)and Yunqi-Harmony(運氣同化) and Yunqi-soft-attacking(運氣順逆) in the weather of Korean Peninsula was compared by 1564 to 1863. They were not matched except the case of Yunqi-Harmony(運氣同化). 4. There were some cases which were not matched exactly between the climate predicted by the theory and real climate in 1984, the year of Kap-ga(甲子年). But many correspondence between the observation by the office of meteorology and the prediction by the analysis from Yun-qi-sang-hab(運氣相合) theory. 5. Because meterological phenomena of real world and analysis from the hypothesis of Yunqi(運氣) have no relationship with each other, some of Doctor denied Yunqi(運氣) in the way of matching mechanically. But the thought of Doctor who denied Fortune-spirit(運氣) made promotion for the theory of divination by bringing deeper insight. And it was not only the negative side. 6. In the point of geographical difference, the climate of China, the origination Yunqi theory, is different from the Korea's. Thus some observation errors should be considered. From the basis of this thesis, I hope that the deeper advance would be made into the Korean Yunqi theory.

  • PDF

The Measurement and Prediction of the Combustible Properties of of Benzyl-Alcohol for MSDS (Material Safety Data Sheet) (MSDS (Material Safety Data Sheet)를 위한 벤질알코올 연소특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.190-194
    • /
    • 2017
  • The combustion properties for the prevention of the fire and explosion in the work place are flash point, explosion limit, autoignition temperature (AIT) etc.. The using of the corrective combustion properties of the MSDS (Material Safety Data Sheet) of the handling substance for the chemical process safety is very important. For the safe handling of benzyl alcohol which is widely used in the chemical industry, the flash point and the AIT were measured. And, the lower explosion limit (LEL) of benzyl alcohol was calculated by using the lower flash point which obtained in the experiment. The flash points of benzyl alcohol by using the Setaflash and Pensky-Martens closed-cup testers measured $90^{\circ}C$ and $93^{\circ}C$, respectively. The flash points of benzyl alcohol by using the Tag and Cleveland open cup testers are measured $97^{\circ}C$ and $100^{\circ}C$. The experimental AIT of benzyl alcohol by ASTM 659E tester was measured as $408^{\circ}C$. The LEL of benzyl alcohol measured by Setaflash closed-cup apparatus was calculated as 1.17 vol% at $90^{\circ}C$. In this study, it was to possible predict the LEL by using the lower flash point of benzyl alcohol which measured by Setaflash closed-cup tester.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.