• Title/Summary/Keyword: fire outbreak

Search Result 75, Processing Time 0.026 seconds

Fire Sensing and Position Tracing using CCD Camera (CCD 카메라를 이용한 화재감지 및 화재 위치 추적)

  • Kim, Jang-Won;Baek, Dong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.166-168
    • /
    • 2009
  • In this paper, we studied fire sensing and position tracing system in fire region. The coordinates of fire position is communicated to fire suppression system immediately. And the fire is suppressed by this system effectively. For the purpose, the fire occurrence region images are extracted with two different CCD surveillance cameras and fire occurrence are sensed, I suggested a method to measure the fire occurrence position. It was able to be sensed early experiment result fire outbreak and, I was able to understand a fire outbreak position coordinate at the moment when a fire occurred and, I confirmed that I could accomplish warning official announcement and fire suppression in an auto.

  • PDF

Study on Efficient Operation on Aerial Fire Fighting Helicopter in Forest Fire (산불진화 헬기의 효율적인 운영방안 연구)

  • Bae, Taek-Hoon;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • This research analyzed synthetically the characteristic of forest helicopter, fire helicopter, civil helicopter and deployment assets are in operated in forest fire places of our country. Looking at arrangement of helicopter, Chung-buk, Jeonnam has a number of outbreak a forest fire rather than others but it is weak of initial fire attack by a gap of helicopter arrangement. Geong-gi has many helicopter while it is a relatively few outbreak of a helicopter. According to this, We read to consider that Gang-won need to rent more a helicopters and civil helicopter in each weak areas by government expense. In addition Dae-jeon, Chung-buk and Jeon-nam need arrangement of helicopter after secure rental budget. Especially, Dae-jeon need to consider opening base of fire helicopter.

A Case Study on the Lights Fire(Focus on the Electric Bulbs and Fluorescent Lamps) (조명등 화재사례 연구(전구 및 형광등 중심으로))

  • Song, T.H.;Lee, E.P.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.41-58
    • /
    • 2008
  • The history of illumination has been much long since the discovery of lamplight caused huge changes in human lives. However, the swift development of the illumination actually started with the invention of a carbon filament lamp by Thomas Edison in 1878. Generally, the illumination tools plays important roles in human lives such as reduction of fatigue, improvement of safety and working efficiency, and the creation of enjoyable atmosphere. But, the illumination tools can be an origin of the fire due to carelessness and lack of management. In this study, the principle and structure of the illumination lamp were dealt with. The possibility of the fire outbreak caused by the incandescent lamp and fluorescent lamp most used in home was investigated. The examples of the fire outbreaks by the incandescent and fluorescent lamps and by the contact between the inflammable materials and the distributing wires were mentioned and demonstrated by the experimental.

  • PDF

Effect of Rainfall During the Blossom Infection Risk Period on the Outbreak of Fire Blight Disease in Chungnam province (꽃감염 위험기간 중의 강우가 충남지역 과수 화상병 발병에 미치는 영향)

  • Byungryun Kim;Yun-Jeong Kim;Mi-Kyung Won;Jung-Il Ju;Jun Myoung Yu;Yong-Hwan Lee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.4
    • /
    • pp.302-310
    • /
    • 2023
  • In this study, the extent of the impact of rainfall on the outbreak of fire blight during the blossom infection risk period was explored. In the Chungnam province, the outbreak of fire blight disease began in 2015, and changes in the outbreak's scale were most pronounced between 2020 and 2022, significantly escalating from 63 orchards in 2020 to 170 orchards in 2021, before decreasing to 46 orchards in 2022. In 2022, the number of incidence has decreased and the number of canker symptom in branches has also decreased. It was evaluated that the significant decrease of fire blight disease in 2022 was due to the dry weather during the flowering season. In other words, this yearly fluctuation in fire blight outbreaks was correlated with the presence or absence of rainfall and accumulated precipitation during the blossom infection risk period. This trend was observed across all surveyed regions where apples and pears were cultivated. Among the weather conditions influencing the blossom infection risk period, rainfall notably affected the activation of pathogens from over-wintering cankers and flower infections. In particular, precipitation during the initial 3 days of the blossom infection risk warning was confirmed as a decisive factor in determining the outbreak's scale.

A Study on Ship Evacuation Safety Consequent on the Size and Sort of Fire (화재의 크기와 종류에 따른 선박 피난 안전 연구)

  • KIM, Won-Ouk;KIM, Dae-Hee
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.5
    • /
    • pp.1358-1364
    • /
    • 2016
  • Maritime accidents caused by a ship include collisions, sinking, stranding and fire etc. This study is intending to consider fire accidents among such diverse marine accidents. It is much likely that various sorts of fires break out because crewmen are living in a narrow space for long periods of time consequent on the ship's characteristic of sailing on the sea. According to the ship fire survey, about 50% of the total fire accidents occurred at an engine room, and the main fire origin was analyzed to be oil. In addition, ship fire breaks out in the order of baggage racks and living quarter. In short, the survey indicates that all sorts of fires belonging to A, B, C and D-class have occurred. This study, targeting an actual passenger ship 'A', found the response time to evacuation, during which the people on board a ship recognize the outbreak of fire, and act, and the travel time for evacuation which is the actual travel time. In addition, this study carried out a simulation through the special program for fire analysis - FDS (Fire Dynamics Simulator) in order to find the effective evacuation time, i.e. life survival time. Particularly, this study did comparative analysis of the influence on the survival of passengers and crew based on the collected simulation data by fire size and sort. As a result of the analysis, it was found that when examining the only actual evacuation movement time excepting the response time to evacuation, people are safe by completing evacuation before the effective evacuation time only in case fire size is 100Kw among all sorts of fires. In other words, in case of the outbreak of fire more than 1 MW, it was found to fail to meet evacuation safety regardless of fire size.

Analysis of University Cafeteria Safety Based on Pathfinder Simulation

  • Zechen Zhang;Jaewook Lee;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.209-217
    • /
    • 2024
  • Recent years have seen a notable increase in fire incidents in university cafeterias, yet the social attention to these occurrences remains limited. Despite quick responses to these incidents preventing loss of life, the need for large-scale evacuation in such high foot traffic areas can cause significant disruptions, economic losses, and panic among students. The potential for stampedes and unpredictable damage during inadequate evacuations underscores the importance of fire safety and evacuation research in these settings. Previous studies have explored evacuation models in various university environments, emphasizing the influence of environmental conditions, personal characteristics, and behavioral patterns on evacuation efficiency. However, research specifically focusing on university cafeterias is scarce. This paper addresses this gap by employing Pathfinder software to analyze fire spread and evacuation safety in a university cafeteria. Pathfinder, an advanced emergency evacuation assessment system, offers realistic 3D simulations, crucial for intuitive and scientific evacuation analysis. The studied cafeteria, encompassing three floors and various functional areas, often exceeds a capacity of 1500 people, primarily students, during peak times. The study includes constructing a model of the cafeteria in Pathfinder and analyzing evacuation scenarios under different fire outbreak conditions on each floor. The paper sets standard safe evacuation criteria (ASET > RSET) and formulates three distinct evacuation scenarios, considering different fire outbreak locations and initial evacuation times on each floor. The simulation results reveal the impact of the fire's location and the evacuation preparation time on the overall evacuation process, highlighting that fires on higher floors or longer evacuation preparation times tend to reduce overall evacuation time.In conclusion, the study emphasizes a multifaceted approach to improve evacuation safety and efficiency in educational settings. Recommendations include expanding staircase widths, optimizing evacuation routes, conducting regular drills, strengthening command during evacuations, and upgrading emergency facilities. The use of information and communication technology for managing emergencies is also suggested. These measures collectively form a comprehensive framework for ensuring safety in educational institutions during fire emergencies.

Development of Compensation-Type Fire Detector Using Metal-Insulator-Transition Critical-Temperature Sensor (금속-절연체 전이 임계온도센서를 이용한 보상식 화재 감지기 개발)

  • Jung, Sun-Kyu;Kim, Hyun-Tak
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.26-30
    • /
    • 2014
  • A Compensation-type fire detector (CFD) is operated with two functions of a differential-temperature detector and as a fixed-temperature detector. The differential-temperature detector observes a rate of temperature increase, and the fixed-temperature detector measures a given fixed temperature. The differential-temperature detector does not observe the outbreak of fire in slowly increasing temperature conditions, whereas the fixed-temperature detector is not able to observe the outbreak of fire in conditions under predetermined temperature level. We developed a CFD to compensate for weaknesses of both detectors. To compensate for the disadvantages, a sensor of the sensor metal-insulator-transition critical-temperature sensor was used. Temperature coefficient of resistance is the sensitivity for sensor. At $55^{\circ}C$, temperature coefficient of resistance of metal-insulator-transition critical-temperature sensor was 14.15%. Temperature coefficient of resistance of thermistor was about 0.5%. This CFD was operated as two ways that fixed-temperature detector and differential-temperature detector in one sensor.