• Title/Summary/Keyword: fire resistant

Search Result 269, Processing Time 0.022 seconds

An Empirical Study on the Relay Pumping Method for the High Pressure of Fire Engine Pump (소방펌프차의 고압방수를 위한 중계방수방식에 관한 실증적 연구)

  • Min, Se-Hong;Kwon, Yong-Joon;Park, Jong-Deok
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.52-59
    • /
    • 2013
  • In this study, tests were conducted to establish a fire engine of relay waterproof and utilization in order to maintain the pressure in a situation that require high-pressure water-resistant such as a high-rise building fire, etc. As a result of test on the change of a relay waterproof pressure, the measurement result with the hydrant intake of a fire engine opened has reduced approximately 20 % compared to the measurement result with the hydrant intake closed. Similar efficiency showed in the test result that change the pressure of 2 fire engines respectively to use them more efficiently at a fire fighting activity site. A fire engine operation and utilization is proposed based on this study result in order to cope effectively with a fire site requiring high-pressure stream in a high-rise building fire, etc. by using a fire engine held at present because there is no fire pump with high-pressure stream ability arranged at the fire station and there is no regulation on high-pressure fire-fighting pumps in a type approval and verification technology criterion for a fire engine.

Prediction Method for Fire Load Prediction of Bedding and Bags Using a Standard Normal Distribution (정규분포를 활용한 이불과 가방에 대한 화재 하중 예측 방안 연구)

  • Kim, Hyun-Do;Nam, Dong-Koon;Cho, Sung-Woo
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.7-14
    • /
    • 2015
  • This study suggests basic data for fire-resistant compartments to prevent fires from spreading in a traditional markets. As representative combustible goods handled in traditional markets, bedding and bags were chosen. The fire loads could be calculated using the porosity of the materials based on a standard normal distribution. The bedding and bag porosity were 98.7%, and 94.39%, respectively. The the fire load of bedding is $29.9kg/m^2$, and that of bags is $65.61kg/m^2$.

Analysis of restrained heated steel beams during cooling phase

  • Li, Guo-Qiang;Guo, Shi-Xiong
    • Steel and Composite Structures
    • /
    • v.9 no.3
    • /
    • pp.191-208
    • /
    • 2009
  • Observations from experiments and real fire indicate that restrained steel beams have better fire-resistant capability than isolated beams. Due to the effects of restraints, a steel beam in fire condition can undergo very large deflections and the run away damage may be avoided. However disgusting damages may occur in the beam-to-column connections, which is considered to be mainly caused by the enormous axial tensile forces in steel beams resulted from temperature decreasing after fire dies out. Over the past ten years, the behaviour of restrained steel beams subjected to fire during heating has been experimentally and theoretically investigated in detail, and some simplified analytical approaches have been proposed. While the performance of restrained steel beams during cooling has not been so deeply studied. For the safety evaluation and repair of steel structures against fire, more detailed investigation on the behaviour of restrained steel beams subjected to fire during cooling is necessary. When the temperature decreases, the elastic modulus and yield strength of steel recover, and the contraction force in restrained steel beams will be produced. In this paper, an incremental method is proposed for analyzing the behaviour of restrained steel beams subjected to cooling. In each temperature decrement, the development of deformation and internal forces of a restrained beam is divided into four steps, in order to consider the effect of the recovery of the elastic modulus and strength of steel and the contraction force generated by temperature decrease in the beam respectively. At last, the proposed approach is validated by FE method.

Estimation of Strength and Pore Structure of Alkali-Activated Fire Protection Materials at High Temperature (고온에서의 알칼리 활성화 내화성 결합재의 강도 및 공극구조 평가)

  • Song, Hun;Kim, Young-Ho;Kim, Wan-Ki;So, Hyung-Suk
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.4
    • /
    • pp.59-66
    • /
    • 2012
  • This study is interested in identifying the effectiveness of alkali-activated fire protection material compounds including the alkali-activator such as potassium hydroxide, sodium silicate and fly ash as the fire resistant finishing materials. Also, this paper is concerned with change in compressive strength and pore structure of the alkali-activated fire protection material at high temperatures. The testing methods of fire protection materials in high temperature properties are make use of TG-DSC and mercury intrusion porosimetry measurements. This study results show that compressive strength is rapidly degraded depending on a rise of heating temperature. Porosity showed a tendency to increase irrespective of specimen types. This is due to both the outbreak of collapse of gel comprising the cement and a micro crack by heating. However, alkali-activated fire protection material composed of potassium hydroxide, sodium silicate and fly ash has the thermal stability of the slight decrease of compressive strength and porosity at high temperature. These thermal stability is caused by the ceramic binding capacity induced by alkali activation reaction by the reason of the thermal analysis result not showing the decomposition of calcium hydrate.

Experimental Study on Fire-Resistant Characteristics of Bi-Directionally Prestressed Concrete Panel under RABT Fire Scenario (RABT 화재시나리오를 적용한 이방향 프리스트레스트 콘크리트 패널부재의 내화특성에 관한 실험적 연구)

  • Yi, Na-Hyun;Lee, Sang-Won;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.695-703
    • /
    • 2012
  • Recently, major infrastructure such as bridges, tunnels, PCCVs (Prestressed Concrete Containment Vessel), and gas tanks are Prestressed Concrete (PSC) structure types, which improve their safety by using confining effect from prestressing. Generally, concrete is known to be an outstanding fire resistant construction material. Because of this reason, researches related to extreme fire loaded PSC member behaviors are not often conducted even though PSC behavior under extreme fire loading is significantly different than that of ordinary reinforced concrete (RC) behavior. Therefore, in this study, RABT fire loading tests were performed on bi-directionally prestressed concrete panels with $1000{\times}1400{\times}300mm$ dimensions. The prestressed specimens were applied with 430 kN prestressing (PS) force using unbonded PS thread bars. Also, residual strength structural tests of fire tested PSC and ordinary RC structures were performed for comparison. The study results showed that PSC behavior under fire loading is significantly different than that of RC behavior.

Evaluation of Thermal Aging on PVC Using Thermo Gravimetry Analysis and Accelerated Thermal Aging Test (TGA와 가속열화를 이용한 전선 피복용 PVC의 열적 열화평가)

  • 박형주;김기환;김홍
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.45-50
    • /
    • 2004
  • Thermal degradation of PVC which used for insulator of 600V vinyl insulated wire has been studied by thermo gravimetry analysis and accelerated thermal aging test. The activation energy using thermo gravimetry analysis was determined by the kinetic methods, such as Kissinger and Flynn-Wall-Ozawa. The activation energy was determined to from 89.29 kJ/mol to 111.39 kJ/mol in 600V PVC insulated wire and from 97.80 kJ/mol to 119.25 kJ/mol in 600v heat-resistant PVC insulated wire. And also, the activation energy through a long-term thermal aging test was calculated by using Arrhenius equation In the low temperature of 8$0^{\circ}C$, 9$0^{\circ}C$, 10$0^{\circ}C$. The results showed that 600V PVC insulated wire was 92.16 kJ/mol, and 600v heat-resistant PVC insulated wire was 97.52 kJ/mol. Consequently, the activation energy of 600V heat-resistant PVC insulated wire is larger than 600V PVC insulated wire. Therefore, it can be predicted that 600V heat-resistant PVC insulated wire has a long-term stability relatively.

A Experimental Study on the Fire Resistant Performance of the High Strength Concrete with Loading and Unloading test (재하 및 비재하 내화 실험을 통한 고강도콘크리트의 내화성능에 관한 실험적 연구)

  • Kim, Woo-Jae;Kim, Hyun-Bae;Kim, Kyu-Yong;Kim, Young-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.61-64
    • /
    • 2009
  • Recently, the higher buildings are, the stronger concrete are used. Ultra high strength concrete have the possibility of spalling when a fire breaks out. so the fire-resistance performance is necessary to use the ultra high strength concrete on the high-rise building. On this study, the heating test for the concrete with loading/unloading is performed for ultra high strength concrete using nylon fiber. The heating test followed by ISO-834 heating curve on the real-size specimen and the strength of concrete are 60, 80, 100, 200 MPa.

  • PDF

A Study on Data Research for Fire Regulations and Fire Retardant in Interior Architecture (실내건축관련 소방(消防)규정과 방염(防炎)에 관한 연구)

  • Cho, Sung-O;Kim, Yong-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.95-102
    • /
    • 2010
  • Recently, a grow in size and features of Interior construction work over the complex and The Fire-related regulations have been strengthened for the prevention of fire damage. This study is purpose to propose interior design, construction and supervision for the efficient and reasonable way throughout the fire-related laws are investigated in interior architecture. First, the interior of the building work will be based on actual use Fire-related Laws and Regulations have be investigated. Second, based on analysis of material and facilities by Application can be used in production by the data were applied to the present. Third, the international Fire and Flame Retardant Standards for investigating and reviewing the relevant laws, differences and characteristics of each country were analyzed. Fourth, the various fire-related issues of regulation and the application of relevant provisions in the field works, the law's standards, and improvements were identified by analysis. Fire-Related Laws and Building codes that Safety Administration of the Fire Services are divided into design, it comes to approval from the municipal authorities with concerns about the fire that will fit on the Fire Department's administrative procedures and operations is necessary to integrate operations. In conclusion, Fire-related business are divided into Minister of Land, Transport and Maritime Affairs and Ministry of Public Administration and Security. So, Both institutions is need to be the cooperative work. It is necessary to the field supervision. Because, Flame-resistant performance standards in the field works applied are too complex. Last, Establishment of fire-related regulations will enact by private organizations and the experts to participate.

A Basic Study on Required Performance and Development Direction of Fire Resistance Wall on High-rise Building (초고층 건축물용 내화벽체 요구성능 및 개발방향 설정을 위한 기초연구)

  • Kim, Dae-Hoi;Park, Soo-Young
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.1-7
    • /
    • 2011
  • Recently the interest in disaster prevention on super tall buildings is increasing. Especially in fire, against increasing of evacuation time due to high-rise, It is being tried to minimize the fire spread in building. Fire compartments using the fire-resistant wall and door, typical method to control the fire spread in buildings, delay the fire spread to other compartments and consequently evacuation time increases. But the existing provisions adjure only 2-hour fire resistance with maximum limit regardless of the super tall buildings, so this is a obstacle for research and development of the fire resistance wall in super tall buildings. In this study, we reviewed the fire resistance ratings of the wall, and presented the development directions for the fire resistance wall in super tall buildings considering fire resistance, construction and application of the wall.

INTUMESCENT INORGANIC AND ORGANIC COATINGS

  • Kodolov, V.I.;Mikhalkina, T.M.;Shuklin, S.G.;Bystrov, S.G.;Larionov, K.I.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.130-137
    • /
    • 1997
  • Intumescent inorganic and organic coatings which dintr one from the other by the type of gas formers and the mechanisms of foam formation have been obtained and investigated. Inorganic intumescent coatings are the compositions based on water glass and mineral additives with different dispersity. Mineral additives contain adsorbed and absorbed water and carbonates which are destructed with the carbon dioxide and water evolution during the flame action on coating. The decreasing of mineral additives particle sizes under the mechanical milling with the fraction precipitation promotes the foam coke formation with less defects. Here the main structure of comparing compositions does not change. In organic coatings based on epoxy-polymers the polyammonium phosphate additive is used. It is the cabonization catalyst and the foam agent. The polyammonium phosphate of various dispersity employed is uniformly distributed on the polymeric matrix. The decreasing of the particle sizes leads to the increasing of the fire resistant properties of the intumescent coa-ting. The fire resistant analysis of the coating during more than an hour: the coating back side the temperature on plastic or wooden materials does not exceed 423K, and on metal-573K.

  • PDF