• Title/Summary/Keyword: fire retardant

Search Result 264, Processing Time 0.028 seconds

A Study on Flame Retardant Performance of Vertical Blind and Roll Screen (버티칼 브라인드와 롤 스크린의 방염성능 유지에 관한 연구)

  • Jeong, Hyun Gyu;Cho, Woncheol;Lee, Tae Sik
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.41-46
    • /
    • 2010
  • This study focuses on two points. First, I have examined the difference on combustion between flame-retardant and non flame-retardant products including vertical blinds and roll screens that are widely used as a substitute for fabric curtains. The second point is to see how long flame-retardant goods can be durable, that is, flame retardant durability after washing in liquid. the experiment on the flame-retardant ability before and after washing of vertical blinds and roll screens that have been used for a long time in fire protection construct. Comparing and analyzing domestic and foreign laws on flame-retardant after the experiment on durability of these products. I aim to draw necessity for increased application of internal laws and regulations on flame-retardant and show how to improve the point at issue. According to the result, clear differences in performance and safety were observed between flame-retardant and non flame-retardant products. flame-retardant materials can prevent things from fire spread without igniting but melting when they've met flame and burnt, In contrast, non flame-retardant material for experiment which size is 120cm long takes less than 3 minutes only to be completely destroyed by fire. However, it was expected for flame-retardant durability of flame-retardant blinds which are not washable to decrease flame-retardant durability after being washed with water, there was no sharp difference. so it is demonstrated that flame-retardant blinds can keep flame-retardant durability. accordingly through the strict course of product we are concerned about keeping durability.

  • PDF

Study on Manufacture and Properties of Polymer Compounds for Cable Sheath (전선피복용 고분자 컴파운드의 제조 및 물성 연구)

  • Li, Xiangxu;Lee, Sang Bong;Cho, Ur Ryong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.1
    • /
    • pp.42-47
    • /
    • 2019
  • The four different polymer compounds were manufactured to make cable sheath for ship industry. Two kinds of ethylene-vinyl acetate (EVA) were selected as main matrix polymers for compounding with fire retardant, crosslinking agent, filler, plasticizer, and other additives. The properties of the four compounded materials were investigated with the contents of fire retardant, silane coated aluminum hydroxide (S-ATH). Rheology, Mooney viscosity, and tensile strength increased with S-ATH contents by reinforcing effect. With increasing fire retardant amount, fire resistance increased, but cold resistance didn't show an obvious enhancement due to polar effect of vinyl acetate in EVA.

Economic effect analysis of flame retardant aluminum screen development

  • Park, Bum-Soon;Han, Chung-Soo;Kang, Tae-Hwan;Lee, Hee-Sook
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.3
    • /
    • pp.496-505
    • /
    • 2016
  • The purpose of this study was to investigate the economic effects of a flame retardant aluminum screen developed by a company Economic effects were analyzed in terms of micro and macro-economic aspects. In the macro-economic aspect, economic effects were analyzed under the assumptions that the total import volume of flame retardant aluminum screen was approximately $50m^2$ in 2015 and that possible import substitution rates were 100%, 80%, and 60%. Results showed economic values of 2.25 billion won (100% import substitution rates), 1.8 billion won (80% import substitution rates), and 1.35 billion won (60% import substitution rates). If existing farms which had been using imported flame retardant aluminum screen replaced it newly developed with the flame-retardant aluminum screen developed in this study at rates of 100%, 80%, and 60%, the farms could save 750 million won, 60 million won, and 45 million won, respectively. Furthermore, the social cost savings from fire prevention could be 1.184 billion won. In the micro-economic aspect, if a farm with a typical-size ($1,000m^2$) greenhouse growing red pepper wanted to install flame retardant aluminum screen instead of generic aluminum screen, the farm may only pay an additional cost of 720,000 won. In comparison, if the farm chose fire insurance instead of flame-retardant aluminum screen, then the farm would pay 21,000,000 won for fire insurance. The above results show that the economic effect of flame retardant aluminum screen developed by the company would be be very efficient compared to the imported one.

Ignition and Heat Release Rate of Wood-based Materials in Cone Calorimeter Tests

  • Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.1-8
    • /
    • 2008
  • This study was performed to evaluate the burning characteristics of wood-based materials and the effect of surface treatment of fire retardant using cone calorimeter. Four types of wood-based materials, such as Plywood, Oriented Strand Board (OSB), Particle Board (PB) and Medium Density Fiberboard (MDF), were tested at a constant heat flux of $50kW/m^2$ to investigate the time to ignition, mass loss rate, heat release rate, effective heat of combustion, etc. In addition, each type of wood-based material was tested at the same heat flux after fire retardant treatment on the surface to evaluate the effect of this treatment on the burning characteristics. The surface treatment of fire retardant, by the amount of $110g/m^2$, delayed the time to ignition almost twice. However, it was indicated that heat release rate, mass loss rate, and effective heat of combustion were not significantly affected by fire retardants treatment for all types of wood-based materials.

A Study on Char Characteristics of Fire Retardant Treated Douglas Fir (난연처리된 Douglas Fir의 탄화특성에 관한 연구)

  • Park Hyung-Ju;Oh Kyu-Hyung;Kim Eung-Sik;Kim Hong
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.105-110
    • /
    • 2005
  • We tested the char characteristics of fire retardant treated Douglas fir at each of five constant external irradiance levels $(10,\;15,\;20,\;25\;및\;35kW/m^2)$. A Cone heater was used to expose the wood specimens to the heat flux. The size of specimens is 100- by 100- by 50-mm and the kinds of specimens are non-treated wood(N) and treated wood(F2 and f4) by water soluble fire retardants. The water-soluble fire retardants were made from mixture of aqueous solutions of monoammonium phosphate, sodium borate and zinc borate, and those are used for immersion of Douglas fir. In result of test, char fraction of fire retardant treated Douglas fir showed a considerably low char fraction than it of non-treated wood irrespective of increase of external heat flux. And char fractions has low levels with increase of fire retardant content. Burning rate of non-treated wood(N) was showed a relatively high burning rate than it of fire retardant treated wood(F2 and F4). And difference of burning rate shown more rapidly in high external irradiance than low external irradiance. When the external heat flux is $35kW/m^2$, average char rate of non-treated wood is rapidly about twice than fire retardant treated wood. Water-soluble fire retardants mixed in this study find out it has fire suppression and adiabatic effect by char layer from results of char fraction, burning rate, and char depth and rate.

Experimental testing and evaluation of coating on cables in container fire test facility

  • Aurtherson, P. Babu;Hemanandh, J.;Devarajan, Yuvarajan;Mishra, Ruby;Abraham, Biju Cherian
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1652-1656
    • /
    • 2022
  • Fire tests were conducted on cables using fire-retardant paint employed in nuclear power plants that transmit electrical power, control and instrument signals. The failure criteria of various power and control cables coated with fire retardant coating at three different coating thicknesses (~0.5 mm, 1.0 mm & 1.5 mm) were studied under direct flame test using Container Fire Test Facility (CFTF) based on standard tests for bare cables. A direct flame fire test was conducted for 10 min with an LPG ribbon burner rated at ten by fixing the cable samples in a vertical cable track. Inner sheath temperature was measured until ambient conditions were achieved by natural convection. The cables are visually evaluated for damage and the mass loss percentage. Cable functionality is ascertained by checking for electrical continuity for each sample. The thickness of cable coating on fire exposure is also studied by comparing the transient variation of inner sheath temperature along the Cable length. This study also evaluated the adequacy of fire-retardant coating on cables used for safety-critical equipment in nuclear power plants.

Fire Resistance Properties of Chloroprene Rubber containing Inorganic Flame Retardant

  • Sung, Il Kyung;Park, Chan Young
    • Elastomers and Composites
    • /
    • v.50 no.4
    • /
    • pp.279-285
    • /
    • 2015
  • This study examined the mechanical properties and the flame retardant properties of CR rubber containing inorganic flame retardant with various contents of aluminium trihydroxide (ATH, $Al(OH)_3$). The content of aluminium trihydroxide was added in 0, 30, 50, 70 and 100 phr for T1~T5 samples. It was found that increasing the amount of addition over 30 phr resulted in decreasing the mechanical properties. On the other hand in oxygen index measurements T1 sample showed a value of 38.6%, indicating the improvement of flame retardant properties showed a value of 49.7~64.2%. In case of burn test, it was confirmed that CR rubber containing over ATH 50phr content showed performance corresponding to that of first grade fire-resistance.

A Study on the Large Experiments (ISO 13785-2) for Vertical Fire Behavior Analysis of Aluminum Composite Panels in General and Flame-retardant Material (일반재와 난연재 알루미늄복합패널의 수직화재 성상분석을 위한 실대형시험(ISO 13785-2)에 관한 연구)

  • Choi, Chui-Kyung;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.92-98
    • /
    • 2012
  • In this sturdy, large experimental (ISO 13785-2) was performed to analyze the building materials used in fire retardant materials for aluminum composite panel and in general properties. As a results, maximum temperature in the case of the general materials was measured in 210 seconds $1,021^{\circ}C$, the retardant materials was measured in 1,200 seconds early $1,190^{\circ}C$. The retardant material of aluminum composite panel, Fire behavior if the ignition is slow and the general materials in aluminum composite panel, fire ignition and combustion at the same time was growing rapidly. The general materials and flame-retardant material of aluminum composite panel was an obvious difference to the combustion ignition but after ignition combustion mode showed a similar pattern of the rapidly vertical spread of flame. The results of this study, in order to reduce the risk of aluminum composite panels for fire and the retardant materials used for ignition the slow should be actively encouraging. Also after the ignition, there is an urgent need to put out a fire in exterior materials for extinguishing facilities.

An Experimental Study on the Fire Hazards in Electric Heater (전기히터의 화재위험성에 관한 실험연구)

  • Hong, Sung-Ho;Lee, Bock-Young;Park, Sang-Tae;Yu, Hyun-Jong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.2 s.80
    • /
    • pp.36-40
    • /
    • 2007
  • This study presents on the analysis fire hazards of electric heater. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate normal condition and abnormal condition. The abnormal condition experiment is simulated in which combustibles are placed near by electric heater. Vertical burning test(UL 94) is conducted for the fire retardant experiment. The results show that fire hazard is high in case of abnormal condition. And Material of electric heater has not fire retardant performance. In this paper, we suggest to add temperature fuse in electric heater for reducing fire hazard.