• Title/Summary/Keyword: fire statistics

Search Result 219, Processing Time 0.022 seconds

The Heating of Cu-oxide and Arc Properties according to Electrical Poor Contact (전기적 불완전 접촉에 따른 동산화물의 발열 및 아크 특성)

  • Kim, Wansu;Park, SangJune;Hwang, DongHyun
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.15-20
    • /
    • 2019
  • As industry is progressing and standards of living are improved, the demand of electrical energy is expected to grow 8-9% annually. Therefore, the importance of electrical fire prevention technology with the ability of the power supply is being emphasized. According to the statistics of fire in Korea, fire occurred about 45,000 cases annually, and electrical fire possessed about 20%. The electrical fire by poor contact has increased gradually, can be connected as great fire to secondarily induce short circuit and earth fault. Then analysis of heating causes of electrical connections between copper and copper alloy is needed. Also, detection and analysis algorithm of oxide at copper alloy are necessary. In this research, in order to understand the characteristics of oxide growth with rising resistance and heating, it is demonstrated that the oxide at electrical connections can cause fire due to arcing.

The Development on the Estimate method for the Cost-Effect Analysis of the Electrical Safety Management (전기안전 업무의 비용효과 분석을 위한 전기화재 손실비용 추정방법 개발)

  • Yoo, Jae-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.349-352
    • /
    • 2015
  • This paper estimates electrical fire damage cost-effect to analyze electrical safety efficiency by applying a cost-benefit analysis method for analyzing the efficiency of a business public interest. Electrical fire loss statistics data was presented as direct costs and casualties, including deaths due to an electrical fire, this paper adds overhead "Incidental Cost of Accidents to the Employer" by W. H. Heinrich was applied to estimate the cost of economic loss. Also wounded, including the loss of human deaths by referring to the car accident insurance claims costs and human development estimated the losses caused by an electrical fire. And to perform a cost-benefit analysis of the electrical safety as a result of future work. In this paper, the economic effect of the electric field of safety and public interest work to systematically presented.

A Study on Ignition and Fire Risks of Electric Heat Wire (전기적 열선의 발화 및 화재 위험성에 관한 연구)

  • Min, Se-hong;Song, Byeong-jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.113-121
    • /
    • 2015
  • This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the 'heat wire') and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.

A Survey Study on the Usage and Situation of Indoor Fire Hydrants (옥내소화전의 사용실태 및 현황에 관한 연구)

  • Lee, Wonjoo;Lee, Chang-Seop
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.141-146
    • /
    • 2016
  • The purpose of this paper is to investigate the basic data (e.g. education experience and awareness of the installation situation, and usage of indoor fire hydrants) for the effective planning, progress and improvement of fire safety education. For this purpose, we surveyed 198 participants and an analysis of the frequency and descriptive statistics based on the survey data was carried out using SPSS 20.0 for Windows. The analysis results showed that 87.9% of the research participants live in accommodation with indoor fire hydrants installed and that, among them, 17.7%, did not know their location. 63.6% of the research participants, had received fire safety education but, among them, 31.0% had never been educated about the use of indoor fire hydrants. The main type of fire education was instructor-led training, which represented 50.0% of the participants. We believe that the results of this paper will serve as a basis for efficient adult fire safety education.

Numerical Study on the Effect of Range Surrounding Environment on Detecting Time for Cooking Oil Fire in Kitchen (주방내 조리용 기름 화재 발생시 레인지 주변 환경이 감지 시간에 미치는 영향에 대한 수치해석적 연구)

  • Lee, Jin-Woo;Ko, Gwon-Hyun;Ryou, Hong-Sun;Jang, Yong-Jun;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.134-139
    • /
    • 2010
  • According to the "Yearbook of disaster response, fire safety and fire statistics (NEMA: National Emergency Management Agency)", approximately 34% of all fire is interior fire such as hotel, restaurant and residence and more than 53% of which is occurring in the kitchen. The evaluation of fire extinguishing system in the kitchen is performed in accordance with the "Korea Fire Equipment Inspection Standard (KOFEIS 0101-1)" which is using one environmental condition. However, only using one environmental condition is not enough to evaluate the performance of the automatic fire extinguisher in kitchen fire. So the study of fire detecting characteristic about various environmental condition needs. In this study, the numerical analysis is carried out about detecting time characteristic for various range's surrounding environment. As a result, it showed up to 100 s difference in the detection time depending on the position of the range. And detecting time also showed difference for on-off hood operation. From this results, it can be verify and improve the evaluation standard for the fire extinguishing system in kitchen fire.

The Comparative Study on the Effect of Fire Needling Therapy and General Acupuncture with Other Korean Traditional Medical Treatment for the Patient with Lumbar Herniated Intervertebral Disc: A Randomized, Assessor Blinded, Two Arm Trial (요추 추간판 탈출증 환자에 대하여 기타 한방치료를 병행한 가열식 화침과 일반침의 효능 비교 연구: 무작위배정, 평가자 맹검, 평행군 설계)

  • Jung, Se Ho;Sung, Hee Jin;Lim, Su Ji;Lee, Eun Yong;Lee, Cham Kyul
    • Journal of Acupuncture Research
    • /
    • v.32 no.4
    • /
    • pp.29-36
    • /
    • 2015
  • Objectives : The purpose of this study is to compare the efficacy of fire needling therapy and general acupuncture for the patient with lumbar herniated intervertebral disc. Methods : We observed 20 lumbar herniated intervertebral disc patients from March, 2014 to October, 2015. This study was randomized and assessor blinded. The patients were divided into two groups: one group(group A) was treated by general acupuncture only, and the other group(group B) was treated by fire needling therapy and general acupuncture. We evaluated the treatment effect experienced by each group using the visual analogue scale(VAS) and Oswestry disability index(ODI). Results : 1. In group A, VAS and ODI from before treatment to treatment 4, 8, 12, 16 were significantly improved in statistics. 2. In group B, VAS from before treatment to treatment 4, 8, 12, 16 was significantly improved, but ODI was significantly improved in statistics only from before treatment to treatment 12, not in treatment 4, 8, 16. 3. As a result of comparisons between group A and B, there were no statistical significance in VAS and ODI. Conclusions : This study was not able to determine statistical significance between the group treated by general acupuncture only and the group treated by fire needling therapy and general acupuncture, so further studies are required in the future.

Analysis of Actual State of Motor Vehicle Fires in Korea (자동차화재 실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.47-59
    • /
    • 2011
  • The actual state of motor vehicle fires was analyzed based on Annual Report on Fire Statistics and National Fire Data System and as a result, the followings were obtained. Motor vehicle fires occur over 16 cases every day with over 0.5 casualties and direct property loss of 50 million won. Most motor vehicle fires are caused by mechanical reasons, followed by electrical factors and arson. Arson accounts for 7.39% of all fires but 13.79% of all motor vehicle fires. Yearly fatalities and casualties per 100 motor vehicle fires were 0.9 and 2.4 on the average, respectively. Although fires which occur in the expressway account for 12.55% of all motor vehicle fires, fatalities, casualties, and property loss caused by motor vehicle fires in the expressway were 16.12%, 21.05%, and 20.65%, respectively.

A Study on the Evacuation Safety Design laws based on the Fire Risk (화재리스크에 기초한 피난안전설계법에 관한 연구)

  • Huh, Ye-rim;Kim, Hye-Won;Lee, Byeong-Heun;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.51-52
    • /
    • 2019
  • Currently in domestic, it is difficult to the evacuation in fire due to the building is higher. Therefore it is necessary to evacuation safety design of building. To conduct the evacuation fire design of building, it should be done the Evacuation Safety Verification. But it is not sufficient the Study about Evacuation Safety Verification in currently domestic. Therefore in this study, we conducted the evacuation safety verification using people who they can't the evacuation themselves. The method of verification, we suggest the comparative that people who they can't the evacuation themselves and available safety evacuation time. Available safety evacuation time is determined by determined method from disaster statistics of casualties or equivalence with current standard requirement. it is doing to objectively judge of evacuation safety design validity in building.

  • PDF

A Study on Certification Requirements and Means of Compliance about In-Flight Smoke (비행 중인 항공기에 발생할 수 있는 연기에 대한 인증기준 및 적합성 입증방법)

  • Jeong, Bonggu;Jin, Yongkwon;Kim, Yougwang;Park, Guenyoung
    • Journal of Aerospace System Engineering
    • /
    • v.1 no.4
    • /
    • pp.7-12
    • /
    • 2007
  • From the beginning of aviation history, in-flight smoke/fire events have been a serious issue. As aircraft are getting larger and are becoming more auto-piloted and aircraft systems are getting more complex, it is an increasing risk of in-flight smoke/fire accidents accompanied with fire events. Therefore, we review the statistics of fire/smoke accidents in order to enhance an understanding for risk of in-flight smoke events, and present the certification requirements for smoke per KAS Part 25. In addition, we provide acceptable methods of complying with related requirements, such as smoke detection test, smoke penetration test and smoke evacuation test.

  • PDF

Analysis of a Fire Case Caused by Heat Generation due to Cu2O Breeding (아산화동증식 발열에 의한 화재 사례의 분석)

  • Park, Jin-Young;Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.54-63
    • /
    • 2020
  • Although fires caused by heat generation due to Cu2O breeding in wire connections are well-known among fire investigators, there are few papers on the analysis and introduction of fire cases by heat generation due to Cu2O breeding. This study analyzed fire statistics caused by heat generation in electrical connections and the phenomena and features of heat generation due to Cu2O breeding. Then, a fire which occurred in the wire connection in a university lab by heat generation due to Cu2O breeding was analyzed in more detail. This fire case could reach a conclusion that heat generation due to Cu2O breeding caused a fire in the wire connection through the fire pattern investigation of fire origin, the visual investigation of wire connection, 3D CT, power-on-test, and stereoscopic microscopy, SEM and EDS analysis.