• Title/Summary/Keyword: fire performance test

검색결과 618건 처리시간 0.047초

해양플랜트용 H-120 등급 방화 댐퍼의 성능 실험 (Performance Experiment of H-120 Class Fire Damper for Offshore)

  • 박창수
    • 한국산업융합학회 논문집
    • /
    • 제20권5호
    • /
    • pp.425-430
    • /
    • 2017
  • This study propose CAE analysis of fire damper and design of the damper control system. Through the design of the damper system for ANSYS-CFX heat transfer. As a result of the analysis, continuance equation of the damper control. Climate system. Finaily, We have obtained a fire damper solution by using orthogonal array. The fire damper of the set of fixture and alveolus are made by using a CAE software. Also, the optimum design offshore structures. The new H-120 class fire damper was designed. In the near future, fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. The test results showed that the insulation of the damper blade was an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500mm on the unexposed side as specified test standard.

COMPARISON OF THE FIRE SUPPRESSION PERFORMANCE OF HALON REPLACEMENT AGENTS

  • Kim, Andrew K.;Joseph Z. Su
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.542-549
    • /
    • 1997
  • HFC-227ea and HCFC Blend A were evaluated using full-scale fire tests to obtain information on their fire suppression performance, drop-in capability, thermal decomposition products and physical behaviour of the agent such as its flow characteristics in the piping system. Also, full-scale tests were conducted with Halon 1301 to provide a basis for comparison. Halon 1301, at concentrations of 5% to 7.5%, showed effective total-flooding fire- extinguishing performance for all test scenarios. HFC-227ea, at a design concentration of 7.6% or higher, and HCFC Blend A, at a design concentration of 12%, extinguished all fires in the test facility, however, these agents produced higher concentrations of acid gases than Halon 1301. The quantity of the acid gases generated during fire suppression was dependent on agent concentration, agent discharge time, fire type and size as well as extinguishment time.

  • PDF

룸코너 시험을 이용한 배관용 보온재의 난연성능 분석 (Evaluation of the Reaction-to-fire Performance of Pipe Insulation Material using Small Room Test)

  • 임옥근;남동군;장효연
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.1-8
    • /
    • 2019
  • 천장이나 배관에 설치된 보온재의 연소로 인해 화재가 확산되는 사례가 발생함에 따라 수계소화설비의 배관보온재는 난연재료 성능 이상의 것을 사용하고 있다. 배관보온재의 일부분을 시편으로 가공하여 난연성능을 평가하고 있지만 설치환경을 고려한 실규모시험을 통한 평가는 이루어지지 않고 있다. 본 연구에서는 국내에서 널리 사용되고 있는 발포폴리에틸렌폼 및 고무발포보온재를 실규모 시험기준인 ISO 20632에 따라 시험하고 유럽의 난연성능 분류 기준과 비교하였다. 배관보온재 재료별로 상이한 난연성능을 보였으며, 특히 발포폴리에틸렌폼보온재의 경우 시공방법에 따라 화재성장율 및 열방출율이 달라졌다. 화재발생 시 배관보온재로 인한 연소확산을 지연시키기 위해서는 설치하는 대상공간의 특성을 고려한 난연성능 적용이 필요하며, 시공 시 사용하는 접착제와 테이프 등 부자재의 난연성 또한 고려해야 함을 확인할 수 있었다.

공동주택 세대 현관 방화문 구조 및 성능에 관한 통계적 분석 (Statistical Analysis on the Structure and Performance of the Front Door in Apartment Housing)

  • 심한영;박원준
    • 한국건축시공학회지
    • /
    • 제22권1호
    • /
    • pp.115-123
    • /
    • 2022
  • 최근 10년간 주거시설에서 발생한 화재 중 공동주택이 약 40%를 차지하고 있다. 공동주택에서 화재 확산 방지와 피난을 위해 방화문의 내화성능과 성능설계가 중요해지고 있다. 본 연구는 화재성능시험을 통과한 2016년부터 2020년까지 품질검사보고서 395건의 DB를 구축하고 방화문의 구조(12개 요소)를 분석을 통하여 방화문 성능영향인자를 도출하였다. 결과로서, 287건의 합격사례에서 내화충진재와 밀도, 접착제, 발포제의 영향을 확인하였다. 한편, 불합격 사례 108건에서 화염발생과 틈새발생이 방화문 내화시험에서 가장 큰 불합격 요소임을 확인하였다. 방화문은 내화성능 불합격을 방지하기 위하여 복합자재들로 구성이 되어 있으며, 구성 요소들의 위치 등 형태를 정형화하여 일률적인 품질관리가 필요하다. 본 연구의 DB 분석 결과를 바탕으로 공동주택의 대피공간문 및 공용부 방화문에 대하여도 추가적인 비교분석이 필요하다.

$CO_2$ 소화설비 구성부품 성능시험보고 (The Report on Test Results of CO Fire Extinguishing System)

  • 김기옥;이찬주;안병호
    • 방재기술
    • /
    • 통권14호
    • /
    • pp.5-12
    • /
    • 1993
  • This report is explained about test results of carbon dioxide extinguiching system components and pack-age type system (Kits) for automatic fire extinguishing system. A carbon dioxide system may be used to protect one or more hazards or hazards by menas of directional valves. Package system shall be installed to protect hazards within the limitations. The testing program was progressed by three items, external oppearance test, performance test and Total Flooding Fire Extinguishing System test. The object of this report is present the problem which apperar from the analysis of test results.

  • PDF

구조단열패널의 저에너지주택 적용을 위한 내화 및 단열성능 평가 (Fire Resistance Performance and Thermal Performance Evaluation of Structural Insulated Panels for Low-Energy Houses)

  • 이현주;나환선;이철희;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제3권2호
    • /
    • pp.36-46
    • /
    • 2012
  • Structure Insulated Panel (SIP) is an wooden structure material with which structure and insulation functions are satisfied. Hence, it would be a cost-effective model to implement low energy house which has higher insulation and structure performance and which the wall thickness is able to be reduced. In this study, performance of thermal insulation and fire resistance were evaluated in order to verify applicability to low energy house. Fire resistance test is performed on vertical load bearing members for partitions, and the test results satisfy one hour of fire resistance condition according to KS F 2257. The members include two layers of fireproof gypsum board with thicknesses of 12.5mm attached to SIP. Thermal insulation performance is satisfied with the 2012 standard ($0.225W/m^2{\cdot}K$). As the performance of resistance and thermal insulation are satisfied, SIP is expected to be applied to low energy building materials. In the future, the structural safety will be confirmed by structural performance and seismic performance test and the guidelines for distribution will be drawn up.

실화재실험을 통한 상수도 직결형 스프링클러시스템의 성능에 관한 연구 (A Study on the Performance of a Sprinkler System with Direct-Coupled Waterworks by Full-Scale Fire Test)

  • 정종진;남동군;임우섭
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.39-43
    • /
    • 2011
  • 본 연구에서는 상수도 직결형 스프링클러 시스템의 성능을 평가하기 위하여 실물 주택을 대상으로 화재 실험을 수행하였다. 실물 주택의 크기는 $56m^2$이며 거실, 주방, 방으로 이루어져 있으며, 화재는 대두유가 과열되어 자연발화가 발생하여 일어나게 하였다. 상수도 직결형 스프링클러시스템의 성능을 확인하기 위하여 주방에 스프링클러시스템을 설치하였다. 실험결과 주방에서의 발화로 시작된 화재는 주방천장까지 확대 되었으나 스프링클러가 동작하면서 화재는 진압되었다. 스프링클러가 동작할 때의 상수도 압력은 0.28 MPa이었으며 이 결과로서 일반 주택의 상수도압력으로도 소화가 가능함을 확인할 수 있었다.

강구조 내화성능의 이론적 평가방법에 관한 조사연구

  • 성시창
    • 방재기술
    • /
    • 통권20호
    • /
    • pp.42-47
    • /
    • 1996
  • Prior to real fire test, theoretical of the fire resistant performance of the structural ele-ments is often less time consuming and less costly to calculate it, than to determine the perform-ance experimentally. This study is aimed at introduction of estimating methods of the fire resistant performance of the steel structural elements not by the actual fire tests but by the mathematical models.

  • PDF

압력스위치 성능시험보고 (A Report on Test Results of Pressure Operated Switch)

  • 권오승
    • 방재기술
    • /
    • 통권12호
    • /
    • pp.5-9
    • /
    • 1992
  • This reoprt is explained about test results of pressure operated switch for automatic fire extinguishing systems. It may include pressure operated Switch for automatic water supply control valves for use in automatic fire suppression system for fire protection service. The testing program was progressed devided by Two testing items, extermal oppearane test and performance test. The object of this report is present the problem which appear from the analysis of test results.

  • PDF

실험적 방법에 의한 ICT 파이어 댐퍼의 내화성능연구 (Fireproof Performance Study of ICT Fire Damper by Using Experimentalmethode)

  • 허남수;김인환;장성철;김재웅
    • 한국기계가공학회지
    • /
    • 제13권5호
    • /
    • pp.82-89
    • /
    • 2014
  • In this paper, fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. Specimens were fabricated three different types according to the change of the insulation system applied to damper blade and coaming which were measured surface temperature by performing the fire resistance test. As a test result, specimen-1, 2 of an uninsulated damper blade were exceeded thermal insulation acceptance criteria at 21 minutes, 46 minutes respectively, but specimen-3 of an insulated damper blade was satisfied thermal insulation acceptance criteria during 120 minutes. The test results showed that the insulation of the damper blade was an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500 mm on the unexposed side as specified test standard.