• 제목/요약/키워드: fire performance test

검색결과 620건 처리시간 0.029초

합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현 (Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection)

  • 박노진;유동근;유홍근
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

Evaluation on the Lightning Breakdown Voltages of Palm Oil and Coconut Oil under Non-Uniform Field at Small Gap Distances

  • Thien, Yee Von;Azis, Norhafiz;Jasni, Jasronita;Kadir, Mohd Zainal Abidin Ab;Yunus, Robiah;Ishak, Mohd Taufiq;Yaakub, Zaini
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.184-191
    • /
    • 2016
  • In recent years, there are a number of studies that have been carried out to explore the alternative for Mineral Oil (MO) as dielectric insulating fluid in transformers due to the increasing tight regulation on safety and environment. Vegetable oils have been identified as suitable candidate since it is biodegradable, non-toxic and high flash/fire points which ensure more in-service safety. Among the types of vegetable oils considered for transformers application are Palm Oil (PO) and Coconut Oil (CO). This paper presents an experimental study on the lightning breakdown voltages of PO and CO under non-uniform electric field based on needle-sphere electrodes configuration at 3 small gap distances. The type of PO used in this study is Refined Bleached and Deodorized Palm Oil (RBDPO) Olein. The main focus of this study is to examine the lightning breakdown performance of RBDPO and CO under different test conditions and assess its suitability as dielectric insulating fluid in transformers. The effect of voltage polarities (positive and negative) and testing methods (rising-voltage, up-and-down and multiple-voltage) were investigated. The data obtained from all tests were analysed by Weibull distribution in order to determine the withstand voltages for each type of oils. It was found that the breakdown voltages of RBDPO and CO are comparable with MO under positive lightning impulse. Under negative lightning impulse, the breakdown voltage of MO is slightly higher than RBDPO and CO. There is no significant effect of testing methods and voltage polarities on lightning breakdown voltages of RBDPO and CO. Based on the statistical analysis, it is found that the breakdown voltages of RBDPO and CO at 1% probability are slightly lower than MO.

사회기반 건설구조물의 단기 동적변위 산정기법 (A Short-term Dynamic Displacement Estimation Method for Civil Infrastructures)

  • 최재묵;정준연;구건희;김기영;손훈
    • 한국전산구조공학회논문집
    • /
    • 제30권3호
    • /
    • pp.249-254
    • /
    • 2017
  • 본 논문에서는 가속도계와 속도계를 활용한 단기 동적변위 산정기법을 소개한다. 본 기법에서 변위는 측정된 가속도와 속도 데이터를 칼만필터 기반 실시간 융합 알고리즘에 적용하여 추정된다. 기존 변위센서(LVDT, LDV, Vision 등)는 고정된 지지점과 설치를 위해 별도의 가설물을 필요로 했기 때문에 지진 발생 시나 해상교량 적용에 한계가 있었다. 또한 Laser/Vision 기반 센서의 경우 시야확보가 어려운 경우 활용이 제한된다. 본 기법에서는 부착식 센서인 가속도계와 속도계를 활용하기 때문에, 고정된 지지점이 필요 없을뿐더러 부착만 되면 시야확보 여부로부터 자유롭다. 따라서, 지진, 해상교량뿐만 아니라 화재 시에도 적용 가능하다. 변위추정을 위해 누적되는 가속도의 이중적분 오차는 속도 계측치로 보정되며, 실험실 규모 테스트를 통해 해당 기법을 검증하였다.

급성 일산화탄소 중독 환자에서 급성 심혈관계, 신경학적 독성의 위험요인과 노출 경로의 역학적 특성 (The Risk Factors of Acute Cardiovascular and Neurological Toxicity in Acute CO Poisoning Patients and Epidemiologic Features of Exposure Routes)

  • 박진수;신승열;서영호;정현민
    • 대한임상독성학회지
    • /
    • 제18권1호
    • /
    • pp.34-41
    • /
    • 2020
  • Purpose: This study evaluated aggressive hyperbaric oxygen therapy (HBOT) by understanding various exposure routes of acute carbon monoxide (CO) poisoning, the risk factors causing acute cardiovascular, and neurological toxicity caused by poisoning. Methods: A retrospective study was conducted based on the medical records of 417 acute CO poisoning patients who visited the emergency care unit from March 2017 to August 2019. The exposure routes, HBOT performance, age, sex, medical history (hypertension, diabetes mellitus, ischemic heart disease, heart failure), intentionality, loss of consciousness (LOC), intake with alcohol or sedatives, and initial test results (carboxyhemoglobin (COHb), troponin-I, electrocardiography, echocardiography, brain MRI) were examined. Comparative analysis of the clinical information was conducted between the groups that showed acute cardiovascular toxicity and neurological toxicity, and groups that did not. Results: Among 417 patients diagnosed with acute CO poisoning, 201 cases (48.2%) were intentional, and charcoal briquette was the most common route (169 patients (40.5%)). Two hundred sixteen cases (51.8%) were accidental, and fire was the most common route (135 patients (32.4%)). The exposure route was more diverse with accidental poisoning. Three hundred ninety-nine patients were studied for acute cardiovascular toxicity, and 62 patients (15.5%) were confirmed to be positive. The result was statistically significant in intentionality, LOC, combined sedatives, initial COHb, HTN, and IHD. One hundred two patients were studied for acute neurological toxicity, which was observed in 26 patients (25.5%). The result was statistically significant in age and LOC. Conclusion: Active HBOT should be performed to minimize damage to the major organs by identifying the various exposure routes of CO poisoning, risk factors for acute cardiovascular toxicity (intentionality, LOC, combined sedatives, initial COHb, HTN, IHD), and the risk factors for acute neurological toxicity (age, LOC).

사출성능 개선을 위한 사출용 가스발생기 연구 (Research on the Ejection Gas Generator to Improve Ejecting Performance)

  • 오석진;장승교;차홍석
    • 한국항공우주학회지
    • /
    • 제41권5호
    • /
    • pp.383-390
    • /
    • 2013
  • 유도탄의 사출성능 중 탄에 충격으로 작용하는 최대가속도의 감소는 유도탄의 비정상작동 방지와 내부 부품들의 크기 및 비용 감소 측면에서 매우 중요하다. 본 연구에서는 사출용 가스발생기의 작동에 의해 탄에 가해지는 최대가속도가 사출초기에 발생됨을 착안하여 사출초기에 영향을 미치는 설계인자를 조사하였다. 가스발생기 설계인자로 점화기 및 노즐마개를 선정하고, 설계인자 변경을 통해 가스발생기에 의해 발생되는 최대가속도를 실험적으로 조사하였다. 최종적으로 최대가속도 감소효과를 정량적으로 비교하기 위해 가스발생기 지상연소시험을 실시하였다. 그 결과 설계인자의 최적값들이 적용된 개선모델의 경우 기준모델에 비해 최대가속도를 약 68% 줄일 수 있음을 확인하였다.

회전익 항공기용 연료탱크 내추락 성능 시험평가 (Assessment of Crashworthiness Performance for Fuel Tank of Rotorcraft)

  • 김현기;김성찬;이종원;황인희;허장욱;신동우;전필선;정태경;하병근
    • 한국항공우주학회지
    • /
    • 제38권8호
    • /
    • pp.806-812
    • /
    • 2010
  • 회전익항공기 연료탱크는 추락시 승무원의 생존성과 직결되는 구성품이다. 1950년대부터 미육군에서는 항공기 추락 후 화재에 의한 사상자를 줄일 수 있는 방안으로 내충돌성 연료탱크에 적합한 특성을 갖는 소재를 개발하기 위해 다양한 노력을 기울여왔다. 그 결과로 1961년에 MIL-T-27422A라는 항공기 연료탱크 설계규격이 처음 등장하였고, 1970년부터 2002년까지 수회의 개정을 거쳐 2007년 MIL-DTL-27422D라는 미군사 규격으로 발전되었다. 한국형 기동헬기의 연료탱크는 미군사규격(MIL-DTL-27422D)에 따라 개발 및 성능인증시험이 수행되었으며, 연료탱크의 내추락 성능은 미군사 규격에 구체화된 충돌/충격시험으로 검증되도록 규정되어 있다. 본 연구는 한국형기동헬기 연료탱크의 내추락 성능 검증을 위해 수행된 충돌/충격시험 결과를 제시하고 있다.

객체 탐지 모델을 활용한 전기 아크 위험성 예측 시스템 개발 (Development of Prediction of Electric Arc Risk using Object Dection Model)

  • 이규빈;김승연;안동혁
    • 스마트미디어저널
    • /
    • 제9권1호
    • /
    • pp.38-44
    • /
    • 2020
  • 전기에너지에 대한 높은 의존도 때문에 국내에서 발생하는 화재 중 전기화재가 상당한 비중을 차지한다. 국내에서 발생하는 전기화재 4건 중 3건이 전선의 단락이나 접촉 불량에 의한 전기 아크에 의해 발생했다. 전기 아크란 절연체 사이에서 발생하는 전기적 전류의 방전 현상으로 순간적으로 상당한 열을 내뿜는다. 아크에 의한 전기 화재를 줄이기 위해서 본 연구에서는 전기 아크 위험성 예측을 목표로 한다. 아크 감지기에서 아크 데이터를 수집하고 시간순대로의 아크 데이터를 기반으로 그래프로 변환하였다. 머신 러닝의 데이터 학습에 서로 다른 시계열 데이터의 수로 변환한 그래프들을 사용하였다. 생성된 학습 모델의 성능을 측정하기 위해서 테스트 데이터를 기반으로 평가를 진행하였다. 결과에서 예측 시 사용하는 시계열 아크 데이터의 수가 20개일 때 예측률이 86%로 우수함을 확인하였다.

명중률 향상을 위한 이중추력형 비행모터 개발에 대한 연구 (A Study on Development of the Dual-thrust Flight Motor for Enhancing the Hit Probability)

  • 김한준;김은미;김남식;이원복;양영준
    • 한국추진공학회지
    • /
    • 제18권4호
    • /
    • pp.74-80
    • /
    • 2014
  • 본 논문은 무유도 로켓탄의 명중률을 향상시키기 위해 개발한 이중추력형 비행모터에 관하여 기술하였다. 고연소속도 특성을 지닌 더블베이스 추진제의 형상 조절을 통해 이중추력형 비행모터를 설계하였으며, 실제 지상연소시험을 통해 이중추력 성능을 확인하였다. 연소시험 결과 서스테이닝 단계와 부스팅 단계의 추력비는 약 1:7.6으로 정상적인 이중추력 특성을 보였으며, 압력강하에 의한 추진제 소화현상은 나타나지 않았다.

Application of the optimal fuzzy-based system on bearing capacity of concrete pile

  • Kun Zhang;Yonghua Zhang;Behnaz Razzaghzadeh
    • Steel and Composite Structures
    • /
    • 제51권1호
    • /
    • pp.25-41
    • /
    • 2024
  • The measurement of pile bearing capacity is crucial for the design of pile foundations, where in-situ tests could be costly and time needed. The primary objective of this research was to investigate the potential use of fuzzy-based techniques to anticipate the maximum weight that concrete driven piles might bear. Despite the existence of several suggested designs, there is a scarcity of specialized studies on the exploration of adaptive neuro-fuzzy inference systems (ANFIS) for the estimation of pile bearing capacity. This paper presents the introduction and validation of a novel technique that integrates the fire hawk optimizer (FHO) and equilibrium optimizer (EO) with the ANFIS, referred to as ANFISFHO and ANFISEO, respectively. A comprehensive compilation of 472 static load test results for driven piles was located within the database. The recommended framework was built, validated, and tested using the training set (70%), validation set (15%), and testing set (15%) of the dataset, accordingly. Moreover, the sensitivity analysis is performed in order to determine the impact of each input on the output. The results show that ANFISFHO and ANFISEO both have amazing potential for precisely calculating pile bearing capacity. The R2 values obtained for ANFISFHO were 0.9817, 0.9753, and 0.9823 for the training, validating, and testing phases. The findings of the examination of uncertainty showed that the ANFISFHO system had less uncertainty than the ANFISEO model. The research found that the ANFISFHO model provides a more satisfactory estimation of the bearing capacity of concrete driven piles when considering various performance evaluations and comparing it with existing literature.

iPVC 매립 상수도관의 내진 성능 및 내침하 성능 평가를 위한 시험적 연구 (Experimental Study for Earthquake and Subsidence-resistant Performance Evaluation of iPVC Buried Water Pipe)

  • 전법규;장성진;김재봉;주부석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.16-23
    • /
    • 2020
  • 우리나라의 연평균 지진발생 횟수는 꾸준히 증가하는 추세이다. 최근경주와 포항에서 규모 5를 초과하는 지진이 발생하여 상수도관의 피해가 다수 보고된 바 있다. 따라서 국내에서도 상수도관의 지진에 대한 대비가 필요 할 것으로 판단된다. 상수도관은 상수도 공급시스템 에 있어 혈관과도 같은 중요한 시설로서 다양한 규격과 재질의 배관으로 구성된다. 그러므로 지진에 의한 상수도관의 손상은 식수공급, 화재진압 등의 문제를 일으키게 되며, 인명 및 재산피해를 유발하게 된다. 하지만 국내에서는 시험 검증 및 경험에 의해 매립상수도관의 내진 성능이 평가된 예를 찾아보기 어렵다. 지진에 의한 상수도관의 손상은 액상화와 단층과 같은 지반의 변위지배적인 거동으로 인하여 발생한다. 지진에 의한 상수도관의 주된 파손은 배관 이음부에 집중되며 특히 직경 200mm 이하 배관이 위험한 것으로 조사되었다. 따라서 본 연구에서는 호칭 150mm의 클램프로 고정된 이음을 가지는 iPVC 매립 상수도관에 대하여 시험적인 접근으로 내진 성능 및 내침하 성능을 평가 하였다.