• 제목/요약/키워드: fire safety standards

검색결과 247건 처리시간 0.024초

국내 제조업 화재감시자 운영의 문제 확인 및 개선방안 (Identification of Problems and Improvement Measures of Fire Observer Operation in Domestic Manufacturing Industry)

  • 김경민;서용윤;이종빈;장성록
    • 한국안전학회지
    • /
    • 제38권6호
    • /
    • pp.26-35
    • /
    • 2023
  • Sparks cause most fire and explosion accidents in the manufacturing industry during hot work, which ignites surrounding combustible materials. Such incidents lead to high casualties due to suffocation from toxic gases and lack of evacuation. Therefore, the government recently enacted and revised 'The Occupational Safety and Health Act' to prevent fires and explosions at work sites, incorporating legal standards for fire observers, which are important in preventing accidents and the spread of fire during hot work. However, there are notable shortcomings in conducting professional cause analysis of these accidents and in aligning them with advanced foreign legal standards. Additionally, there is a lack of literature review reflecting the manufacturing industry characteristics. Despite the recent enactment and revision of legal standards, gathering sufficient opinions and professional reviews remains insufficient. To address these gaps, interviews were conducted with safety and health workers, analyzing recent fire and explosion causes in domestic manufacturing industries, and reviewing both domestic and international legal standards. Conclusively, proposed improvement measures were centered on the professionalization of fire observer education, enhancing their roles and authority realistically, and improving fire observer placement and operation standards. Consequently, additional 'Occupational Safety and Health Act' standards are necessary for fire observer education and defining the government's role. Second, precise legal standards outlining the role and authority of fire observers are required. Third tailored fire observer arrangements and management standards appropriate for varying work characteristics and company sizes are required. This study emphasizes the importance of supplementing relevant legal standards to prevent fire accidents in the manufacturing industry.

LATEST INTERNATIONAL DEVELOPMENTS IN PASSIVE FIRE PROTECTION

  • Marx, Olliver
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.227-243
    • /
    • 1997
  • Fire and smoke can from a small ignition source develop rapidly. Active systems in combination with Passive Fire Protection measures will offer highest safety standards to the building's developers and occupants. Nevertheless, the fire growth is very unpredictable and it is therefore essential at the planning stage that tested solutions are well selected according to National codes and later on installed by qualified contractors to ensure optimum performance. This demonstrates that Passive Fire Protection as safety measure cannot be neglected. Recent fire cases all over the world still proof that fire can develop any time and any where even in countries of high safety standards.

  • PDF

화재피해 감소 위한 자동소화장치 적용범위 개선 (Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage)

  • 백창선;박인선
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.62-65
    • /
    • 2018
  • The rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the "Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems" cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than $300m^2$, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.

A Review on Fire Safety Engineering: Key Issues for High-Rise Buildings

  • Li, Guo-Qiang;Zhang, Chao;Jiang, Jian
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.265-285
    • /
    • 2018
  • This paper presents a state-of-the-art review on the design, research and education aspects of fire safety engineering (FSE) with a particular concern on high-rise buildings. FSE finds its root after Great Fire of Rome in 64 AD, followed by Great London Fire in 1666. The development of modern FSE is continuously driven by industry revolution, insurance community and government regulations. Now FSE has become a unique engineering discipline and is moving towards performance-based design since 1990s. The performance-based fire safety design (PBFSD) involves identification of fire safety goals, design objectives, establishment of performance criteria, and selection of proper solutions for fire safety. The determination of fire scenarios and design fires have now become major contents for PBFSD. To experience a rapid and positive evolution in design and research consistent with other engineering disciplines, it is important for fire safety engineering as a profession to set up a special educational system to deliver the next-generation fire safety engineers. High-rise buildings have their unique fire safety issues such as rapid fire and smoke spread, extended evacuation time, longer fire duration, mixed occupancies, etc., bringing more difficulties in ensuring life safety and protection of property and environment. A list of recommendations is proposed to improve the fire safety of high-rise buildings. In addition, some source information for specific knowledge and information on FSE is provided in Appendix.

건축물 창호의 화재위험성 평가를 위한 실험적 연구 (An Experimental Study to Evaluate the Fire Risk of Building Windows)

  • 이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.77-78
    • /
    • 2022
  • This study compared the fire safety standards for windows of Korea, the U.S. and Japan to prevent fire expansion through exterior wall openings, and conducted experiments using PVC and aluminum window frames, which are widely used in Korea.The experiment is KS F 2845 which combines frames of the same thickness and area with single-window form and 1 hour fire resistance glass with 8T thickness. Experiments showed that the PVC window was about 9 minutes and the aluminum window was about 26 minutes. However, in Korea, there are no test standards for windows installed at the opening of the exterior wall. In addition, fire safety standards for windows shall be established along with the designation of fire prevention zones.

  • PDF

건축물 창호 프레임의 연소특성에 따른 방화성능 검증에 관한 실험적 연구 (An Experimental Study on the Verification of Fire Extinguishing Performance According to the Combustion Characteristics of Building Window Frame)

  • 이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.54-55
    • /
    • 2021
  • This study compared the fire safety standards for windows of Korea, the U.S. and Japan to prevent fire expansion through exterior wall openings, and conducted experiments using PVC and aluminum window frames, which are widely used in Korea.The experiment is KS F 2845 which combines frames of the same thickness and area with single-window form and 1 hour fire resistance glass with 8T thickness. Experiments showed that the PVC window was about 9 minutes and the aluminum window was about 26 minutes. However, in Korea, there are no test standards for windows installed at the opening of the exterior wall. In addition, fire safety standards for windows shall be established along with the designation of fire prevention zones.

  • PDF

고층 주거시설 화재사례를 고려한 인명안전기준 개선방안에 관한 연구 (A Study on the Improvement of Human Safety Standards Considering Fire Cases in High-rise Residential Facilities)

  • 조휘제;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.106-107
    • /
    • 2021
  • The fire in Ulsan in 2020 was a 33-story residential and commercial complex with about 90 injuries and more than 10 billion won in property damage, and considering the recent increase in high-rise residential and commercial complexes, the risk of similar fires is high. As can be seen through the residential and commercial complex fire case in Ulsan, life-based fire safety standards need to be established to minimize casualties. Therefore, the purpose of this study is to draw improvements for the development of human safety standards for high-rise residential facilities in the future through comparison with the Korean Building Act, Firefighting-rellated Acts and the U.S. NFPA 101.

  • PDF

한국형 인명안전기준 개발을 위한 국내외 화재사례 조사 (A Study on Domestic and Foreign Fire Cases for the Development of Korean Life Safety Standards)

  • 이병흔;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.61-62
    • /
    • 2020
  • After the fire in Grenfell, a special fire safety survey was conducted, and the spirit of building fire safety is increasing. However, as can be seen from the fact that more than 80 people were injured in the Ulsan residential fire in 2020, there are no cases of making it a life safety standard for buildings, and there is an urgent need to investigate this. In this research, we will investigate the five fires that occurred in Grenfell, England, derive the problems, and use them as basic data for establishing the safety standards for Korean-style human life in the future.

  • PDF

국내 제조업 화재사고 데이터 분석을 통한 복합 유해·위험요인 확인 (Identifying Hazard of Fire Accidents in Domestic Manufacturing Industry Using Data Analytics)

  • 김경민;서용윤;이종빈;장성록
    • 한국안전학회지
    • /
    • 제38권4호
    • /
    • pp.23-31
    • /
    • 2023
  • Revising the Occupational Safety and Health Act led to enacting and revising related laws and systems, such as placing fire observers in hot workplaces. However, the operating standards in such cases are still ambiguous. Although fire accidents occur through multiple and multi-step factors, the hazards of fire accidents have been identified in this study as individual rather than interrelated factors. The aim has been to identify multiple factors of accidents, outlining fire and explosion accidents that recently occurred in the domestic manufacturing industry. First, major keywords were extracted through text mining. Then representative accident types were derived by combining the main keywords through the co-word network analysis to identify the hazards and their relationships. The representative fire accidents were identified as six types, and their major hazards were then addressed for improving safety measures using the identification of hazards in the "Risk Assessment" tool. It is found that various safety measures, such as professional fire observers' training and clear placement standards, are needed. This study will provide useful basic data for revising practical laws and guidelines for fire accident prevention, system supplementation, safety policy establishment, and future related research.

국가화재안전기준(NFSC)의 제·개정 시스템 개선에 관한 연구 (A Study on the Systemic Improvement for the Enactment and Revision of the National Fire Safety Code)

  • 송영주;김태우;정기신
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.110-119
    • /
    • 2020
  • 화재안전기준은 소방시설법 시행령 별표1에서 규정하고 있는 소방시설에 대한 설치방법 및 기술적 기준을 규정한 것으로 공공의 안전확보와 화재예방을 위한 근간으로서 그 역할을 수행하여왔다. 그러나 현행의 화재안전기준은 성능 기준과 기술기준이 혼재되어있는 형태로 장기간의 개정 절차와 제도적인 경직성으로 인해 기준의 제·개정이 신속하게 진행되기 어렵다. 또한, 기준을 제·개정하고 유지관리 할 수 있는 전문적 상임 독립기구의 부재로 인해 전문성 유지에 한계가 있으며 그 외에도 총의(總意)성, 공개성, 일관성이 결여되는 문제가 있다. 따라서, 이러한 문제점을 극복하기 위해 본 연구에서는 화재안전기준의 변천 및 운영 현황, 법적 성질 및 법적 현황 그리고 제·개정 시의 문제점을 살펴보고 국내·외 유사 기술기준의 운영사례를 비교 분석하여 화재안전기준의 제·개정 시스템을 개선하고자 하였다. 이것을 나타내면 다음과 같다. 첫째, (현(現))국가화재안전기준을 법적 성능 기준과 기술적 세부기준인 기술기준으로 분류한다. 둘째, 기술기준의 제·개정 주체를 기존의 국가에서 민간으로 이양시킨다. 셋째, 기술기준을 사용자 중심의 코드 시스템으로 정비하는 것이다.